Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

DFF Layout Variations in CMOS SOI—Analysis of Hardening by Design Options

Four D flip-flop (DFF) layouts were created from the same schematic in Sandia National Laboratories’ CMOS7 silicon-on-insulator (SOI) process. Single-event upset (SEU) modeling and testing showed an improved response with the use of shallow (not fully bottomed) N-type metal-oxide-semiconductor field-effect transistors (NMOSFETs), extending the size of the drain implant and increasing the critical charge of the transmission gates in the circuit design and layout. This research also shows the importance of correctly modeling nodal capacitance, which is a major factor determining SEU critical charge. Accurate SEU models enable the understanding of the SEU vulnerabilities and how to make the design more robust.

42 ENGINEERING↗

Long-time variation in magnetic structure of Ce(Ir x Rh 1– x ) 3 Si 2 : A new interpretation of time variation

Here, to clarify the key factor for the slow magnetic transitions in CeIr 3 Si 2 and other materials, magnetization and neutron scattering measurements have been carried out on the system Ce(Ir x Rh 1–x ) 3 Si 2 . In this system, a magnetic phase transition is accomplished through slow and fast processes. The fractions of these processes vary with the chemical composition x . A new interpretation of magnetic phase transitions, which includes the coexistence of two processes, is presented.

36 MATERIALS SCIENCE↗

Monitoring Global Sea Level: Eustatic Variations, Local Variations, and Solid Earth Effects

Project BIFROST (Baseline Inferences for Fennoscandian Rebound Observations. Sea-level and Tectonics) combines networks of continuously operating CPS receivers in Sweden and Finland to measure ongoing crustal deformation due to glacial isostatic adjustment, (CIA). We present an analysis of data collected in the years 1993-1998. We compare the CPS determinations of three-dimensional crustal motion to predictions calculated using the high resolution Fennoscandian deglaciation model recently proposed by Lambeck et al. We find that the the maximum observed uplift rate (approx. 10 mm/ yr) and the maximum predicted uplift rate agree to better than 1 mm/ yr. The patterns of uplift also agree quite well, although differences are discernible. The chi(exp 2) difference between predicted and GPS-observed radial rates is reduced by a factor of 5-6 compared to that for the "null" (no uplift) model, depending on whether a mean difference is first removed. The north components of velocity agree at about the same relative level. whereas the agreement for the east components is worse, a problem possibly related to the lack of bias fixing. We have also compared the values for the observed radial deformation rates to those based on sea-level rates from Baltic tide gauges. The weighted RMS difference between CPS and tide-gauge rates (after removing a mean) is 0.6 mm/ yr, giving an indication of the combined accuracy of the CPS and tide-gauge measurement systems. Spectral analysis of the time series of position estimates yields spectral indices in the range -1 to -2. An EOF analysis indicates, however, that much of this power is correlated among the sites. The correlation appears to be regional and falls off only slightly with distance. Some of this correlated noise is associated with snow accumulation on the antennas or, for those antennas with radomes, on the radomes. This problem has caused us to modify the radomes used several times, leading to one of our more significant sources of uncertainty.

Davis, James L.↗

Influence of glucocorticoids on time-of-day-dependent variations in IgE-, histamine-, and platelet-activating factor-mediated systemic anaphylaxis in different mouse strains

Highlights: • Daily variations in systemic anaphylaxis differed among inbred mouse strains. • The daily variations differed with anaphylaxis-inducing substances. • Glucocorticoid-dependent and -independent mechanisms regulated the variations. A time-of-day-dependent variation in IgE-mediated passive systemic anaphylaxis was previously reported in ICR mice. In the present study, we investigated time-of-day-dependent variations in IgE-, histamine-, and platelet-activating factor (PAF)-mediated systemic anaphylaxis in C57BL/6, BALB/c, and NC/Nga mice at 9:00 h and 21:00 h, and evaluated the potential influence of glucocorticoids (GCs) on these variations. We found significant time-of-day-dependent variations in IgE-mediated systemic anaphylaxis in C57BL/6 mice, and in histamine- and PAF-mediated systemic anaphylaxis in BALB/c mice. Significant daily variations in IgE-, histamine-, and PAF-mediated systemic anaphylaxis were not observed in NC/Nga mice. Pretreatment with dexamethasone and adrenalectomy abolished the daily variations in IgE-mediated systemic anaphylaxis in C57BL/6 mice and in PAF-mediated systemic anaphylaxis in BALB/c mice, suggesting that GCs from adrenal glands are pivotal in regulating these variations. In contrast, pretreatment with dexamethasone and adrenalectomy did not abolish the daily variation in histamine-mediated systemic anaphylaxis in BALB/c mice, suggesting that GC-independent and adrenal gland-independent mechanisms are important for the variation. The present study demonstrated that time-of-day-dependent variations in systemic anaphylaxis differed among inbred mouse strains and with anaphylaxis-inducing substances. Thus, mouse strains, time of experiment, and anaphylaxis-inducing substances used must be considered to obtain appropriate experimental results.

60 APPLIED LIFE SCIENCES↗

DISSECTING THE RED SEQUENCE. III. MASS-TO-LIGHT VARIATIONS IN THREE-DIMENSIONAL FUNDAMENTAL PLANE SPACE

The fundamental plane (FP) of early-type galaxies is observed to have finite thickness and to be tilted from the virial relation. Both of these represent departures from the simple assumption that dynamical mass-to-light ratios (M{sub dyn}/L) are constant for all early-type galaxies. We use a sample of 16,000 quiescent galaxies from the Sloan Digital Sky Survey to map out the variations in M {sub dyn}/L throughout the three-dimensional FP space defined by velocity dispersion ({sigma}), effective radius (R{sub e}), and effective surface brightness (I{sub e}). Dividing M{sub dyn}/L into multiple components allows us to separately consider the contribution to the observed M{sub dyn}/L variation due to stellar population effects, initial mass function (IMF) variations, and variations in the dark matter fraction within one R{sub e} . Along the FP, we find that the stellar population contribution given some constant IMF (M{sub *,IMF}/L) scales with {sigma} such that M{sub *,IMF}/L {proportional_to} f({sigma}). Meanwhile, the dark matter and/or IMF contribution (M{sub dyn}/M {sub *,IMF}) scales with M{sub dyn} such that M{sub dyn}/M {sub *,IMF} {proportional_to} g(M{sub dyn}). This means that the two contributions to the tilt of the FP rotate the plane around different axes in the three-dimensional space. The observed tilt of the FP requires contributions from both, with dark matter/IMF variations likely comprising the dominant contribution. Looking at M {sub dyn}/L variations through the thickness of the FP, we find that M{sub dyn}/L variations must be dominated either by IMF variations or by real differences in the dark matter fraction with R{sub e} . This means that the finite thickness of the FP is due to variations in the stellar mass surface density within R{sub e} ({Sigma}{sub *,IMF}), not the fading of passive stellar populations. It therefore represents genuine structural differences between early-type galaxies. These structural variations are correlated with galaxy star formation histories such that galaxies with higher M{sub dyn}/M {sub *,IMF} have higher [Mg/Fe], lower metallicities, and older mean stellar ages. We discuss several physical mechanisms that might explain the observed co-variation between M {sub dyn}/M {sub *,IMF} and galaxy star formation histories. It is difficult to explain the observed enhancement of {alpha}-elements in lower-surface-brightness galaxies by allowing the IMF to vary. Differences in dark matter fraction can be produced by variations in the 'conversion efficiency' of baryons into stars or by the redistribution of stars and dark matter through dissipational merging. The former explanation, specifically a model in which some galaxies experience low conversion efficiencies due to premature truncation of star formation, provides a more natural explanation for the co-variation of M{sub dyn}/M {sub *,IMF} and the observed stellar population properties.

79 ASTRONOMY AND ASTROPHYSICS↗

Model and Standard Operating Procedures Supporting Signal Variation Flow Graph Analysis

This document will describe the principles of the Signal Variation Flow Technique, and the uncertainty models generated using it. We focus on the capture of the variation between the ideal signal and the measured signal. The ideal signal is defined to represent the signal output of a system whose full state behavior is known, with no variation in environment or during operation, and whose photons trajectories are not modified by the object. A CT uncertainty analysis is the result of two main steps. First, the radiography regime extends from the source to the collected image, which is 2D in the case of standard CT. This maps all upstream uncertainties into the variation observed on the radiograph and captures all variation in the physical domain. Second, the reconstruction regime extends from the captured images to the reconstructed 3D image. This regime is purely in the mathematical domain and corrects reconstruction algorithm artifacts/anomalies. The present work focuses on building the model through the radiography regime. The reconstruction regime is expected to be largely a study of algorithmic sensitivity, requiring the definition of a range of standardized tests through which the algorithms would be run. Radiographic variation would then be mapped through reconstruction sensitivities to predict the signal variation in the final image. An incomplete list for the reconstructed image variation output basis includes voxel density, edge blur and length variation, in analogous fashion to the basis functions presented in this work. The signal variation occurs in several forms at the radiograph. These forms are gathered into a complete basis set of functions describing all variation on the radiograph. The scale of each basis function is calculated independently via a specific SVFG. This includes 0D pixel noise (0DI), 0D energy noise (0DE), 1D blur (1DB), 1D length (1DL) or 2D position (2DP). These models are orthogonal in that they each explore a space in the signal variation domain that cannot be reached by the other basis functions. The variation basis functions, and associated SVFG models are split by output dimensionality, a term loosely used for categorization, and explained further below.

42 ENGINEERING↗

SU-E-T-408: Evaluation of the Type and Frequency of Variations Discovered During Routine Secondary Patient Chart Review

Purpose: Desire to improve efficiency and throughput inspired a review of our physics chart check procedures. Departmental policy mandates plan checks pre-treatment, after first treatment and weekly every 3–5 days. This study examined the effectiveness of the “after first” check with respect to improving patient safety and clinical efficiency. Type and frequency of variations discovered during this redundant secondary review was examined over seven months. Methods: A community spreadsheet was created to record variations in care discovered during chart review following the first fraction of treatment and before the second fraction (each plan reviewed prior to treatment). Entries were recorded from August 2014 through February 2015, amounting to 43 recorded variations out of 906 reviewed charts. The variations were divided into categories and frequencies were assessed month-to-month. Results: Analysis of recorded variations indicates an overall variation rate of 4.7%. The initial rate was 13.5%; months 2–7 average 3.7%. The majority of variations related to discrepancies in documentation at 46.5%, followed by prescription, plan deficiency, and dose tracking related variations at 25.5%, 12.8%, and 12.8%, respectively. Minor variations (negligible consequence on patient treatment) outweighed major variations 3 to 1. Conclusion: This work indicates that this redundant secondary check is effective. The first month spike in rates could be due to the Hawthorne/observer effect, but the consistent 4% variation rate suggests the need for periodical re-training on variations noted as frequent to improve awareness and quality of the initial chart review process, which may lead to improved treatment quality, patient safety and increased clinical efficiency. Utilizing these results, a continuous quality improvement process following Deming’s Plan-Do-Study-Act (PDSA) methodology was generated. The first iteration of this PDSA was adding a specific dose tracking checklist item in the pre-treatment plan check assessment; the ramification of which will be assessed in future data.

60 APPLIED LIFE SCIENCES↗

Influence of Design Variations on Systems Performance

High-risk aerospace components have to meet very stringent quality, performance, and safety requirements. Any source of variation is a concern, as it may result in scrap or rework. poor performance, and potentially unsafe flying conditions. The sources of variation during product development, including design, manufacturing, and assembly, and during operation are shown. Sources of static and dynamic variation during development need to be detected accurately in order to prevent failure when the components are placed in operation. The Systems' Health and Safety (SHAS) research at the NASA Ames Research Center addresses the problem of detecting and evaluating the statistical variation in helicopter transmissions. In this work, we focus on the variations caused by design, manufacturing, and assembly of these components, prior to being placed in operation (DMV). In particular, we aim to understand and represent the failure and variation information, and their correlation to performance and safety and feed this information back into the development cycle at an early stage. The feedback of such critical information will assure the development of more reliable components with less rework and scrap. Variations during design and manufacturing are a common source of concern in the development and production of such components. Accounting for these variations, especially those that have the potential to affect performance, is accomplished in a variety ways, including Taguchi methods, FMEA, quality control, statistical process control, and variation risk management. In this work, we start with the assumption that any of these variations can be represented mathematically, and accounted for by using analytical tools incorporating these mathematical representations. In this paper, we concentrate on variations that are introduced during design. Variations introduced during manufacturing are investigated in parallel work.

Tumer, Irem Y.↗

Poster - 33: Dosimetry Comparison of Prone Breast Forward and Inverse Treatment planning considering daily setup variations

Introduction: The purpose of this study is to investigate the effects of daily setup variations on prone breast forward field-in-field (FinF) and inverse IMRT treatment planning. Methods: Rando Phantom (Left breast) and Pixy phantom (Right breast) were built and CT scanned in prone position. The treatment planning (TP) is performed in Eclipse TP system. Forward FinF plan and inverse IMRT plan were created to satisfy the CTV coverage and OARs criteria. The daily setup variations were assumed to be 5 mm at left-right, superior-inferior, and anterior-posterior directions. The DVHs of CTV coverage and OARs were compared for both forward FinF plan and inverse IMRT plans due to 5mm setup variation. Results and Discussions: DVHs of CTV coverage had fewer variations for 5m setup variation for forward FinF and inverse IMRT plan for both phantoms. However, for the setup variations in the left-right direction, the DVH of CTV coverage of IMRT plan showed the worst variation due to lateral setup variation for both phantoms. For anterior-posterior variation, the CTV could not get full coverage when the breast chest wall is shallow; however, with the guidance of MV imaging, breast chest wall will be checked during the MV imaging setup. So the setup variations have more effects on inverse IMRT plan, compared to forward FinF plan, especially in the left-right direction. Conclusions: The Forward FinF plan was recommended clinically considering daily setup variation.

60 APPLIED LIFE SCIENCES↗

Dosimetric effects of rotational output variation and x-ray target degradation on helical tomotherapy plans

In this study, two potential sources of IMRT delivery error have been identified for helical tomotherapy delivery using the HiART system (TomoTherapy, Inc., Madison, WI): Rotational output variation and target degradation. The HiArt system is known to have output variation, typically about {+-}2%, due to the absence of a dose servo system. On the HiArt system, x-ray target replacement is required approximately every 10-12 months due to target degradation. Near the end of target life, the target thins and causes a decrease in the beam energy and a softening of the beam profile at the lateral edges of the beam. The purpose of this study is to evaluate the dosimetric effects of rotational output variation and target degradation by modeling their effects and incorporating them into recalculated treatment plans for three clinical scenarios: Head and neck, partial breast, and prostate. Models were created to emulate both potential sources of error. For output variation, a model was created using a sine function to match the amplitude ({+-}2%), frequency, and phase of the measured rotational output variation data. A second model with a hypothetical variation of {+-}7% was also created to represent the largest variation that could exist without violating the allowable dose window in the delivery system. A measured beam profile near the end of target life was used to create a modified beam profile model for the target degradation. These models were then incorporated into the treatment plan by modifying the leaf opening times in the delivery sinogram. A new beam model was also created to mimic the change in beam energy seen near the end of target life. The plans were then calculated using a research version of the PLANNED ADAPTIVE treatment planning software from TomoTherapy, Inc. Three plans were evaluated in this study: Head and neck, partial breast, and prostate. The D{sub 50} of organs at risk, the D{sub 95} for planning target volumes (PTVs), and the local dose difference were used to evaluate the changes in the modified treatment plans. Dosimetric effects from rotational variation were found to be low (less than 1%) for a typical variation of {+-}2%. Even using a variation of {+-}7%, DVH values and dose distributions were altered by less than 2% for all scenarios. The dosimetric effects of target degradation were found to be slightly more significant. For a model using data taken just before target failure, dosimetric differences of 2%-4% were observed in the recalculated plans when compared to the original plans. The largest effects (up to 4.5%) were observed for PTVs that were located at deeper depths as seen in the prostate plan. Overall, the recalculated plans show that the dosimetric effects of rotational variation and target degradation are on the order of 1%-4% for helical tomotherapy on the HiART system and do not pose a risk for significant deviations from the original treatment plan.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multi-decadal river flow variations in France

In this article, multi-decadal variations in the French hydroclimate are investigated, with a specific focus on river flows. Based on long observed series, it is shown that river flows in France generally exhibit large multi-decadal variations in the instrumental period (defined in this study as the period from the late 19th century to the present), especially in spring. Differences of means between 21 yr periods of the 20th century as large as 40% are indeed found for many gauging stations. Multi-decadal spring river flow variations are associated with variations in spring precipitation and temperature. These multi-decadal variations in precipitation are themselves found to be driven by large-scale atmospheric circulation, more precisely by a multi-decadal oscillation in a sea level pressure dipole between western Europe and the eastern Atlantic. It is suggested that the Atlantic Multidecadal Variability, the main mode of multi-decadal variability in the North Atlantic–Europe sector, controls those variations in large-scale circulation and is therefore the main ultimate driver of multi-decadal variations in spring river flows. Potential multi-decadal variations in river flows in other seasons, and in particular summer, are also noted. As they are not associated with significant surface climate anomalies (i.e. temperature, precipitation) in summer, other mechanisms are investigated based on hydrological simulations. The impact of climate variations in spring on summer soil moisture, and the impact of soil moisture in summer on the runoff-to-precipitation ratio, could potentially play a role in multi-decadal summer river flow variations. The large amplitude of the multi-decadal variations in French river flows suggests that internal variability may play a very important role in the evolution of river flows during the next decades, potentially temporarily limiting, reversing or seriously aggravating the long-term impacts of anthropogenic climate change.

54 ENVIRONMENTAL SCIENCES↗

Small-Scale Density Variations in the Lunar Crust Revealed by GRAIL

Data from the Gravity Recovery and Interior Laboratory (GRAIL) mission have revealed that approximately 98 percent of the power of the gravity signal of the Moon at high spherical harmonic degrees correlates with the topography. The remaining 2 percent of the signal, which cannot be explained by topography, contains information about density variations within the crust. These high-degree Bouguer gravity anomalies are likely caused by small-scale (10's of km) shallow density variations. Here we use gravity inversions to model the small-scale three-dimensional variations in the density of the lunar crust. Inversion results from three non-descript areas yield shallow density variations in the range of 100-200 kg/m3. Three end-member scenarios of variations in porosity, intrusions into the crust, and variations in bulk crustal composition were tested as possible sources of the density variations. We find that the density anomalies can be caused entirely by changes in porosity. Characteristics of density anomalies in the South Pole-Aitken basin also support porosity as a primary source of these variations. Mafic intrusions into the crust could explain many, but not all of the anomalies. Additionally, variations in crustal composition revealed by spectral data could only explain a small fraction of the density anomalies. Nevertheless, all three sources of density variations likely contribute. Collectively, results from this study of GRAIL gravity data, combined with other studies of remote sensing data and lunar samples, show that the lunar crust exhibits variations in density by plus or minus 10 percent over scales ranging from centimeters to 100’s of kilometers.

J C Jansen↗