Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “uncertainty relation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Relating different quantum generalizations of the conditional Rényi entropy

Recently a new quantum generalization of the Rényi divergence and the corresponding conditional Rényi entropies was proposed. Here, we report on a surprising relation between conditional Rényi entropies based on this new generalization and conditional Rényi entropies based on the quantum relative Rényi entropy that was used in previous literature. Our result generalizes the well-known duality relation H(A|B) + H(A|C) = 0 of the conditional von Neumann entropy for tripartite pure states to Rényi entropies of two different kinds. As a direct application, we prove a collection of inequalities that relate different conditional Rényi entropies and derive a new entropic uncertainty relation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Uncertainty analysis of steady-state measurements with a hot-filament type calorimetric emissometer

Calorimetric emissometers measure total hemispherical emissivity by measuring the heat transferred from a heated sample to its surroundings under a vacuum. The accuracy of emissometers standardized by the ASTM C835-06 are well understood. This work uses the Guide to the Evaluation of Uncertainty in Measurement (GUM) for the propagation uncertainties for an ASTM compliant emissometer. The GUM method was able to develop a measurement model and expressions to determine the uncertainty for other emissometers of this type. Data on ‘as-received’ Hastelloy X was used to develop a detailed uncertainty analysis of the emissivity measurement. Data on ‘as-received’ SS 347 and sandblasted A387 Gr. 91 and previous data by the group on A508/A533B were used to determine uncertainty over the ranges 0.16 to 0.81. For all samples, relative uncertainties in emissivities varied from 0.77% to 2.5% when using a fluxgate magnetometer sensor (FMS) to measure the DC heating current. Data on Hastelloy X using a Hall-effect sensor for DC current and low alloy steel showed the DC current and voltage across the test section to be dominate sources of uncertainty. When these sources were reduced, the specimen temperature and the surface area of the test sections were main sources of uncertainty in the emissivity, especially at higher temperatures. As thermal expansion of the surface was considered in the calculations, correlation between specimen temperature and surface area was examined. It was found to be a small contribution to emissivity's uncertainty despite the differences in linear CTE and its uncertainty for the materials analyzed in this study. For low temperatures, the chamber temperature can be a significant source of uncertainty if not sufficiently cooled. The GUM was also briefly compared to uncertainty from the 2nd and 3rd expansions of the Taylor series. We found that the results were the same when rounding to two significant figures.

42 ENGINEERING↗

In search of the perfect fluid

Shear viscosity measures the amount of internal friction in a simple fluid. In kinetic theory shear viscosity is related to momentum transport by quasi-particles, and the uncertainty relation implies that the ratio of shear viscosity {eta} to entropy density s is bounded by a constant multiplied by h/k{sub B}, where h is Planck's constant and k{sub B} is Boltzmann's constant. A specific bound has been proposed on the basis of string theory. In a large class of theories that can be studied using string theory methods the constant is 1/(4{pi}). Experiments at RHIC indicate that {eta}/s of the quark gluon plasma is close to this prediction. We will refer to a fluid that saturates the string theory bound as a perfect fluid. In this contribution we summarizes the theoretical and experimental information on the fluidity of the main classes of strongly interacting quantum fluids.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of the uncertainties in velocity measurements with triple hot-wire probes

A detailed computerized sensitivity analysis of the triple hot-wire equations has been performed in order to delineate the uncertainties associated with measurements of the velocity components. Absolute and relative uncertainties for the instantaneous hot-wire outputs are calculated as functions of roll and pitch angles, based on a constant probability combination of the uncertainties in the inputs. From the results, it is concluded that the small inherent difficulties associated with the triple hot-wire data do not reflect artifacts introduced by the data processing. Fixed errors present in the V and W channels of the output are due to the nonzero measuring volume of the triple wire probe, and are entirely predictable.

Frota, M. N.↗

Effects of Photovoltaic Module Materials and Design on Module Deformation Under Load

Static structural finite element models of an aluminum-framed crystalline silicon (c-Si) photovoltaic (PV) module and a glass-glass thin film PV module were constructed and validated against experimental measurements of deflection under uniform pressure loading. Parametric analyses using Latin Hypercube Sampling (LHS) were performed to propagate simulation input uncertainties related to module material properties, dimensions, and manufacturing tolerances into expected uncertainties in simulated deflection predictions. This exercise verifies the applicability and validity of finite element modeling for predicting mechanical behavior of solar modules across architectures and enables computational models to be used with greater confidence in assessment of module mechanical stressors and design for reliability. Sensitivity analyses were also performed on the uncertainty quantification data sets using linear correlation coefficients to elucidate the key parameters influencing module deformation. This information has implications on which materials or parameters may be optimized to best increase module stiffness and reliability, whether the key optimization parameters change with module architecture or loading magnitudes, and whether parameters such as frame design and racking must be replicated in reduced-scale reliability studies to adequately capture full module mechanical behavior.

14 SOLAR ENERGY↗

A preliminary study of the variability and magnitude of the flux of biogenic sulfur gases from a New Hampshire salt marsh

Salt marshes have highly variable spatial and temporal fluxes of hydrogen sulfide, carbonyl sulfide, methane thiol, dimethyl sulfide, and carbon disulfide (H2S, COS, MeSH, DMS, and CS2, respectively). This variability was tested at nine emission sites in a New Hampshire, USA salt marsh: three replicates in each of three vegetation zones, Spartina alterniflora, S. patens, and a transition zone. Three sites were sampled simultaneously, either within or across vegetation zones, using a dynamic flux chamber technique. Difficulties with calibration and field equipment resulted in fluxes with maximum absolute uncertainties of greater than plus or minus 200 percent. However, the relative uncertainty between subsequent samples was closer to plus or minus 20 percent. Chambers are expected to affect the natural flux of gases by altering the humidity, temperature, and composition of the gas inside the chamber. Summertime fluxes are highest for all gases except COS which demonstrated evidence of a springtime peak. A summertime background flux of 5 to 100 x 10(exp -9) g S/m(sup -2) min was observed for all gases, while S alternifora fluxes of MeSH and DMS were approximately 8 fold and approximately 100 fold higher than S. patens, respectively. DMS and MeSH fluxes were higher during the day than at night. Evidence of COS uptake by plants was observed. CS2 appeared to be the quantitatively least important sulfur gas emitted. Improved laboratory and sample collection techniques and further data collection in the field will yield information on the details of salt marsh variability, will improve estimates of the error associated with single flux measurements, and will allow a more accurate estimation of sulfur fluxes from salt marshes based on vegetation and area coverage data. Inability to control the temperature and humidity inside of the chamber remain significant problems with the chamber design.

Morrison, Michael Cope↗

Performance of Trajectory Models with Wind Uncertainty

Typical aircraft trajectory predictors use wind forecasts but do not account for the forecast uncertainty. A method for generating estimates of wind prediction uncertainty is described and its effect on aircraft trajectory prediction uncertainty is investigated. The procedure for estimating the wind prediction uncertainty relies uses a time-lagged ensemble of weather model forecasts from the hourly updated Rapid Update Cycle (RUC) weather prediction system. Forecast uncertainty is estimated using measures of the spread amongst various RUC time-lagged ensemble forecasts. This proof of concept study illustrates the estimated uncertainty and the actual wind errors, and documents the validity of the assumed ensemble-forecast accuracy relationship. Aircraft trajectory predictions are made using RUC winds with provision for the estimated uncertainty. Results for a set of simulated flights indicate this simple approach effectively translates the wind uncertainty estimate into an aircraft trajectory uncertainty. A key strength of the method is the ability to relate uncertainty to specific weather phenomena (contained in the various ensemble members) allowing identification of regional variations in uncertainty.

Lee, Alan G.↗

Criticality Safety S/U based USL Calculation for UCl3-NaCl Fuel Salt Operations

Recent experimental data has shown inconsistencies with the 35Cl(n,p) cross-section. The cross-section uncertainty data does not account for the recent data. The 1s relative uncertainty is assumed to be 100% for the 35Cl(n,p) cross section over all energies above 0.017 MeV TerraPower and LANL have recently done cross-section measurements and developed new cross-sections for 35Cl.

99 - GENERAL AND MISCELLANEOUS↗

Uncertainties in derived temperature-height soundings A summary

It is shown that high-resolution low-uncertainty temperature-height profiles cannot be deduced from pressure-height data alone because the relative uncertainty in pressure data cannot be expected to be smaller than 1% or 2% in present-day practical instrumentation. The basic equations relating temperature to pressure-height or density-height data are subjected to error analysis to determine the uncertainty introduced into computed temperature-height values by observed data. The results show that the use of density data is much more preferable than the use of pressure data if atmospheric temperature is to be determined as a function of height with a fine height resolution and a small uncertainty from the height profiles of pressure or density and if pressures and densities can be measured with comparable accuracies.

Minzner, R. A.↗

Orbit determination for the Voyager II Uranus encounter

The Voyager II flyby of Uranus in January 1986 was the most distant planetary encounter ever attempted, and presented unique challenges to the process of orbit determination. Long light-times and spacecraft receiver difficulties hampered the collection of two-way radiometric data and helped bring about the maturation of a Very Long Baseline Interferometry navigational data type during the long cruise from Saturn. Planet and satellite ephemeris uncertainties necessitated the use of the onboard spacecraft optical system for Uranus-relative navigation. During the close approach phase, these optical data were combined with radiometric data to drive the Uranus system-relative uncertainties down to the level of a few tens of kilometers. This paper contains qualitative and quantitative results and conclusions based on orbit determination experience during Uranus cruise and encounter. Topics include an overview of the navigation-related mission events and requirements, and a review of the salient orbit determination results.

Taylor, T. H.↗

Power system resilience through defender-attacker-defender models with uncertainty: an overview

Protecting and fortifying a power system to make it resilient is an important and hard problem to solve. The interaction between defenders and attackers, the availability of information and the complexity of power system require carefully selecting models and presenting the underlying assumptions. Trilevel defender-attacker-defender models have been developed to investigate the resilience of power systems. In this paper, we review trilevel models in power system application, with the aim of demonstrating the accessibility and applicability of these complex optimization formulations and discussing the underlying assumptions from these models. In particular, we highlight modeling choices, algorithmic details, and how operational and information uncertainty affects resilience versus the traditional complete-knowledge-based optimal solutions. We also describe other similar relevant models which lack such uncertainty and discuss insights on how to address operational, attacker, and defender related uncertainties in future research efforts.

multi-level optimization, defender-attacker-defend↗

What is the Uncertainty in MODIS Aerosol Optical Depth in the Vicinity of Clouds?

MODIS dark-target (DT) algorithm retrieves aerosol optical depth (AOD) using a Look Up Table (LUT) approach. Global comparison of AOD (Collection 6 ) with ground-based sun photometer gives an Estimated Error (EE) of +/-(0.04 + 10%) over ocean. However, EE does not represent per-retrieval uncertainty. For retrievals that are biased high compared to AERONET, here we aim to closely examine the contribution of biases due to presence of clouds and per-pixel retrieval uncertainty. We have characterized AOD uncertainty at 550 nm, due to standard deviation of reflectance in 10 km retrieval region, uncertainty related to gas (H2O, O3) absorption, surface albedo, and aerosol models. The uncertainty in retrieved AOD seems to lie within the estimated over ocean error envelope of +/-(0.03+10%). Regions between broken clouds tend to have higher uncertainty. Compared to C6 AOD, a retrieval omitting observations in the vicinity of clouds (< or = 1 km) is biased by about +/- 0.05. For homogeneous aerosol distribution, clear sky retrievals show near zero bias. Close look at per-pixel reflectance histograms suggests retrieval possibility using median reflectance values.

Patadia, Falguni↗

Convolution-based frequency domain multiplexing of SiPM readouts using the $\mathrm{DRS4}$ digitizer

Here we present 4:1 multiplexing of organic scintillators, each coupled to a silicon photomultiplier (SiPM), to reduce the need for a large number of digitizer input channels to readout highly pixelated radiation detection systems. Frequency domain multiplexing (FDM) encodes a detector pulse by assigning it a unique frequency via convolution before combining the encoded signal into a single channel. The combined signal is then read through a digitizer input channel. We have designed an FDM system to multiplex four SiPMs using DRS4 digitizer evaluation board from Paul Scherrer Institute (PSI). We demonstrate 4:1 multiplexing of the SiPM fast output signals and pulse recovery from the digitized multiplexed signal using deconvolution. The noise in the recovered pulse introduces a bias and uncertainty in the estimate of energy and timing that changes with pulse height. The relative uncertainty in the estimated energy from the recovered pulse decreases with pulse height with a maximum uncertainty of 3.1% for the low energy pulses (corresponding to 100 keV); the uncertainty in the estimated time pick-off also decreases with pulse height with a maximum uncertainty of 110 ps for the low energy pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Weak values and weak coupling maximizing the output of weak measurements

In a weak measurement, the average output 〈o〉 of a probe that measures an observable A{sup -hat} of a quantum system undergoing both a preparation in a state ρ{sub i} and a postselection in a state E{sub f} is, to a good approximation, a function of the weak value A{sub w}=Tr[E{sub f}A{sup -hat} ρ{sub i}]/Tr[E{sub f}ρ{sub i}], a complex number. For a fixed coupling λ, when the overlap Tr[E{sub f}ρ{sub i}] is very small, A{sub w} diverges, but 〈o〉 stays finite, often tending to zero for symmetry reasons. This paper answers the questions: what is the weak value that maximizes the output for a fixed coupling? What is the coupling that maximizes the output for a fixed weak value? We derive equations for the optimal values of A{sub w} and λ, and provide the solutions. The results are independent of the dimensionality of the system, and they apply to a probe having a Hilbert space of arbitrary dimension. Using the Schrödinger–Robertson uncertainty relation, we demonstrate that, in an important case, the amplification 〈o〉 cannot exceed the initial uncertainty σ{sub o} in the observable o{sup -hat}, we provide an upper limit for the more general case, and a strategy to obtain 〈o〉≫σ{sub o}. - Highlights: •We have provided a general framework to find the extremal values of a weak measurement. •We have derived the location of the extremal values in terms of preparation and postselection. •We have devised a maximization strategy going beyond the limit of the Schrödinger–Robertson relation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Saturation of fluorescence in flames with a Gaussian laser beam

The method of saturated fluorescence for measuring species concentrations in flames is usually performed with laser beams that do not provide a constant intensity distribution across the focal volume. Because of the intensity distribution across the beam, the fluorescence signal does not depend on laser power or intensity in the same manner as for uniform illumination. This leads to anomolous apparent saturation intensities. In the following, the effect is considered for atomic fluorescence. Relations for the fluorescence signal under two common excitation geometries are derived and uncertainty relations used to consider the benefits of high laser intensity.

Daily, J. W.↗

Analysis of Nitrogen Shockwave Radiation at Velocity Around 7km/s

In the last decade, the Electric Arc Shock Tube (EAST) facility has been widely used to provide experimental data aiming to validate radiative heating models used for atmospheric entry, mostly at velocities above 9km/s in air. In more recent years, another experimental campaign aimed to look at velocity below 9 km/s and its analysis resulted in a significant improvement of the air kinetic model using new rates found in the literature but discrepancies were still observed, especially for the N2 second positive system. Despite these previous studies, the overall uncertainties related to surface heating for lunar return remain around 50% To reduce these uncertainties, the last experimental campaign at EAST, named test 62, was conducted in pure nitrogen at velocity ranging from 6 to 11 km/s at a freestream pressure of 0.2 Torr to provide more fundamental data on nitrogen. A previous study analyzed the data obtained at a velocity of 10.3 km/s, where atomic radiation is dominant, and provided spatially resolved density measurements of different states of nitrogen. This study will focus on experimental data obtained at shock velocity of 6.88 and 7.15 km/s where molecular nitrogen is expected to be the dominant source of radiation.

Augustin Tibere-Inglesse↗

Improving nuclear power plant safety and operating margins through linear quadratic estimation - 290

Redundant measurement, trip, and actuation channels are required for reactor trips and engineered safety systems in nuclear power plants. There are three or four independent channels in existing plants, depending on the system. To prevent failures, consistent signals from any two channels together can trip the reactor or actuate safety systems. Measurements associated with safety trips and actuations include uncertainties related to the instruments making the measurements and to process conditions. Margins that include measurement uncertainties are set for each trip and actuation channel as though it were the only one taking action, thus preserving independence. There are sensors, however, that provide partially redundant information that could be used to decrease the uncertainty associated with measurements of plant conditions, while maintaining the three-channel redundancy important to plant safety. Reducing these uncertainties would both improve plant safety by providing more accurate knowledge of plant conditions and improve the operating margins that must take such uncertainties into account. This paper demonstrates how information that is already available to plant instrumentation and control systems and is already redundant can be used through software routines to reduce the error that must be taken into account in reactor trip and safety system actuation setpoints. Issues that would have to be addressed related to standards, licensing, and implementation are also discussed. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

WE-D-BRE-07: Variance-Based Sensitivity Analysis to Quantify the Impact of Biological Uncertainties in Particle Therapy

Purpose: In particle therapy, treatment planning and evaluation are frequently based on biological models to estimate the relative biological effectiveness (RBE) or the equivalent dose in 2 Gy fractions (EQD2). In the context of the linear-quadratic model, these quantities depend on biological parameters (α, β) for ions as well as for the reference radiation and on the dose per fraction. The needed biological parameters as well as their dependency on ion species and ion energy typically are subject to large (relative) uncertainties of up to 20–40% or even more. Therefore it is necessary to estimate the resulting uncertainties in e.g. RBE or EQD2 caused by the uncertainties of the relevant input parameters. Methods: We use a variance-based sensitivity analysis (SA) approach, in which uncertainties in input parameters are modeled by random number distributions. The evaluated function is executed 10{sup 4} to 10{sup 6} times, each run with a different set of input parameters, randomly varied according to their assigned distribution. The sensitivity S is a variance-based ranking (from S = 0, no impact, to S = 1, only influential part) of the impact of input uncertainties. The SA approach is implemented for carbon ion treatment plans on 3D patient data, providing information about variations (and their origin) in RBE and EQD2. Results: The quantification enables 3D sensitivity maps, showing dependencies of RBE and EQD2 on different input uncertainties. The high number of runs allows displaying the interplay between different input uncertainties. The SA identifies input parameter combinations which result in extreme deviations of the result and the input parameter for which an uncertainty reduction is the most rewarding. Conclusion: The presented variance-based SA provides advantageous properties in terms of visualization and quantification of (biological) uncertainties and their impact. The method is very flexible, model independent, and enables a broad assessment of uncertainties. Supported by DFG grant WI 3745/1-1 and DFG cluster of excellence: Munich-Centre for Advanced Photonics.

60 APPLIED LIFE SCIENCES↗