Circuit Modelling of the Mechanical-Motion-Rectifier for Electrical Simulation of Ocean Wave Power Take-off

As is the case with several other mechanical power takeoffs (PTOs), the mechanical-motion-rectifier (MMR) based PTO consists of components such as one-way clutches, gears, a ball screw, mechanical couplings, and a generator. Equivalent circuit models have been created in this paper to describe the dry frictions, viscous damping, and mechanical compliances in these components, so the non-ideal efficiency and nonlinear force of the PTO can be predicted in electrical simulations by integrating these sub-circuit models. The circuit model is simplified, and its parameters are categorized as dc and ac unknowns. The dc and ac tests on the PTO are performed sequentially to extract two sets of parameters through linear regression or nonlinear curve fitting. Then, the model is validated through its prediction capability over 25 test conditions on input forces, output voltages, and efficiencies, with correlation coefficients of 0.9, 0.98, and 0.981, respectively.

42 ENGINEERING↗

Influence of Supporting Electrolyte on Hydroxide Exchange Membrane Water Electrolysis Performance: Anolyte

Hydroxide-exchange-membrane water electrolysis (HEMWE) is an emerging hydrogen-production pathway that combines many advantages of incumbent alkaline water electrolysis (AWE) and proton-exchange-membrane water electrolysis (PEMWE). Advancement in HEMWE has been accelerated with the development of stable and conductive hydroxide exchange membranes (HEMs) and a more comprehensive understanding of alkaline gas-evolving kinetics. However, performance and durability without supporting electrolytes (SELs) remain inferior to PEMWE and AWE and little is known about the role and impact of the SELs. This study investigates the effects of SELs used as anolyte solutions in HEMWEs including cation-type, anion-type, SEL conductivity and pH, presence of carbonates and increased cation/OH- ratios on cell voltage and stability. We report our findings that (i) cell potential and high-frequency resistance did not correlate with anolyte SEL conductivity, (ii) cation-type influences cell voltage at low current densities (<50 mA cm -2 ) as predicted by half-cell measurements, (iii) increased cation/OH- ratio causes increased overpotentials, and (iv) carbonates are exchanged in the HEM but removed via self-purging at high current density. Overall, this study concludes that concentrated KOH is still the best SEL.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quasi-1D Coulomb Drag in the Nonlinear Regime

One-dimensional Coulomb drag has been an essential tool to probe the physics of interacting Tomonaga-Luttinger liquids. To date, most experimental work has focused on the linear regime while the predictions for Luttinger liquids beyond the linear response theory remain largely untested. In this Letter, we report measurements of reciprocal momentum transfer induced Coulomb drag between vertically coupled quasi-one-dimensional quantum wires in the nonlinear regime. Measurements were performed at ultralow temperatures between wires only 15 nm apart. Our results reveal a nonlinear dependence of the drag voltage as a function of the drive current superimposed with an oscillatory contribution, in agreement with theoretical predictions for Coulomb drag between Tomonaga-Luttinger liquids. Additionally, the observed current-voltage characteristics exhibit a nonmonotonic temperature dependence, further corroborating the presence of non-Fermi-liquid behavior in our system. In conclusion, these findings are observed both in the single and in the multiple subband regimes and in the presence of disorder, extending the onset of this behavior beyond the clean single channel Tomonaga-Luttinger regime where the predictions were originally formulated.

1-dimensional systems↗

Nanosecond Transient Validation of Surge Arrester Models to Predict Electromagnetic Pulse Response

The impact of high-altitude electromagnetic pulse events on the electric grid is not fully understood, and validated modeling of mitigations, such as lightning surge arresters (LSAs) is necessary to predict the propagation of very fast transients on the grid. Experimental validation of high frequency models for surge arresters is an active area of research. Further, this article serves to experimentally validate a previously defined ZnO LSA model using four metal-oxide varistor pucks and nanosecond scale pulses to measure voltage and current responses. The SPICE circuit models of the pucks showed good predictability when compared to the measured arrester response when accounting for a testbed inductance of approximately 100 nH. Additionally, the comparatively high capacitance of low-profile arresters show a favorable response to high-speed transients that indicates the potential for effective electromagnetic pulse mitigation with future materials design.

42 ENGINEERING↗

Safe Deep Reinforcement Learning for Active Distribution System Model Predictive Control with EVs and DERs

The temporal and spatial mismatch between PV generation and electric vehicle (EV) charging and discharging may cause voltage violations in active distribution networks. Despite the widespread use of deep reinforcement learning (DRL) in power system optimization and control, it lacks guarantees on constraint satisfaction during both training and deployment. This paper proposes a Lagrangian-based safe DRL approach for model predictive control (MPC) of active distribution systems with large-scale integration of PVs, EVs, and energy storage systems (ESSs). A Transformer-LSTM time-series model is proposed to forecast EV charging demand, which is then formulated as a constraint to ensure charging requirements are met. Using this prediction, a Lagrangian-based safe soft actor-critic (SAC) framework is developed for real-time control in a three-phase unbalanced distribution system, enforcing voltage safety constraints while optimizing the cumulative net reward. By integrating the forecasting model with multi-period constraints, the proposed framework jointly coordinates PV systems, EV charging and discharging, and ESS scheduling within the MPC horizon. Numerical experiments on a modified IEEE 123-bus system with real-world data show that, under a high PV penetration scenario, the proposed method increases the net reward by 30.74% and reduces average voltage violations from 0.0011 p.u. to 0.0002 p.u. compared with standard SAC. Compared with the optimal power flow (OPF) approach, it achieves similar voltage security while yielding lower line losses. It also maintains real-time control capability, reducing operation latency to 53.21 ms per 15-minute control interval. The proposed method remains effective under varying PV/EV penetrations and load conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Engineered Multifunctional Composite for Passive Sensing, Power Harvesting, and In Situ Damage Identification with Enhanced Mechanical Performance

A multifunctional fiber-reinforced composite with passive self-sensing, energy-harvesting, and damage detection capabilities is presented. In this work, barium titanate piezoelectric microparticles are deposited on basalt fibers by a scalable, low-cost, environmentally friendly continuous feed-through process. The resulting composite derives a superior interlaminar shear strength from the microparticle-modified fiber–matrix interfaces. The composite also demonstrates passive self-sensing capabilities that produce electrical signals proportional to various dynamic loading events. Vibration and strain-controlled experiments are performed on composite beams to quantify the sensitivity and power output as a function of input acceleration and strain. Furthermore, these composite-generated electrical signals are used to identify in situ damage initiation for structural health monitoring to inform composite damage prior to structural failure. In brief, this truly multifunctional composite simultaneously displays a sensitivity of 0.5–2.6 mV g -1 at a resolution of 0.045–0.20g (g = gravitational acceleration), energy harvesting in the range of nW cc -1 , and prediction of early damage by exhibiting 0.017–1.17 mV peaks in voltage–time history profiles while assuring ≈20% improved interlaminar shear strength.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensitivity analysis of a layered piezoelectric system using ZFEM

The complex variable finite element method (ZFEM) is a numerical technique which aims to find the partial derivatives of the independent variables with respect to variation in dependent parameters declared in the physics. This is done by combining the complex Taylor series expansion within the weak formulation of the governing equation in a coupled system of linear equations forming a complex valued block matrix given by the Cauchy–Riemann matrix representation. In this work, two-dimensional linear first-order elements have been implemented in ZFEM to predict the design derivatives of the mechanical displacement field and the voltage potential field for a layered piezoelectric system in a steady-state study with Dirichlet boundary condition applied at the top and bottom edges of the geometry. This approach allows the standard FEM solution to quantify the sensitivity of the mechanical displacement and voltage potential fields with respect to small variations in the material properties through the information obtained from the computation of the derivatives. The domain is formed by a layered body with PZT-4 and PZT-5 stacked together. For result verification, the numerical solution obtained with ZFEM was compared to results from a commercial FEM package and the solution from the imaginary part was compared to the exact solution of a well-known benchmark problem. In conclusion, comparison of the results showed good agreement for both the real and imaginary parts of the solution and the largest sensitivities were found in PZT-5 specifically in C 13 , C 33 , and ε 33 .

42 ENGINEERING↗

A systematic strategy for estimating hERG block potency and its implications in a new cardiac safety paradigm

Introduction: hERG block potency is widely used to calculate a drug's safety margin against its torsadogenic potential. Previous studies are confounded by use of different patch clamp electrophysiology protocols and a lack of statistical quantification of experimental variability. Since the new cardiac safety paradigm being discussed by the International Council for Harmonisation promotes a tighter integration of nonclinical and clinical data for torsadogenic risk assessment, a more systematic approach to estimate the hERG block potency and safety margin is needed. Methods: A cross-industry study was performed to collect hERG data on 28 drugs with known torsadogenic risk using a standardized experimental protocol. A Bayesian hierarchical modeling (BHM) approach was used to assess the hERG block potency of these drugs by quantifying both the inter-site and intra-site variability. A modeling and simulation study was also done to evaluate protocol-dependent changes in hERG potency estimates. Results: A systematic approach to estimate hERG block potency is established. The impact of choosing a safety margin threshold on torsadogenic risk evaluation is explored based on the posterior distributions of hERG potency estimated by this method. The modeling and simulation results suggest any potency estimate is specific to the protocol used. Discussion: This methodology can estimate hERG block potency specific to a given voltage protocol. The relationship between safety margin thresholds and torsadogenic risk predictivity suggests the threshold should be tailored to each specific context of use, and safety margin evaluation may need to be integrated with other information to form a more comprehensive risk assessment.

60 APPLIED LIFE SCIENCES↗

Nonlinear ion transport mediated by induced charge in ultrathin nanoporous membranes

Ultrathin membranes with nanoporous conduits show promise for ionic separations and desalination applications, but the mechanisms underlying the nonlinear ionic transport observed in these systems are not well understood. Here, in this work, we demonstrate how induced charge at membrane interfaces can lead to nonlinear ionic transport and voltage-dependent conductance through such channels. The application of an electric field on a polarizable membrane leads to induced charges at the membrane interfaces. The induced charges in turn are screened by diffuse charges in the electrolyte, which are acted upon by the electric field. For extremely thin membranes, the induced charge effect can be significant even for moderate applied voltages commonly used in experiments. We apply a continuum Poisson-Nernst-Planck model to characterize the current-voltage behavior of ultrathin membranes over a wide parameter space. The predictions of the model are compared to recent experiments on graphene and MoS 2 membranes in an electric field. We expect the role of induced charge to be especially pronounced in the limit of atomically thin membranes.

36 MATERIALS SCIENCE↗

Health Assessment and Performance Monitoring of Large Machine Diagnostics

Presentation to be given at the CCS-6 Statistical Seminar Series. Regularly maintained and operated diagnostic machines are a backbone of data collection and are a vital component of the Stockpile Stewardship Program’s efforts to better understand nuclear physics. The Cygnus X-ray machine, stationed at the Nevada National Security Site’s U1a underground facility, is one such diagnostic that provides a radiographic capability for the subcritical experiment program. Component failures within Cygnus can result in catastrophic downtime for the diagnostic, affecting performance, schedules, and cost. However, over the years various measurements have been collected on the two Cygnus axes, including voltage and current measurements at different locations, which we believe have predictive power to indicate machine health. We will share preliminary insight into this data and the machine learning approaches we are taking to assess Cygnus’ health, observe declining performance, and predict failures.

97 MATHEMATICS AND COMPUTING↗

Control and Calibration of GlueX Central Drift Chamber Using Gaussian Process Regression

The Gluonic Excitations (GlueX) experiment is designed to search for exotic hybrid mesons using photoproduction, and to study the hybrid meson spectrum predicted from Lattice Quantum Chromodynamics. For the first time, the GlueX Central Drift Chamber was controlled autonomously using machine learning (ML) to calibrate in real time while recording cosmic ray tracks. We demonstrate the ability of a Gaussian Process to predict the gain correction calibration factor used to determine a high voltage setting that will stabilize the CDC gain in response to changing environmental conditions; this is in contrast to the traditional, computationally expensive method of calibrating raw data after data collection is complete.

McSpadden, Helen↗

Towards Generalizable and Efficient Circuit Topology Design: A Graph-Transformer-based Surrogate Model with Curriculum Learning

Unlike circuit parameter and sizing optimizations, the automated design of analog circuit topologies poses significant challenges for learning-based approaches. One challenge arises from the combinatorial growth of the topology space with circuit size, which limits the topology optimization efficiency. Moreover, traditional circuit evaluation methods are time-consuming, while the presence of data discontinuity in the topology space makes the accurate prediction of circuit performance exceptionally difficult for unseen topologies. To tackle these challenges, we design a novel Graph-Transformer-based Network (GTN) as the surrogate model for circuit evaluation, offering a substantial acceleration in the speed of circuit topology optimization without sacrificing performance. Our GTN model architecture is designed to embed voltage changes in circuit loops and current flows in connected devices, enabling accurate performance predictions for circuits with unseen topologies. To address the cold start problem when scaling GTN to large-scale circuits, we further introduce a curriculum learning strategy that progressively trains GTN from small-scale to large-scale circuits. This approach enables the model to first learn fundamental physical principles from simpler topologies and gradually adapt to complex configurations, effectively bridging the circuit complexity gap and improving prediction accuracy. Taking the power converter circuit design as an experimental task, our GTN model significantly outperforms an analytical approach and baseline methods directly utilizing graph neural networks. Furthermore, GTN achieves less than 5% relative error and 196× speed-up compared with high-fidelity simulation. Notably, our GTN surrogate model empowers an automatic circuit design framework to discover circuits of comparable quality to those identified through high-fidelity simulation while reducing the time required by up to 98.2%. With curriculum learning, the enhanced GTN achieves a 51% improvement for performance prediction of large-scale circuits compared to the GTN model without this strategy. These advancements establish GTN as a scalable framework for automated analog circuit design across varying circuit complexity levels.

Lu, Haoshu [New Jersey Institute of Technology (NJ↗

Modeling Framework for Bulk Electric Grid Impacts from HEMP E1 and E3 Effects (Tasks 3.1 Final Report)

This report presents a framework to evaluate the impact of a high-altitude electromagnetic pulse (HEMP) event on a bulk electric power grid. This report limits itself to modeling the impact of EMP E1 and E3 components. The co-simulation of E1 and E3 is presented in detail, and the focus of the paper is on the framework rather than actual results. This approach is highly conservative as E1 and E3 are not maximized with the same event characteristics and may only slightly overlap. The actual results shown in this report are based on a synthetic grid with synthetic data and a limited exemplary EMP model. The framework presented can be leveraged and used to analyze the impact of other threat scenarios, both manmade and natural disasters. This report d escribes a Monte-Carlo based methodology to probabilistically quantify the transient response of the power grid to a HEMP event. The approach uses multiple fundamental steps to characterize the system response to HEMP events, focused on the E1 and E3 components of the event. 1) Obtain component failure data related to HEMP events testing of components and creating component failure models. Use the component failure model to create component failure conditional probability density function (PDF) that is a function of the HEMP induced terminal voltage. 2) Model HEMP scenarios and calculate the E1 coupled voltage profiles seen by all system components. Model the same HEMP scenarios and calculate the transformer reactive power consumption profiles due to E3. 3) Sample each component failure PDF to determine which grid components will fail, due to the E1 voltage spike, for each scenario. 4) Perform dynamic simulations that incorporate the predicted component failures from E1 and reactive power consumption at each transformer affected by E3. These simulations allow for secondary transients to affect the relays/protection remaining in service which can lead to cascading outages. 5) Identify the locations and amount of load lost for each scenario through grid dynamic simulation. This can be an indication of the immediate grid impacts from a HEMP event. In addition, perform more detailed analysis to determine critical nodes and system trends. 6) To help realize the longer-term impacts, a security constrained alternating current optimal power flow (ACOPF) is run to maximize critical load served. This report describes a modeling framework to assess the systemic grid impacts due to a HEMP event. This stochastic simulation framework generates a large amount of data for each Monte Carlo replication, including HEMP location and characteristics, relay and component failures, E3 GIC profiles, cascading dynamics including voltage and frequency over time, and final system state. This data can then be analyzed to identify trends, e.g., unique system behavior modes or critical components whose failure is more likely to cause serious systemic effects. The proposed analysis process is demonstrated on a representative system. In order to draw realistic conclusions of the impact of a HEMP event on the grid, a significant amount of work remains with respect to modeling the impact on various grid components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Event-Driven Predictive Approach for Real-Time Volt/VAR control with CVR in solar PV rich Active Distribution Network

The focus of this paper is on analyzing the impact of conservation voltage reduction in the presence of active devices such as solar photovoltaic (PV) and developing controls that leverage these distributed energy resources. An event-driven predictive approach for real-time volt/volt-ampere reactive (VAR) optimization, along with local two-level adaptive volt/VAR droop-based control algorithm for advanced distribution management systems, is introduced. The methodology covers aggregated and autonomous controls under different timescale operations, including the impact and effect of unpredicted events such as cloud transients on PV power production. In addition, the control schemes include the uncertainties in PV power generation and load power demand. The proposed methodology is validated in a real-time framework using the real-time digital simulator platform through co-simulation with models based on Python and OpenDSS (Open Distribution System Simulator). The developed methodology is tested on the modified IEEE 123-feeder test system. The results reveal that the proposed methodology works well in the presence of high penetrations of PV power, produces significant energy savings, and mitigates over-/undervoltage problems.

14 SOLAR ENERGY↗

Demystifying the Stern layer at a metal–electrolyte interface: Local dielectric constant, specific ion adsorption, and partial charge transfer

Electric double layer (EDL) represents one of the most basic concepts in electrochemistry and is pertinent to diverse engineering applications ranging from electrocatalysis to energy storage. Whereas phenomenological and coarse-grained models have been long established to describe ionic distributions in the diffuse layer, a faithful prediction of the physicochemical properties of the electrode–electrolyte interface from a molecular perspective remains a daunting challenge. In this work, we investigate the charging behavior of an Ag (111) electrode in NaF aqueous solutions leveraging experimental results and theoretical calculations based on the classical density functional theory for ion distributions in the diffuse layer and on the joint density functional theory (JDFT) for the electronic structure. When the Ag electrode is applied with a negative voltage, the surface charge density can be reasonably described by assuming a neutral Stern layer with the dielectric constant dependent on the local electric field as predicted by the Kirkwood equation. However, the specific adsorption of F− ions must be considered when the electrode is positively charged and the fluoride adsorption can be attributed to both physical and chemical interactions. Qualitatively, F− binding and partial charge transfer are supported by JDFT calculations, which predict an increased binding energy as the voltage increases. Our findings shed insight on the molecular characteristics of the Stern layer and the charge behavior of adsorbed species not specified by conventional EDL models.

Wang, Xuepeng (ORCID:0000000285704546)↗

Formation of LiF Surface Layer During Direct Fluorination of High-Capacity Co-Free Disordered Rocksalt Cathodes

Disordered rocksalt (DRX) cathodes have attracted interest due to their high capacity and compositional flexibility (e.g., Co-free chemistries). However, the sloping voltage profile and gradual capacity fade during cycling have hindered widespread adoption of these materials. Simulations predict that fluorine substitution in DRX cathodes will improve their capacity, rate performance and cyclability. In this study we use a fluidized bed reactor to fluorinate a model Lirich DRX composition (Li1.15Ni0.375Ti0.375Mo0.1O2, NTMO) to investigate how fluorine content impacts the cathode’s structure and electrochemical performance. Instead of substituting O with F to form oxyfluoride phases, direct fluorination of DRX cathodes leads to formation of LiF surface films which improves the specific energy and capacity retention. This study demonstrates the feasibility of direct fluorination to improve the electrochemical performance of high voltage cathodes by tuning the material’s surface chemistry.

Co-free disordered rock-salt cathode, direct fluor↗

The Energy and Operational Impacts of Using 0-10V Control for LED Streetlights

Lighting systems have historically utilized either a proprietary control method, or one of a handful of standardized methods (e.g., 0-10V, DALI, DMX512) aimed at facilitating vendor interoperability. The utility and market success of the standardized methods has been limited for a variety of reasons. Although 0-10V is presently the most commonly available control interface for indoor and outdoor products in North America – even after the emergence of LED products and “connected lighting systems” with more modern network interfaces and luminaire-level sensors and intelligence – the use of 0-10V methods has significant tradeoffs. For instance, it is difficult to predict relative luminaire light output and input power at any particular control voltage, and performance across luminaires is inconsistent. This study characterizes 23 LED streetlights that claimed dimmability via a 0-10V interface, quantifies the performance variation found in market-available LED drivers, and explores the potential impact of the most recent 0-10V voluntary standard (ANSI C137.1-2022). Notably, the tested products were all manufactured prior to the release of this standard, and thus do not make compliance claims. Variation in response to 0-10V control voltages was expected to be more significant across different make/model luminaires than different units of the same make/model; the test population was structured based on this expectation. The 23 tested luminaires comprised 21 unique make/model streetlights from 14 different manufacturers. Three samples of one make/model streetlight were included in the test population to facilitate a limited exploration of unit-to-unit variation. The 21 unique make/model luminaires contained 20 unique make/model LED drivers from eight different driver manufacturers. Luminaire input power and current were measured at 11 control voltages (0.5 V and 1–10 V in 1 V increments).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Energy and Operational Impacts of Using 0-10V Control for LED Streetlights

LED lighting is becoming widely adopted and displacing most traditional lighting technologies. However, the traditional methods used to control light sources have not seen similar displacement. Lighting systems have historically utilized either a proprietary control method, or one of a handful of standardized methods (e.g., 0-10V, DALI, DMX512). The utility and market success of the standardized methods has been limited for a variety of reasons. Analog 0-10V methods have long been popular due to their simplicity and low cost of implementation and are presently the most commonly available control interface for indoor and outdoor LED products in North America. The emergence of “connected lighting systems” with more modern network interfaces and luminaire-level sensors and intelligence was anticipated by many to mark the beginning of the end of analog control. However, 0-10V interfaces continue to be prevalent with these more “digital” systems. The use of 0-10V methods has significant tradeoffs. 0-10V standards have historically not explicitly defined the relationship between the luminaire input control signal and output luminous flux for the full control signal range. As a result, it is difficult to predict relative luminaire light output and input power at any particular control voltage, and in practice the performance across LED drivers and the luminaires power is inconsistent. While this inconsistency has long been acknowledged by experts in the field, it is not accounted for in standard practice deployment, and end-users continue to regularly see unexpected and undesirable performance. It is hoped that the results from this study will help the lighting industry and standards developing organizations better understand and possibly resolve the shortcomings of 0-10V products, and consider what is best for the industry – additional incremental improvements to this fundamentally limited analog technology, or fully moving on to existing digital approaches, such as DALI D4i, that deliver accurate and consistent dimming performance across all luminaires in the system and thus guarantee the delivery of expected light levels, and energy and cost savings. Recommendations consistent with these goals are made to lighting and driver manufacturers, lighting software developers, standard developing organizations, and system designers and specifiers.

0-10V↗