Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “unbalanced system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The Behavior of PCM/PM Receivers in Non-Ideal Channels

This paper presents a performance evaluation of residual carrier commuication systems that employ a PCM/PM modulation technique operating over non-ideal channels. The non-ideal channels under investigation include data asymmetry, an unbalanced data stream (i.e., transition density deviates from 0.5) and InterSymbol Interference (ISI).

InterSymbol Interference↗

Model-Free Voltage Control of Active Distribution System with PVs Using Surrogate Model-Based Deep Reinforcement Learning

Accurate knowledge of the distribution system topology and parameters is required to achieve good voltage control performance, but this is difficult to obtain in practice. This paper proposes a physical-model-free voltage control method based on a surrogate-model-enabled deep reinforcement learning approach. Specifically, a surrogate model is trained in a supervised manner using the recorded limited number of historical data to learn the relationship between the power injections and voltage fluctuations of each node. Then, the deep reinforcement learning algorithm is applied to learn an optimal control strategy from the experiences obtained by continuous interactions with the surrogate model. The proposed method can achieve physical-model-free control of unbalanced distribution network and inform real-time decisions to deal with fast voltage fluctuations caused by the rapid variation of PV generation. Simulation results on an unbalance IEEE 123-bus system show that the proposed method can achieve similar performance as that of perfect physical-model-based approaches while being advantageous over other traditional methods.

active distribution network↗

Integrating Transactive Energy into Reliability Evaluation for a Self-healing Distribution System with Microgrid

Non-utility owned distributed energy resources (DERs) are mostly untapped currently, but they can provide many grid services such as voltage regulation and service restoration, if properly controlled, and can improve the distribution systems reliability when coordinated with utility-owned assets such as self-healing control and microgrids. This paper integrates transactive energy control into the distribution system reliability evaluation to quantitatively assess the impact of non-utility owned DERs on reliability improvement. Here, a transactive reactive power control strategy is designed to incentivize the DERs to provide reactive power support for improving voltage profiles thus enabling additional customer load restoration during an outage. Also, an operational sequence to coordinate the non-utility owned DERs with the utility owned self-healing control and utility owned microgrids is designed and integrated into the service restoration process with the operational constraints guaranteed by checking the three-phase unbalanced power flow for post-fault network reconfiguration. The reliability indices are then calculated through a Monte Carlo simulation. The transactive reactive power control strategy is tested on a four-feeder distribution system operated by Duke Energy in the U.S. Results demonstrate that the non-utility owned DERs with the transactive control improve the reliability of both the system and critical loads by more than 30%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Generalized Power Flow Model of an Extra High-Power Multi-Terminal HVdc Transmission Grid with Parallel-Connected and Voltage-Stacked Converters

To increase power transfer capacity of high-voltage direct current (HVdc) transmission, a new extra high-power HVdc architecture with multiple standard modular multilevel converters (MMCs) per substation has recently been introduced. This paper proposes a power flow model for a multi-terminal HVdc (MTdc) grid with this innovative substation architecture. The proposed MTdc model can be integrated seamlessly with existing ac-dc power flow algorithms with minimal modifications. The model is applicable to various MTdc grid types and topologies, different numbers of dc buses, dc lines, and MMCs per substation, along with diverse control parameters. In addition, it accurately captures both balanced and unbalanced operations of the MTdc grid. The proposed model is verified using a 5-terminal bipole MTdc grid that spans 4 areas in the Eastern Interconnection system of the USA. The numerical solutions obtained from unified and sequential ac-dc power flow algorithms under different operating conditions closely match the time-domain simulation results in PSCAD, validating the accuracy and versatility of the proposed MTdc power flow model.

Nguyen, Quan H.↗

Stability and transient motion of a plain journal mounted in flexible damped supports

Results are presented for an extensive study of the influence of damped flexible supports on the stability-threshold speed of a symmetric rotor mounted in nonlinear fluid-film bearings. A stability analysis is conducted by applying the Routh criteria and calculating the damped eigenvalues of the system. Stability maps are given in dimensionless form for a range of support stiffness, damping, and mass ratios. The effect of rotor imbalance on the stability of rotor systems is examined, and it is shown that time transient orbits of shaft and support motions clearly indicate their dynamic behavior for both stable and unstable operating speeds. Simple design criteria are proposed for choosing the support stiffness and damping on the basis of rotor weight and journal clearance to promote optimum stability. It is concluded that the use of a flexible damped support system may increase the stability threshold of a plain journal bearing and that damper supports should promote smoother and quieter machine operation by suppressing oil whirl and attenuating unbalanced rotational forces.

Kirk, R. G.↗

Performance of unbalanced QPSK in the presence of noisy reference and crosstalk

The problem of transmitting two telemetry data streams having different rates and different powers using unbalanced quadriphase shift keying (UQPSK) signaling is considered. It is noted that the presence of a noisy carrier phase reference causes a degradation in detection performance in coherent communications systems and that imperfect carrier synchronization not only attenuates the main demodulated signal voltage in UQPSK but also produces interchannel interference (crosstalk) which degrades the performance still further. Exact analytical expressions for symbol error probability of UQPSK in the presence of noise phase reference are derived.

Divsalar, D.↗

Simultaneous amplification of terahertz difference frequencies by an injection-seeded semiconductor laser amplifier at 850 nm

Two-frequency operation of an 850 nm semiconductor optical amplifier was achieved by simultaneously injection seeding it with two diode lasers. The two frequencies could be independently amplified without strong interference when they were separated by more than 10 GHz, and the spectral purity was preserved by the amplification process. At frequency differences below 10 GHz, unbalanced two-frequency output was observed, which can be explained by a two-mode interaction driven by the refractive index modulation at the beat frequency. The laser system is suitable for the difference-frequency generation of coherent terahertz radiation in ultra-fast photoconductors or nonlinear optical media.

NASA Discipline Exobiology↗

Light-Duty Vehicle Trip Classification Using One-Class Novelty Detection and Exhaustive Feature Extraction

Travel mode classification within travel survey data sets, especially light-duty vehicle (LDV) trips, is foundational, though nontrivial, to emerging mobility systems, travel behavior analysis, and fuel consumption estimation. Current travel mode detection approaches require well-sampled and balanced data sets with ground truth travel mode labels. The detection approaches are rarely applied and validated on large-scale, real-world data sets, which may not satisfy the dataset requirements. This work proposes an LDV trip detection model as a supplement to current travel mode detection methods, for the case when the training set is highly (and/or completely) unbalanced, to the extent that classical machine-learning approaches become difficult or impossible to deploy. The proposed model uses a novelty detection technique - one-class support vector machines (OCSVMs) - and a novel exhaustive feature extraction (EFE) technique on continuous time series data (i.e., Global Positioning System [GPS] speed profiles) for single-mode trip trajectories. Training and validation of the model are conducted on a large-scale, real-world data set. The proposed method accurately identifies LDV trips from a broad set of multimodal trips by leveraging a wealth of preexisting in-vehicle GPS travel data. Additional sensitivity analysis sheds light on the optimal training size and feature selection, which will benefit applications limited by highly imbalanced data. The paper also discusses performance comparison with regular machine-learning approaches, the model's robustness, and the potential to extend the proposed model to multi-modal trip prediction.

33 ADVANCED PROPULSION SYSTEMS↗

Integrated Hydrogen Energy System Testing/Validation: Cooperative Research and Development Final Report, CRADA Number CRD-21-18272

Through the ARIES platform, this proposed project aims to bridge a gap and utilize the power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments and create open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid forming fuel cell inverters.

08 HYDROGEN↗

Fan blade protection system

In one type of aircraft propulsion system, propeller blades are mounted on a ring which surrounds a turbine. An annular space exists between the turbine and the ring. If a propeller blade should break free, the unbalanced centrifugal load tends to deform the ring. The invention reduces the deformation, as by locating spacers between the turbine and the ring.

Hermans, Thomas C.↗

Human Systems Integration (HSI) Framework and Training - Shifting the View of HSI for Better Implementation

The Implementation of Human Systems Integration (HSI) presents challenges within the acquisition community for two reasons. The first is that misconceptions of HSI still exist, with many Program Managers (PMs) and leadership uncertain of the value or where to begin. The second is due to an unbalanced approach to HSI in its own framework. These implementation challenges lead to barriers in the early prevention of mishaps. Understanding HSI practices and how they should be implemented in the Acquisition Product Life Cycle (PLC) has been a challenge across the government, leaving the value of HSI unknown and misunderstood with Program Managers. In the case for many acquisition programs, HSI is not implemented in early design, losing the perspective on human capabilities and limitations, creating impacts on human-centered design. Expectations in human performance are not clearly set and operations are baselined with no margin for changes in technology and processes that will affect system performance. The HSI framework addresses total system performance holistically using collaboration as the primary tool. The goal is to create a system with efficiencies while minimizing risk to the operators, maintainers, and support personnel, as well as any collateral personnel and systems. To accomplish this, HSI should be implemented as part of preemptive measures to minimize potential human error and mishaps during the operation phase. Investigative and assessment tools exist that consider events, issues, and other outside influences of a system that may not fall under the current construct of the HSI domains, leaving gaps in early HSI implementation and affecting the prevention of human errors and mishaps. This presentation will outline what NASA HSI is doing to support Early HSI implementation and Operational Performance shifts that affect human performance.

Anthony T Thomas↗

Rapid QSTS Simulations for High-Resolution Comprehensive Assessment of Distributed PV

The rapid increase in penetration of distributed energy resources on the electric power distribution system has created a need for more comprehensive interconnection modeling and impact analysis. Unlike conventional scenario-based studies, quasi-static time-series (QSTS) simulations can realistically model time-dependent voltage controllers and the diversity of potential impacts that can occur at different times of year. However, to accurately model a distribution system with all its controllable devices, a yearlong simulation at 1-second resolution is often required, which could take conventional computers a computational time of 10 to 120 hours when an actual unbalanced distribution feeder is modeled. This computational burden is a clear limitation to the adoption of QSTS simulations in interconnection studies and for determining optimal control solutions for utility operations. The solutions we developed include accurate and computationally efficient QSTS methods that could be implemented in existing open-source and commercial software used by utilities and the development of methods to create high-resolution proxy data sets. This project demonstrated multiple pathways for speeding up the QSTS computation using new and innovative methods for advanced time-series analysis, faster power flow solvers, parallel processing of power flow solutions and circuit reduction. The target performance level for this project was achieved with year-long high-resolution time series solutions run in less than 5 minutes within an acceptable error.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nonlinear rotordynamics analysis

Effective analysis tools were developed for predicting the nonlinear rotordynamic behavior of the Space Shuttle Main Engine (SSME) turbopumps under steady and transient operating conditions. Using these methods, preliminary parametric studies were conducted on both generic and actual HPOTP (high pressure oxygen turbopump) models. In particular, a novel modified harmonic balance/alternating Fourier transform (HB/AFT) method was developed and used to conduct a preliminary study of the effects of fluid, bearing and seal forces on the unbalanced response of a multi-disk rotor in the presence of bearing clearances. The method makes it possible to determine periodic, sub-, super-synchronous and chaotic responses of a rotor system. The method also yields information about the stability of the obtained response, thus allowing bifurcation analyses. This provides a more effective capability for predicting the response under transient conditions by searching in proximity of resonance peaks. Preliminary results were also obtained for the nonlinear transient response of an actual HPOTP model using an efficient, newly developed numerical method based on convolution integration. Currently, the HB/AFT is being extended for determining the aperiodic response of nonlinear systems. Initial results show the method to be promising.

Noah, Sherif T.↗

2020 International Conference on Smart Grids and Energy Systems (SGES)

This paper is concerned about phasor-based linear state estimation of three-phase power grids which contain non transposed lines and unsymmetrical branches. It builds upon our previous work where the linear measurement equations were decoupled into three independent sets via the symmetrical component transformation. Such a transformation may however not fully decouple the measurement equations if there are nontransposed transmission lines and unsymmetrical branches in the system. This paper addresses this limitation by deriving additive terms that compensate for the remaining coupling between sequence measurements after the application of the conventional transformation. It will be shown that general unbalanced threephase power grids can still be transformed into three decoupled subsystems and their state estimation solution can be obtained in parallel by the proposed approach.

Khalili, Ramtin↗

A Three-Dimensional Variational Data Assimilation Scheme for the Regional Ocean Modeling System: Implementation and Basic Experiments

A three-dimensional variational data assimilation scheme for the Regional Ocean Modeling System (ROMS), named ROMS3DVAR, has been described in the work of Li et al. (2008). In this paper, ROMS3DVAR is applied to the central California coastal region, an area characterized by inhomogeneity and anisotropy, as well as by dynamically unbalanced flows. A method for estimating the model error variances from limited observations is presented, and the construction of the inhomogeneous and anisotropic error correlations based on the Kronecker product is demonstrated. A set of single observation experiments illustrates the inhomogeneous and anisotropic error correlations and weak dynamic constraints used. Results are presented from the assimilation of data gathered during the Autonomous Ocean Sampling Network (AOSN) experiment during August 2003. The results show that ROMS3DVAR is capable of reproducing complex flows associated with upwelling and relaxation, as well as the rapid transitions between them. Some difficulties encountered during the experiment are also discussed.

California coastal ocean↗

Dynamic State Estimation for Radial Microgrid Protection

Dynamic state estimation (DSE) is a generalization of differential protection that offers a reduced likelihood of misoperation, particularly in the case of devices with nonlinear characteristics such as transformers which are being energized. It is also useful in cases where distance protection performs poorly, such as transmission lines with series compensation or mutually coupled transmission lines. DSE has been previously applied to microgrid branch protection. This study investigates the use of DSE for protection of radial portions of a microgrid or distribution system. This can be a challenge in microgrids or distribution systems with distributed generation on account of lack of fault current from inverter-interfaced generation, varying fault current between grid- connected and islanded modes, the potential for normally-meshed operation and unbalanced operation due to single-phase loads. Admittance relaying has been investigated as a solution for protection of microgrids, though it has been observed to have issues with grounded-wye connected loads, and additional relaying is necessary to prevent misoperation.

24 POWER TRANSMISSION AND DISTRIBUTION↗