LONG-TERM PERFORMANCE OF SOLID OXIDE STACKS WITH ELECTRODE-SUPPORTED CELLS OPERATING IN THE STEAM ELECTROLYSIS MODE

Performance characterization and durability testing have been completed on two five-cell high-temperature electrolysis stacks constructed with advanced cell and stack technologies. The solid oxide cells incorporate a negative-electrode-supported multi-layer design with nickel-zirconia cermet negative electrodes, thin-film yttria-stabilized zirconia electrolytes, and multi-layer lanthanum ferrite-based positive electrodes. The per-cell active area is 100 cm2. The stack is internally manifolded with compliant mica-glass seals. Treated metallic interconnects with integral flow channels separate the cells. Stack compression is accomplished by means of a custom spring-loaded test fixture. Initial stack performance characterization was determined through a series of DC potential sweeps in both fuel cell and electrolysis modes of operation. Results of these sweeps indicated very good initial performance, with area-specific resistance values less than 0.5 ?.cm2. Long-term durability testing was performed with A test duration of 1000 hours. Overall performance degradation was less than 10% over the 1000-hour period. Final stack performance characterization was again determined by a series of DC potential sweeps at the same flow conditions as the initial sweeps in both electrolysis and fuel cell modes of operation. A final sweep in the fuel cell mode indicated a power density of 0.356 W/cm2, with average per-cell voltage of 0.71 V at a current of 50 A.

08 HYDROGEN↗

Effects of lipid concentration on anaerobic co-digestion of municipal biomass wastes

Highlights: • Lipid in municipal biomass would not inhibited the anaerobic digestion process. • A lipid concentration of 65% of total VS was the inhibition concentration. • The amount of Brevibacterium decreased with the increasing of the lipid contents. • Long chain fatty acids stacked on the methanogenic bacteria and blocked the mass transfer process. - Abstract: The influence of the lipid concentration on the anaerobic co-digestion of municipal biomass waste and waste-activated sludge was assessed by biochemical methane potential (BMP) tests and by bench-scale tests in a mesophilic semi-continuous stirred tank reactor. The effect of increasing the volatile solid (VS) concentration of lipid from 0% to 75% was investigated. BMP tests showed that lipids in municipal biomass waste could enhance the methane production. The results of bench-scale tests showed that a lipids concentration of 65% of total VS was the inhibition concentration. Methane yields increased with increasing lipid concentration when lipid concentrations were below 60%, but when lipid concentration was set as 65% or higher, methane yields decreased sharply. When lipid concentrations were below 60%, the pH values were in the optimum range for the growth of methanogenic bacteria and the ratios of volatile fatty acid (VFA)/alkalinity were in the range of 0.2–0.6. When lipid concentrations exceeded 65%, the pH values were below 5.2, the reactor was acidized and the values of VFA/alkalinity rose to 2.0. The amount of Brevibacterium decreased with increasing lipid content. Long chain fatty acids stacked on the methanogenic bacteria and blocked the mass transfer process, thereby inhibiting anaerobic digestion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Forecasting constraints on the mean free path of ionizing photons at z ≥ 5.4 from the Lyman-α forest flux autocorrelation function

ABSTRACT Fluctuations in Lyman-α (Ly α) forest transmission towards high-z quasars are partially sourced from spatial fluctuations in the ultraviolet background, the level of which are set by the mean free path of ionizing photons (λmfp). The autocorrelation function of Ly α forest flux characterizes the strength and scale of transmission fluctuations and, as we show, is thus sensitive to λmfp. Recent measurements at z ∼ 6 suggest a rapid evolution of λmfp at z > 5.0 which would leave a signature in the evolution of the autocorrelation function. For this forecast, we model mock Ly α forest data with properties similar to the XQR-30 extended data set at 5.4 ≤ z ≤ 6.0. At each z, we investigate 100 mock data sets and an ideal case where mock data matches model values of the autocorrelation function. For ideal data with λmfp = 9.0 cMpc at z = 6.0, we recover $\lambda _{\text{mfp}}=12^{+6}_{-3}$ cMpc. This precision is comparable to direct measurements of λmfp from the stacking of quasar spectra beyond the Lyman limit. Hypothetical high-resolution data leads to a $\sim 40~{{\ \rm per\ cent}}$ reduction in the error bars over all z. The distribution of mock values of the autocorrelation function in this work is highly non-Gaussian for high-z, which should caution work with other statistics of the high-z Ly α forest against making this assumption. We use a rigorous statistical method to pass an inference test, however future work on non-Gaussian methods will enable higher precision measurements.

Astronomy & Astrophysics↗

Electron-beam-induced current measurements with applied bias provide insight to locally resolved acceptor concentrations at p-n junctions

Electron-beam-induced current (EBIC) measurements have been employed for the investigation of the local electrical properties existing at various types of electrical junctions during the past decades. In the standard configuration, the device under investigation is analyzed under short-circuit conditions. Further insight into the function of the electrical junction can be obtained when applying a bias voltage. The present work gives insight into how EBIC measurements at applied bias can be conducted at the submicrometer level, at the example of CuInSe{sub 2} solar cells. From the EBIC profiles acquired across ZnO/CdS/CuInSe{sub 2}/Mo stacks exhibiting p-n junctions with different net doping densities in the CuInSe{sub 2} layers, values for the width of the space-charge region, w, were extracted. For all net doping densities, these values decreased with increasing applied voltage. Assuming a linear relationship between w{sup 2} and the applied voltage, the resulting net doping densities agreed well with the ones obtained by means of capacitance-voltage measurements.

36 MATERIALS SCIENCE↗

Magnetic characteristics of a high-layer-number NiFe/FeMn multilayer

We report the static and dynamic magnetic characteristics of a high-layer-number NiFe/FeMn multilayer test structure with potential applications in broadband absorber and filter devices. To allow fine control over the absorption linewidths and to understand the mechanisms governing the resonances in a tailored structure similar to that expected to be used in real world applications, the multilayer was intentionally designed to have layer thickness and interface roughness variations. Magnetometry measurements show that the sample has complex hysteresis loops with features consistent with single ferromagnetic film reversals. Characterisation by transmission electron microscopy allows us to correlate the magnetic properties with structural features, including the film widths and interface roughnesses. Analysis of resonance frequencies from broadband ferromagnetic resonance measurements as a function of field magnitude and orientation provide values of the local exchange bias, rotatable anisotropy, and uniaxial anisotropy fields for specific layers in the stack and explain the observed mode softening. The linewidths of the multilayer are adjustable around the bias field, approaching twice that seen at larger fields, allowing control over the bandwidth of devices formed from the structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Suppressing Thermal Energy Drift In The LLNL Flash X-Ray Accelerator Using Linear Disk Resistor Stacks

This paper addresses thermal drift in sodium thiosulfate liquid resistors and their replacement with linear disk resistors from HVR Advanced Power Components. Sodium thiosulfate resistors in the FXR induction linear accelerator application have a temperature coefficient of {approx}1.8%/C. The FXR Marx banks send an 8kJ pulse through eight 524 cm{sup 3} liquid resistors at a repetition rate of up to 1 every 45 seconds. Every pulse increases the temperature of the solution by {approx}0.4 C which produces a 0.7% change in resistance. The typical cooling rate is {approx}0.4 C per minute which results in {approx}0.1% energy drop per pulse during continuous pulsed operations. A radiographic accelerator is extraordinarily sensitive to energy variations. Changes in beam energy produce movement in beam transport, changes in spot size, and large dose variations. If self-heating were the only problem, we could predict the increase in input voltage required to compensate for the energy loss. However, there are other variables that influence the temperature of the resistors such as focus magnet heating, changes in room temperature, changes in cooling water, where the cell is located, etc. Additionally not all of the resistors have equivalent cooling rates and as many as 32 resistors are driven from a single power source. The FXR accelerator group elected to replace the sodium thiosulfate resistors with HVR Linear Disk Resistors in a stack type configuration. With data limited for these resistors when used in oil and at low resistance values, a full characterization needed to be performed. High currents (up to 15kA), high voltages (up to 400kV), and Fast Rise times (<10ns) made a resistor choice difficult. Other solid resistors have been tried and had problems at the connection points and with the fact that the resistivity changed as they absorbed oil. The selected HVR resistors have the advantage of being manufactured with the oil impregnated in to them so this characteristic is minimized while still offering the desired low temperature coefficient of resistance compared to sodium thiosulfate. The characterization experiments and comparison with the sodium thiosulfate liquid resistors will be fully discussed and the final design described.

42 ENGINEERING↗

Third-Party Aggregation Rulemaking in MISO and SPP Footprints

The report highlights key considerations for retail regulators in the footprints of the Southwest Power Pool (SPP) or Midcontinent Independent System Operator (MISO) in states that previously opted out of allowing third-party aggregation participation under FERC Order 719 and that may want to explore reversing the decision due to a changing policy environment under new FERC orders (i.e., 2222) and/or tightening resource adequacy constraints. Through a document review and a series of 27 interviews with regulators, aggregators, and other industry professionals, this document provides a high-level policy overview of the retail regulator’s role in a selection of processes, rules, and regulations to better understand how states have treated and/or integrated aggregators into wholesale markets. The report summarizes findings in two sections: General Findings and Specific Policy Findings. The General Findings offer high level takeaways such as the fact that 17 of the 20 states in MISO and SPP footprints opted out of third party aggregations following Order 719. Additionally, there is only one state that is fully restructured in the MISO and SPP footprints whereas the rest are vertically integrated, and the majority of third-party aggregations in the U.S. take place in restructured states outside of these footprints. Even so, third-party aggregations do take place in MISO and SPP albeit in small numbers and in an ad hoc regulatory environment. The specific policy findings delve deeper into specific examples of state actions on the topics of jurisdiction, registration and licensing, data governance, dual participation, and dispute resolution. Tables in each category organize state actions into Tiers I-III, which roughly correspond to the possible level of involvement or possible change necessary by state regulators and/or legislators to implement these actions. The tier level does not indicate any value judgement, as each state has respective regulatory limitations and each decision comes with various tradeoffs. One main tradeoff is between simplicity and quick implementation versus comprehensive and prolonged implementation. In many cases, actions in Tier I could be implemented without significant changes by relying on the use of existing processes for an aggregator context. On the other hand, many actions in Tier III are more narrowly designed to address aggregators specifically, but often require more significant changes including the involvement of additional parties through stakeholder engagement or legislative action. In some cases, these tiers are discrete. However, state regulators may also choose to progress through these various tiers sequentially as they phase in aggregators while learning from their experience. With the ability to stack bulk system level services, distributed energy resource aggregations in MISO and SPP could provide various private benefits (e.g., increased value streams to the owner) as well as societally beneficial grid services (e.g., peaking capacity, ancillary services, and other services that increase the grid’s overall operational efficiency). In deciding how to best to enable these benefits, states and retail regulators must weigh various tradeoffs if considering reversing a previous opt out.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Stacked reverberation mapping of high-redshift quasars in DESI. I. Feasibility analysis

The broad-line region of quasars has long been probed by reverberation mapping techniques that measure time lags between continuum and broad emission-line variations. Stacked reverberation mapping has been proposed as a less observationally expensive alternative to traditional methods. This ensemble approach also reduces biases from small-number statistics. The Dark Energy Spectroscopic Instrument (DESI) is conducting the most extensive spectroscopic survey of quasars to date. We create mock light curves emulating expected DESI quasar observations at redshifts $1.48\lt z\lt 5.2$ and luminosities $44.68 \le \log \lambda L_{1350 \mathring{\rm A}{}} / \mathrm{erg\, s^{-1}} \le 45.99$ to test stacked reverberation mapping feasibility using sparse spectroscopic data paired with well-sampled photometric data. The pipeline, using the lag estimation code JAVELIN (Just Another Vehicle for Estimating Lags In Nuclei), successfully recovers the simulated C IV lags within 1σ of the true values using spectroscopic light curves composed of only a few spectral epochs (2–10) with irregular cadences. We investigate how observational factors, including C IV flux error magnitude, number of stacked quasars, and spectral epoch count, affect performance. This work motivates a pathway for future stacked reverberation mapping projects with large-scale spectroscopic surveys of quasars having $\ge 2$ spectroscopic observations. Our results suggest an economical alternative for constraining and extending the radius–luminosity relation to higher redshifts and luminosities. Subsequently, this relation can be employed more reliably in single-epoch black hole mass measurements and quasar cosmology in these distant regimes.

quasars: general, quasars: supermassive black hole↗

Post-irradiation examinations of UO 2 composites as part of the Accident Tolerant Fuels Campaign

Enhanced thermal conductivity uranium dioxide composites containing silicon carbide (UO 2 -SiC) and diamond (UO 2 -diamond) have been irradiated to low burnup. The conditions of this irradiation test and subsequent postirradiation examinations are discussed. These irradiations evaluate fuel microstructure and potential fuel cladding interaction under representative light water reactor power conditions. Both non-destructive and destructive techniques have been used to evaluate fuel integrity, fission gas release, fission product distribution, burnup, fuel swelling and cladding strain. Examination of the UO 2 -SiC pellets revealed enhanced cracking when compared to a UO 2 rodlet also irradiated under similar conditions. Additionally instability of the SiC whiskers in the uranium dioxide matrix was observed in the pellet central region, where the local temperatures exceeded 1300°C. The microstructure of the diamond-added UO 2 was severely disrupted during irradiation, resulting in local migration of cesium along the fuel stack and increased fission gas release when compared with the expected release from the Vitanza curve at corresponding values of burnup and irradiation temperature. The postirradiation examination results cast doubt on the suitability of these additives to improve UO 2 fuel performance in a way that would lead to enhanced accident tolerance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reversible Physical Gelation of Thermotropic Liquid Crystals Driven by Nanoplate Self-Assembly

Physically gelled soft materials, driven by the self-assembly of low-molecular-mass gelators (LMGs), have emerged as a platform for designing advanced gels that exhibit reversible gelation and property tunability. Liquid crystal (LC) gels are of great interest due to their supramolecular orderings as gel hosts and their enhanced electro-optical properties. In this study, we demonstrate the physical gelation of a nematic LC driven by nanoplate self-assembly, expanding the concept of gelators from small molecules to nanoparticles. These nanoplates are functionalized with promesogenic ligands and form a fibrillar network in LCs with face-to-face interplate stacking, resembling LMGs. The critical gelation volume fraction in the tilt test is only 0.14 v %, comparable to values reported for LMGs. Rheological analyses confirm viscoelastic properties characteristic of gelation. In situ small-angle X-ray scattering (SAXS) characterizes the formation of nanoplate networks in the LC with decreasing temperature, wherein LC mesogens become trapped in pores. Molecular dynamics (MD) simulations reveal that the interaction between ligand-coated nanoplates and LC-forming mesogens induces a multidomain LC structure, increasing friction between LC domains and stabilizing the gel. This study establishes direct relationships among molecular interactions, nanostructures, and mechanical properties in physically gelled LCs. In conclusion, the findings inspire the future gelator design of both LMGs and nanoplates, with potential applicability in bioscaffold engineering and liquid crystalline nanocomposites.

36 MATERIALS SCIENCE↗

Lithiation of multilayer Ni/NiO electrodes: criticality of nickel layer thicknesses on conversion reaction kinetics

X-ray reflectivity and transmission electron microscopy (TEM) were used to characterize the morphological changes in thin film electrodes with alternating Ni and NiO layers during lithiation as a function of the Ni buffer layer thickness. Complete lithiation of the active NiO layers occurs only when the thickness of the Ni/NiO bilayers are less than 75 Å – a threshold value that is determined by the sum of the Ni quantity in the Ni/NiO bilayer of the multilayer stack. Thicker Ni/NiO bilayers present a kinetic barrier for lithium ion diffusion inside the stack resulting in partial lithiation of the multilayer electrodes in which only the top NiO layer lithiates. Lithiation of NiO layers in a multilayer stack also leads to an interface-specific reaction that is observed to increase the thicknesses of adjacent Ni layers by 3–4 Å and is associated with the formation of a low-density Li 2 O layer, corresponding to an interfacially-driven phase separation of the NiO. Rate dependent cyclic voltammetry studies reveal a linear relation between the peak current and scan rate suggesting that the lithiation kinetics are controlled by charge transfer resistance at the liquid–solid interface.

25 ENERGY STORAGE↗

SU-E-T-91: Correction Method to Determine Surface Dose for OSL Detectors

Purpose: OSL detectors are commonly used in clinic due to their numerous advantages, such as linear response, negligible energy, angle and temperature dependence in clinical range, for verification of the doses beyond the dmax. Although, due to the bulky shielding envelope, this type of detectors fails to measure skin dose, which is an important assessment of patient ability to finish the treatment on time and possibility of acute side effects. This study aims to optimize the methodology of determination of skin dose for conventional accelerators and a flattening filter free Tomotherapy. Methods: Measurements were done for x-ray beams: 6 MV (Varian Clinac 2300, 10×10 cm{sup 2} open field, SSD = 100 cm) and for 5.5 MV (Tomotherapy, 15×40 cm{sup 2} field, SAD = 85 cm). The detectors were placed at the surface of the solid water phantom and at the reference depth (dref=1.7cm (Varian 2300), dref =1.0 cm (Tomotherapy)). The measurements for OSLs were related to the externally exposed OSLs measurements, and further were corrected to surface dose using an extrapolation method indexed to the baseline Attix ion chamber measurements. A consistent use of the extrapolation method involved: 1) irradiation of three OSLs stacked on top of each other on the surface of the phantom; 2) measurement of the relative dose value for each layer; and, 3) extrapolation of these values to zero thickness. Results: OSL measurements showed an overestimation of surface doses by the factor 2.31 for Varian 2300 and 2.65 for Tomotherapy. The relationships: SD{sup 2300} = 0.68 × M{sup 2300}-12.7 and SDτoμo = 0.73 × Mτoμo-13.1 were found to correct the single OSL measurements to surface doses in agreement with Attix measurements to within 0.1% for both machines. Conclusion: This work provides simple empirical relationships for surface dose measurements using single OSL detectors.

60 APPLIED LIFE SCIENCES↗

SU-E-T-96: Demonstration of a Consistent Method for Correcting Surface Dose Measurements Using Both Solid State and Ionization Chamber Detectors

Purpose: To compare the surface dose (SD) measured using a PTW 30-360 extrapolation chamber with different commonly used dosimeters (Ds): parallel plate ion chambers (ICs): RMI-449 (Attix), Capintec PS-033, PTW 30-329 (Markus) and Memorial; TLD chips (cTLD), TLD powder (pTLD), optically stimulated (OSLs), radiochromic (EXR2) and radiographic (EDR2) films, and to provide an intercomparison correction to Ds for each of them. Methods: Investigations were performed for a 6 MV x-ray beam (Varian Clinac 2300, 10x10 cm{sup 2} open field, SSD = 100 cm). The Ds were placed at the surface of the solid water phantom and at the reference depth dref=1.7cm. The measurements for cTLD, OSLs, EDR2 and EXR2 were corrected to SD using an extrapolation method (EM) indexed to the baseline PTW 30-360 measurements. A consistent use of the EM involved: 1) irradiation of three Ds stacked on top of each other on the surface of the phantom; 2) measurement of the relative dose value for each layer; and, 3) extrapolation of these values to zero thickness. An additional measurement was performed with externally exposed OSLs (eOSLs), that were rotated out of their protective housing. Results: All single Ds measurements overestimated the SD compared with the extrapolation chamber, except for Attix IC. The closest match to the true SD was measured with the Attix IC (− 0.1%), followed by pTLD (0.5%), Capintec (4.5%), Memorial (7.3%), Markus (10%), cTLD (11.8%), eOSL (12.8%), EXR2 (14%), EDR2 (14.8%) and OSL (26%). The EM method of correction for SD worked well for all Ds, except the unexposed OSLs. Conclusion: This EM cross calibration of solid state detectors with an extrapolation or Attix chamber can provide thickness corrections for cTLD, eOSLs, EXR2, and EDR2. Standard packaged OSLs were not found to be simply corrected.

60 APPLIED LIFE SCIENCES↗

Postirradiation Examination of the ATF-1 Experiments - 2018 Status

The Advanced Fuels Campaign in collaboration with industry are working to develop enhanced accident tolerant fuels for light water reactors. The initial irradiations of these concepts were performed in the Idaho National Laboratory Advanced Test Reactor using simple drop-in style irradiations. These irradiations are collectively referred to as ATF 1. The postirradiation examination of ATF 1 has begun and some concepts have now completed initial examination. This report describes the results of examinations on ATF 1 irradiations designed to test the feasibility of enhancing UO 2 thermal conductivity with additives, ATF 1 irradiations of uranium silicide, and the current status of ATF 1 irradiations that are in process at the hot cell. Enhanced thermal conductivity uranium dioxide composites containing silicon carbide (UO 2 SiC) and diamond (UO 2 diamond) have been irradiated to low burnup. The conditions of this irradiation test and subsequent postirradiation examinations are discussed. These irradiations evaluate fuel microstructure and potential fuel cladding interaction under representative light water reactor power conditions. Both non destructive and destructive techniques have been used to evaluate fuel integrity, fission gas release, fission product distribution, burnup, fuel swelling and cladding strain. Examination of the UO 2 SiC pellets revealed enhanced cracking when compared to a UO 2 rodlet also irradiated under similar conditions. Additionally, instability of the SiC whiskers in the uranium dioxide matrix was observed in the pellet central region, where the local temperatures exceeded 1300 °C. The microstructure of the diamond added UO 2 was severely disrupted during irradiation, resulting in local migration of cesium along the fuel stack and increased fission gas release when compared with the expected release from the Vitanza curve at corresponding values of burnup and irradiation temperature. The postirradiation examination results cast doubt on the suitability of these additives to improve UO 2 fuel performance in a way that would lead to enhanced accident tolerance. Additionally, postirradiation examination data of U 3 Si 2 fuels at low burnup (i.e., < 20 GWd/tHM) for application in advanced Light Water Reactor (LWR) is presented. The U 3 Si 2 pellets show limited cracking in comparison to the expected behavior of UO 2 at same power level. In addition, gamma scanning data did not reveal migration of fission products. Minor homogeneous hardening along the pellet radius due to accumulation of fission products and radiation damage was measured by microindentation. The fission gas release and swelling remains very low. Formation of fission gas bubbles resolvable with optical microscopy occurs from the pellets center outward to approximately 60% of the fuel pellet radius. The overall data suggest a good performance of this accident tolerant fuel candidate at low burnup. Finally, the current status of postirradiation examination on other ATF 1 irradiations will be discussed. These irradiations include UO 2 clad in an FeCrAl alloy, an alternative uranium silicide compound U 3 Si 5 also clad in a FeCrAl alloy, and an interaction test between UO 2 and different FeCrAl alloys.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Systematic Study of the Effect of La2O3 Incorporation on the Flatband Voltage and Si Band Bending in the TiN/HfO2 /SiO2 /p-Si Stack

Recent studies have shown that La{sub 2}O{sub 3} films can be used to adjust the threshold voltage (V{sub t}) of NMOS Hf-based high-k/metal gate devices to desirable values, and a dipole at the high-k/SiO{sub 2} interface has been proposed to explain the V{sub t} shifts. In order to investigate the mechanism of the V{sub t} shift further, we have measured the flatband voltage (V{sub fb}) and Si band bending of technologically relevant TiN/HfO{sub 2}/La{sub 2}O{sub 3}/SiO{sub 2}/p-Si stacks where the thickness and position of the La{sub 2}O{sub 3} layer have been systematically varied. We observed systematic changes in V{sub fb}, Si band bending and the HfO{sub 2}-Si valence band offset as a function of La{sub 2}O{sub 3} layer thickness and position. These changes can be explained by a band alignment model that includes a dipole at the high-k/SiO{sub 2} interface, thus supporting the work of previous authors. In addition, we have derived the theoretical relationship between V{sub fb} and Si band bending, which agrees well with our experimental measurements.

36 MATERIALS SCIENCE↗

Vertical Ionization Potentials of Nucleobases in a Fully Solvated DNA Environment

Calculations of the direct ionization potentials (DIP) of DNA nucleobases in the fully solvated DNA helix are reported. The results show an unexpected large shift of roughly 3.2-3.3 eV compared to the corresponding gas-phase IP values. The DIP shift is nearly the same for all the four DNA bases and appears to vary slowly with the stacking and H-bonding interactions of the nucleobases. We demonstrate that the large shift in the DIP of bases is due to the electric potential around the DNA resulting from the long range solvent structure created by the negative phosphate groups and positive counterions of the DNA helical structure. Thermal fluctuations in the fluid can result in DIP changes of roughly 1ev on a picosecond time scale. The model used in this work is based on a QM/MM approach in which the base (or clusters of bases) are chosen as the QM system and calculated using a high-level quantum chemistry method. The remaining DNA fragment and the species in solution are included in an exact molecular mechanics (MM) model. The expected high accuracy of the QM/MM model is defended in terms of the essentially Columbic nature of the interactions of the solvent (the MM region) with isolated base in the quantum region. For the test anion, Cl-, the QM/MM approach yields the 3.4 eV (gas-phase) to 9.3 eV (aqueous solution) shift of the ionization energy in agreement with experimental values (3.6 and 9.6 eV). The localization of the electronic excitation inside the QM region is supported by current experimental and theoretical evidence indicating that the HOMO of the nucleotide is localized on the base rather than the sugar or the phosphate backbone. Our calculations performed in the native DNA environment support this localization. The QM/MM model presented in this work provides an important simplification to the difficult problem of incorporating a detailed structural model of the physiological conditions into investigations of the electronic processes in DNA.

59 BASIC BIOLOGICAL SCIENCES↗

Meta-Study of Particulate Detection Losses on Radioactive Air Sample Filters

Several mathematical relationships between air sample filter mass loading and the correlated analytical self-absorption factor were developed using data from other published research in this meta-study. Gross-alpha and -beta applications are addressed for this research. As filter media becomes loaded with particulate matter, there is potential for measurement losses due to self-absorption by mass loading. Components contributing to absorption include particulate dust, radioactive particulates, and filter material. Standards indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the detection rate by more than 5%. Previously, losses due to self-absorption have been reported up to 100% over a range up to ~10 mg∙cm -2 mass loading. These absorption losses then can be used to determine a correction factor for sample results. For low mass loadings (e.g., ≤0.1 mg∙cm -2 ) corrections factors in the 0.85 - 1 range have been recommended and used, while at higher mass loadings nearer to 10 mg∙cm -2 correction factors closer to 0 (representing near 100% losses) are used. Based on data from published studies, the different methods for relating percent loss due to self-absorption to mass loading include linear, exponential, quadratic, and trinomial derived functions. Where applicable, both forced zero and non-forced zero results were evaluated. From the derived functions evaluated, the trinomial function provided the best fit. Once the sample filter mass loading is known, the trinomial function can be applied to estimate losses and the corresponding self-absorption factor. When applied to routine operating conditions for radiological facility stacks monitored at the Pacific Northwest National Laboratory for an average sample filter mass loading of 0.09 ± 0.12 (2σ) mg∙cm -2 (excluding negative values and outliers) and a range from 0 - 0.24 mg∙cm -2 , the estimated trinomial function nominal self-absorption losses are less than 5% at 0.09 mg∙cm -2 and less than 10% at 0.24 mg∙cm -2 . The trinomial function is one method that may be used to adjust the activity results of an air sample when the sample-specific mass loading is determined. The application of no correction factor when the ANSI/HPS N13.1-2021 guidance of a 5% threshold for loss is not reached with typical stack sample mass loadings may be reasonable in high-efficiency particulate air filtered systems. For simplicity, it would be conservative in assigning the self-absorption correction factor at the 5% threshold (i.e., 0.95) for general uses but in cases of heavy mass loading to calculate the factor.

air sampling↗