Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Nimbus-7 Earth radiation budget calibration history. Part 2: The Earth flux channels

Nine years (November 1978 to October 1987) of Nimbus-7 Earth radiation budget (ERB) products have shown that the global annual mean emitted longwave, absorbed shortwave, and net radiation were constant to within about + 0.5 W/sq m. Further, most of the small annual variations in the emitted longwave have been shown to be real. To obtain this measurement accuracy, the wide-field-of-view (WFOV) Earth-viewing channels 12 (0.2 to over 50 micrometers), 13 (0.2 to 3.8 micrometers), and 14 (0.7 to 2.8 micrometers) have been characterized in their satellite environment to account for signal variations not considered in the prelaunch calibration equations. Calibration adjustments have been derived for (1) extraterrestrial radiation incident on the detectors, (2) long-term degradation of the sensors, and (3) thermal perturbations within the ERB instrument. The first item is important in all the channels; the second, mainly in channels 13 and 14, and the third, only in channels 13 and 14. The Sun is used as a stable calibration source to monitor the long-term degradation of the various channels. Channel 12, which is reasonably stable to both thermal perturbations and sensor degradation, is used as a reference and calibration transfer agent for the drifting sensitivities of the filtered channels 13 and 14. Redundant calibration procedures were utilized. Laboratory studies complemented analyses of the satellite data. Two nearly independent models were derived to account for the thermal perturbations in channels 13 and 14. The global annual mean terrestrial shortwave and longwave signals proved stable enough to act as secondary calibration sources. Instantaneous measurements may still, at times, be in error by as much as a few Wm(exp -2), but the long-term averages are stable to within a fraction of a Wm(exp -2).

Kyle, H. Lee↗

Assessing Heterogeneity of Surface Water Temperature Following Stream Restoration and a High-Intensity Fire from Thermal Imagery

Thermal heterogeneity of rivers is essential to support freshwater biodiversity. Salmon behaviorally thermoregulate by moving from patches of warm water to cold water. When implementing river restoration projects, it is essential to monitor changes in temperature and thermal heterogeneity through time to assess the impacts to a river’s thermal regime. Lightweight sensors that record both thermal infrared (TIR) and multispectral data carried via unoccupied aircraft systems (UASs) present an opportunity to monitor temperature variations at high spatial (<0.5 m) and temporal resolution, facilitating the detection of the small patches of varying temperatures salmon require. Here, we present methods to classify and filter visible wetted area, including a novel procedure to measure canopy cover, and extract and correct radiant surface water temperature to evaluate changes in the variability of stream temperature pre- and post-restoration followed by a high-intensity fire in a section of the river corridor of the South Fork McKenzie River, Oregon. We used a simple linear model to correct the TIR data by imaging a water bath where the temperature increased from 9.5 to 33.4 °C. The resulting model reduced the mean absolute error from 1.62 to 0.35 °C. We applied this correction to TIR-measured temperatures of wetted cells classified using NDWI imagery acquired in the field. We found warmer conditions (+2.6 °C) after restoration (p < 0.001) and median absolute deviation for pre-restoration (0.30) to be less than both that of post-restoration (0.85) and post-fire (0.79) orthomosaics. In addition, there was statistically significant evidence to support the hypothesis of shifts in temperature distributions pre- and post-restoration (KS test 2009 vs. 2019, p < 0.001, D = 0.99; KS test 2019 vs. 2021, p < 0.001, D = 0.10). Moreover, we used a Generalized Additive Model (GAM) that included spatial and environmental predictors (i.e., canopy cover calculated from multispectral NDVI and photogrammetrically derived digital elevation model) to model TIR temperature from a transect along the main river channel. This model explained 89% of the deviance, and the predictor variables showed statistical significance. Collectively, our study underscored the potential of a multispectral/TIR sensor to assess thermal heterogeneity in large and complex river systems.

Barker, Matthew I. (ORCID:0000000252864930)↗

Design and Requirements Creep In A Build-To-Print Mission

Build-to-Print designs, or rebuilds of flight proven designs, are attractive to mission stakeholders, as they give the appearance of minimal engineering development cost, risk, and schedule. The reality is that seldom is a project an exact duplicate of a predecessor. Mission reclassification, improvements in hardware, and science objective changes can all serve as a source of requirements and design creep and have ramifications often not fully anticipated during initial proposals. The Thermal Infrared Sensor Instrument (TIRS) was a late addition to the LandSat-8 program to provide infrared imaging to measure evapotranspiration for water cycle management. To meet the launch requirements for LandSat-8, instrument design life requirements were relaxed, the sensor development expedited, and technology development was minimized. Consequently, TIRS was designed as a higher risk instrument, with less redundancy than an instrument critical to mission success. After the successful LandSat-8 launch in 2013 and instrument performance, a rebuild of the instrument for the next LandSat spacecraft was included in the baseline mission success criteria. This paper discusses the technical challenges encountered during the rebuild of the TIRS-2 (Thermal Infrared Sensor 2) instrument and the resultant impacts on the thermal system design.

TIRS-2 Thermal Design↗

Thermal Performance of the Hubble Space Telescope (HST) Solar Array-3 During the Disturbance Verification Test (DVT)

The Hubble Space Telescope (HST) is one of NASA's most productive astronomical observatories. Launched in 1990, the HST continues to gather scientific data to help scientists around the world discover amazing wonders of the universe. To maintain HST in the fore front of scientific discoveries, NASA has routinely conducted servicing missions to refurbish older equipment as well as to replace existing scientific instruments with better, more powerful instruments. In early 2002, NASA will conduct its fourth servicing mission to the HST. This servicing mission is named Servicing Mission 3B (SM3B). During SM3B, one of the major refurbishment efforts will be to install new rigid-panel solar arrays as a replacement for the existing flexible-foil solar arrays. This is necessary in order to increase electrical power availability for the new scientific instruments. Prior to installing the new solar arrays on HST, the HST project must be certain that the new solar arrays will not cause any performance degradations to the observatory. One of the major concerns is any disturbance that can cause pointing Loss of Lock (LOL) for the telescope. While in orbit, the solar-array temperature transitions quickly from sun to shadow. The resulting thermal expansion and contraction can cause a "mechanical disturbance" which may result in LOL. To better characterize this behavior, a test was conducted at the European Space Research and Technology Centre (ESTEC) in the Large Space Simulator (LSS) thermal-vacuum chamber. In this test, the Sun simulator was used to simulate on-orbit effects on the solar arrays. This paper summarizes the thermal performance of the Solar Array-3 (SA3) during the Disturbance Verification Test (DVT). The test was conducted between 26 October 2000 and 30 October 2000. Included in this paper are: (1) brief description of the SA3's components and its thermal design; (2) a summary of the on-orbit temperature predictions; (3) pretest thermal preparations; (4) a description of the chamber and thermal monitoring sensors; and (6) presentation of test thermal data results versus flight predictions.

Nguyen, Daniel H.↗

Yonkers Urban Development II: Leveraging NASA Earth Observations to Support Modeling Urban Cooling Interventions and Urban Heat Vulnerability in Yonkers, New York

The City of Yonkers, New York, located in Westchester County, is experiencing rising temperatures which are a growing threat to the health and safety of its residents. Furthermore, the risk of heat-related illnesses and mortality disproportionately affects neighborhoods in Yonkers historically subjected to race-based housing segregation. To better understand these inequities, Groundwork Hudson Valley and NASA DEVELOP collaborated for a second term to evaluate community-level heat vulnerability, landcover distribution, street-level thermal comfort, and modeled urban cooling interventions. This team applied 2019 5-year American Community Survey (ACS) data and social and biophysical heat vulnerability variables established by the New York State Department of Health (NYSDOH), along with land surface temperature (LST) data collected from Landsat 8 Thermal Infrared Sensor (TIRS), and ISS ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS) to identify communities in Yonkers in need of prioritized cooling intervention at the census tract level. Data from the Real-Time Mesoscale Analysis (RTMA) provided relevant meteorological data for the ENVI-met model to conduct street-level thermal observations and model tree canopy cooling interventions in the Yonkers neighborhoods of Kimball and Old 7th Ward. The project results will support the prioritization and equitable distribution of cooling infrastructure in identified neighborhoods. Additionally, Groundwork Hudson Valley will use the analyses as a heat literacy tool to improve advocacy efforts and inform both residents and officials about how investment in deliberate modification to tree canopy cover improves the city’s thermal environment and helps mitigate extreme heat.

Tamara Barbakova↗

Albuquerque Urban Development: Enhancing Urban Cooling Interventions by Modeling Urban Forestry through NASA Earth Observations in Albuquerque, New Mexico

The City of Albuquerque, New Mexico is experiencing increasing urban heat island(UHI) effects, which impact the health, safety, and comfort of the community. In partnership with the City of Albuquerque Department of Environmental Health, Department of Parks and Recreation, and Let’s Plant Albuquerque!, this project used satellite Earth observations from April 2016–August 2022 to model increases in tree canopy within the City of Albuquerque to help combat the urban heat island in the city’s warmer areas over the next decade. Using Landsat 8’s Thermal Infrared Sensor (TIRS) and the Ecosystem Spaceborne Thermal Radiometer Experiment on the International Space Station (ECOSTRESS), along with the Integrated Valuation of Ecosystem Services and Tradeoffs (InVEST) Urban Cooling and ENVI-Met models, the team modeled tree cover interventions and created land surface temperature maps. These outputs will help the city make data-driven decisions for their tree planting goal in a targeted approach.

Max Stewart↗

Dual and Multi-Spectral Band SLS Infrared Camera Systems

Based on the recent success of our strained-layer superlattice (SLS)-based infrared (IR) camera that performed Earth imaging from the International Space Station (ISS) in 2019 we have built, what we consider, to be the next generation multi-band SLS imaging system. The Compact Thermal Imager (CTI) was installed on the Robotic Refueling Mission 3 (RRM3) and attached to the exterior of the ISS. From this location we were able to capture 15 million images of a multitude of fires around the globe in 2019. This unexpected trove of data initiated quite a bit of scientific interest to further utilize this imaging capability but would include features to more precisely monitor terrestrial fires and other surface phenomena. To this end, we developed a technique to install specific bandpass filters directly onto the SLS detector hybrid assembly. Utilizing this technique we have built a CTI-2 camera system with two filters, 4 and 11µm, and have made a second detector assembly with six filter bands from 4-12µm. This second system will also be used to supplement Landsat remote imaging monitoring approximate land surface temperatures, monitor evapotranspiration, sea ice and glacier dynamics. The CTI-2 camera is based on a 1,024x1,024 (1kx1k) format SLS detector hybridized to a FLIR ISC0404 readout integrated circuit (ROIC). The six band SLS focal plane array is based on the 640x512 FLIR ISC 9803 ROIC. This camera system is based on the Landsat 8 and 9 Thermal IR Sensors (TIRS) instrument and one of its purposes is to perform ground truthing for the Landsat 8/9 data at higher spectral resolution. Both Landsat TIRS instruments are dual band thermal IR sensors centered on 11 and 12µm (each with about a 1µm bandpass). Both of our SLS systems utilize a Ricor K548 cryocooler. To streamline costs and development time we used commercial optics and both commercial and custom NASA electronic components. A primary feature of these camera systems is the incorporation of specific filters to collect fire data at ~3.9µm and thermal data at ~11µm. The CTI-2 instrument is designed for 37 m /pixel spatial resolution from 410km orbit (ISS orbit). In this paper, we will present the design and performance of the focal plane, optics, electronics and mechanical structure of the dual‑band CTI-2 and the focal plane performance of the six‑band focal plane.

Murzy Jhabvala↗

Low-Thermal-Conduction Links For Silicon Sensors

Simple method of texturing surface of silicon reduces thermal conductivities of links in silicon x-ray calorimeters and infrared bolometers. Gives links high density of phonon scattering sites reducing conduction of heat. Links made shorter and more robust. Used in making x-ray calorimeters and infrared bolometers. Applicable to any microelectronic device in which high degree of thermal isolation needed.

Mott, D. Brent↗

Laboratory-Based Thermal Shock Investigation of Heat Flux Sensors for the Mars 2020 Backshell

In 2012 during the entry, descent, and landing of the Mars Science Laboratory (MSL), the MSL Entry, Descent, and Landing Instrumentation (MEDLI) sensor suite was collecting in-flight heatshield pressure and temperature data. The data collected by the MEDLI instruments has since been used for reconstruction of vehicle aerodynamics, atmospheric conditions, aerothermal heating, and Thermal Protection System (TPS) performance as well as material response model validation and refinement. The Mars Entry, Descent, and Landing Instrumentation 2 (MEDLI2) sensor suite for the Mars 2020 heatshield and backshell is being designed to expand on the measurements and knowledge gained from MEDLI. Similar to MEDLI, MEDLI2 will measure the pressure and temperature of the heatshield. MEDLI2 will additionally measure the temperature, pressure, total heat flux, and radiative heat flux on the backshell.Since the backshell instrumentation is new to MEDLI2, Do No Harm (DNH) testing was conducted on instrumented backshell TPS (SLA-561V) panels. The panels consisted of four pressure port holes, one Mars Entry Atmospheric Data System (MEADS) pressure port plug, one MEDLI2 Integrated Sensor Plug (MISP) thermal plug, and one heat flux sensor. DNH testing was conducted to ensure the performance of the TPS was not degraded due to sensor integration and to characterize any TPS performance changes. The testing consisted of environmental testing— vibration, shock, thermal vacuum (TVAC) cycling— and bounding aerothermal (arc jet) testing. During arc jet testing, the heat flux sensors embedded in the SLA-561V panels exhibited an unexpected temporary reduction in the heat flux sensor temperature and response. After review of the test results, it was determined that this unexpected response was confined to the two heat flux sensors that experienced the greatest thermal shock condition. This condition consisted of a liquid nitrogen (LN2) bath that induced temperatures of approximately -190°C, and then a transition (thermal shock) to an arc jet test at a heat rate of approximately 21 W/cm2. Both heat flux sensors that were exposed to this thermal shock experienced a blister in the thermal coating during the arc jet test.Two heat flux sensor thermal shock test series were performed to investigate the cause of the blistering and subsequent energy release. In these tests, the heat flux sensor was first cold soaked in either a dry ice or LN2 bath to induce temperatures of approximately -78°C or -190°C, respectively. Then the sensors were thermally shocked using two propane torches with a heat rate of either approximately 8 W/cm2 or 21 W/cm2. The key findings indicated that there is a correlation between thermal shock and the blistering observed in the DNH test series, and that the cause appeared to be rooted in the heat flux sensor epoxy that encapsulates the sensor thermopile.Since the heat flux sensors are required to measure heat fluxes up to 15 W/cm2 during the Mars 2020 entry, a third test series was designed to determine if blistering is an issue at this maximum expected flight heat flux. Results from all three thermal shock test series and a discussion about whether or not blistering of the heat flux sensor thermal coating could be an issue for the Mars 2020 mission will be presented.

Miller, R. A.↗

Thermal Performance of Neutron Sensor Qualification Device

The neutron sensor qualification device was developed to provide a temperature-controlled environment for neutron sensors and dosimetry, enabling irradiation in a neutron field at the Armed Forces Radiobiology Research Institute (AFRRI) TRIGA reactor facility. The device, constructed from low-activation and low neutron cross-section materials, features a modular tube furnace design with three independently controlled heating zones for controlling axial temperature distribution. Laboratory testing validated the device's thermal performance, including uniform temperature distribution with less than 6°C variation across the central region, a steady-state operational temperature of 350°C achieved in approximately 3 hours, and a cooling time constant of 3.5 hours. External surface temperatures remained safe for handling, with the surrounding aluminum structure remaining at ambient conditions. The results confirm the device’s suitability for neutron sensor qualification experiments, with potential for future operation at higher temperatures and further optimization of performance.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Radiometric Calibration and Stability of the Landsat-8 Operational Land Imager (OLI)

Landsat-8 and its two Earth imaging sensors, the Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS) have been operating on-orbit for 2 1/2 years. The OLI radiometric calibration, which is monitored using on-board lamps, on-board solar diffusers, the moon and vicarious calibration techniques has been stable to within 1% over this period of time. The Coastal Aerosol band, band 1, shows the largest change at about 1% over the period; all other bands have shown no significant trend. OLI bands 1- 4 show small discontinuities in response (+0.1% to 0.2%) beginning about 7 months after launch and continuing for about 1 month associated with a power cycling of the instrument, though the origin of the recovery is unclear. To date these small changes have not been compensated for, but this will change with a reprocessing campaign that is currently scheduled for Fall 2015. The calibration parameter files (each typically covering a 3 month period) will be updated for these observed gain changes. A fitted response to an adjusted average of the lamps, solar and lunar results will represent the trend, sampled at the rate of one value per CPF.

radiometric stability↗

Radiometric Calibration and Stability of the Landsat-8 Operational Land Imager (OLI)

Landsat-8 and its two Earth imaging sensors, the Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS) have been operating on-orbit for 2 1/2 years. The OLI radiometric calibration, which is monitored using on-board lamps, on-board solar diffusers, the moon and vicarious calibration techniques has been stable to within 1% over this period of time. The Coastal Aerosol band, band 1, shows the largest change at about 1% over the period; all other bands have shown no significant trend. OLI bands 1- 4 show small discontinuities in response (+0.1% to 0.2%) beginning about 7 months after launch and continuing for about 1 month associated with a power cycling of the instrument, though the origin of the recovery is unclear. To date these small changes have not been compensated for, but this will change with a reprocessing campaign that is currently scheduled for Fall 2015. The calibration parameter files (each typically covering a 3 month period) will be updated for these observed gain changes. A fitted response to an adjusted average of the lamps, solar and lunar results will represent the trend, sampled at the rate of one value per CPF.

radiometry↗

Analytic Thermal Model of an Optical Fiber Based Gamma Thermometer and its Application in a University Research Reactor

This paper describes and validates, by comparison with numerical modeling results, an analytical model of thermal transport in an optical fiber based gamma thermometer (OFBGT) that is appropriate for use in university research reactors. The maximum temperature difference between the thermal mass and the outer sheath ( &#x0394;<!-- Δ --> T ) for the OFBGT design that we have considered is approximately 50 &#x2218;<!-- ° --> C , for the OFBGT in the Central Irradiation Facility of the Ohio State University Research Reactor (OSURR) with the reactor operating at full power (450 kW). The maximum value of &#x0394;<!-- Δ --> T that is predicted by the analytic model for the OFBGT design is smaller by approximately 1.1 °C than the value of &#x0394;<!-- Δ --> T which is predicted by the numerical model, for the same OFBGT design, but including all the details of the design. We have used the analytical model of thermal transport in an OFBGT to determine a normalized Modulation Transfer Function M T F &#x2032; ( k ) ) for the OFBGT. We conclude that MTF &#x2032;<!-- ' --> ( k OSU ) > 0.99 , where k OSU is the spatial frequency for the axial dependence of the reactor power distribution in the

47 OTHER INSTRUMENTATION↗

Performance of a flight qualified, thermoelectrically temperature controlled QCM sensor with power supply, thermal controller and signal processor

A thermoelectrically temperature controlled quartz crystal microbalance (QCM) system was developed for the measurement of ion thrustor generated mercury contamination on spacecraft. Meaningful flux rate measurements dictated an accurately held sensing crystal temperature despite spacecraft surface temperature variations from -35 C to +60 C over the flight temperature range. An electronic control unit was developed with magentic amplifier transformer secondary power supply, thermal control electronics, crystal temperature analog conditioning and a multiplexed 16 bit frequency encoder.

Wallace, D. A.↗

Landsat 9: Mission Status and Prelaunch Instrument Performance Characterization and Calibration

Landsat 9 is currently under development as a joint effort between NASA and the United States Geological Survey (USGS). Landsat 9 is essentially a rebuild of Landsat 8 and has the same two sensors, the Operational Land Imager (OLI) and the Thermal Imaging Sensor (TIRS). The OLI-2 on Landsat 9, is being built by Ball Aerospace and has completed its pre-launch characterization and calibration and is scheduled to be delivered in the summer of 2019. The TIRS-2, being built by Goddard Space Flight Center, is currently undergoing testing through Spring 2019 and also scheduled for summer 2019 delivery. Several improvements to the characterization of both instruments have been incorporated into the testing plan, including improved spectral and radiometric characterization. The instruments will then be integrated onto the spacecraft being built by Northrop Grumman Innovation Systems (NGIS). The mission is targeted to launch as early as December 2020 on an Atlas-5.

Markham, Brian↗