Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Gyrokinetic Particle Simulation of Turbulent Transport in Burning Plasmas

In this project, we have developed techniques for visualizing large-scale time-varying multivariate particle and field data produced by the GPS_TTBP team. Our basic approach to particle data visualization is to provide the user with an intuitive interactive interface for exploring the data. We have designed a multivariate filtering interface for scientists to effortlessly isolate those particles of interest for revealing structures in densely packed particles as well as the temporal behaviors of selected particles. With such a visualization system, scientists on the GPS-TTBP project can validate known relationships and temporal trends, and possibly gain new insights in their simulations. We have tested the system using over several millions of particles on a single PC. We will also need to address the scalability of the system to handle billions of particles using a cluster of PCs. To visualize the field data, we choose to use direct volume rendering. Because the data provided by PPPL is on a curvilinear mesh, several processing steps have to be taken. The mesh is curvilinear in nature, following the shape of a deformed torus. Additionally, in order to properly interpolate between the given slices we cannot use simple linear interpolation in Cartesian space but instead have to interpolate along the magnetic field lines given to us by the scientists. With these limitations, building a system that can provide an accurate visualization of the dataset is quite a challenge to overcome. In the end we use a combination of deformation methods such as deformation textures in order to fit a normal torus into their deformed torus, allowing us to store the data in toroidal coordinates in order to take advantage of modern GPUs to perform the interpolation along the field lines for us. The resulting new rendering capability produces visualizations at a quality and detail level previously not available to the scientists at the PPPL. In summary, in this project we have successfully created new capabilities for the scientists to visualize their 3D data at higher accuracy and quality, enhancing their ability to evaluate the simulations and understand the modeled phenomena.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-Time Visualization of Network Behaviors for Situational Awareness

Plentiful, complex, and dynamic data make understanding the state of an enterprise network difficult. Although visualization can help analysts understand baseline behaviors in network traffic and identify off-normal events, visual analysis systems often do not scale well to operational data volumes (in the hundreds of millions to billions of transactions per day) nor to analysis of emergent trends in real-time data. We present a system that combines multiple, complementary visualization techniques coupled with in-stream analytics, behavioral modeling of network actors, and a high-throughput processing platform called MeDICi. This system provides situational understanding of real-time network activity to help analysts take proactive response steps. We have developed these techniques using requirements gathered from the government users for which the tools are being developed. By linking multiple visualization tools to a streaming analytic pipeline, and designing each tool to support a particular kind of analysis (from high-level awareness to detailed investigation), analysts can understand the behavior of a network across multiple levels of abstraction.

97 MATHEMATICS AND COMPUTING↗

Exploring Time-Varying Multivariate Volume Data Using Matrix of Isosurface Similarity Maps

We present a novel visual representation and interface named the matrix of isosurface similarity maps (MISM) for effective exploration of large time-varying multivariate volumetric data sets. MISM synthesizes three types of similarity maps (i.e., self, temporal, and variable similarity maps) to capture the essential relationships among isosurfaces of different variables and time steps. Additionally, it serves as the main visual mapping and navigation tool for examining the vast number of isosurfaces and exploring the underlying time-varying multivariate data set. We present temporal clustering, variable grouping, and interactive filtering to reduce the huge exploration space of MISM. In conjunction with the isovalue and isosurface views, MISM allows users to identify important isosurfaces or isosurface pairs and compare them over space, time, and value range. More importantly, we introduce path recommendation that suggests, animates, and compares traversal paths for effectively exploring MISM under varied criteria and at different levels-of-detail. A silhouette-based method is applied to render multiple surfaces of interest in a visually succinct manner. We demonstrate the effectiveness of our approach with case studies of several time-varying multivariate data sets and an ensemble data set, and evaluate our work with two domain experts.

97 MATHEMATICS AND COMPUTING↗

Automating Traffic Microsimulation from SYNCHRO UTDF to SUMO

Modern transportation research relies on seamlessly integrating traffic signal data with robust network representation and simulation tools. This study presents utdf2gmns, an open-source Python tool that automates conversion of the Universal Traffic Data Format, including network representation, signalized intersections, and turning volumes into the General Modeling Network Specification (GMNS) Standard. The resulting GMNS-compliant network can be converted for microsimulation in SUMO. By automatically extracting intersection control parameters and aligning them with GMNS conventions, utdf2gmns minimizes manual preprocessing and data loss. utdf2gmns also integrates with the Sigma-X engine to extract and visualize key traffic control metrics, such as phasing diagrams, turning volumes, volume-tocapacity ratios, and control delays. This streamlined workflow enables efficient scenario testing, accurate model building, and consistent data management. Validated through case studies, utdf2gmns reliably models complex urban corridors, promoting reproducibility and standardization. Documentation is available on GitHub and PyPI, supporting easy integration and community engagement.

Luo, Roy [ORNL] (ORCID:0009000312909983)↗

Reduced volume of diabetic pancreatic islets in rodents detected by synchrotron X-ray phase-contrast microtomography and deep learning network

The pancreatic islet is a highly structured micro-organ that produces insulin in response to rising blood glucose. Here we develop a label-free and automatic imaging approach to visualize the islets in situ in diabetic rodents by the synchrotron radiation X-ray phase-contrast microtomography (SRμCT) at the ID17 station of the European Synchrotron Radiation Facility. The large-size images (3.2 mm × 15.97 mm) were acquired in the pancreas in STZ-treated mice and diabetic GK rats. Each pancreas was dissected by 3000 reconstructed images. The image datasets were further analysed by a self-developed deep learning method, AA-Net. All islets in the pancreas were segmented and visualized by the three-dimension (3D) reconstruction. After quantifying the volumes of the islets, we found that the number of larger islets (=>1500 μm 3 ) was reduced by 2-fold (wt 1004 ± 94 vs GK 419 ± 122, P < 0.001) in chronically developed diabetic GK rat, while in STZ-treated diabetic mouse the large islets were decreased by half (189 ± 33 vs 90 ± 29, P < 0.001) compared to the untreated mice. Our study provides a label-free tool for detecting and quantifying pancreatic islets in situ. It implies the possibility of monitoring the state of pancreatic islets in vivo diabetes without labelling.

59 BASIC BIOLOGICAL SCIENCES↗

Large Data Visualization on Distributed Memory Mulit-GPU Clusters

Data sets of immense size are regularly generated on large scale computing resources. Even among more traditional methods for acquisition of volume data, such as MRI and CT scanners, data which is too large to be effectively visualization on standard workstations is now commonplace. One solution to this problem is to employ a 'visualization cluster,' a small to medium scale cluster dedicated to performing visualization and analysis of massive data sets generated on larger scale supercomputers. These clusters are designed to fit a different need than traditional supercomputers, and therefore their design mandates different hardware choices, such as increased memory, and more recently, graphics processing units (GPUs). While there has been much previous work on distributed memory visualization as well as GPU visualization, there is a relative dearth of algorithms which effectively use GPUs at a large scale in a distributed memory environment. In this work, we study a common visualization technique in a GPU-accelerated, distributed memory setting, and present performance characteristics when scaling to extremely large data sets.

97 MATHEMATICS AND COMPUTING↗

COMBIgor (A data assistant for combinatorial scientists in Igor Pro) [SWR-19-16]

Combinatorial materials science experiments involve synthesis and spatially-resolved characterization of thin film sample libraries. As a result, the modern combinatorial materials science laboratory produces large, diverse, and complex data sets, requiring automation of analysis and visualization techniques. COMBIgor is a software package aimed to assist a combinatorial material scientists with large volumes of experimental data. This package, written in Igor Pro, offers a systematic approach to the loading, processing, and visualizing combinatorial data sets. COMBIgor is designed to be expanded on a laboratory, group, or individual basis to adopt additional loading, processing and visualization capabilities. By utilizing COMBIgor software package the burden of data management in combinatorial materials science experiments can be significantly reduced.

Bauers, Sage↗

{sup 18}F-Fluorodeoxyglucose Positron Emission Tomography-Based Assessment of Local Failure Patterns in Non-Small-Cell Lung Cancer Treated With Definitive Radiotherapy

Purpose: To assess the pattern of local failure using {sup 18}F-fluorodeoxyglucose (FDG)-positron emission tomography (PET) scans after radiotherapy (RT) in non-small-cell lung cancer (NSCLC) patients treated with definitive RT whose gross tumor volumes (GTVs) were defined with the aid of pre-RT PET data. Method and Materials: The data from 26 patients treated with involved-field RT who had local failure and a post-RT PET scan were analyzed. The patterns of failure were visually scored and defined as follows: (1) within the GTV/planning target volume (PTV); (2) within the GTV, PTV, and outward; (3) within the PTV and outward; and (4) outside the PTV. Local failure was also evaluated as originating from nodal areas vs. the primary tumor. Results: We analyzed 34 lesions. All 26 patients had recurrence originating from their primary tumor. Of the 34 lesions, 8 (24%) were in nodal areas, 5 of which (63%) were marginal or geographic misses compared with only 1 (4%) of the 26 primary recurrences (p = 0.001). Of the eight primary tumors that had received a dose of <60 Gy, six (75%) had failure within the GTV and two (25%) at the GTV margin. At doses of {>=}60 Gy, 6 (33%) of 18 had failure within the GTV and 11 (61%) at the GTV margin, and 1 (6%) was a marginal miss (p < 0.05). Conclusion: At lower doses, the pattern of recurrences was mostly within the GTV, suggesting that the dose might have been a factor for tumor control. At greater doses, the treatment failures were mostly at the margin of the GTV. This suggests that visual incorporation of PET data for GTV delineation might be inadequate, and more sophisticated approaches of PET registration should be evaluated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hierarchical Clustering and Visualization of Aggregate Cyber Data

Most commercial intrusion detections systems (IDS) can produce a very high volume of alerts, and are typically plagued by a high false positive rate. The approach described here uses Splunk to aggregate IDS alerts. The aggregated IDS alerts are retrieved from Splunk programmatically and are then clustered using text analysis and visualized using a sunburst diagram to provide an additional understanding of the data. The equivalent of what the cluster analysis and visualization provides would require numerous detailed queries using Splunk and considerable manual effort.

Patton, Robert M↗

In Situ Visualization and Production of Extract Databases

Simulations running at high concurrency on HPC systems generate large volumes of data that are impractical to write to disk due to time and storage constraints. Applications often adapt by saving data infrequently, resulting in datasets with poor temporal resolution. This can make datasets difficult to interpret during post hoc visualization and analysis, or worse, it can lead to lost science. In Situ visualization and analysis can enable efficient production of small data products such as rendered images or surface extracts that consist of polygonal geometry plus fields. These data products are far smaller than their source data and can be processed much more economically in a traditional post hoc workflow using far fewer computational resources. We used the SENSEI and Libsim in situ infrastructures to implement rendering workflow and surface data extraction workflows in the AVF-LESLIE combustion code. Finally, these workflows were then demonstrated at high levels of concurrency and showed significant data reductions and limited impact on the simulation runtime.

97 MATHEMATICS AND COMPUTING↗

Report for the ASCR Workshop on Visualization for Scientific Discovery, Decision-Making, and Communication

Visualization—the use of visual elements to explore data, form hypotheses, or convey conclusions—is an integral part of the scientific process. Starting from an initial exploration of new data to illustrating outcomes for the general public, visualization is one of the most intuitive and powerful modes of communication. With the explosion of new data sources and types, unprecedented volumes of data, and new technologies, such as virtual reality (VR) and artificial intelligence (AI), visualization has become increasingly essential but also ever more challenging. The Department of Energy’s (DOE) Office of Advanced Scientific Computing Research (ASCR) sponsored a Basic Research Needs workshop in January 2022 to understand the major opportunities and grand challenges in visualization tools and technologies for scientific computing as well as for DOE-relevant applications and goals in general. The workshop identified five priority research directions (PRDs) for visualization to support scientific discovery, decision making, and communication. The first three PRDs describe interconnected research themes addressing the need for new techniques to deal with complex data, uncertainty, and interpretability (PRD 1); the need for scalable and interoperable software stacks (PRD 2); and the challenges and opportunities inherent in new technologies, such as VR, cloud, or exascale computing (PRD 3). The remaining two PRDs describe foundational research themes that recognize the potential of visualizations to provide equitable access to information and to strengthen the scientific discourse (PRD 4); and the need to consider human factors when designing visualizations (PRD 5). Collectively, these PRDs form the pillars for a coherent, long-term research and development strategy in Visualization for Scientific Discovery, Decision-Making, and Communication in the context of the Office of Science’s mission scope.

97 MATHEMATICS AND COMPUTING↗

TH-A-BRF-05: MRI of Individual Lymph Nodes to Guide Regional Breast Radiotherapy

Purpose: In regional radiotherapy (RT) for breast-cancer patients, direct visualization of individual lymph nodes (LNs) may reduce target volumes and Result in lower toxicity (i.e. reduced radiation pneumonitis, arm edema, arm morbidity), relative to standard CT-based delineations. To this end, newly designed magnetic resonance imaging (MRI) sequences were optimized and assessed qualitatively and quantitatively. Methods: In ten healthy female volunteers, a scanning protocol was developed and optimized. Coronal images were acquired in supine RT position positioned on a wedge board on a 1.5 T Ingenia (Philips) wide-bore MRI. In four volunteers the optimized MRI protocol was applied, including a 3-dimensional (3D) T1-weighted (T1w) fast-field-echo (FFE). T2w sequences, including 3D FFE, 3D and 2D fast spin echo (FSE), and diffusion-weighted single-shot echo-planar imaging (DWI) were also performed. Several fatsuppression techniques were used. Qualitative evaluation parameters included LN contrast, motion susceptibility, visibility of anatomical structures, and fat suppression. The number of visible axillary and supraclavicular LNs was also determined. Results: T1 FFE, insensitive to motion, lacked contrast of LNs, which often blended in with soft tissue and blood. T2 FFE showed high contrast, but some LNs were obscured due to motion. Both 2D and 3D FSE were motion-insensitive having high contrast, although some blood remained visible. 2D FSE showed more anatomical details, while in 3D FSE, some blurring occurred. DWI showed high LN contrast, but suffered from geometric distortions and low resolution. Fat suppression by mDixon was the most reliable in regions with magnetic-field inhomogeneities. The FSE sequences showed the highest sensitivity for LN detection. Conclusion: MRI of regional LNs was achieved in volunteers. The FSE techniques were robust and the most sensitive. Our optimized MRI sequences can facilitate direct delineation of individual LNs. This can Result in smaller target volumes and reduced toxicity in regional RT compared to standard CT planning.

60 APPLIED LIFE SCIENCES↗

TU-D-202-03: Gating Is the Best ITV Killer

Respiratory motion has long been recognized as an important factor affecting the precision of radiotherapy. After the introduction of the 4D CT to visualize the respiratory motion in 3D, the internal target volume (ITV) has been widely adopted as simple method to take the motion into account in treatment planning and delivery. The ITV is generated as the union of the CTVs as the patient goes through the respiratory cycle. Many issues have been identified with the ITV. In this session three alternatives for the ITV will be discussed: 1) An alternative motion-inclusive approach with better imaging and smaller margins, called mid-position CT. 2) The tracking approach and 3) The gating approach. The following topics will be addressed by Marcel van Herk (“Is ITV the correct motion encompassing strategy”): Magnitude of respiratory motion, effect of motion on radiotherapy, motion encompassing strategies, and software solutions to assist in motion encompassing strategies. Then Paul Keall (“Make margins simple: Use real-time target tracking”) will discuss tracking with: clinical drivers for tracking, current clinical status of tumor tracking, future tumor tracking technology, and margin margin challenges with and without tracking. Finally Daniel Low will discuss gating (“Gating is the best ITV killer”): why ITV in the first place, requirements for planning, requirements at the machine, benefits and costs. The session will end with a discussion and live demo of motion simulation software to illustrate the issues and explain the relative benefit and appropriate uses for the three methods. Learning Objectives: Explain the 4D imaging and treatment planning process. Summarize the various approaches to deal with respiratory motion during radiotherapy Discuss the tradeoffs involved when choosing one of the three discussed approaches. Explain in which situation each method is the best choice Research is partly funded by Elekta Oncology Systems and the Dutch Cancer Foundation; M. van Herk, Part of the research was funded by Elekta Oncology Systems and the Dutch Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

Scientific Data Management Center for Enabling Technologies

Managing scientific data has been identified by the scientific community as one of the most important emerging needs because of the sheer volume and increasing complexity of data being collected. Effectively generating, managing, and analyzing this information requires a comprehensive, end-to-end approach to data management that encompasses all of the stages from the initial data acquisition to the final analysis of the data. Fortunately, the data management problems encountered by most scientific domains are common enough to be addressed through shared technology solutions. Based on community input, we have identified three significant requirements. First, more efficient access to storage systems is needed. In particular, parallel file system and I/O system improvements are needed to write and read large volumes of data without slowing a simulation, analysis, or visualization engine.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Testing of a 3-D Sonar for Future Deployment to Image Solids on the Floor of Hanford, HLW Conditioning Tanks - 15646

Florida International University (FIU) has tested the capability of 2-D and 3-D sonar systems to image solids settled on the floor of tanks, on the bottom of streams and small rivers, and in 55 gallon drums. FIU developed and successfully tested the Solid-Liquid Interface Monitor (SLIM) for mapping the interface between supernatant and settled solids in several test tanks. SLIM is comprised of: a sonar, a mechanical system for deploying the system into large high-level radioactive waste (HLW) tanks, and imaging programs and algorithms developed at and by FIU faculty and staff. Early testing had the objective to demonstrate the ability of SLIM to image and quantify the height and volume of settled solids on the floor of 1-million-gallon, HLW tanks at Hanford. Testing showed that SLIM: (1) functions accurately in liquid radioactive HLW tank conditions [i.e., caustic (pH>14), warm (up to 45 degrees Centigrade), and highly radioactive]; (2) provides accurate imaging of solids surfaces (1-2% relative error in the height of interfaces); and (3) provides an excellent volume estimation of the solids, thereby allowing engineers to fill tanks closer to the maximum allowed level and optimize solids retrieval; and (4) enables better placement of pumps inside tanks during retrieval to minimize the potential for plugging. The New Hanford technology need is for rapid imaging (even during vigorous mixing) of solids on the floor of conditioning (mixing) tanks. Results of recent successful testing show imaging times under 1 minute, solids volume estimates with <5% error and effective filtering and visualization. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improvement in Interobserver Accuracy in Delineation of the Lumpectomy Cavity Using Fiducial Markers

Purpose: To determine, whether the presence of gold fiducial markers would improve the inter- and intraphysician accuracy in the delineation of the surgical cavity compared with a matched group of patients who did not receive gold fiducial markers in the setting of accelerated partial-breast irradiation (APBI). Methods and Materials: Planning CT images of 22 lumpectomy cavities were reviewed in a cohort of 22 patients; 11 patients received four to six gold fiducial markers placed at the time of surgery. Three physicians categorized the seroma cavity according to cavity visualization score criteria and delineated each of the 22 seroma cavities and the clinical target volume. Distance between centers of mass, percentage overlap, and average surface distance for all patients were assessed. Results: The mean seroma volume was 36.9 cm{sup 3} and 34.2 cm{sup 3} for fiducial patients and non-fiducial patients, respectively (p = ns). Fiducial markers improved the mean cavity visualization score, to 3.6 {+-} 1.0 from 2.5 {+-} 1.3 (p < 0.05). The mean distance between centers of mass, average surface distance, and percentage overlap for the seroma and clinical target volume were significantly improved in the fiducial marker patients as compared with the non-fiducial marker patients (p < 0.001). Conclusions: The placement of gold fiducial markers placed at the time of lumpectomy improves interphysician identification and delineation of the seroma cavity and clinical target volume. This has implications in radiotherapy treatment planning for accelerated partial-breast irradiation and for boost after whole-breast irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and Implementation of 3-D, High Speed Capacitance Tomography for Imaging Large-Scale, Cold-Flow Circulating Fluidized Bed

A detailed understanding of multiphase flow behavior inside a Circulating Fluidized Bed (CFB) requires a 3-D technique capable of visualizing the flow field in real-time. Electrical Capacitance Volume Tomography (ECVT) is a newly developed technique that can provide such measurements. The attractiveness of the technique is in its low profile sensors, fast imaging speed and scalability to different section sizes, low operating cost, and safety. Moreover, the flexibility of ECVT sensors enable them to be designed around virtually any geometry, rendering them suitable to be used for measurement of solid flows in exit regions of the CFB. Tech4Imaging LLC has worked under contract with the U.S. Department of Energy's National Energy Technology Laboratory (DOE NETL) to develop an ECVT system for cold flow visualization and install it on a 12 inch ID circulating fluidized bed. The objective of this project was to help advance multi-phase flow science through implementation of an ECVT system on a cold flow model at DOE NETL. This project has responded to multi-phase community and industry needs of developing a tool that can be used to develop flow models, validate computational fluid dynamics simulations, provide detailed real-time feedback of process variables, and provide a comprehensive understating of multi-phase flow behavior. In this project, a complete ECVT system was successfully developed after considering different potential electronics and sensor designs. The system was tested at various flow conditions and with different materials, yielding real-time images of flow interaction in a gas-solid flow system. The system was installed on a 12 inch ID CFB of the US Department of Energy, Morgantown Labs. Technical and economic assessment of Scale-up and Commercialization of ECVT was also conducted. Experiments conducted with larger sensors in conditions similar to industrial settings are very promising. ECVT has also the potential to be developed for imaging multi-phase flow systems in high temperature and high pressure conditions, typical in many industrial applications.

42 ENGINEERING↗

Validating the RTOG-Endorsed Brachial Plexus Contouring Atlas: An Evaluation of Reproducibility Among Patients Treated by Intensity-Modulated Radiotherapy for Head-and-Neck Cancer

Purpose: To evaluate interobserver variability for contouring the brachial plexus as an organ-at-risk (OAR) and to analyze its potential dosimetric consequences in patients treated with intensity-modulated radiotherapy (IMRT) for head-and-neck cancer. Methods and Materials: Using the Radiation Therapy Oncology Group (RTOG)-endorsed brachial plexus contouring atlas, three radiation oncologists independently delineated the OAR on treatment planning computed-tomography (CT) axial scans from 5 representative patients undergoing IMRT to a prescribed dose of 70 Gy for head-and-neck cancer. Dose-volume histograms for the brachial plexus were calculated, and interobserver differences were quantified by comparing various dosimetric statistics. Qualitative analysis was performed by visually assessing the overlapping contours on a single beam's eye view. Results: Brachial plexus volumes for the 5 patients across observers were 26 cc (18-35 cc), 25 cc (21-30 cc), 29 cc (28-32 cc), 29 cc (23-38 cc), and 29 cc (23-34 cc). On qualitative analysis, minimal variability existed except at the inferolateral portion of the OAR, where slight discrepancies were noted among the physicians. Maximum doses to the brachial plexus ranged from 71.6 to 72.6 Gy, 75.2 to 75.8 Gy, 69.1 to 71.0 Gy, 76.4 to 76.9 Gy, and 70.6 to 71.4 Gy. Respective volumes receiving doses greater than 60 Gy (V60) were 8.6 to 10.9 cc, 6.2 to 8.1 cc, 8.2 to 11.6 cc, 8.3 to 10.5 cc, and 5.6 to 9.8 cc. Conclusion: The RTOG-endorsed brachial plexus atlas provides a consistent set of guidelines for contouring this OAR with essentially no learning curve. Adoption of these contouring guidelines in the clinical setting is encouraged.

62 RADIOLOGY AND NUCLEAR MEDICINE↗