Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage decay”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0νββ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0νββ of 136 Xe with projected half-life sensitivity of 1.35 x 10 28 yr. To reach this sensitivity, the design goal for nEXO is ≤1% energy resolution at the decay Q-value (2458.07 ± 0.31 keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q-value for the nEXO design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and production of the high voltage electrode grids and electron extraction region for the LZ dual-phase xenon time projection chamber

The dual-phase xenon time projection chamber (TPC) is a powerful tool for direct-detection experiments searching for WIMP dark matter, other dark matter models, and neutrinoless double-beta decay. Successful operation of such a TPC is critically dependent on the ability to hold high electric fields in the bulk liquid, across the liquid surface, and in the gas. Careful design and construction of the electrodes used to establish these fields is therefore required. We present the design and production of the LUX-ZEPLIN (LZ) experiment's high-voltage electrodes, a set of four woven mesh wire grids. Grid design drivers are discussed, with emphasis placed on design of the electron extraction region. Here, we follow this with a description of the grid production process and a discussion of steps taken to validate the LZ grids prior to integration into the TPC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Moderate active Fe 3+ doping enables improved cationic and anionic redox reactions for wide-voltage-range sodium storage

Layered metal oxides are promising cathode materials for sodium-ion batteries (SIBs) due to their high theoretical specific capacity and wide Na + diffusion channels. However, the irreversible phase transitions and cationic/anionic redoxes cause fast capacity decay. Herein, P2-type Na 0.67 Mg 0.1 Mn 0.8 Fe 0.1 O 2 (NMMF-1) cathode material with moderate active Fe 3+ doping has been designed for sodium storage. Uneven Mn 3+ /Mn 4+ distribution is observed in NMMF-1 and the introduction of Fe 3+ is beneficial for reducing the Mn 3+ contents both at the surface and in the bulk to alleviate the Jahn–Teller effect. The moderate Fe 3+ /Fe 4+ redox can realize the best tradeoff between capacity and cyclability. Therefore, the NMMF-1 demonstrates a high capacity (174.7 mAh g -1 at 20 mA g -1 ) and improved cyclability (78.5% over 100 cycles) in a wide-voltage range of 1.5–4.5 V (vs. Na + /Na). In-situ X-ray diffraction reveals a complete solid-solution reaction with a small volume change of 1.7% during charge/discharge processes and the charge compensation is disclosed in detail. This study will provide new insights into designing high-capacity and stable layered oxide cathode materials for SIBs.

25 ENERGY STORAGE↗

Realizing Complete Solid-Solution Reaction in High Sodium Content P2-Type Cathode for High-Performance Sodium-Ion Batteries

P2-type layered oxides suffer from an ordered Na + /vacancy arrangement and P2→O2/OP4 phase transitions, leading them to exhibit multiple voltage plateaus upon Na + extraction/insertion. The deficient sodium in the P2-type cathode easily induces the bad structural stability at deep desodiation states and limited reversible capacity during Na + de/insertion. These drawbacks cause poor rate capability and fast capacity decay in most P2-type layered oxides. In this work, to address these challenges, a novel high sodium content (0.85) and plateau-free P2-type cathode-Na 0.85 Li 0.12 Ni 0.22 Mn 0.66 O 2 (P2-NLNMO) was developed. The complete solid-solution reaction over a wide voltage range ensures both fast Na + mobility (10 -11 to 10 -10 cm 2 s -1 ) and small volume variation (1.7%). Furthermore, the high sodium content P2-NLNMO exhibits a higher reversible capacity of 123.4 mAhg -1 , superior rate capability of 79.3 mAhg -1 at 20 C, and 85.4% capacity retention after 500 cycles at 5 C. The sufficient Na and complete solid-solution reaction are critical to realizing high-performance P2-type cathodes for sodium-ion batteries.

25 ENERGY STORAGE↗

Electrostatic discharge test apparatus

Electrostatic discharge properties of materials are quantitatively measured and ranked. Samples are rotated on a turntable beneath selectable, co-available electrostatic chargers, one being a corona charging element and the other a sample-engaging triboelectric charging element. Samples then pass under a voltage meter to measure the amount of residual charge on the samples. After charging is discontinued, measurements are continued to record the charge decay history over time.

Smith, William Conrad↗

Conformal LiF Stabilized Interfaces via Electrochemical Fluorination on High Voltage Spinel Cathodes (≈4.9 V) for Lithium-Ion Batteries

The high voltage LiNi 0.5 Mn 1.5 O 4 (LNMO) spinel is one of the promising cathodes for the lithium-ion batteries due to its high energy densities, good rate performance. However, its high operating potential (≈4.75 V) causes extensive oxidation of conventional carbonate electrolytes, resulting an unstable and thick cathode electrolyte interphase (CEI) layer with a large irreversible capacity and low coulombic efficiency. In this work, we report the formation of thin LiF stabilized interfaces on LNMO via electrochemical fluorination that significantly improves the cycling stability and enhanced the capacity. An electrochemically induced conformal LiF layer acts as a part of a robust CEI by reducing the leakage of electrons and allowing the conduction of Li ions through it. Because of the robust LiF stabilized CEI, LNMO delivers a discharge capacity of ≈148.5 and ≈117.1 mAh g -1 at 0.1 and 1 C rate, respectively. It exhibits excellent cyclability with 80% capacity retention (CR) after 600 cycles in lithium-half cell and ≈90% CR after 200 cycles in full cell with only 0.03% and 0.05% capacity decay per cycle in conventional carbonate electrolytes without additives. Such an excellent electrochemical performance could lead to the potential development of high energy density batteries with high voltage cathodes for grid-based applications.

25 ENERGY STORAGE↗

A thermotropic liquid crystal enables efficient and stable perovskite solar modules

Perovskite solar cells have seen impressive progress in performance and stability, yet maintaining efficiency while scaling area remains a challenge. Here we find that additives commonly used to passivate large-area perovskite films often co-precipitate during perovskite crystallization and aggregate at interfaces, contributing to defects and to spatial inhomogeneity. Here we develop design criteria for additives to prevent their evaporative precipitation and enable uniform passivation of defects. We explored liquid crystals with melting point below the perovskite processing temperature, functionalization for defect passivation and hydrophobicity to improve device stability. We find that thermotropic liquid crystals such as 3,4,5-trifluoro-4'-(trans-4-propylcyclohexyl)biphenyl enable large-area perovskite films that are uniform, low in defects and stable against environmental stress factors. We demonstrate modules with a certified stabilized efficiency of 21.1% at an aperture area of 31 cm 2 and enhanced stability under damp-heat conditions (ISOS-D-3, 85% relative humidity, 85 °C) with T 86 (the duration for the efficiency to decay to 86% of the initial value) of 1,200 h, and reverse bias with (ISOS-V-1, negative maximum-power-point voltage) and without bypass diodes.

14 SOLAR ENERGY↗

High voltage delivery and distribution for the NEXT-100 Time Projection Chamber

A critical element in the realization of large liquid andgas time projection chambers (TPCs) is the delivery and distributionof high voltages into and around the detector. Such experimentsrequire of order tens of kilovolts to enable electron drift overmeter-scale distances. This paper describes the design andoperation of the cathode feedthrough and high voltage distributionthrough the field cage of the NEXT-100 experiment, an undergroundTPC that will search for neutrinoless double beta decay0νββ. The feedthrough has been demonstrated to holdpressures up to 20 bar and sustain voltages as high as -65 kV.The TPC is operating stably at its design high voltages. The systemhas been realized within the constraints of a stringent radiopuritybudget and is now being used to execute a suite of sensitive doublebeta decay analyses.

Adams, C. [Argonne]↗

A Data-Driven Passive Islanding Detection Scheme

This paper proposes a novel statistical parameters based data driven approach for passive islanding detection. The proposed scheme relies in the voltage data, measured at the point of common coupling, and is comprised of three stages. The Stage-1 quickly detects what is termed as coarse islanding, Stage-2 computes the decaying DC detector (DDCD), and 3) finally, the digital relay logic (DRL) is devised in Stage-3. The proposed scheme is tested as per the IEEE-1547, UL 1741 and IEC-62116 standards. Various tests are investigated on the modified IEEE-13 bus system, modeled in PSCAD/EMTDC, under stringent test scenarios such as power mismatch, induction motor starting effect, capacitor bank switching and various level of loads changes, considered for both single and multiple DG systems. The test results reveal that the proposed scheme can detect islanding in less than 2 cycles, and results in nearly zero non detection zone (NDZ). Also, the scheme can very well be used for single-phase microgrids too as it relies only on the single phase voltage information.

anti-islanding protection↗

Solid Polymer Electrolyte (SPE) fuel cell technology program

Many previously demonstrated improved fuel cell features were consolidated to (1) obtain a better understanding of the observed characteristics of the operating laboratory-sized cells; (2) evaluate appropriate improved fuel cell features in 0.7 sq ft cell hardware; and (3) study the resultant fuel cell capability and determine its impact on various potential fuel cell space missions. The observed performance characteristics of the fuel cell at high temperatures and high current densities were matched with a theoretical model based on the change in Gibbs free energy voltage with respect to temperature and internal resistance change with current density. Excellent agreement between the observed and model performance was obtained. The observed performance decay with operational time on cells with very low noble metal loadings (0.05 mg/sq cm) were shown to be related to loss in surface area. Cells with the baseline amount of noble catalyst electrode loading demonstrated over 40,000 hours of stable performance.

Source record↗

Electrostatic discharge test apparatus

Electrostatic discharge properties of materials are quantitatively measured and ranked. Samples (20) are rotated on a turntable (15) beneath selectable, co-available electrostatic chargers (30/40), one being a corona charging element (30) and the other a sample-engaging triboelectric charging element (40). They then pass under a voltage meter (25) to measure the amount of residual charge on the samples (20). After charging is discontinued, measurements are continued to record the charge decay history over time.

Smith, William C.↗

Laser Crystallization and Dopant Activation of a-Si:H Carrier-Selective Layer in TOPCon Si Solar Cells

Herein, we present a pulsed-laser processing method for crystallization and dopant activation of a highly n-doped amorphous silicon (a-Si:H) carrier-selective layer in a tunnel oxide passivated contact (TOPCon) Si solar cell structure. Here, the laser method provides enhanced conductivity and implied open circuit voltage while reducing emitter saturation current density and surface heating, as opposed to conventional high-temperature furnace annealing of the bulk Si wafer with a TOPCon structure. We identify an appropriate laser wavelength, fluence, and layer thickness using modeling and simulations. Raman and Hall effect measurements demonstrate increased crystallinity and dopant activation, whereas photoconductive decay shows enhanced surface and interface passivation quality. Additionally, we examine the role of subsequent SiNx deposition on further improving the passivation of laser-processed TOPCon layers to achieve a 5.9 kΩ/sq film sheet resistance, 2 ms effective carrier lifetime, 718 mV implied open-circuit voltage (iVOC), and 8.6 fA/cm 2 one-side recombination current density (J0) with the potential for further passivation improvement via laser process and a-Si layer thickness optimization.

14 SOLAR ENERGY↗

Calibration and Performance of Germanium High Voltage Detectors for SuperCDMS SNOLAB

As SuperCDMS SNOLAB is getting ready to search for low mass dark matter particles, using cryogenic Ge and Si detectors, a set of six of the new SuperCDMS High Voltage (HV) detectors (four Ge and two Si) were tested in the Cryogenic Underground TEst facility (CUTE) at SNOLAB. This provided the first opportunity to gain experience with this new detector type and assess their performance thoroughly under low background conditions. Here we describe the SuperCDMS HV detector concept and discuss some of the newly developed analysis methods and approaches. Focusing on the Ge detectors, we investigate the detector performance under voltage bias (up to 90 V), exercise the low energy (keV to sub-keV range) calibration based on the electron capture peaks generated by the decay of $^{71}$Ge, assess the detector resolution, and demonstrate the unexpected (and encouraging) ability of these detectors to also measure high energy interactions in the hundreds of keV range with good resolution (better than 3% at 356 keV).

Albakry, M. F. [British Columbia U.; TRIUMF]↗

Eddy Current Method for Fatigue Testing

Flux-focusing electromagnetic sensor using a ferromagnetic flux-focusing lens simplifies inspections and increases detectability of fatigue cracks and material loss in high conductivity material. A ferrous shield isolates a high-turn pick-up coil from an excitation coil. Use of the magnetic shield produces a null voltage output across the receiving coil in presence of an unflawed sample. Redistribution of the current flow in the sample caused by the presence of flaws. eliminates the shielding condition and a large output voltage is produced, yielding a clear unambiguous flaw signal. Maximum sensor output is obtained when positioned symmetrically above the crack. By obtaining position of maximum sensor output, it is possible to track the fault and locate the area surrounding its tip. Accuracy of tip location is enhanced by two unique features of the sensor; a very high signal-to-noise ratio of the probe's output resulting in an extremely smooth signal peak across the fault, and a rapidly decaying sensor output outside a small area surrounding the crack tip enabling the search region to be clearly defined. Under low frequency operation, material thinning due to corrosion causes incomplete shielding of the pick-up coil. Low frequency output voltage of the probe is therefore a direct indicator of thickness of the test sample. Fatigue testing a conductive material is accomplished by applying load to the material, applying current to the sensor, scanning the material with the sensor, monitoring the sensor output signal, adjusting material load based on the sensor output signal of the sensor, and adjusting position of the sensor based on its output signal.

Simpson, John W.↗

Characterization of NTD germanium and ion-implanted Si bolometers at 0.3K and 0.1K

Bolometer elements were built and tested using NTD germanium and ion-implanted Si thermometer elements. The thermal links were made using aluminum wires and NbC(x)N(y) coated carbon fibers. The temperature dependence of the detector resistance, lead thermal conductivity, and heat capacity were measured. The dependence of the detector resistance on applied electric field was also measured. This, combined with the current-voltage curve for the detector, allowed the calculation of the detector responsivity. Known amounts of energy were deposited into the detector by allowing X-rays from the decay of Fe-55 to be thermalized in the detector. In the best-measured case, the predicted pulse height/measured height was 1.04 + or - .05. The noise at frequencies above 25 Hz in the NTD Ge was near that predicted by thermodynamics. The noise below 25 Hz has a 1/f character and may be in the carbon fiber/bolometer junction. The implanted detectors show some 1/f noise which depends on the total thermometer volume. Comparison between noise measurements and theory will be presented.

Moseley, H.↗

Variations in the electrical short-circuit current decay for recombination lifetime and velocity measurements

An improved measurement system for electrical short-circuit current decay is presented that extends applicability of the method to silicon solar cells having an effective lifetime as low as 1 microsec. The system uses metal/oxide/semiconductor transistors as voltage-controlled switches. Advances in theory developed here increase precision and sensitivity in the determination of the minority-carrier recombination lifetime and recombination velocity. A variation of the method, which exploits measurements made on related back-surface field and back-ohmic contact devices, further improves precision and sensitivity. The improvements are illustrated by application to 15 different silicon solar cells.

Jung, Tae-Won↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Flux-focusing eddy current probe and method for flaw detection

A flux-focusing electromagnetic sensor which uses a ferromagnetic flux-focusing lens simplifies inspections and increases detectability of fatigue cracks and material loss in high conductivity material is presented. The unique feature of the device is the ferrous shield isolating a high-turn pick-up coil from an excitation coil. The use of the magnetic shield is shown to produce a null voltage output across the receiving coil in the presence of an unflawed sample. A redistribution of the current flow in the sample caused by the presence of flaws, however, eliminates the shielding condition and a large output voltage is produced, yielding a clear unambiguous flaw signal. The maximum sensor output is obtained when positioned symmetrically above the crack. Hence, by obtaining the position of the maximum sensor output, it is possible to track the fault and locate the area surrounding its tip. The accuracy of tip location is enhanced by two unique features of the sensor; a very high signal-to-noise ratio of the probe's output which results in an extremely smooth signal peak across the fault, and a rapidly decaying sensor output outside a small area surrounding the crack tip which enables the region for searching to be clearly defined. Under low frequency operation, material thinning due to corrosion damage causes an incomplete shielding of the pick-up coil. The low frequency output voltage of the probe is therefore a direct indicator of the thickness of the test sample.

Simpson, John W.↗