Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ventilation rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Rescue Shuttle Flight Re-Entry: Controlling Astronaut Thermal Exposure

A rescue mission for the STS-125 Hubble Telescope Repair Mission requires reentry from space with 11 crew members aboard, exceeding past cabin thermal load experience and risking crew thermal stress potentially causing cognitive performance and physiological decrements. The space shuttle crew cabin air revitalization system (ARS) was designed to support a nominal crew complement of 4 to 7 crew and 10 persons in emergencies, all in a shirt-sleeve environment. Subsequent to the addition of full pressure suits with individual cooling units, the ARS cannot maintain a stable temperature in the crew cabin during reentry thermal loads. Bulk cabin thermal models, used for rescue mission planning and analysis of crew cabin air, were unable to accurately represent crew workstation values of air flow, carbon dioxide, and heat content for the middeck. Crew temperature models suggested significantly elevated core temperatures. Planning for an STS-400 potential rescue of seven stranded crew utilized computational fluid dynamics (CFD) models to demonstrate inhomogeneous cabin thermal properties and improve analysis compared to bulk models. In the absence of monitoring of crew temperature, heart rate, metabolic rate and incomplete engineering data on the performance of the integrated cooling garment/cooling unit (ICG/CU) at cabin temperatures above 75 degrees F, related systems & models were reevaluated and tests conducted with humans in the loop. Changes to the cabin ventilation, ICU placement, crew reentry suit-donning procedures, Orbiter Program wave-off policy and post-landing power down and crew extraction were adopted. A second CFD and core temperature model incorporated the proposed changes and confirmed satisfactory cabin temperature, improved air distribution, and estimated core temperatures within safe limits. CONCLUSIONS: These changes in equipment, in-flight and post-landing procedures, and policy were implemented for the STS-400 rescue shuttle & will be implemented in any future rescue flights from the International Space Station of stranded shuttle crews.

Gillis, David B.↗

Grey-box and ANN-based building models for multistep-ahead prediction of indoor temperature to implement model predictive control

Model-based predictive control (MPC) strategies for heating, ventilation, and air-conditioning (HVAC) systems present an opportunity to lower building energy consumption and operational costs. Such approaches rely on the development of a model to precisely forecast building thermal dynamics, such as room air temperature or heating/cooling rate, and make control-related decisions. The control-oriented modeling of building energy systems should be accurate in predicting indoor conditions and present low computational complexity. These features are the key challenge of implementing advanced control methods such as MPC. Extant studies on building modeling for MPC have focused on step-ahead forecasting techniques to forecast building thermal dynamics, while multistep-ahead forecasting is essential. Moreover, machine learning model suitable in case of the domain-based engineering expertise are also not available. To this aim, we perform a comparative analysis of the grey-box model based on a resistance-capacitance (RC) thermal network and a machine learning model composed of an artificial neural network (ANN) for multistep-ahead prediction of building thermal dynamics using current and historical data. Actual experimental data obtained from the Flexible Research Platform (FRP) in Oak Ridge National Laboratory (US) are used for estimation and validation purposes. The average root mean squared error (RMSE) of the grey-box and ANN models are 0.89 °C and 1.02°C, respectively. Finally, the results indicate that the grey-box model outperforms the ANN model in the considered validation periods in terms of accuracy and prediction stability.

42 ENGINEERING↗

Contributions of microgravity test results to the design of spacecraft fire-safety systems

Experiments conducted in spacecraft and drop towers show that thin-sheet materials have reduced flammability ranges and flame-spread rates under quiescent low-gravity environments (microgravity) compared to normal gravity. Furthermore, low-gravity flames may be suppressed more easily by atmospheric dilution or decreasing atmospheric total pressure than their normal-gravity counterparts. The addition of a ventilating air flow to the low-gravity flame zone, however, can greatly enhance the flammability range and flame spread. These results, along with observations of flame and smoke characteristics useful for microgravity fire-detection 'signatures', promise to be of considerable value to spacecraft fire-safety designs. The paper summarizes the fire detection and suppression techniques proposed for the Space Station Freedom and discusses both the application of low-gravity combustion knowledge to improve fire protection and the critical needs for further research.

Friedman, Robert↗

Fan Performance Testing and Oxygen Compatibility Assessment Results for Future Space Suit Life Support Systems

An advanced portable life support system (PLSS) for the space suit will require a small, robust, and energy-efficient system to transport the ventilation gas through the space suit for lunar Extravehicular Activity (EVA) operations. A trade study identified and compared ventilation transport technologies in commercial, military, and space applications to determine which technologies could be adapted for EVA use. Based on the trade study results, five commercially available, 24volt fans were selected for performance testing at various pressures and flow rates. Measured fan parameters included fan delta-pressures, input voltages, input electrical currents, and in some cases motor windings electrical voltages and currents. In addition, a follow-on trade study was performed to identify oxygen compatibility issues and assess their impact on fan design. This paper outlines the results of the fan performance characterization testing, as well as the results from the oxygen compatibility assessment.

Jennings, Mallory A.↗

Contributions of Microgravity Test Results to the Design of Spacecraft Fire Safety Systems

Experiments conducted in spacecraft and drop towers show that thin-sheet materials have reduced flammability ranges and flame-spread rates under quiescent low-gravity environments (microgravity) as compared to normal gravity. Furthermore, low-gravity flames may be suppressed more easily by atmospheric dilution or decreasing atmospheric total pressure than their normal-gravity counterparts. The addition of a ventilating air flow to the low-gravity flame zone, however, can greatly enhance the flammability range and flame spread. These results, along with observations of flame and smoke characteristics useful for microgravity fire-detection 'signatures', promise to be of considerable value to spacecraft fire-safety designs. The paper summarizes the fire detection and suppression techniques proposed for the Space Station Freedom and discusses both the application of low-gravity combustion knowledge to improve fire protection and the critical needs for further research.

Friedman, Robert↗

Evaluation of medical treatments to increase survival of ebullism in guinea pigs

Spaceflight carriers run a constant risk of exposure to vacuum. Above 63,000 ft (47 mmHg), the ambient pressure falls below the vapor pressure of water at 37 C, and tissue vaporization (ebullism) begins. Little is know about appropriate resuscitative protocols after such an ebullism exposure. This study identified injury patterns and mortality rates associated with ebullism while verifying effectiveness of traditional pulmonary resuscitative techniques. Male Hartley guinea pigs were exposed to 87,000 ft for periods of 40 to 115 sec. After descent, those animals that did not breathe spontaneously were given artificial ventilation by bag and mask for up to 15 minutes. Those animals surviving were randomly assigned to one of three treatment groups--hyperbaric oxygen (HBO), ground-level oxygen (GLO2), and ground-level air (GLAIR). The HBO group was treated on a standard treatment table 6A while the GLO2 animals received O2 for an equivalent length of time. Those animals in the GLAIR group were observed only. All surviving animals were humanely sacrified at 48 hours. Inflation of the animal's lungs after the exposure was found to be difficult and, at times, impossible. This may be due to surfactant disruption at the alveolar lining. Electron microscopy identified a disruption of the surfactant layer in animals that did not survive initial exposure. Mortality was found to increase with exposure time: 40 sec--0 percent; 60 sec--6 percent; 70 sec--40 percent; 80 sec--13 percent; 100 sec--38 percent; 110 sec--40 percent; and 115 sec--100 percent. There was no difference in the delayed mortality among the treatment groups (HBO--15 percent, GLO2--11 percent, GLAIR--11 percent). However, since resuscitation was ineffective, the effectiveness of any post-exposure treatment was severely limited. Preliminary results indicate that reuscitation of guinea pigs following ebullism exposure is difficult, and that current techniques (such as traditional CPR) may not be appropriate.

Stegmann, Barbara J.↗

Fan Performance Testing and Oxygen Compatibility Assessment Results for Future Space Suit Life Support Systems

An advanced portable life support system (PLSS) for the space suit will require a small, robust, and energyefficient system to transport the ventilation gas through the space suit for lunar Extravehicular Activity (EVA) operations. A trade study identified and compared ventilation transport technologies in commercial, military, and space applications to determine which technologies could be adapted for EVA use. Based on the trade study results, five commercially available, 24-volt fans were selected for performance testing at various pressures and flow rates. Measured fan parameters included fan delta-pressures, input voltages, input electrical currents, and in some cases motor windings electrical voltages and currents. In addition, a follow-on trade study was performed to identify oxygen compatibility issues and assess their impact on fan design. This paper outlines the results of the fan performance characterization testing, as well as the results from the oxygen compatibility assessment.

Paul, Heather L.↗

Results of the Trace Contaminant Control Needs Evaluation and Sizing Study for Space Suit Life Support Development

The Trace Contaminant Control System (TCCS), located within the ventilation loop of the Portable Life Support System (PLSS) of the Constellation Space Suit Element (CSSE), is responsible for removing hazardous trace contaminants from the space suit ventilation flow. This paper summarizes the results of a trade study that evaluated if trace contaminant control could be accomplished without a TCCS, relying on suit leakage, ullage loss from the carbon dioxide and humidity control system, and other factors. Trace contaminant generation rates were revisited to verify that values reflect the latest designs for CSSE pressure garment materials and PLSS hardware. Additionally, TCCS sizing calculations were performed and a literature survey was conducted to review the latest developments in trace contaminant technologies.

Paul, Heather L.↗

Requirements and Sizing Investigation for Constellation Space Suit Portable Life Support System Trace Contaminant Control

The Trace Contaminant Control System (TCCS), located within the ventilation loop of the Constellation Space Suit Portable Life Support System (PLSS), is responsible for removing hazardous trace contaminants from the space suit ventilation flow. This paper summarizes the results of a trade study that evaluated if trace contaminant control could be accomplished without a TCCS, relying on suit leakage, ullage loss from the carbon dioxide and humidity control system, and other factors. Trace contaminant generation rates were revisited to verify that values reflect the latest designs for Constellation Space Suit System (CSSS) pressure garment materials and PLSS hardware. Additionally, TCCS sizing calculations were performed and a literature survey was conducted to review the latest developments in trace contaminant technologies.

Paul, Heather L.↗

Computational Aerodynamic Simulations of a Spacecraft Cabin Ventilation Fan Design

Quieter working environments for astronauts are needed if future long-duration space exploration missions are to be safe and productive. Ventilation and payload cooling fans are known to be dominant sources of noise, with the International Space Station being a good case in point. To address this issue cost effectively, early attention to fan design, selection, and installation has been recommended, leading to an effort by NASA to examine the potential for small-fan noise reduction by improving fan aerodynamic design. As a preliminary part of that effort, the aerodynamics of a cabin ventilation fan designed by Hamilton Sundstrand has been simulated using computational fluid dynamics codes, and the computed solutions analyzed to quantify various aspects of the fan aerodynamics and performance. Four simulations were performed at the design rotational speed: two at the design flow rate and two at off-design flow rates. Following a brief discussion of the computational codes, various aerodynamic- and performance-related quantities derived from the computed flow fields are presented along with relevant flow field details. The results show that the computed fan performance is in generally good agreement with stated design goals.

Tweedt, Daniel L.↗

Acoustic Measurements of an Uninstalled Spacecraft Cabin Ventilation Fan Prototype

Sound pressure measurements were recorded for a prototype of a spacecraft cabin ventilation fan in a test in the NASA Glenn Acoustical Testing Laboratory. The axial fan is approximately 0.089 m (3.50 in) in diameter and 0.223 m (9.00 in) long and has nine rotor blades and eleven stator vanes. At design point of 12,000 rpm, the fan was predicted to produce a flow rate of 0.0709 m3/s (150 cfm) and a total pressure rise of 925 Pa (3.72 in. of water) at 12,000 rpm. While the fan was designed to be part of a ducted atmospheric revitalization system, no attempt was made to throttle the flow or simulate the installed configuration during this test. The fan was operated at six speeds from 6,000 rpm to 13,500 rpm. A 13-microphone traversing array was used to collect sound pressure measurements along two horizontal planes parallel to the flow direction, two vertical planes upstream of the fan inlet and two vertical planes downstream of the fan exhaust. Measurements indicate that sound at blade passing frequency harmonics contribute significantly to the overall audible noise produced by the fan at free delivery conditions.

fan↗

Results from On-Board CSA-CP and CDM Sensor Readings During the Burning and Suppression of Solids II (BASS-II) Experiment in the Microgravity Science Glovebox (MSG)

For the first time on ISS, BASS-II utilized MSG working volume dilution with gaseous nitrogen (N2). We developed a perfectly stirred reactor model to determine the N2 flow time and flow rate to obtain the desired reduced oxygen concentration in the working volume for each test. We calibrated the model with CSA-CP oxygen readings offset using the Mass Constituents Analyzer reading of the ISS ambient atmosphere data for that day. This worked out extremely well for operations, and added a new vital variable, ambient oxygen level, to our test matrices. The main variables tested in BASS-II were ambient oxygen concentration, ventilation flow velocity, and fuel type, thickness, and geometry. BASS-II also utilized the on-board CSA-CP for oxygen and carbon monoxide readings, and the CDM for carbon dioxide readings before and after each test. Readings from these sensors allow us to evaluate the completeness of the combustion. The oxygen and carbon dioxide readings before and after each test were analyzed and compared very well to stoichiometric ratios for a one step gas-phase reaction. The CO versus CO2 followed a linear trend for some datasets, but not for all the different geometries of fuel and flow tested. Lastly, we calculated the heat release rates during each test from the oxygen consumption and burn times, using the constant 13.1 kJ of heat released per gram of oxygen consumed. The results showed that the majority of the tests had heat release rates well below 100 Watts.

combustion products↗

Thermal Conductivity of a Novel Salt-Hydrogel Complex as a Phase Change Material for Building Thermal Management

Use of electricity for space heating, ventilation and air conditioning in buildings may be better managed through temporary energy storage. Compared with electrochemical storage, the levelized cost of thermal energy storage systems can be lower depending on geographical location and thermophysical properties [1]. In any phase change material (PCM), the rate of absorption and release of thermal energy increases with higher thermal conductivity [2]. However, leading PCMs like paraffin waxes have thermal conductivities on the order of 0.1 W/mK. Glauber’s salt, a salt hydrate, possesses a relatively high thermal conductivity but suffers from supercooling and phase segregation. Research has shown that polymer-based composites with salt hydrates can prevent phase segregation and limit supercooling over hundreds of cycles [3] though the thermal conductivity of the composite may be reduced leading to low energy storage rates. Here, we report thermal conductivity measurements on polymer hydrogels which are stable in solutions of Glauber’s salt. To measure thermal conductivity of soft gels, we use a 3-omega method [4] where heat flows bidirectionally through a substrate below and through a gel placed on top. This suits measurements of both gels and liquids unlike transient plane heat source or transient hot wire methods. We report measurements of thermal conductivity of salt-hydrogel complexes as a function of temperature, cross-linking and salt concentration. In addition, we present modeling of thermal conductivity of sodium sulfate solutions with available theories. We finally employ polarized optical microscopy to observe inside the transparent hydrogel networks, showing that precipitating crystals may influence thermal conductivity measurements for high salt concentrations. Our thermal conductivity results combined with enthalpy of phase change, mass density and specific heat are essential to accurately design thermal storage systems for energy-efficient buildings.

composite, thermal conductivity↗

Simple Wins: Driving Effective Implementation of Energy Efficiency Projects

Small- and medium-sized manufacturers (SMMs) in the United States, making up over 98% of manufacturing firms, account for 48.3% of the sector’s energy consumption. Despite access to energy assessments and technical resources, such as those from the US Department of Energy’s Better Plants program and Industrial Training and Assessment Centers, implementation rates for identified energy-saving measures remain lower than expectations, averaging 47%. Some barriers were identified by other researchers as limited workforce capacity, inadequate training, and time constraints hinder progress. This article studied the development of customized checklists together with the energy assessment report as a practical solution to improve implementation rates for energy efficiency projects among SMMs. The framework for the checklists was grounded in five principles: short, precise, actionable, relevant, and codeveloped (SPARC). A case study of a 500,000-squarefoot SMM demonstrates how tailored checklists targeting significant energy users—such as heating, ventilating and air conditioning (HVAC), lighting, and compressed air systems for this facility—can simplify the process for staff to do facility walkthroughs to monitor best practices and track the progress of energy efficiency project implementation.

Guo, Wei [Oak Ridge National Laboratory (ORNL), Oa↗

Improving the representation of isopycnal mixing in E3SM (Final Report)

The DOE-supported Energy Exascale Earth System Model (E3SM) is a major attempt by the Department of Energy to develop a new Earth System Model using unstructured grids, which allow for the model to concentrate resolution where it is most needed and avoid numerical artifacts experienced by previous Earth System Models (ESMs) using regular grids in which the lateral resolution becomes extremely fine as the resolution shrinks at the poles. This effort required rewriting many of the algorithms previously developed for regular grids. One algorithm that was problematic in the first version of E3SM was the representation of mixing due to turbulent ocean eddies with scales smaller than the model grid. These mesoscale eddies are the primary way by which tracers are stirred along density surfaces in the ocean interior. In particular, the process of isopycnal mixing exchanges fresher, more oxygenated waters from polar regions with saltier, nutrient-rich and oxygen poor waters from tropical regions. Previous work in our group has shown that this mechanism is vitally important for bringing oxygen into poorly ventilated tropical regions (Gnanadesikan et al., 2012, 2013) and plays a significant role in determining the uptake of anthropogenic carbon dioxide (Gnanadesikan et al., 2015). However, in E3SMv1 this process was turned off, as turning it on caused the model to become unstable. Additionally, the rate of isopycnal mixing is directly proportional to a mixing coefficient $A_{Redi}$ whose value varies from less than 400 m 2 /s to 2000 m 2 /s across contemporary climate models. The main thrusts of this proposal therefore were to: 1.) Improve the numerics of isopycnal mixing in E3SM; 2.) Identify ways in which climate models are sensitive to the isopycnal mixing coefficient; and 3.) Develop better representations of the isopycnal mixing coefficient.

54 ENVIRONMENTAL SCIENCES↗

Ventilation loss and pressurization in the NASA launch/entry suit: Potential for heat stress

The potential of the NASA Launch/Entry Suit (LES) for producing heat stress in a simulated Space Shuttle cabin environment was studied. The testing was designed to identify potential heat stress hazards if the LES were pressurized or if ventilation were lost. Conditions were designed to simulate an extreme pre-launch situation with chamber temperatures maintained at dry bulb temperature = 27.2 +/- 0.1 C, globe temperature = 27.3 +/- 0.1 C, and wet bulb temperature = 21.1 +/- 0.3 C. Two females and two males, 23 to 34 years of age, were employed in this study, with two subjects having exposures in all 3 conditions. Test durations in the ventilated (V) and unventilated (UV) conditions were designed for 480 minutes, which all subjects achieved. Pressurized runs (Pr) were designed for 45 minutes, which all subjects also achieved. While some significant differences related to experimental conditions were noted in rectal and mean skin temperatures, evaporation rates, sweat rates, and heart rate, these differences were not thought to be physiologically significant. The results indicate that the LES garment, in either the Pr or UV state, poses no danger of inducing unacceptable heat stress under the conditions expected within the Space Shuttle cabin during launch or reentry.

Kaufman, Jonathan W.↗

Burning and Suppression of Solids–II (BASS-II) Summary Report

The Burning and Suppression of Solids (BASS) experiment hardware is a small flow duct that provides containment for small scale burning of solid samples within the Microgravity Science Glovebox (MSG) aboard the International Space Station (ISS). A video camera with a data overlay and a 35-mm still camera record the combustion events. The controls (ignition, fan speed, etc.) are operated by an astronaut while the principal investigator team monitors the experiment from the ground and communicates directly with the astronaut. For the first time on ISS, BASS–II utilized MSG working volume dilution with gaseous N2. We developed a perfectly stirred reactor model to determine the N2 flow time and flow rate to obtain the desired reduced O2 concentration in the working volume for each test. We calibrated the model with the Compound Specific Analyzer-Combustion Products (CSA-CP) O2 readings offset using the Major Constituents Analyzer reading of the ISS ambient atmosphere data for that day. This worked out extremely well for operations, and added a new vital variable, ambient O2 level, to our test matrices. The main variables tested in BASS–II were ambient O2 concentration, ventilation flow velocity, and fuel type, thickness, and geometry. BASS–II also utilized the onboard CSA-CP for O2 and CO readings, and the Carbon Dioxide Monitor for CO2 readings before and after each test. Readings from these sensors allow us to evaluate the completeness of the combustion. The O2 and CO2 readings before and after each test were analyzed and compared very well to stoichiometric ratios for a one-step gas-phase reaction. The CO versus CO2 followed a linear trend for some datasets, but not for all the different geometries of fuel and flow tested. We calculated the heat release rates during each test from the O2 consumption and burn times, using the constant 13.1 kJ of heat released per gram of O2 consumed. The results showed that most of the tests had heat release rates well below 100 W. Lastly, the global equivalence ratio for the tests is estimated to be fuel rich, 1.3 on average using mass loss and O2 consumption data.

Microgravity↗

System and method for characterization of air leakage in building using data from communicating thermostats and/or interval meters

Systems and methods for characterization of retrofit opportunities are described. Some embodiments are directed to methods for determining the air leakage rate of a building, and accordingly, for determining suitability of sealing of air leaks to improve the energy efficiency of a building. The methods may comprise computing, using at least one computing device disposed remote from a building and based at least in part on heating, ventilation and air conditioning (HVAC) runtime data associated with the building, one or more thermal characteristics of the building. The HVAC runtime data may be computed based on data received from a thermostat or a meter, such as an electric or a gas meter. To isolate the impact of air leakage, subsets of the HVAC runtime data at time intervals selected to have substantially the same conditions, but different wind speeds, may be computed.

Zeifman, Michael↗