Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ventilators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Evaluation of H-Canyon Ventilation Exhaust Tunnel Inspection at the Savannah River Site - 20052

The Department of Energy (DOE) H-Canyon Facility at the Savannah River Site (SRS) is operated by Savannah River Nuclear Solutions (SRNS). The Facility Structural Integrity Program [1] provides a process to inspect, evaluate, and document the conditions of passive safety related structural systems and components, their degradation mechanisms and their impact on the safety envelope. The Structural Integrity Program performs periodic visual inspections to confirm the systems and components can perform their safety function and recommend corrective actions before the function is compromised. The H-Canyon Exhaust Tunnel is part of the H-Canyon Ventilation System and is periodically inspected under the Structural Integrity Program. The Tunnel performs a Safety Class passive design feature function that is available 100% of the time. The underground reinforced concrete Tunnel directs Canyon process air from the Canyon to the Sand Filter System. The radiological and chemical airborne activity coupled with the physical configuration of the tunnel precludes a manned entry into the tunnel to perform the inspection. Unlike active systems that can be subjected to physical testing to confirm capability, qualification calculations, including modeling, is performed to assess passive design feature capabilities relative to operational, accident and natural phenomena hazards events. Input for these calculations come from knowledge of field conditions, design drawings and conservative assumptions. The knowledge of field conditions comes from concrete and soil testing activities as well as inspection data. The use of cameras on crawlers to obtain inspection data and how that data is used in qualification calculations is the focus of this discussion. Remote Tunnel inspections have been performed using cameras on a stick, referred to as pole cameras, prior to Calendar Year 2003 (CY2003). Since CY2003, six camera equipped crawlers have been used. Crawlers have evolved and improved by incorporating lessons learned from the previous inspections. The latest 2019 crawler successfully traveled the entire length of the tunnel between the Canyon and Sand Filter System and captured images that were previously unseen, thus providing key visual data for the Structural Integrity Program report [2]. The inspection data serves as 1) input to qualification calculations, 2) validates current conditions remain bounded by qualification calculations, and 3) documents a record of change over time. This data is vital for the effective evaluation of the tunnel structure and aids with predicting the life cycle service life safety envelope to protect the public, environment, and facility worker. The goal of the 2019 deployment was to use a more robust vehicle to ensure travel over obstacles, perform the inspection with higher resolution cameras, and have the ability to elevate the cameras to view surfaces previously obscured by abandon-in-place ducts in the tunnel. The inspection information will serve to strengthen the input basis for qualification calculations, versus using excessive conservative calculation assumptions. This 2019 inspection was compared with previous crawler visual evidence to identify change over time to project remaining service life and confirm field conditions remain bounded by qualification calculations. The results of the 2019 Exhaust Tunnel inspection continue to improve and provide a firm basis to make sound engineering judgements regarding tunnel capability and approaches in projecting remaining service life with an aging system and component. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model predictive control for integrated control of air-conditioning and mechanical ventilation, lighting and shading systems

Modern buildings are increasingly automated and often equipped with multiple building services (e.g., air-conditioning and mechanical ventilation (ACMV), dynamic shading, dimmable lighting). These systems are conventionally controlled individually without considering their interactions, affecting the building’s overall energy inefficiency and occupant comfort. A model predictive control (MPC) system that features a multi-objective MPC scheme to enable coordinated control of multiple building services for overall optimized energy efficiency, indoor thermal and visual comfort, as well as a hybrid model for predicting indoor visual comfort and lighting power is proposed. The MPC system was implemented in a test facility having two identical, side-by-side experimental cells to facilitate comparison with a building management system (BMS) employing conventional reactive feedback control. The MPC system coordinated the control of the ACMV, dynamic façade and automated dimmable lighting systems in one cell while the BMS controlled the building services in the other cell in a conventional manner. The MPC side achieved 15.1–20.7% electricity consumption reduction, as compared to the BMS side. Simultaneously, the MPC system improved indoor thermal comfort by maintaining the room within the comfortable range (-0.5 < predicted mean vote < 0.5) for 98.3% of the time, up from 91.8% of the time on the BMS side. Visual comfort, measured by indoor daylight glare probability (DGP) and horizontal illuminance level at work plane height, was maintained for the entire test period on the MPC side, improving from having visual comfort for 94.5% and 85.7% of the time, respectively, on the BMS side.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utilizing commercial heating, ventilating, and air conditioning systems to provide grid services: A review

The modern power grid faces multiple challenges due to an increase in the adoption of renewable generation, such as dynamically balancing supply and demand at different time scales. Demand side management in buildings plays a vital role in achieving this balance because buildings can provide grid services through a variety of building assets. However, the development of grid-interactive, efficient buildings is still in its infancy, and a systematic and holistic understanding of grid service delivery strategies in terms of energy efficiency, load shifting, load shedding and load modulating is still limited. This paper is a comprehensive review of the development and application of building-level control strategies for utilizing heating, ventilating, and air conditioning systems to provide grid services. These strategies have been investigated through numerical and experimental studies. Control algorithms, such as heuristic rule-based control and model-based control, have been used to enable the automatic control delivery of grid services. The advantages and disadvantages of the strategies are summarized and discussed. Finally, research trends are also identified, which include considering predicted mean vote-based and occupant-based thermal comfort, modeling of occupant behavior, integrating power grid operations with building control, and combining different demand flexibility modes in the control design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Size dependent infectivity of SARS-CoV-2 via respiratory droplets spread through central ventilation systems

In this work, we evaluate the transport of respiratory droplets that carry SARS-CoV-2 through central air handling systems in multiroom buildings. Respiratory droplet size modes arise from the bronchioles representing the lungs and lower respiratory tract, the larynx representing the upper respiratory tract including vocal cords, or the oral cavity. The size distribution of each mode remains largely conserved, although the magnitude of each droplet mode changes as infected individuals breathe, speak, sing, laugh, cough, and sneeze. Here we evaluate how each type of respiratory droplet transits through central ventilation systems and the implications thereof for infectivity of COVID-19. We find that while larger oral droplets can transmit through the air handling systems, their size and concentration are greatly reduced with but few oral droplets leaving the source room. In contrast, the smaller droplets that originate from the bronchioles and larynx are much more effective in transiting through the air handling system into connected rooms. This suggests that the ratio of lower respiratory or deep lung infections may increase relative to upper respiratory infections in rooms connected by central air handling systems. Also, increasing the temperature and humidity in the range considered after the droplets have achieved an “equilibrium” size reduces the probability of infection.

60 APPLIED LIFE SCIENCES↗

Model predictive control of heating, ventilation, and air conditioning (HVAC) systems: A state-of-the-art review

Due to the fast advancement of communication and information technology, intelligent buildings have garnered great interest. These buildings can forecast weather, ambient temperature, and sun irradiation and can modify heating, ventilation, and air conditioning (HVAC) operations appropriately, based on current and previous data. This change is intended to reduce HVAC system energy usage while maintaining an appropriate degree of thermal comfort and indoor air quality. Since its inception, model predictive control (MPC) has been one of the prospective solutions for HVAC management systems to reduce both costs and energy usage. Additionally, MPC is becoming increasingly practical as the processing capacity of building automation systems increases and a large quantity of monitored building data becomes available. MPC also provides the potential to improve the energy efficiency of HVAC systems via its capacity to consider limitations, to predict disruptions, and to factor in multiple competing goals such as interior thermal comfort and building energy consumption. Although substantial research has been conducted on MPC in building HVAC systems, there is a shortage of critical reviews and a lack of a comprehensive framework that formulates and defines the applications. Here, this article provides a comprehensive state-of-the-art overview of MPC in HVAC systems. Detailed discussions of modeling approaches and optimization algorithms are included. Numerous design aspects such as prediction horizon, occupancy behavior, building type, and cost function, that impact MPC performance are discussed in detail. The technical characteristics, advantages, and disadvantages of various types of modeling software are discussed. The primary objective of this work is to highlight critical design characteristics for the MPC control scheme and to give improved suggestions for future research. Moreover, numerous prospective scenarios have been suggested that might provide future research direction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mitigation of ventilation air methane (VAM) using novel methanotrophic coating materials: a technical analysis

Abstract Ventilation air methane (VAM) is a potent greenhouse gas source originating from geological wells, current and extinct mineshafts and other terrestrial conduits venting methane to the atmosphere, contributing to global methane emissions and disproportionate warming potential. Herein, we introduce the concept of the methanotrophic material as an engineering solution. Such materials should be capable of converting methane at ambient temperatures and pressures to a binder product, capturing and permanently sequestering the methane while simultaneously restricting its further emission. While such materials are currently under research development, this goal is supported and facilities by the mathematical framework, introduced and used herein, to evaluate the ability to convert methane, using currently published activity data. We include a case study of the conversion of a characteristic stream of VAM (0.6% methane in air, 1.7 × 10 8 l hr −1 equivalent to 100 000 standard cubic feet per minute). We show that when appropriately designed, such systems require a surface coverage of less than 1000 m of mine tunnel length (equivalent to 20 000 m 2 areal coverage) in order to reduce the methane emission from this stream by over 99%. Finally, we highlight formaldehyde as a reactive intermediate of methane oxidation which may itself be incorporated into these coating materials. As a component of binders and polymers already used ubiquitously in commercial products, this intermediate ultimately allows these systems to sequester the carbon from methane in a stable and solid form. The results presented here are easily extended to the treatment of other methane streams—either more concentrated or dilute—and the results herein will guide the design and development of a new class of carbon-negative materials.

Environmental Sciences & Ecology↗

COVID-19 Exposure Assessment Tool (CEAT): Exposure quantification based on ventilation, infection prevalence, group characteristics, and behavior

The coronavirus disease 2019 (COVID-19) Exposure Assessment Tool (CEAT) allows users to compare respiratory relative risk to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) for various scenarios, providing understanding of how combinations of protective measures affect risk. CEAT incorporates mechanistic, stochastic, and epidemiological factors including the (i) emission rate of virus, (ii) viral aerosol degradation and removal, (iii) duration of activity/exposure, (iv) inhalation rates, (v) ventilation rates (indoors/outdoors), (vi) volume of indoor space, (vii) filtration, (viii) mask use and effectiveness, (ix) distance between people (taking into account both near-field and far-field effects of proximity), (x) group size, (xi) current infection rates by variant, (xii) prevalence of infection and immunity in the community, (xiii) vaccination rates, and (xiv) implementation of COVID-19 testing procedures. CEAT applied to published studies of COVID-19 transmission events demonstrates the model’s accuracy. We also show how health and safety professionals at NASA Ames Research Center used CEAT to manage potential risks posed by SARS-CoV-2 exposures.

60 APPLIED LIFE SCIENCES↗

Ultra-Low SWaP CO 2 Sensing for Demand Control Ventilation (Final Report)

In this project PARC and Energy ETC aimed to develop an ultra-low cost, size, weight, and power (SWaP) printed CO 2 sensor system for occupancy detection to enable Demand Control Ventilation (DCV) on a per-room basis. The CO 2 sensor technology is based on the temperature variation when CO 2 reversibly physisorbs to a highly conductive and high surface area sorbent surface, and is compatible with integration with PARC innovations in printed sensors and flexible electronics, for which PARC is a globally leading research center. The printed CO 2 sensor itself is designed to be compatible with PARC’s “peel-and-stick” platform of ultra-low power, low-cost, distributed sensors, and to facilitate real-time DCV based on overall indoor air quality (IAQ). Previously, PARC has developed flexible hybrid electronics (FHE) compatible materials to measure humidity, temperature, light, strain, and gases such as carbon monoxide, methane, ammonia, and hydrogen sulfide. Through this project, PARC developed FHE-compatible materials to measure CO 2 . Thus, with one <$15 FHE “peel-and-stick” based sensor node, a building management system (BMS) will be able to capture a complete picture of the indoor environment. This includes IAQ, light, temperature, and other comfort factors that impact building operations. Combined with optimized DCV, this low-cost sensor capability can be a key enabler of annual primary energy savings of ~ 0.3-0.4 Quad in commercial buildings while ensuring healthy IAQ. Energy ETC is a leader in supplier-agnostic BMS deployments and will design the commissioning and deployment procedures to maximize system interoperability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Qualification of ANSI/HPS N13.1-2011 Mixing Criteria by Computational Fluid Dynamics Modeling for the 3430 Building Fan Addition and Increased Ventilation Capacity

Additional ventilation capacity has been designed for the 3430 Building filtered exhaust stack system. The updated system will increase the number of fans from two to three and include new ductwork with a larger diameter to integrate the new fan into the existing stack. Stack operations will involve running various fan combinations at any given time. The air monitoring system of the existing two-fan stack previously was found to comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard. Full-scale, three-dimensional computational fluid dynamics (CFD) modeling was used to evaluate the modified three-fan system for compliance with the ANSI/HPS N13.1-2011 standard, which essentially is equivalent to the ANSI/HPS N13.1-1999 standard. The four mixing criteria evaluated are 1) flow angle, 2) velocity, 3) gas tracer, and 4) particle tracer. Benchmarking of the CFD modeling methodology showed good agreement with previous testing used to qualify the stack, and modeling of the existing two-fan system showed good agreement with test data collected from the 3430 Building stack. Modeling was performed to develop a suitable three-fan design. Initial modeling of the three-fan design and basic ductwork showed that flow angles and velocity uniformity were acceptable; however, the gas tracer and particle tracer mixing results were not acceptable. To meet ANSI/HPS N13.1-2011 criteria, an air blender was added to the stack design.

42 ENGINEERING↗

Qualification of ANSI/HPS N13.1-2011 Mixing Criteria by Computational Fluid Dynamics Modeling for the 3430 Building Fan Addition and Increased Ventilation Capacity

Additional ventilation capacity has been designed for the 3430 Building filtered exhaust stack system. The updated system will increase the number of fans from two to three and include new ductwork with a larger diameter to integrate the new fan into the existing stack. Stack operations will involve running various fan combinations at any given time. The air monitoring system of the existing two-fan stack previously was found to comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard. Full-scale, three-dimensional computational fluid dynamics (CFD) modeling was used to evaluate the modified three-fan system for compliance with the ANSI/HPS N13.1-2011 standard, which essentially is equivalent to the ANSI/HPS N13.1-1999 standard. The four mixing criteria evaluated are 1) flow angle, 2) velocity, 3) gas tracer, and 4) particle tracer. Benchmarking of the CFD modeling methodology showed good agreement with previous testing used to qualify the stack, and modeling of the existing two-fan system showed good agreement with test data collected from the 3430 Building stack. Modeling was performed to develop a suitable three-fan design. Initial modeling of the three-fan design and basic ductwork showed that flow angles and velocity uniformity were acceptable; however, the gas tracer and particle tracer mixing results were not acceptable. To meet ANSI/HPS N13.1-2011 criteria, an air blender was added to the stack design. This revision models the individual maximum fan reduced flow capacity from 38,000 cfm to 31,200 cfm; no changes to the duct design are made.

42 ENGINEERING↗

Numerical Simulation Studies of Ultrasonic De-Icing for Heating, Ventilation, Air Conditioning, and Refrigeration Structures

Ice accumulation on heating, ventilation, air conditioning, and refrigeration (HVACR) structures presents significant operational challenges. These challenges include reduced efficiency, increased energy consumption, and potential damage to equipment. Traditional de-icing methods, such as chemical treatments, mechanical scraping, or heating-based techniques, are often labor-intensive, costly, and environmentally harmful. Here, this study uniquely investigates ultrasonic de-icing as an energy-efficient alternative for HVACR applications, focusing on the specific structural geometries found in these systems. A comprehensive numerical simulation framework was developed using finite element analysis to explore ultrasonic wave propagation across four distinct HVACR structures. Key parameters such as ultrasonic frequency, power levels, and the number and placement of actuators were examined for their impact on ice detachment efficiency. Results from simulations on a plate structure reveal that ultrasonic excitation can propagate effectively across large areas (at least 150 × 150 mm), enhancing the de-icing coverage. Lower frequency (e.g., 30 to 45 kHz) excitation results in greater displacement, improving de-icing performance, while increased actuator numbers with the same total power input also enhance effectiveness. Two actuators seem sufficient for the de-icing of a 300 × 300 mm plate. For tube-and-fin structures, specific high-power ultrasonic frequencies selectively excite the fin plates, demonstrating efficient ice removal when actuated on the tube. However, optimal performance requires careful design of actuator placement and vibration modes to accommodate the irregular shapes of these structures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Digital simulation and experimental evaluation of the CO2-H(plus) control of pulmonary ventilation

Previous models of the CO2-H(+) control of ventilation have been concerned either with the response to CO2 inhalation, or the response to perfusion of the surface of the medulla with mock cerebrospinal fluid having a high P sub CO2. Simulation of both responses with the same model has not been attempted. The purpose of the present study was two fold; first to develop such a model and, second, to obtain experimental data from human subjects for both developing this model and for evaluating this and future models.

Milhorn, H. T., Jr.↗

Computation of wall effects in ventilated transonic wind tunnels.

A method for computing interference effects due to ventilated wind-tunnel walls on lifting transonic airfoils is presented. Differences between the present method based on nonlinear transonic theory and the classical correction formulae from linear subsonic theory are discussed. Computed results are presented for an NACA 0012 in solid and perforated wall tunnels. The solid wall calculations are compared with data.

Murman, E. M.↗