Slow Detrapping Transients due to Gate and Drain Bias Stress in High Breakdown Voltage AlGaN/GaN HEMTs.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Abstract Not Provided
Abstract Not Provided
High Voltage Direct Current (HVDC) transmission lines are being constructed throughout the world, aided by advancements in power electronics and the potential value to transfer power between distant areas and off-shore locations. Multiple HVDC lines within and across large AC interconnections could bring about economic benefits such as interregional capacity exchange, and transfer of low-cost, distant electric energy directly to load centers. In addition, network configuration of HVDC lines could result in additional benefits that have not been deeply studied. This paper describes the modeling process for continental-level power system interconnections with the addition of multiple HVDC lines configured as a macrogrid. The models used for study are based on industry-accepted power-flow and dynamic system models for the North American Eastern and Western Interconnections. The model provides insight on feasibility and initial steady-state and stability tests of the HVDC macrogrid and its interactions with the existing electricity infrastructure, opening the door to analysis of the technical value of such a macrogrid.
Explore the source record for details and available documents.
EXECUTIVE SUMMARY The Transient Reactor Test facility (TREAT) was constructed in the late 1950’s and provided thousands of transient irradiations before being placed in standby mode in 1994. In 2017, it resumed operation in order to reclaim its crucial role in nuclear-heated safety research. TREAT is a transient reactor where inherently-safe core physics, a nimble transient rod drive system, and a philosophy of continual facility improvement work together to enable flexible power maneuvers for fuel safety research. While the facility’s flexible design and multi-mission nature saw historic experiments for numerous transient types, TREAT was not specifically adapted to optimize or demonstrate its full performance capability for Light Water Reactor (LWR) postulated accidents including Hot Zero Power Reactivity Initiated Accidents (HZP-RIA) and Loss of Coolant Accidents (LOCA). The physics of HZP-RIA drive very brief pulses with fairly large energy excursions. TREAT is currently capable of approaching HZP-RIA pulse widths through transients initiated on a large step insertion of reactivity and terminated shortly thereafter by rapid re-insertion of the transient rods (“clipping”). LOCAs are postulated to occur quite differently, starting from normal power operations followed by a long period of lower power decay heat. TREAT is able to simulate LOCA events with an initial flattop transient for tens of seconds, followed by a sizeable power reduction, to a longer segment where specimen fission heating represents internal decay heat generation. Two reactor physics testing campaigns were undertaken to address the HZP-RIA type transients, neither of which had been performed in any great measure historically to address data gaps in the timing, repeatability of clipping and effect of dynamic transient rod motions on core-to-specimen fission power coupling. The first campaign, referred to as the Accident Tolerant Fuel (ATF) transient prescription tests, employed dosimeters in the core to characterize the effect of rod motions on specimen power coupling for clipped, unclipped, and low-level steady state operations each with approximately the same moderate core energy release. This campaign was accompanied by efforts to measure dosimetry and compare results to analytic predictions. The other HZP-RIA campaign, referred to as Narrow Pulse Width (NPW) transient prescriptions, employed higher step insertions with increased core energy release to demonstrate TREAT’s capability in achieving the narrowest-possible pulse width. Additionally, a series of LOCA transient prescriptions were also performed to demonstrate how well TREAT could perform long-duration shaped transients. Both NPW and LOCA transient prescriptions did not include dosimeters but used existing plant power instrumentation to produce transient power data. All three transient prescription campaigns were successfully carried out in TREAT. The ATF-3 transient prescriptions showed that TREAT can perform clipped transients with remarkable repeatability. Measurement and modeling both showed that the power coupling in small, fissile dosimeters does not change by more than 8% between clipped, unclipped, and steady state runs while uncertainty sources in both the modeling and measurement methods were identified and found to be on the order of 20% in total. Overall, the ATF-3 transient prescription tests were successful in determining repeatability and consistency of dosimeter power coupling, developing processes for modeling and measuring this crucial parameter, and demonstrating the need for continued efforts in transient prescription work at TREAT in support of future experiment design and post test data interpretation. The NPW and LOCA transient prescriptions were also successfully performed to exhibit TREAT’s capability for these important LWR accident categories. The NPW transients showed pulse widths of ~90 ms, which were the narrowest ever achieved in TREAT to date and relevant for the upper end range of HZP-RIA simulation. This effort provided crucial data for calibrating kinetic models to be used in enhanced pulse-narrowing strategies in upcoming irradiations. Similarly, The LOCA transient prescriptions showed that TREAT can simulate the needed nuclear heating and event time scales for LOCA fuel safety research and provided essential data for future experiment design.
The figure shows a prototype of a relatively inexpensive electronic monitoring apparatus that measures and records selected parameters of lightning-induced transient voltages on communication and power cables. The selected parameters, listed below, are those most relevant to the ability of lightning-induced transients to damage electronic equipment. This apparatus bridges a gap between some traditional transient-voltage recorders that record complete waveforms and other traditional transient-voltage recorders that record only peak values: By recording the most relevant parameters and only those parameters this apparatus yields more useful information than does a traditional peak-value (only) recorder while imposing much smaller data-storage and data-transmission burdens than does a traditional complete-waveform recorder. Also, relative to a complete-waveform recorder, this apparatus is more reliable and can be built at lower cost because it contains fewer electronic components. The transients generated by sources other than lightning tend to have frequency components well below 1 MHz. Most commercial transient recorders can detect and record such transients, but cannot respond rapidly enough for recording lightning-induced transient voltage peaks, which can rise from 10 to 90 percent of maximum amplitude in a fraction of a microsecond. Moreover, commercial transient recorders cannot rearm themselves rapidly enough to respond to the multiple transients that occur within milliseconds of each other on some lightning strikes. One transient recorder, designed for Kennedy Space Center earlier [ Fast Transient-Voltage Recorder (KSC- 11991), NASA Tech Briefs, Vol. 23, No. 10, page 6a (October 1999)], is capable of sampling transient voltages at peak values up to 50 V in four channels at a rate of 20 MHz. That recorder contains a trigger circuit that continuously compares the amplitudes of the signals on four channels to a preset triggering threshold. When a trigger signal is received, a volatile memory is filled with data for a total time of 200 ms. After the data are transferred to nonvolatile memory, the recorder rearms itself within 400 ms to enable recording of subsequent transients. Unfortunately, the recorded data must be retrieved through a serial communication link. Depending on the amount of data recorded, the memory can be filled before retrieval is completed. Although large amounts of data are recorded and retrieved, only a small part of the information (the selected parameters) is usually required. The present transient-voltage recorder provides the required information, without incurring the overhead associated with the recording, storage, and retrieval of complete transient-waveform data. In operation, this apparatus processes transient voltage waveforms in real time to extract and record the selected parameters. An analog-to-digital converter that operates at a speed of as much as 100 mega-samples per second is used to sample a transient waveform. A real-time comparator and peak detector are implemented by use of fast field-programmable gate arrays.
The NEUP funded project, NEUP-3496, aims to experimentally investigate two-phase natural circulation flow instability that could occur in Small Modular Reactors (SMRs), especially for natural circulation SMRs. The objective has been achieved by systematically performing tests to study the general natural circulation instability characteristics and the natural circulation behavior under start-up or design basis accident conditions. Experimental data sets highlighting the effect of void reactivity feedback as well as the effect of power ramp-up rate and system pressure have been used to develop a comprehensive stability map. The safety analysis code, RELAP5, has been used to evaluate experimental results and models. Improvements to the constitutive relations for flashing have been made in order to develop a reliable analysis tool. This research has been focusing on two generic SMR designs, i.e. a small modular Simplified Boiling Water Reactor (SBWR) like design and a small integral Pressurized Water Reactor (PWR) like design. A BWR-type natural circulation test facility was firstly built based on the three-level scaling analysis of the Purdue Novel Modular Reactor (NMR) with an electric output of 50 MWe, namely NMR-50, which represents a BWR-type SMR with a significantly reduced reactor pressure vessel (RPV) height. The experimental facility was installed with various equipment to measure thermalhydraulic parameters such as pressure, temperature, mass flow rate and void fraction. Characterization tests were performed before the startup transient tests and quasi-steady tests to determine the loop flow resistance. The control system and data acquisition system were programmed with LabVIEW to realize the realtime control and data storage. The thermal-hydraulic and nuclear coupled startup transients were performed to investigate the flow instabilities at low pressure and low power conditions for NMR-50. Two different power ramps were chosen to study the effect of startup power density on the flow instability. The experimental startup transient results showed the existence of three different flow instability mechanisms, i.e., flashing instability, condensation induced flow instability, and density wave oscillations. In addition, the void-reactivity feedback did not have significant effects on the flow instability during the startup transients for NMR-50. ii Several initial startup procedures with different power ramp rates were experimentally investigated to eliminate the flow instabilities observed from the startup transients. Particularly, the very slow startup transient and pressurized startup transient tests were performed and compared. It was found that the very slow startup transients by applying very small power density can eliminate the flashing oscillations in the single-phase natural circulation and stabilize the flow oscillations in the phase of net vapor generation. The initially pressurized startup procedure was tested to eliminate the flashing instability during the startup transients as well. The pressurized startup procedure included the initial pressurization, heat-up, and venting process. The startup transient tests showed that the pressurized startup procedure could eliminate the flow instability during the transition from single-phase flow to two-phase flow at low pressure conditions. The experimental results indicated that both startup procedures were applicable to the initial startup of NMR. However, the pressurized startup procedures might be preferred due to short operating hours required. In order to have a deeper understanding of natural circulation flow instability, the quasi-steady tests were performed using the test facility installed with preheater and subcooler. The effect of system pressure, core inlet subcooling, core power density, inlet flow resistance coefficient, and void reactivity feedback were investigated in the quasi-steady state tests. The experimental stability boundaries were determined between unstable and stable flow conditions in the dimensionless stability plane of inlet subcooling number and Zuber number. To predict the stability boundary theoretically, linear stability analysis in the frequency domain was performed at four sections of the natural circulation test loop. The flashing phenomena in the chimney section was considered as an axially uniform heat source. And the dimensionless characteristic equation of the pressure drop perturbation was obtained by considering the void fraction effect and outlet flow resistance in the core section. The theoretical flashing boundary showed some discrepancies with previous experimental data from the quasi-steady state tests. In the future, thermal non-equilibrium was recommended to improve the accuracy of flashing instability boundary. As another part of the funded research, flow instabilities of a PWR-type SMR under low pressure and low power conditions were investigated experimentally as well. The NuScale reactor design was selected as the prototype for the PWR-type SMR. In order to experimentally study the natural circulation behavior of NuScale iii reactor during accidental scenarios, detailed scaling analyses are necessary to ensure that the scaled phenomena could be obtained in a laboratory test facility. The three-level scaling method is used as well to obtain the scaling ratios derived from various non-dimensional numbers. The design of the ideally scaled facility (ISF) was initially accomplished based on these scaling ratios. Then the engineering scaled facility (ESF) was designed and constructed based on the ISF by considering engineering limitations including laboratory space, pipe size, and pipe connections etc. PWR-type SMR experiments were performed in this well-scaled test facility to investigate the potential thermal hydraulic flow instability during the blowdown events, which might occur during the loss of coolant accident (LOCA) and loss of heat sink accident (LOHS) of the prototype PWR-type SMR. Two kinds of experiments, normal blowdown event and cold blowdown event, were experimentally investigated and compared with code predictions. The normal blowdown event was experimentally simulated since an initial condition where the pressure was lower than the designed pressure of the experiment facility, while the code prediction of blowdown started from the normal operation condition. Important thermal hydraulic parameters including reactor pressure vessel (RPV) pressure, containment pressure, local void fraction and temperature, pressure drop and natural circulation flow rate were measured and analyzed during the blowdown event. The pressure and water level transients are similar to the experimental results published by NuScale [51], which proves the capability of current loop in simulating the thermal hydraulic transient of real PWR-type SMR. During the 20000s blowdown experiment, water level in the core was always above the active fuel assemble during the experiment and proved the safety of natural circulation cooling and water recycling design of PWR-type SMR. Besides, pressure, temperature, and water level transient can be accurately predicted by RELAP5 code. However, the oscillations of natural circulation flow rate, water level and pressure drops were observed during the blowdown transients. This kind of flow oscillations are related to the water level and the location upper plenum, which is a path for coolant flow from chimney to steam generator and down comer. In order to investigate the transients start from the opening of ADS valve in both experimental and numerical way, the cold blow-down experiment is conducted. For the cold blowdown event, different from setting both reactor iv pressure vessel (RPV) and containment at high temperature and pressure, only RPV was heated close to the highest designed pressure and then open the ADS valve, same process was predicted using RELAP5 code. By doing cold blowdown experiment, the entire transients from the opening of ADS can be investigated by code and benchmarked with experimental data. Similar flow instability observed in the cold blowdown experiment. The comparison between code prediction and experiment data showed that the RELAP5 code can successfully predict the pressure void fraction and temperature transient during the cold blowdown event with limited error, but numerical instability exists in predicting natural circulation flow rate. Besides, the code is lack of capability in predicting the water level related flow instability observed in experiments.
The goal of this work was to understand, quantify, and eventually predict combustion instability during operational transients in low-NO x gas turbine combustors. Transient operation is defined as a mode where one or more key operating parameters, including equivalence ratio, fuel composition, or fuel splitting between nozzles in a combustor, are varying in time. The timescale over which this variation occurs will be referred to as the transient timescale, the magnitude of the change in the transient parameter will be referred to as the transient amplitude, and the direction of the variation will be referred to as the transient direction. Transients occur regularly in power generation gas turbine operation. For example, load-following gas turbines vary load to meet power demands while accounting for variation in unsteady grid contributors like wind and solar power. Operators achieve this by varying equivalence ratio and fuel splitting inside the combustors to produce more or less power. Another example of transient operation is during fuel-switching operations, a particular issue for turbines operating with syngas fuels in a co-generation facility. In this case, the composition of the fuel stream may vary in time either as a result of fluctuations in the pipeline, or in the case of a co-generation plant, variations in feedstock or gasification processes. This fluctuation in fuel composition can have significant implications for combustion processes, particularly with high-hydrogen fuels. A small number of studies have investigated transient behavior in gas turbine combustors, particularly in the context of flame blow-off; here, investigators have typically focused on issues of transient amplitude, though without the depth and physics-based experimental design that is proposed in this program. To our knowledge, there have been no studies that have quantified the impact of the transient timescale on combustion. The work helped us understand the impact of several types of transients on combustion stability. Both static and dynamic combustion stability will be considered. The transients will be quantified using their amplitude, direction, and timescale, and we will consider transients in equivalence ratio, fuel composition, and fuel splitting. There were two main objectives of this work: 1. Provide a fundamental understanding of combustion stability during transient operation using data obtained from a number of high-speed diagnostic techniques on experimental configurations that capture important gas turbine combustor features and operating conditions. This goal was met in conjunction with our industrial partner, GE Global Research, with whom we worked closely throughout the program. 2. Develop a stability prediction framework that will allow for the prediction, and possible control, of instabilities as a function of the transient amplitude, direction, and timescale. This input/output model should be physics-based and allow for screening of operating conditions and prediction of unstable behavior at the end of a transient by monitoring combustor health and precursor signals during operation.
Combustion instability in gas turbine engines is often mitigated using fuel staging. Fuel staging, sometimes referred to as fuel splitting, is a strategy by which fuel is unevenly distributed between different nozzles of a multiple-nozzle combustor. These fuel splits are conducted in a transient manner in real engines, and the effects of these transients on instability are not well characterized. This work fills this gap by systematically studying the effects of transient fuel staging on self-excited combustion instability by varying the amount of staging fuel (staging amplitude), timescale in which the fuel is added (transient duration), and whether staging fuel is added or subtracted (transient direction). In this work, three staging amplitudes, five transient durations, and both transient directions are considered. The transient timescales are broadly divided into “short” duration transients, which have fuel delivery timescales shorter than the characteristic instability decay or onset timescales, and “long” duration transients, which have fuel delivery timescales longer than the characteristic instability decay or onset timescales. For short duration transients, we find the instability decay timescale depends on staging amplitude but does not depend on transient duration. For long duration transients, we find the instability decay timescale does not strongly depend on staging amplitude. The instability onset timescale is found to be longer and more variable between runs than the instability decay timescale for a given fuel delivery timescale. The onset timescale is also longer in duration and more variable than the decay timescale at a given fuel delivery timescale, implying that the instability rise process is overall more variable and slower than the instability decay process. Analysis of combustor damping rates show a strong dependence of damping rate on staging amplitude but no strong dependence on transient duration or direction. Instantaneous phase difference images between p' and are used to differentiate regions in the combustor that have constructive versus destructive interference between heat release rate oscillations and pressure fluctuations. Furthermore, the phase images show that p' and q . ' become in-phase early in the transient for the onset transients.
We present the Multi-Object Spectroscopy of Transient (MOST) Hosts survey. The survey is planned to run throughout the 5 yr of operation of the Dark Energy Spectroscopic Instrument (DESI) and will generate a spectroscopic catalog of the hosts of most transients observed to date, in particular all the supernovae observed by most public, untargeted, wide-field, optical surveys (Palomar Transient Factory, PTF/intermediate PTF, Sloan Digital Sky Survey II, Zwicky Transient Facility, DECAT, DESIRT). Science cases for the MOST Hosts survey include Type Ia supernova cosmology, fundamental plane and peculiar velocity measurements, and the understanding of the correlations between transients and their host-galaxy properties. Here we present the first release of the MOST Hosts survey: 21,931 hosts of 20,235 transients. These numbers represent 36% of the final MOST Hosts sample, consisting of 60,212 potential host galaxies of 38,603 transients (a transient can be assigned multiple potential hosts). Of all the transients in the MOST Hosts list, only 26.7% have existing classifications, and so the survey will provide redshifts (and luminosities) for nearly 30,000 transients. A preliminary Hubble diagram and a transient luminosity–duration diagram are shown as examples of future potential uses of the MOST Hosts survey. The survey will also provide a training sample of spectroscopically observed transients for classifiers relying only on photometry, as we enter an era when most newly observed transients will lack spectroscopic classification. The MOST Hosts DESI survey data will be released on a rolling cadence and updated to match the DESI releases.
A transient benchmark based on the Transient Reactor Test Facility (TREAT) M2 Calibration experiment (M2-CAL) is under development. TREAT, at Idaho National Laboratory, is a graphite moderated air-cooled research reactor which has been used extensively for fuel material testing under extreme and accident conditions. Accurate benchmark models are a beneficial component in the operations, experimental planning, and development of TREAT. In this work, we present a transient benchmark model for the M2-CAL experiment core loading. The benchmark model incorporates the coupling between the Monte Carlo Code SERPENT and the computational fluid dynamics code OpenFOAM to capture the temperature feedback mechanism. The M2-CAL transient 2580 was simulated in this work. A pre-transient analysis was performed to determine the optimum core composition and conditions before the beginning of the transient. The analysis was validated against historic TREAT kinetic measurements and the worth of the transient rod T-2. The axial power distribution in the flux wire for the M2-CAL experiment was determined and contrasted with the experiment. The model was then used to simulate the M2-CAL transient 2580 experiment based on the reported pre-transient and transient conditions. Several transient observables were calculated and compared to the experiment. The model shows good agreement with the experimental power traces, period, and average increase of power at the power ramp (time > 7.8 s). Inverse point kinetics analysis was performed during the period of the power ramp for the model and the experiment based on that, the temperature feedback component was isolated and contrasted with the experimental feedback. (authors)
How often do bright optical transients occur on the sky but go unreported? To constrain the bright end of the astronomical transient function, a systematic search for transients that become bright enough to be noticed by the unaided eye was conducted using the all-sky monitors of the Night Sky Live network. Two fisheye CONtinuous CAMeras operating over three years created a database that was searched for transients that appeared in time-contiguous CCD frames. Although a single candidate transient was found, the lack of more transients is used here to deduce upper limits to the general frequency of bright transients. To be detected, a transient must have increased by over three visual magnitudes to become brighter than visual magnitude 5.5 on the timescale of minutes to years. It is concluded that, on the average, fewer than 0.0040 (t {sub dur}/60 s) transients with duration t {sub dur} between minutes and hours, occur anywhere on the sky at any one time. For transients on the order of months to years, fewer than 160 (t {sub dur}/1 year) occur, while for transients on the order of years to millennia, fewer than 50 (t {sub dur}/1 year){sup 2} occur.
The transient reactor test facility (TREAT) is a graphite-based transient test reactor at the Idaho National Laboratory. TREAT started operation in 1959 and performed thousands of transient irradiations for the primary purpose of nuclear fuel safety research. TREAT operations were suspended in 1994 and then, several years later, resumed reactor operations in 2017 to support development of advanced nuclear fuels. During TREAT’s first era of operation the transient rod drive system and eventual Automatic Reactor Control System (ARCS) were upgraded and improved to create a transient reactor capable of unparalleled power shaping capabilities. TREAT’s first year of modern experiment work was performed in 2018 and saw the demonstration of new kinds of transients focused on modern experiment needs; especially focused on light water reactor (LWR) category transients including reactivity-initiated accidents (RIA) and loss of coolant accidents (LOCA). These transients were performed using a non-fueled neutronic mockup of a historical sodium loop which was not a perfect representation of future core configurations, but was adequate for demonstrating capabilities, successfully troubleshooting transient programming parameters, and calibrating nuclear models of the core. These physics tests were termed “transient prescription tests”. Later in 2018 the core was reconfigured to a modern fueled experiment arrangement and TREAT began performing irradiations on LWR rodlets where crucial fuel specimen nuclear heating data were obtained, and several supporting systems were commissioned. This successful effort gave way to additional fueled experiments which were performed throughout 2019.
In order to prepare for the TREAT reactor being taken off standby, the Gateway for Advanced Modeling and Simulation Lab has used a set of KENO models to simulate certain TREAT temperature- limited transients using the Transient Reactor excursion simulator (T-ReX) code, a hybrid deterministic-stochastic code. These transients are from the M8CAL experiment series, a set of experiments done to calibrate the reactor for the planned M8 series of fuel tests. Recently, the model has been updated in media definitions and geometry. Models were examined and calculations were performed to low uncertainty values to find the k{sub eff} and reactivity insertions. Alterations to modeled values of shutdown and initial transient rod insertion depth were made to create models which had experimental values of reactivity insertion, pre-transient k{sub eff}, or both. It was found that two of the altered media inputs, fuel and Zircaloy-3 cladding, had significant effect on the k{sub eff}. Surprisingly, the Zircaloy-3 composition had a larger effect on k{sub eff}. The reactivity insertions in this model's 2855, 2856 and 2857 temperature-limited transients were found to be above experimental values by a factor of 5.5% to 7%, and that pre-transient k{sub eff} was too high, at 1.002. It was found that increasing shutdown rod insertion by 2 to 2.5 cm decreased pre-transient k{sub eff} to 1.0, and that increasing shutdown rod insertion by 3 to 5 cm and decreasing initial transient rod insertion by 1 to 2 cm gave perfect pre-transient k{sub eff} and total reactivity insertion. (authors)
Transient testing involves placing nuclear fuel or material into the core of a nuclear reactor designed to operate at high power for a short time, and subjecting the nuclear fuel or material to short bursts of intense, high power radiation. After the experiment is completed, the fuel or material is analyzed to determine the effects of the radiation. The results are then used in fuel or material design and/or qualification. Transient testing is required for essentially all nuclear fuel design and qualification efforts to learn how nuclear fuel will respond during accidents involving transient overpower and/or under cooling events. For example, nuclear fuel may fragment when exposed to higher than normal power. This fragmentation can cause unacceptable performance. Transient testing is also needed to validate performance models for nuclear fuel and materials. These models, when validated, will dramatically shorten the development and qualification life cycle for nuclear fuels, supporting rapid development of low emissions, reliable power generation. In the past, transient testing was primarily done in facilities that no longer exist. The U.S. Department of Energy evaluated how to provide the required transient testing capability and, following completion of the National Environmental Policy Act process, they selected the Transient Reactor Test (TREAT) facility to resume transient testing. TREAT is located at Idaho National Laboratory (INL). The TREAT reactor was used from 1959 to 1994 to conduct more than 2,500 nuclear fuel transient tests, and was placed in standby in 1994. TREAT is capable of transients in excess of 19 GW. The paper describes the progress towards restart. The restart efforts have revealed that the plant fuel and equipment is acceptable for future operations. The safety basis development, procedures, and training are well under way. Experiment capability preparations are in progress. Reactor startup is anticipated no later than 2018. (author)