Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tomographic imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Galaxy blending effects in deep imaging cosmic shear probes of cosmology

ABSTRACT Upcoming deep imaging surveys such as the Vera C. Rubin Observatory Legacy Survey of Space and Time will be confronted with challenges that come with increased depth. One of the leading systematic errors in deep surveys is the blending of objects due to higher surface density in the more crowded images; a considerable fraction of the galaxies which we hope to use for cosmology analyses will overlap each other on the observed sky. In order to investigate these challenges, we emulate blending in a mock catalogue consisting of galaxies at a depth equivalent to 1.3 yr of the full 10-yr Rubin Observatory that includes effects due to weak lensing, ground-based seeing, and the uncertainties due to extraction of catalogues from imaging data. The emulated catalogue indicates that approximately 12 per cent of the observed galaxies are ‘unrecognized’ blends that contain two or more objects but are detected as one. Using the positions and shears of half a billion distant galaxies, we compute shear–shear correlation functions after selecting tomographic samples in terms of both spectroscopic and photometric redshift bins. We examine the sensitivity of the cosmological parameter estimation to unrecognized blending employing both jackknife and analytical Gaussian covariance estimators. An ∼0.025 decrease in the derived structure growth parameter S8 = σ8(Ωm/0.3)0.5 is seen due to unrecognized blending in both tomographies with a slight additional bias for the photo-z-based tomography. This bias is greater than the 2σ statistical error in measuring S8.

79 ASTRONOMY AND ASTROPHYSICS↗

Scanning structural mapping at the Life Science X-ray Scattering Beamline

This work describes the instrumentation and software for microbeam scattering and structural mapping at the Life Science X-ray Scattering (LiX) beamline at NSLS-II. Using a two-stage focusing scheme, an adjustable beam size between a few micrometres and a fraction of a millimetre is produced at the sample position. Scattering data at small and wide angles are collected simultaneously on multiple Pilatus detectors. A recent addition of an in-vacuum Pilatus 900k detector, with the detector modules arranged in a C-shaped configuration, has improved the azimuthal angle coverage in the wide-angle data. As an option, fluorescence data can be collected simultaneously. Fly scans have been implemented to minimize the time interval between scattering patterns and to avoid unnecessary radiation damage to the sample. For weakly scattering samples, an in-vacuum sample environment has been developed here to minimize background scattering. Data processing for these measurements is highly sample-specific. To establish a generalized data process workflow, first the data are reduced to reciprocal coordinates at the time of data collection. The users can then quantify features of their choosing from these intermediate data and construct structural maps. As examples, results from in-vacuum mapping of onion epidermal cell walls and 2D tomographic sectioning of an intact poplar stem are presented.

36 MATERIALS SCIENCE↗

Real-time streaming tomographic reconstruction with on-demand data capturing and 3D zooming to regions of interest

Complex dynamic tomographic experiments at brilliant X-ray light sources require real-time feedback on the sample changes with respect to environmental conditions, selecting representative regions of interest for high-resolution scanning, and on-demand data saving mechanisms for storing only relevant projections acquired by fast area detectors and reducing data volumes. Here the implementation details of a 3D real-time imaging monitoring instrument, with zooming to a volume of interest with easy-to-use visualization via ImageJ , a tool familiar to most beamline users, is presented. The instrument relies on optimized data flow between the detector and processing machines and is implemented on commodity computers. The instrument has been developed at beamline 2-BM of the Advanced Photon Source, where the automatic lens changing mechanism for zooming is implemented with an Optique Peter microscope. Performance tests demonstrate the ability to process more than 3 GB of projection data per second and generate real-time 3D zooming with different magnification. These new capabilities are essential for new APS Upgrade instruments such as the projection microscope under development at beamline 32-ID. The efficacy of the proposed instrument was demonstrated during an in situ tomographic experiment on ice and gas hydrate formation in porous samples.

3D zooming↗

Improving reproducibility in synchrotron tomography using implementation-adapted filters

For reconstructing large tomographic datasets fast, filtered backprojection-type or Fourier-based algorithms are still the method of choice, as they have been for decades. These robust and computationally efficient algorithms have been integrated in a broad range of software packages. The continuous mathematical formulas used for image reconstruction in such algorithms are unambiguous. However, variations in discretization and interpolation result in quantitative differences between reconstructed images, and corresponding segmentations, obtained from different software. This hinders reproducibility of experimental results, making it difficult to ensure that results and conclusions from experiments can be reproduced at different facilities or using different software. In this paper, a way to reduce such differences by optimizing the filter used in analytical algorithms is proposed. These filters can be computed using a wrapper routine around a black-box implementation of a reconstruction algorithm, and lead to quantitatively similar reconstructions. Use cases for this approach are demonstrated by computing implementation-adapted filters for several open-source implementations and applying them to simulated phantoms and real-world data acquired at the synchrotron. Our contribution to a reproducible reconstruction step forms a building block towards a fully reproducible synchrotron tomography data processing pipeline.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiscale X-ray phase contrast imaging of human cartilage for investigating osteoarthritis formation

The evolution of cartilage degeneration is still not fully understood, partly due to its thinness, low radio-opacity and therefore lack of adequately resolving imaging techniques. X-ray phase-contrast imaging (X-PCI) offers increased sensitivity with respect to standard radiography and CT allowing an enhanced visibility of adjoining, low density structures with an almost histological image resolution. This study examined the feasibility of X-PCI for high-resolution (sub-) micrometer analysis of different stages in tissue degeneration of human cartilage samples and compare it to histology and transmission electron microscopy. Ten 10%-formalin preserved healthy and moderately degenerated osteochondral samples, post-mortem extracted from human knee joints, were examined using four different X-PCI tomographic set-ups using synchrotron radiation the European Synchrotron Radiation Facility (France) and the Swiss Light Source (Switzerland). Volumetric datasets were acquired with voxel sizes between 0.7 × 0.7 × 0.7 and 0.1 × 0.1 × 0.1 µm 3 . Data were reconstructed by a filtered back-projection algorithm, post-processed by ImageJ, the WEKA machine learning pixel classification tool and VGStudio max. For correlation, osteochondral samples were processed for histology and transmission electron microscopy. X-PCI provides a three-dimensional visualization of healthy and moderately degenerated cartilage samples down to a (sub-)cellular level with good correlation to histologic and transmission electron microscopy images. X-PCI is able to resolve the three layers and the architectural organization of cartilage including changes in chondrocyte cell morphology, chondrocyte subgroup distribution and (re-)organization as well as its subtle matrix structures. X-PCI captures comprehensive cartilage tissue transformation in its environment and might serve as a tissue-preserving, staining-free and volumetric virtual histology tool for examining and chronicling cartilage behavior in basic research/laboratory experiments of cartilage disease evolution.

3D analysis↗

Characterization of Pinhole Collimators for High-Resolution Gamma Imaging of Irradiated Fuel

Post-irradiation examination (PIE) of nuclear fuels requires imaging tools capable of resolving isotopic and spatial features with high throughput. This project contributes to a proof-of-concept effort aimed at advancing gamma emission tomography (GET) by evaluating novel fine-aperture pinhole collimators. Two Rose’s metal collimators, 100 µm (20° acceptance angle) and 350 µm (30° acceptance angle), were prototyped and characterized for their effectiveness in transporting gamma rays through the pinhole aperture. To support data collection, a Python-based data acquisition system was developed to coordinate a rotation stage, linear stage, and CZT detector, reducing latency in high-rate gamma event logging to one second per acquisition. Queue-based file writing enabled seamless real-time data capture for count rates up to 35,000 counts per second (cps). List-mode parsing algorithms were implemented to differentiate single and simultaneous gamma interactions for future tomographic reconstruction. Detector response was evaluated in both spectroscopy and list mode acquisition methods across varying source distances to confirm absolute and collimator efficiencies. Preliminary efficiency figures suggest effective collimation of gamma-rays with energies below 700 keV, with ~4% residual intensity through the aperture for Cs-137. The impact of collimator geometry on image quality is currently being evaluated. This groundwork supports the ongoing development of a sub mm resolution cone-beam CT system for imaging fuel phantoms, an essential step toward improving GET efficiency and accelerating nuclear fuel qualification efforts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Accelerated deep self-supervised ptycho-laminography for three-dimensional nanoscale imaging of integrated circuits

Three-dimensional inspection of nanostructures such as integrated circuits is important for security and reliability assurance. Two scanning operations are required: ptychographic to recover the complex transmissivity of the specimen, and rotation of the specimen to acquire multiple projections covering the 3D spatial frequency domain. Two types of rotational scanning are possible: tomographic and laminographic. For flat, extended samples, for which the full 180° coverage is not possible, the latter is preferable because it provides better coverage of the 3D spatial frequency domain compared to limited-angle tomography. It is also because the amount of attenuation through the sample is approximately the same for all projections. However, both techniques are time consuming because of extensive acquisition and computation time. Here, we demonstrate the acceleration of ptycho-laminographic reconstruction of integrated circuits with 16 times fewer angular samples and 4.67 times faster computation by using a physics-regularized deep self-supervised learning architecture. We check the fidelity of our reconstruction against a densely sampled reconstruction that uses full scanning and no learning. As already reported elsewhere [ Opt. Express 28 , 12872 ( 2020 ) OPEXFF 1094-4087 10.1364/OE.379200 ], we observe improvement of reconstruction quality even over the densely sampled reconstruction, due to the ability of the self-supervised learning kernel to fill the missing cone.

47 OTHER INSTRUMENTATION↗

An automated fast neutron computed tomography instrument with on-line focusing for non-destructive evaluation

A fast neutron tomography imaging instrument has been designed, built, and tested at The Ohio State University 500 kW Research Reactor on a fast neutron beamline with a peak neutron flux ≈5.4 × 107 n·cm−2·s−1 at 1.6 MeV median neutron energy. The instrument and beamline are also configurable for thermal neutron imaging. The imaging apparatus is composed of a lens coupled, water-cooled Electron Multiplying Charge Coupled Device camera, a front-surface mirror, and a high light yield plastic Polyvinyl toluene scintillator. The instrument sits on a mobile cart. A total of 5 motion-control stages are built into the system for XYZ and rotational degrees of freedom for sample positioning; the fifth stage fine tunes the focal distance between the camera and the scintillator to achieve on-line focusing. A Python code with a user-friendly graphical user interface controls the fully automated image acquisition, not requiring user interaction, yet facilitating tracking of the image acquisition. A complete fast neutron computed tomography dataset with 360 projections requires less than 3 h, with 30 s per projection. On-line focusing is accomplished with a commercial, off-the-shelf, dielectrically actuated liquid lens. Finally, tomographic reconstructions are visualized using the Livermore Tomography Tools software package. The effective pixel size (width and height) is ≈0.1058 mm, yielding a minimum voxel size of 0.1058 × 0.1058 × 0.1058 mm3, and produces a spatial resolution of 231 μm when calculated from knife-edge measurements.

Bisbee, M. G. (ORCID:0000000313466697)↗

Megahertz Rate Optical Diagnostics of Explosively Generated Soot

Detonation of a solid explosive produces a turbulent and luminous post‐detonation fireball containing condensed carbon soot. Diagnostics of soot dynamics are needed for model validation and to interpret emission signals. Diffuse back‐illumination extinction imaging (DBI‐EI) and laser‐induced incandescence (LII) are two common optical diagnostics for flame soot. This work extends both to measure time‐resolved soot dynamics from a 12 mm HMX hemisphere. DBI‐EI measured line‐of‐sight optical extinction exceeds 99% in some regions. Results are tomographically inverted to obtain a signal proportional to the soot volume fraction. Pulse‐burst LII measures are presented at 1 MHz. For the first time, LII results are combined with DBI‐EI extinction measurements to quantify and correct for signal trapping. Following this, spatially and temporally resolved DBI‐EI and LII measures are shown to be in reasonable agreement. Finally, experimental results are compared against recently developed simulations. Quantitative differences in the soot mixing dynamics are resolved. These findings motivate future model improvements and demonstrate ongoing needs for diagnostic advancements for heavily sooting environments.

diffuse back-illumination extinction imaging↗

Simulation toolkit for digital material characterization of large image-based microstructures

In this paper, an efficient image-based simulation toolkit for material characterization is presented, which is scalable to work from personal computers to workstations. The effective thermal conductivity, elasticity, and permeability are evaluated employing a computational homogenization framework based on the Finite Element Method (FEM). Two complementary open-source packages are presented: one developed in Python, which can convert digital images into voxel meshes (pyTomoviewer); the other developed in Julia, that can run numerical simulations to compute effective material properties (chpack). Also, a CUDA C version of chpack is provided (chfem_gpu). They were designed to deal with large multi-phase models, so strategies were devised to minimize their memory footprint, while avoiding a high toll on execution time. The voxel-based approach significantly simplifies the FEM meshes and allows efficient matrix-free implementations. In that sense, to handle large linear systems of equations, the element-by-element (EBE) technique is adopted, in conjunction with a low-memory implementation of the Preconditioned Conjugate Gradient (PCG) method. Finally, the code was thoroughly tested on an artificial geometry made of a square array of cylinders, for which analytical solutions exist, as well as on a real micro-tomographic reconstruction of FiberForm TM , a carbon preform commonly used in thermal protection systems.

36 MATERIALS SCIENCE↗

Interfacial-Strain-Controlled Ferroelectricity in Self-Assembled BiFeO 3 Nanostructures

Self-assembled BiFeO 3 -CoFe 2 O 4 (BFO-CFO) vertically aligned nanocomposites are promising for logic, memory, and multiferroic applications, primarily due to the tunability enabled by strain engineering at the prodigious epitaxial vertical interfaces. However, local investigations directly revealing functional properties in the vicinity of such critical interfaces are often hampered by the size, geometry, microstructure, and concomitant experimental artifacts. Ferroelectric switching in the presence of lateral distributions of vertical strain thus remains relatively unexplored, with broader implications for all strain-engineered functional devices. Additionally, by implementing tomographic atomic force microscopy, 3D domain orientation mapping, and spatially-resolved ferroelectric switching movies, local tensile strain significantly impacts the ferroelectric switching, principally by retarding domain nucleation in the BFO nearest to the vertically epitaxial tensile-strained interfaces. The relaxed centers of the BFO pillars become preferred domain nucleation and growth sites for low biases, with up to an order of magnitude change in the edge:center switching ratio for high biases. The new, multi-dimensional imaging approach—and its corresponding insights especially for directly strained interface effects on local properties—thereby advances the fundamental understanding of polarization switching and provides design principles for optimizing functional response in confined nanoferroic systems.

36 MATERIALS SCIENCE↗

Status Report on Development of a Cask to Enable Pulsed Neutron Characterization of Irradiated Fuel

We present the design of a shielding cask that allows pulsed neutron characterization of irradiated fuel rodlets prior to their destructive examination in hot cells. The goal is to provide complementary and informative measurements that will inform subsequent hot cell PIE examinations by identifying typical and atypical regions with respect to microstructure, tomographic data, or isotope densities. Time-of-flight neutron diffraction has the potential to offer efficient, non-destructive and non-contact microstructural characterization of irradiated fuel pins with spatial resolution of 1 mm3 to 1 cm3 while for energy-resolved neutron imaging (and by extension tomography) a resolution of 100 μm was demonstrated. The potential results include crystallinity vs. amorphous volumes and microstructural information such as phase compositions and textures from the diffraction data as well as distances (e.g. pellet to cladding), cracks, and isotopic distributions of minor actinides, fission products as well as fission gas partial pressures e.g. in the plenum from energy resolved neutron imaging. The capability will identify regions of atypical behavior and provide cost effective bulk characterization of entire samples prior to destructive evaluation in hot cells. This effort is a collaboration between LANL, INL, ORNL, and UC Berkeley. A key facet of the initiative is the ability to cost effectively ship irradiated fuels from INL to the pulsed spallation neutron source at LANSCE. The irradiated fuel would be loaded in the custom designed cask (designated RaMHaM) at INL hot cells which then could be shipped in a BRR Type B shipment container between INL and LANL. No hot cell is required after the loading of the sample at INL in the pathway laid out in this report, greatly simplifying handling at LANL.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monte Carlo simulation methodology for characterizing the energy response function and resolving power of a digital Flat Panel Detector (FPD) assembly

The use of high-resolution, digital flat panel detectors (FPDs) makes quantitative assessments of radiographic and 3D tomographic representations feasible. However, the energy response function and spatial resolving power of the detector must be known. Here, we present a methodology for characterizing an FPD assembly using Monte Carlo simulations. The detector assembly modeled here was fielded in the 3-Ring Flash X-ray Imaging System designed and built at Lawrence Livermore National Laboratory (LLNL), which employs fifteen Carestream ® HPX-DR3543 FPDs enclosed in protective housings. Detailed Monte Carlo (MCNP6) simulations of an as-fielded detector assembly were performed to estimate its energy response function in terms of analog-to-digital unit (ADU) “counts” per pixel per incident x-ray as a function of energy up to ∼ 500 keV and its theoretical (idealized) resolving power. The practical resolving power of the FPD assembly in a realistic scenario was then estimated by simulating radiographic images of a variant of the United Kingdom (U.K.) “Kaleidoscope” resolution target.

Physics↗

3D radiated power analysis of JET SPI discharges using the Emis3D forward modeling tool

Abstract Precise values for radiated energy in tokamak disruption experiments are needed to validate disruption mitigation techniques for burning plasma tokamaks like ITER and SPARC. Control room analysis of radiated power ( P rad ) on JET assumes axisymmetry, since fitting 3D radiation structures with limited bolometry coverage is an under-determined problem. In mitigated disruptions, radiation is toroidally asymmetric and 3D, due to fast-growing 3D MHD modes and localized impurity sources. To address this problem, Emis3D adopts a physics motivated forward modeling (‘guess and check’) approach, comparing experimental bolometry data to synthetic data from user-defined radiation structures. Synthetic structures are observed with the Cherab modeling framework and a best fit chosen using a reduced χ 2 statistic. 2D tomographic inversion models are tested, as well as helical flux tubes and 3D MHD simulated structures from JOREK. Two nominally identical pure neon shattered pellet injection (SPI) mitigated discharges in JET are analyzed. 2D tomographic inversions with added toroidal freedom are the best fits in the thermal quench (TQ) and current quench (CQ). In the pre-TQ, 2D reconstructions are statistically the best fits, but are likely over-optimized and do not capture the 3D radiation structure seen in fast camera images. The next-best pre-TQ fits are helical structures that extend towards the high-field side, consistent with an impurity flow under the magnetic nozzle effect also observed in JOREK simulations. Whole-disruption radiated fractions of 0.98 + 0.03 / − 0.29 and 1.01 + 0.02 / − 0.17 are found, suggesting that the stored energy may have been fully mitigated by each SPI, although mitigation efficiencies well below ITER and SPARC requirements for high energy pulses are still within the large uncertainties. Emis3D is also used to validate JOREK SPI simulations, and confirms improvements in matching experiment from changes to impurity modeling. Time-dependent toroidal peaking factors are calculated and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Joint ptycho-tomography with deep generative priors

Abstract Joint ptycho-tomography is a powerful computational imaging framework to recover the refractive properties of a 3D object while relaxing the requirements for probe overlap that is common in conventional phase retrieval. We use an augmented Lagrangian scheme for formulating the constrained optimization problem and employ an alternating direction method of multipliers (ADMM) for the joint solution. ADMM allows the problem to be split into smaller and computationally more efficient subproblems: ptychographic phase retrieval, tomographic reconstruction, and regularization of the solution. We extend our ADMM framework with plug-and-play (PnP) denoisers by replacing the regularization subproblem with a general denoising operator based on machine learning. While the PnP framework enables integrating such learned priors as denoising operators, tuning of the denoiser prior remains challenging. To overcome this challenge, we propose a denoiser parameter to control the effect of the denoiser and to accelerate the solution. In our simulations, we demonstrate that our proposed framework with parameter tuning and learned priors generates high-quality reconstructions under limited and noisy measurement data.

97 MATHEMATICS AND COMPUTING↗

Hyper Suprime-Cam Year 3 results: Cosmology from cosmic shear power spectra

Here, we measure weak lensing cosmic shear power spectra from the 3-year galaxy shear catalog of the Hyper Suprime-Cam (HSC) Subaru Strategic Program imaging survey. The shear catalog covers 416 deg 2 of the northern sky, with a mean i-band seeing of 0.59 arcsec and an effective galaxy number density of 15 arcmin —2 within our adopted redshift range. With an i-band magnitude limit of 24.5 mag, and four tomographic redshift bins spanning 0.3 ≤ z ph ≤ 1.5 based on photometric redshifts, we obtain a high-significance measurement of the cosmic shear power spectra, with a signal-to-noise ratio of approximately 26.4 in the multipole range 300 < ℓ < 1800. The accuracy of our power spectrum measurement is tested against realistic mock shear catalogs, and we use these catalogs to get a reliable measurement of the covariance of the power spectrum measurements. We use a robust blinding procedure to avoid confirmation bias, and model various uncertainties and sources of bias in our analysis, including point spread function systematics, redshift distribution uncertainties, the intrinsic alignment of galaxies and the modeling of the matter power spectrum. For a flat Λ CDM model, we find S 8 ≡ σ 8 (Ω m /0.3) 0.5 = ${0.776}_{—0.033}^{+0.032}$, which is in excellent agreement with the constraints from the other HSC Year 3 cosmology analyses, as well as those from a number of other cosmic shear experiments. This result implies a ~2σ-level tension with the Planck 2018 cosmology. We study the effect that various systematic errors and modeling choices could have on this value, and find that they can shift the best-fit value of S 8 by no more than ~ 0.5σ, indicating that our result is robust to such systematics.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved Acquisition and Reconstruction for Wavelength-Resolved Neutron Tomography

Wavelength-resolved neutron tomography (WRNT) is an emerging technique for characterizing samples relevant to the materials sciences in 3D. WRNT studies can be carried out at beam lines in spallation neutron or reactor-based user facilities. Because of the limited availability of experimental time, potential imperfections in the neutron source, or constraints placed on the acquisition time by the type of sample, the data can be extremely noisy resulting in tomographic reconstructions with significant artifacts when standard reconstruction algorithms are used. Furthermore, making a full tomographic measurement even with a low signal-to-noise ratio can take several days, resulting in a long wait time before the user can receive feedback from the experiment when traditional acquisition protocols are used. In this paper, we propose an interlaced scanning technique and combine it with a model-based image reconstruction algorithm to produce high-quality WRNT reconstructions concurrent with the measurements being made. The interlaced scan is designed to acquire data so that successive measurements are more diverse in contrast to typical sequential scanning protocols. The model-based reconstruction algorithm combines a data-fidelity term with a regularization term to formulate the wavelength-resolved reconstruction as minimizing a high-dimensional cost-function. Using an experimental dataset of a magnetite sample acquired over a span of about two days, we demonstrate that our technique can produce high-quality reconstructions even during the experiment compared to traditional acquisition and reconstruction techniques. In summary, the combination of the proposed acquisition strategy with an advanced reconstruction algorithm provides a novel guideline for designing WRNT systems at user facilities.

47 OTHER INSTRUMENTATION↗

Characterization of a mock up nuclear waste package using energy resolved MeV neutron analysis

Reliable radiographic methods for characterizing nuclear waste packages non-destructively (without the need to open containers) have the potential to significantly contribute to safe handling and future disposal options, particularly for legacy waste of unknown content. Due to required shielding of waste containers and the need to characterize materials consisting of light elements, X-ray methods are not suitable. Here, energy-resolved MeV neutron radiography is demonstrated as a first-of-its-kind application for non-destructive and remote examination of mock up nuclear waste packages from a safe position using time-of-flight techniques enabled by a novel event-mode imaging detector system. Energy-resolved neutron transmission spectra were measured spatially, permitting the detection of analogue materials to actual nuclear waste such as water, melamine, and ion exchange resin within a 2.54 cm wall thickness steel pipe. The results demonstrate the capability to locate the materials through this wall thickness by radiography and tomographic reconstruction, revealing detailed 3D distributions and structural anomalies. The method effectively detects residual water in ion exchange resin, highlighting its sensitivity to moisture content, a crucial parameter for nuclear waste characterization. Monte Carlo simulations are in agreement with the experimental findings, providing a pathway to simulate waste forms more difficult to tackle experimentally. This work paves the way to apply sub-nanosecond intense MeV neutron sources, such as laser-driven neutron sources under development, to nuclear waste characterization.

36 MATERIALS SCIENCE↗