Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “trough”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Lidar-Based Evaluation of HRRR Performance in California’s Diablo Range

The performance of the NOAA High-Resolution Rapid Refresh (HRRR) model for capturing low-level winds near a wind energy production site during summer 2019 is evaluated. This study catalogs the ability of HRRR to predict boundary layer dynamics relevant to wind energy interests over complex terrain, which has presented challenges for weather and energy forecasting. Performance is evaluated by comparing HRRR output to wind-profiling Doppler lidars at Lawrence Livermore National Laboratory Site 300. HRRR captured the diurnal profile of horizontal winds in the observed 150-m layer, despite strong underpredictions (∼4 m s −1 ) during evening and nighttime hours. These underpredictions may be a result of local speedup flows observed by the lidars, which were unresolved in HRRR due to their small spatial extent. HRRR bias magnitude relative to observations was found to be minimal during days with synoptic-scale troughs and strong 850-hPa geopotential gradients, while bias magnitude was maximal during days with synoptic ridging and weak 850-hPa geopotential gradients. To translate wind speed predictions to energy forecasting, generic turbine models were used to estimate power generation for turbines characteristic of the nearby Altamont Pass Wind Resource Area. Results show that HRRR-based energy estimates predicted daytime power generation adequately relative to lidar-based estimates with an 18-h lead time (bias magnitude < 0.4 MW from 0900 to 1400 LT) but overpredicted power during the rest of the diurnal cycle (bias > 1 MW). These results demonstrate conditions under which HRRR performs well for wind energy applications in complex terrain, while highlighting biases that require further investigation to support usage of a high-resolution model for wind energy forecasts.

Boundary layer↗

Oxygen torus and its coincidence with EMIC wave in the deep inner magnetosphere: Van Allen Probe B and Arase observations

We investigate the longitudinal structure of the oxygen torus in the inner magnetosphere for a specific event found on 12 September 2017, using simultaneous observations from the Van Allen Probe B and Arase satellites. It is found that Probe B observed a clear enhancement in the average plasma mass (M) up to 3–4 amu at L = 3.3–3.6 and magnetic local time (MLT) = 9.0 h. In the afternoon sector at MLT ~ 16.0 h, both Probe B and Arase found no clear enhancements in M. This result suggests that the oxygen torus does not extend over all MLT but is skewed toward the dawn. Since a similar result has been reported for another event of the oxygen torus in a previous study, a crescent-shaped torus or a pinched torus centered around dawn may be a general feature of the O + density enhancement in the inner magnetosphere. We newly find that an electromagnetic ion cyclotron (EMIC) wave in the H + band appeared coincidently with the oxygen torus. From the lower cutoff frequency of the EMIC wave, the ion composition of the oxygen torus is estimated to be 80.6% H + , 3.4% He + , and 16.0% O + . According to the linearized dispersion relation for EMIC waves, both He + and O + ions inhibit EMIC wave growth and the stabilizing effect is stronger for He + than O + . Therefore, when the H + fraction or M is constant, the denser O + ions are naturally accompanied by the more tenuous He + ions, resulting in a weaker stabilizing effect (i.e., larger growth rate). From the Probe B observations, we find that the growth rate becomes larger in the oxygen torus than in the adjacent regions in the plasma trough and the plasmasphere.

79 ASTRONOMY AND ASTROPHYSICS↗

The Imperial Valley Dark Fiber Project: Toward Seismic Studies Using DAS and Telecom Infrastructure for Geothermal Applications

We report that the Imperial Valley is a seismically active basin occupying the southern end of the Salton trough, an area of rapid extension, high heat flow, and abundant geothermal resources. This report describes an ongoing large-scale distributed acoustic sensing (DAS) recording study acquiring high-density seismic data on an array between Calipatria and Imperial, California. This 27 km array, operating on dark fiber since 9 November 2020, has recorded a wealth of local seismic events as well as ambient noise. The goal of the broader Imperial Valley Dark Fiber project is to evaluate passive DAS as a tool for geothermal exploration and monitoring. This report is intended to provide installation information, noise characteristics, and metadata for future studies utilizing the data set. Because of the relatively small number of basin-scale DAS studies that have been conducted to date, we also provide a range of lessons learned during the deployment to assist future researchers exploring this acquisition strategy.

15 GEOTHERMAL ENERGY↗

Renewable Thermal Energy Systems Designed for Industrial Process Solutions in Multiple Industries

The need for renewable heat in industry is vital for the next decade and beyond. Industrial decarbonization is a key area that must be accelerated, to foster the removal of fossil fuels from the provision of heat, especially at low temperatures. This paper looks at the development and results of case studies for understanding the economics and potential for renewable thermal energy systems (RTES), particularly in hybrid configurations to provide industrial process heat (IPH). For the case studies, these include non-concentrating e.g., heat pumps, and concentrating collectors e.g., parabolic trough collectors and direct steam generation (DSG)-linear Fresnel collectors (LFCs). The results show that a levelized cost of heat (LCOH) of $6-$8 per million British Thermal Units (MMBTU) is possible, depending on the direct normal irradiance (DNI) and the system sizing e.g., to increase the solar fractions. In Arizona for example, with a DNI of 7.36 kWh/m2/day, the base case for the DSG-LFC system with 6hrs of thermal energy storage could potentially meet a 1 MWth load 80% of the year.

concentrated solar thermal↗

New Insights from Legacy Seismic Data regarding Basalt Elevations and Variability on the Hanford Site

Migration of groundwater contaminants in the Gable Gap area of the Hanford Site in southeastern Washington State is strongly influenced by the distribution and permeability of basalts that lie beneath an unconfined aquifer. Locally, folding and faulting of the Columbia River Basalt associated with the Yakima fold and thrust belt followed by erosion due to the Lake Missoula floods resulted in a complex basalt surface that represents either an impermeable lower boundary to the unconfined aquifer system or localized regions of increased permeability that potentially promote communication between the unconfined aquifer system and deeper, confined aquifer systems. Paleo-channels carved into the basalt by floodwaters are thought to provide preferential flow paths for groundwater contaminants. In 2011, a seismic landstreamer campaign was carried out to image the basalt surface and produced pre-stack depth migrated p-wave reflection images. The reflection images identified two large troughs that may represent paleo-channels and several areas of possible faulting. Here, the streamer data are re-analyzed using refraction travel-time and Rayleigh wave dispersion analyses to obtain images of compressional and shear wave velocities within the suprabasalt sediment sections and the upper basalt surface. The combined interpretation of reflection and seismic velocity images shows complexity in the basalt velocity and elevation, which varies by 50 m or more within the study area. These results, along with other ongoing geophysical investigations, will be used to inform the site geologic model and potentially guide placement of future boreholes needed to quantify vertical flow between the confined and unconfined aquifers.

58 GEOSCIENCES↗

Sodium Ion Expansion Power Block for Distributed CSP

The Sodium Ion Expansion Power Block for Distributed CSP was a three-plus-one-year effort under the Concentrating Solar Power: Advanced Projects Offering Low LCOE Opportunities (CSP: APOLLO) funding program within the U.S. Department of Energy Solar Energy Technologies Office. The primary objective of this project is to develop a dual-stage modular sodium thermal electrochemical converter (Na-TEC) heat engine power block, which can be potentially integrated with either a small-scale dish solar or large-scale heliostats and parabolic trough CSP. Na-TEC is a heat engine that generates electricity through the isothermal expansion of sodium ions. The Na-TEC is a closed system that can theoretically achieve conversion efficiencies above 45% when operating between thermal reservoirs at 1150 K and 550 K. However, thermal designs have confined previous single-stage devices to thermal efficiencies below 20%. To mitigate some of these limitations, we consider dividing the isothermal expansion into two stages; one at the evaporator temperature (1150 K) and another at an intermediate temperature (650 K –1050 K). This dual-stage Na-TEC takes advantage of regeneration and reheating, and could be amenable to better thermal management. In light of this, we first designed and developed a thermo-electrochemical model, and thermodynamically demonstrated how the dual-stage device can improve the efficiency by up to 8% points over the best performing single-stage device. We also established an application regime map for the single- and dual-stage Na-TEC in terms of the power density and the total thermal parasitic loss. Moreover, a thermal design of an axisymmetric dual-stage Na-TEC is developed to guide the scale-up and fabrication of sub-components of prototype module. A reduced-order finite-element model is used in conjunction with a Na-TEC thermodynamic model that was developed to determine the total parasitic heat loss of this dual-stage design. A number of simplifications are applied in the reduced-order model to decrease the computational time while maintaining acceptable accuracy. According to this analysis, a maximum efficiency of 29% and a maximum power output of 125 W can be achieved. Ultimately, we were able to demonstrate thermal efficiency improvements of the Na-TEC heat engine from 19% up to 40.3%, in a dual-stage (non-optimized) prototype module that we designed, fabricated, and tested with high temperature stage at 923 K. Furthermore, a cost-performance analysis for this improved dual-stage design was carried out for distributed-CSP systems. A high-level techno-economic analysis (TEA) explores four scenarios where a Na-TEC is used as the heat engine for a distributed-CSP system. Overnight capital cost and levelized cost of electricity (LCOE) are estimated for a system lifetime of 30 years, revealing that overnight capital costs in a range from $3.57 to $17.71 per We are feasible, which equate to LCOEs from 6.9 to 17.2 cents/kWh e -1 . This analysis makes a significant contribution by concurrently quantifying the efficiency and unit costs for a range of multistage configurations, and demonstrating that a Na-TEC may be a promising alternative to Stirling engines for distributed-CSP systems at residential scale of 1–5 kW e .

14 SOLAR ENERGY↗

Enhancement of Optical Efficiency of CSP Mirrors for Reducing O&M Cost via Near-Continuous Operation of Self-Cleaning Electrodynamic Screens (EDS). Final Report

Over the past decade, techno-economical advancements in solar energy systems, particularly the improvement in the conversion efficiency of PV modules made with mono-crystalline silicon solar cells from 12% to 20%, as well as the cost reduction in manufacturing by a factor of about 10%, have made it possible to achieve a levelized cost of electricity (LCOE) in PV plants that is comparable to, or less than, the cost of deriving electricity from fossil fuels. Operating PV plants in mid-latitude sun-belt regions, where the solar irradiance level is highest, provides a high annual energy-yield (kWh/kWp) due to two factors: (1) the availability of predictable high solar irradiance throughout the year with the fewest interruptions in solar flux from clouds and rain, and (2) the increased conversion efficiency of crystalline solar cells, as recombination loss has decreased with increased intensity of the sunlight that illuminates the silicon solar cells. Semi-arid and desert regions, however, are plagued by high atmospheric dust concentrations and frequent sand storms. The deposition of a layer of dust on the optical surfaces of solar collectors such as PV modules and concentrating mirrors reduces the transmission efficiency of sunlight that actually reaches the solar cells or receivers, resulting in high energy-yield soiling loss. There are two major cost components to operating a solar plant: (1) installation costs, and (2) operation-and-maintenance (O&M) costs. There is no fuel cost; hence operating a solar plant in a semi-arid or desert region provides high returns on investment if soiling losses are mitigated via efficient cleaning methods and optimized cleaning frequency. If solar collectors are not cleaned, the accumulation of dust layers on solar collectors may cause the operation of such plants in arid regions to become economically unviable. Washing solar collectors with water and detergent, as is most commonly done now, is an efficient method for cleaning. The conventional approach in utility-scale solar plants is to use a large truck with a water tank and pump system for spraying deionized water on the surface of the solar collectors. Robotic cleaning with brushes, used for many solar plants, requires lesser water for cleaning. The water consumed using semi-automated cleaning of PV modules in utility-scale solar plants is approximately 2 liters/m 2 per cleaning cycle. The total optical surface area of the solar collectors in 1 TW-scale solar installation will be more than 3 × 109 m 2 ; hence an enormous amount of water be needed for cleaning. There simply is not enough fresh water in the sun-belt areas of the world for predicted cleaning needs. In solar power plants, the estimated cost of cleaning solar collectors includes expenses related to the equipment used, labor, cost of transportation of water, the energy required for cleaning, plus ancillary costs whereas the cost of water is not considered. The water used is obtained from sources located close to plant sites, unmindful of the environmental and societal impact as the power plants are oftentimes located in regions that face severe drought. This practice is very similar to the cost calculations in deriving the levelized cost of electricity (LCOE) in conventional power plants based on burning fossil fuel such as coal and gas, while disregarding the cost of climate change and health effects. Unless a water-free or low-water cleaning method is established, the expansion of solar plants may lose public support in areas suffering long intervals of drought. The goal of this research project has been the development and application of the Electrodynamic Screen (EDS) as a means for a water-free, scalable cleaning process applicable to solar-power installations, including rooftop applications. We describe here the development of an EDS film-based cleaning process as an emerging method for use on PV modules, parabolic troughs, and heliostats. This report aims to show the feasibility of integrating or retrofitting EDS films onto the optical surfaces of solar collectors (both PV and CSP) while maintaining high transmission or reflection efficiency. The cleaning action provided by the EDS film is an active method to remove dust deposits by electrodynamic force. Current lab-scale prototype EDS films, retrofitted onto solar panels and mirrors, have shown to be capable of maintaining optical transmission or specular-reflection efficiencies higher than 90% of initial values under clean conditions. The optical surfaces of solar collectors laminated with EDS films can remove more than 90% of deposited dust when the EDS is activated for less than two minutes. As an electrodynamic dust removal process, the EDS film-based method is designed primarily for the removal of dust in solar installations located in semi-arid and desert areas, where the atmosphere is often dry and dusty and rainfall is infrequent. While EDS film application minimizes water consumption and facilitates cleaning as frequently as needed, it has limitations in removing contaminants such as soot, organic pollutants deposited as fine films on the surface, and bird droppings. The dust removal efficiency of the EDS is maximum at relative humidity RH is 40 to 50% and decreases at when RH > 65%. Many solar plant sites undergo diurnal and seasonal cycles of high ambient, early afternoon temperatures and an RH that reaches the dew point early in the morning. These variations in atmospheric conditions do not limit the operation of the EDS film. This report presents a brief review of the progress and the potential of EDS film technology for mitigating the impact of dust on solar collectors via water-free cleaning, as well as current technical challenges regarding efficiency and durability. Our experimental data on the performance of EDS films show that: (1) the dust-removal efficiency (DRE) can reach levels higher than 90%, (2) the specular reflectivity (SR) of EDS film-laminated second-surface mirrors reach levels in excess of 90%, (3) the specular reflectivity restoration (SRR) can exceed 90%, (4) the output-power restoration (OPR) of PV modules can exceed 95%, and (5) the optical transmission efficiency (TE) of the EDS films can be greater than 90%. Working with Sandia National Laboratories (NM), Corning Research and Development Corporation (NY), Eastman Kodak (NY), Tomark-Worthen Industries (NH), and EDS Chile SPA (Chile), we have produced EDS film-laminated PV modules and demonstrated their self-cleaning functions without requiring water. We have demonstrated that the operational range of EDS films will cover the expected ambient temperature of solar fields at RH cycling varying from 20 to 95% as long as the EDS films are activated in the RH range 20 to 50%. (Typical solar-field climates in deserts and semi-arid lands often reach near dew point in coastal areas.) Our experiments on the application of hydrophobic-fluorinated nanoparticle coatings on EDS film surfaces show that the EDS operational range can be extended to higher RH levels that approach the dew point. At Eastman Kodak, as one of our industrial partners, we were able to establish a process for manufacturing EDS films using flexographic printing of the electrodes onto transparent polymer films. This process utilizes an existing manufacturing line at Eastman Kodak that allows fabrication of medium-scale EDS films (26 cm × 30 cm). The manufacturing process has the capacity to produce EDS films at high production speeds. The medium-scale EDS films that have been printed at Kodak were evaluated in the lab at Boston University. The EDS films produced at Kodak were laminated at Tomark-Worthen using an industrial scale vacuum laminator to produce EDS film stacks, which can be affixed onto the optical surfaces of PV modules or concentrating mirrors. The EDS film stack consists of the EDS films that have Willow® Glass (WG) which has a thickness of 100 μm as the front surface. The WG sheets obtained from Corning Research and Development Corporation are customized in size and shape to cover the active area of the EDS films. The back surface of the EDS film stack is integrated onto the optical surface of the solar panel or mirror using optically clear adhesive (OCA) films or silicone adhesives. The OCA films (thickness 25 μm) are produced by 3M. The EDS film stacks have the architecture: WG/OCA/EDS Film/OCA/ over PV module or solar mirror. The power-supply units needed for activating the electrodes of the EDS film were designed and produced at Boston University. These power supply units provide three-phase, 1.2 kV voltage pulses at a very low current (micro-ampere) level and at a low frequency (≈ 5 Hz). The voltage pulses are applied to the electrodes in a sequence such that the train of pulses resembles a unidirectional traveling wave of electrical field on the surface of the EDS film. The dust particles on the surface become charged electrostatically and are levitated by the Coulomb force. The lateral sweeping action of the traveling electric field created by the three-phase voltages pulses then sweeps the dust off the surface. The energy consumed by the EDS electrodes is less than 0.2 Wh/m 2 /cleaning cycle, enabling energy-efficient restoration of output power (OPR) of PV module or specular reflectivity restoration (SRR) for solar mirrors. The EDS system consists of (1) an EDS film stack laminated onto the solar collectors, (2) connection of the EDS film to its power supply unit and (3) Interconnection of the power supply to PV modules or solar mirrors. Design, construction and assessment of field-testing units that have EDS stack laminated PV modules for evaluating the performance of the EDS films in solar fields is being carried out at BU. Our progress under this project, aimed at the advancement of EDS film technology, has reached DOE Technology Readiness Level (TRL) 6. Based on the extensive laboratory evaluations and limited field trials, as well as contacts with potential users, we believe that the technology has reached its commercial stage. We are conducting a cost analysis using the National Renewable Energy Laboratory (NREL) System Advisory Model (SAM) and are preparing for field trials of EDS films in different solar fields in the US, Chile, India and in the Middle East. A brief description of EDS film performance, construction and testing of the field-test unit, autonomous operation of the field-test unit for evaluating EDS performance in increasing energy yield, associated revenue savings, and water conservation is presented.

14 SOLAR ENERGY↗

Atomically Precise Membranes for the Separation of Gases

Industrial separations require enormous amounts of energy, accounting for approximately half the industrial energy use and 10–15% of the total energy consumption. Distillation alone accounts for about half the energy demand for industrial separations. If these processes could be replaced by an energy-efficient membrane separation process, this energy demand could be reduced by 90%. However, although some membrane processes have made inroads into thermal distillation, for membrane-based separations to replace the distillation process to a far more significant and practical level, new membranes with higher robustness, selectivity, and flux still need be developed. In this membrane development program, we leveraged Temple University’s prior work in spiroligomers to develop robust membrane structures. These structures can be formed into atomically precise pores by controlling the chemical synthesis and the oligomer building blocks to first build precisely controlled macrocycles and then subsequently crosslinking these macrocycles to produce a membrane. Furthermore, through the highly controllable chemistry of our molecular building blocks, not only can we integrate pores with highly controllable and reproducible size and morphology, but we can also target internal functionalization. By using a range of scalable membrane synthesis approaches, combined with control of each and every pores internal chemistry and molecular conformation we can achieve membrane structures that can display the ultimate in high selectivity and permeance. The Mainstream-Temple University membranes can be designed to achieve ultra-selective separations based on the key factors of molecular size, shape, and functionality. In our approach to fabricate scalable atomically precise membranes, we used our molecular Lego nanostructures. We demonstrated an approach to create atomically precise pores within the membrane with pores that are the dimensions of the molecule we are trying to separate. Moreover, in addition to controlling the morphology of the membrane structure by controlling the size of every pore, we can also decorate every pore with precisely targeted and placed functional groups. These accurately placed functional groups can provide selective binding to molecules and provide enhanced selectivity via a facilitated transport mechanism. In Phase II, the Mainstream-Temple University team demonstrated the scalable synthesis of oligomers and the ability to control the pore internal and external functionality, or chemistry, to allow the fabrication of a thin-film membrane. The initial steps of the spiroligomer synthesis to produce the two key bis-amino enantiomer building blocks were scaled from the gram scale to the kilogram scale, obtaining 25 kg of the materials by transferring the procedure to a toll manufacturer. Finally, we successfully optimized the fabrication of these macrocycles into robust membranes. We successfully transitioned from a laboratory based, hard-to-scale Langmuir trough synthesis to a highly scalable, roll-to-roll applicable, interfacial polymerization process. During this Phase II program, we established a platform of atomically precise membranes where our highly controllable, atomically precise macrocycles served as a scaffold with precisely and uniformly controlled pores. Furthermore, this layer can be tailored to accommodate a diverse range of functional groups, which both further controlled the pore size to enhance the sieving effect as well as imparting precisely controlled targeted selectivity through biomimetic molecular interactions. In this Phase II, we established and scaled up a platform approach to both tune the pore size and chemistry as well as scale it to produce membranes that can be applied to a wide range of industries. In future development, the project team expects to scale up both the macrocycle building block production and interfacial polymerization process to produce the atomically precise membrane with targeted pore sizes and pore chemistries.

36 MATERIALS SCIENCE↗

Integration of Wireless Sensor Networks and Battery-free RFID for Advanced Reactors

To address an important need for Nuclear Power Plants (NPPs) to significantly reduce the amount of the required cables for sensor data communications, this Phase I SBIR effort successfully developed and demonstrated a novel low-cost proof-of-concept prototype of a secure wireless sensor network backbone communications system. This system combines commercially available low power, low cost XBEE wireless communications network and passive (battery-free) Radio Frequency Identification (RFID) systems to report individual sensor data and their location through the containment wall for rapid response to anomalies in nuclear facilities. This WIreless Sensing and Locating (WISLO) system network architecture allows non-intrusive wireless collection of sensor data with the sensor’s accurate location information from inside of the instrumentation or containment area with minimal need for power sources. The multi-node sensor data in the containment area is wirelessly transmitted to outside through the metal reinforced concrete walls without the need for any batteries. The WISLO system could be readily used in current reactor fleet and future advanced reactors, as well as in small modular reactors (SMR). The WISLO system is the first dual frequency battery-free trough the wall communications backbone system developed specifically for use in nuclear power plants. It not only can modernize the sensor monitoring practices in the existing reactor fleet, but also offers a secure, low-cost solution to advanced reactors and SMRs by removing cables and issues related to them such as cable integrity, reporting delays, and installation and maintenance costs. The intent is to improve process safety, reliability, efficiency, and cost effectiveness to the monitoring and maintenance process in current and future plants. As we address the next productization and manufacturing capabilities in the next phase, this system will serve the needs of many commercial and government applications in remote monitoring of sensor data that demand battery-free transmission of sensor data such as Internet-of-Things (IOT).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Temperature Linear Receiver Enabled by Multicomponent Aerogels

Concentrating solar thermal (CST) technology has significant potential mainly due to its dispatchability and low cost of storage. However, to compete with other sources, including utility-scale solar PV, its final cost (cents/kWh) still needs to be lowered. Cost reduction can be achieved by improving the system level efficiency of the CST plants through the deployment of advanced power cycles, which operate at high temperatures of ~700°C. However, optical, and thermal losses pose a major challenge to the efficiency of such CST systems. The overall aim of this project is to investigate and de-risk a linear solar receiver concept called an Aerogel Insulated Receiver (AIR) that generates high temperatures (up to 700°C) at a low solar concentration ratio (<100) and with a high collection efficiency (optical × receiver). Our prior work has demonstrated the thermal stability1 and optical and heat-insulating properties2,3 of transparent aerogel insulation at a one-inch scale. The focus of this work is on (1) co-optimization of the geometry of the aerogel tile and receiver enclosure to fit a standard parabolic collector (PTC), (2) scale-up of aerogels into 4-inch tiles while preserving key properties, (3) experimental measurement of receiver heat loss (W/m) in a >70-cm test stand and validation of anticipated receiver performance at high temperatures. Regarding (1), appropriate optical and thermal models for a parabolic trough receiver (PTR) are developed and validated. The geometry of the aerogels and the receiver enclosure are co-optimized to maximize the collection efficiency. The model predicts a 54% collection efficiency at 700°C for an AIR design based on flat aerogels. By combining the collection efficiency with the power block efficiency of supercritical CO 2 cycles, we predict >10% improvements in peak plant efficiency relative to existing line-focusing CST systems. The application of curved plasmonic aerogels is predicted to further increase the collection efficiency to 64%. Regarding (2), we demonstrate the successful development of 6-inch-long refractory aerogel tiles with optical, thermal, and stability characteristics consistent with our prior work. This scale-up requires a transition to a larger ALD station and modifying the ALD process variables such as exposure time and the number of precursor doses. Regarding (3), we design and develop an AIR test stand measuring 3 feet in length. Heat loss performance analysis is carried out using the test stand. The results indicate that aerogel insulation can significantly reduce receiver thermal losses at the high operating temperatures required for next-generation PTRs. The experimental results agree with the heat loss performance predicted by our receiver model. Lastly, we conducted preliminary failure mode and effects (FMEA) and techno-economic (TEA) analyses to identify failure mitigation strategies and commercial opportunities, respectively. Overall, this project identifies key opportunities and challenges in deploying aerogel insulating receivers in next-generation line-focusing CST technologies.

14 SOLAR ENERGY↗

Thermodynamically Stable, Plasmonic Transition Metal Oxide Nanoparticle Solar Selective Absorbers towards 95% Optical-to-Thermal Conversion Efficiency at 750 °C

Generation 3 (Gen) concentrating solar power (CSP) systems requires a high operation temperature ≥750°C to increase the power-cycle efficiency towards ≥50%. However, such a high operation temperature poses a notable challenge to high temperature materials. On the receiver side, a critical challenge is the lack of solar selective absorbers that demonstrate both high optical-to-thermal energy conversion efficiency η therm approaching 95% and long-term thermal stability at >750°C in air. Existing solar absorbers either have limited η therm ≤89% or deteriorate significantly within 500 h at 750°C; some of these also require costly vacuum deposition for stringent thickness control. Therefore, it is highly desirable to simultaneously achieve η therm ~95% AND high thermal stability at 750°C for future generations of CSP receivers. This project has investigated and developed low-cost, highly scalable spray-coated transition metal oxide nanoparticle (NP) pigmented solar selective coatings on various types of Inconel alloy tube sections that are thermodynamically stable at 750-800°C in air, maintaining η therm >94.3%(93.2%) under a solar concentration ratio of C=1000 after 60 simulated day-night cycles at 750ºC (800ºC) (1 cycle=12 h at 750 or 800°C and 12h ramping down to 25°C). We have also coated up to 48 inches long receiver tubes for preliminary solar testing under Norwich Technology’s parabolic trough systems, demonstrating notably improved performance in solar heating compared to benchmark Pyromark 2500 coatings. Two key innovations have been developed in this project: (1) We achieved an unprecedented high thermal efficiency >94% by optimizing the d-band optical absorption spectra of transition metal ions, engineering their valences and stoichiometry; (2) We were able to maintain or even slightly increase the efficiency when operating at 750°C in air by engineering the interdiffusion of transition metal ions between the coating and the Inconel substrate to our advantage. Featuring high-temperature solar spectral selectivity and thermodynamic stability in air, as well as low-cost, highly scalable solution-chemical synthesis and spray coating techniques, this innovation in solar selective absorber technology alone accounts for nearly 40% of the targeted reduction in the levelized cost of electricity (LCOE) from the receiver, thermal energy storage, and operation & maintenance combined by 2030, as proposed by the U.S. Department of Energy. For a 110 MWe CSP power plant, this LCOE reduction from the solar selective coating alone transfers to ~$\$ $1.9 M increase in annual profit based on a sales price of 10¢/kWh (or an annual sale of $50 M/year). The high solar absorptance (~98%) NP pigment materials developed in this project are equally applicable to volumetric receivers either as a coating or as bigger ceramic microspheres after sintering, potentially benefiting Gen3 falling particle CSP technologies. All these contributions facilitate the larger scale deployment of CSP systems with energy storage capability to address the intermittency issue of solar energy towards dispatchable solar electricity, bridging the temporal gap between peak solar electricity production and peak electricity consumption. The collaboration with Norwich Technologies and Brayton Energy in this project will also facilitate the future commercialization of this new solar selective coating technology developed in this SIPS project.

14 SOLAR ENERGY↗

Re-Designing the CSP Thermal Energy Storage System to Enable Higher-Temperature Performance at Reduced Cost (Final Technical Report)

Current commercial concentrating solar power (CSP) plants distinguish themselves from ordinary photovoltaic (PV) power plants by storing enough collected energy to enable generation for several hours after the sun goes down. CSP plants store this energy in the sensible heat of nitrate salts in large metallic storage tanks. Stainless-steel AISI 347H (SS347H) is needed for the hot tank operating at about 565 degrees C whereas carbon steel is sufficient for the cold-tank materials. Two-tank nitrate-salt thermal energy storage (TES) is presently in use in several trough-based CSP plants in Europe and in the U.S., operating up to about 390 degrees C. Three commercially operating tower-based CSP plants - Gemasolar in Spain, Crescent Dunes in Nevada, and Noor III in Morocco - use the same approach, storing nitrate salts at temperatures up to 580 degrees C. SS347H is many times more expensive than carbon steel and constitutes a significant cost element in today's CSP plants. Hence, CSP developers need to close the cost gap with PV-based solar plants by making cost reductions in every system of the plant. Redesigning the TES tanks is one opportunity for cost reduction.

14 SOLAR ENERGY↗

Loop Thermosyphon Enhanced Solar Collector

A two-phase loop thermosyphon solar collector was developed to transfer thermal energy efficiently and passively from a concentrated solar collector to a thermal desalination process. The two-phase flow in the loop thermosyphon is driven by a difference in gravitational pressure head between the liquid return line and the two-phase riser located between the evaporator and condenser. A numerical model incorporating mass, energy, and pressure drop balances was developed to predict system performance and use as a design tool. Three iterations of loop thermosyphon solar collectors were designed, fabricated, and tested to validate the numerical analysis and demonstrate system integration. Additionally, a novel solar receiver design was evaluated based on volumetric absorption of the concentrated sunlight by an optically absorptive two-phase working fluid. Life tests were performed to evaluate the working fluid thermal stability and resistance to ultraviolet degradation. A glass receiver tube and associated glass-to-metal junctions were developed. Finally, a full-scale loop thermosyphon was integrated with a parabolic trough solar collector and tested on-sun.

14 SOLAR ENERGY↗

SOFAST CAD Layout Tool Overview and User Guide (Document Version 1.0)

Concentrating solar mirrors need to have correct geometry to accurately focus sunlight onto a receiver. SOFAST is a tool created at Sandia National Laboratories which measures a mirror’s surface normal at a dense sampling of points, enabling evaluation of a given mirror’s expected performance. SOFAST supports general mirrors, including concentrating solar heliostats, troughs, and dishes. The examples presented in this report predominantly focus on heliostats.

14 SOLAR ENERGY↗

FY2023 NSTTF Annual Report

The National Solar Thermal Test Facility (NSTTF) is a DOE Core Capability and Technology Deployment Center located in Albuquerque, NM. It is operated by Sandia National Laboratories (Sandia) for the U.S. Department of Energy (DOE). The NSTTF is the only multi-mission, multi-use, multi-story test facility of its type in the United States. The NSTTF was founded in 1978 and began testing with high heat flux that same year. Over the past 45 years, the NSTTF has been at the forefront of the research, design, fabrication, and testing of many of the critical Concentrating Solar Power (CSP) technologies. These technologies have allowed costs to be dramatically reduced from over $\$ $0.40 /kWh to $\$$0.12 /kWh since the conception of this renewable energy technology. The NSTTF has worked to make the Solar Energy Generating Systems (SEGS) parabolic trough plants successful, while also working with the Solar One and Solar Two facilities for successful implementation. Over the four decades since its founding, the mission of the NSTTF has grown to include new receiver technologies, like our generation 3 falling particle system (G3P3 Tower), optical metrology techniques like SOFAST, molten salt testing, thermal energy storage, solar thermal chemistry, and more. We continue to expand our capabilities in pursuit of the DOE SETO mission and the DOE SunShot 2030 goals: unsubsidized LCOE of $\$$0.05/kWh for CSP that includes 12 or more hours of thermal energy storage. To support both the DOE SETO mission and support the CSP sector as a whole, we are working to develop our operations and maintenance framework to provide a world class testing facility in support of our technological achievements. To accomplish both of these missions, the NSTTF draws on the decades of experience and expertise of our staff along with the world-class facilities at Sandia National Laboratories to further the science of concentrated solar thermal technologies in diverse applications. We remain a trusted partner for high-quality and impactful research in both fundamental and applied arenas. We are able to provide our partners with both one-of-a-kind testing platforms as well as world-class analytics.

14 SOLAR ENERGY↗

Preliminary Results of the 3D-shape Round-Robin

In the framework of SFERA-III WP10 Task3, ENEA has organized the 3D-shape round-robin (RR); the purpose is to compare the main geometrical parameters of 3D shape measurement of parabolic-trough (PT) reflective panels evaluated with the instruments adopted by each participant among: ENEA, DLR, F-ISE, NREL, and SANDIA. The last two institutions are outside of the EU, but benefited from the Transnational Access institute to visit several European laboratories, including the ENEA Casaccia research center where they accomplished some measurements with a portable experimental set-up. RR is based on the inter-laboratory circulation of 3 inner plus 3 outer PT panels. The start of the RR was delayed by the covid pandemic, then the circulation of the specimen-set and their measurement took more than one year. At the time of drafting this deliverable at the end of SFERA-III project, NREL has not yet completed the analysis of the measurements, making available only the deviations of the slopes. Therefore here will be reported only the preliminary results. The full comparison will be published as soon as possible, maybe in the open access venue Open Research Europe.

14 SOLAR ENERGY↗

Predicting seismic amplitudes with machine learning

The accurate estimation of seismic wave amplitude is vital to precisely determine the yield, magnitude, and event discrimination possible for a given network – a critical element in nuclear explosion monitoring. This task is complicated by several factors, including but not limited to radiation pattern, scattering effects, and crustal variations, which can lead to the attenuation or amplification of amplitude along a given raypath. In this report, we explore the novel application of machine learning to the task of seismic amplitude estimation by training a simple Artificial Neural Network (ANN) on an S-wave amplitude dataset from Lai et al. (2019). Attributes from this dataset used as input to the ANN included event-station distances, station locations (latitude, longitude), event locations (latitude, longitude), event depths, event magnitudes, radiation patterns, signal-to noise ratio (SNR) measurements (average-amplitude, peak-to-trough, maximum peak), and signal periods. We find that the trained ANN predicts S-wave amplitudes with a modest tendency toward underestimating the actual values, as indicated by a linear regression between predicted and actual data (slope: 0.892, intercept: -0.651). These results suggest that an ANN can perform this task, with potential for significant improvements through improved datasets, architectures, and parameter tuning.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗