Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Using Satellite Surface Temperature Data to Monitor Urban Heat Island

Exposure to heat is a growing concern nationwide. Temperatures can be elevated in cities compared to surrounding rural areas, referred to as an “urban heat island” (UHI) effect, which is intensified during heat waves. The lack of dense networks of air temperature measurements results in few studies on urban heat. Now, a vast amount of high spatial and temporal satellite data on land surface temperature is available. We identified satellite datasets with the longest surface temperature records but different spatial and temporal resolutions: Landsat (1985-current, biweekly at 60 m and 100 m spatial resolution) and the Moderate Resolution Imaging Spectroradiometer (MODIS) data from the Terra and Aqua satellites (2000-current, daily at 1 km spatial resolution). We investigated how satellites with different spatial and temporal resolutions detect UHI effects differently. We hypothesized that 1) a dataset’s spatial resolution impacts the precision of detected UHIs spatially, since high spatial resolution Landsat data better captures spatial variability in temperature, and 2) daily surface temperature data can detect temporal patterns of UHIs and heatwave frequencies. We analyzed Landsat and MODIS satellite data in the Washington, D.C. and Baltimore region. We found that Landsat describes higher spatial variability of the UHI effect than MODIS data. However, MODIS data shows more consistent seasonal surface temperature patterns than Landsat when compared to in situ air temperature measurements. MODIS data was also able to consistently measure the frequency of heat waves. This study demonstrates the value of NASA satellite data for urban heat and climate change studies.

landsat↗

Optical Fiber Strain Instrumentation for High Temperature Aerospace Structural Monitoring

The objective of the program is the development and laboratory demonstration of sensors based on silica optical fibers for measurement of high temperature strain for aerospace materials evaluations. A complete fiber strain sensor system based on white-light interferometry was designed and implemented. An experiment set-up was constructed to permit testing of strain measurement up to 850 C. The strain is created by bending an alumina cantilever beam to which is the fiber sensor is attached. The strain calibration is provided by the application of known beam deflections. To ensure the high temperature operation capability of the sensor, gold-coated single-mode fiber is used. Moreover, a new method of sensor surface attachment which permits accurate sensor gage length determination is also developed. Excellent results were obtained at temperatures up to 800-850 C.

Wang, A.↗

Simultaneous Temperature/Pressure Monitoring in Compressible Flows using Hybrid fs/ps Pure-Rotational CARS

We demonstrate simultaneous monitoring of temperature and pressure using a hybrid femtosecond/picosecond pure-rotational CARS technique in a one-dimensional line-imaging configuration. The method employs two detection channels and two 60-ps-duration probe laser beams with independently adjustable time delays from the broadband 35-fs pump/Stokes pulse. Simultaneous temperature and pressure monitoring is demonstrated along the centerline of a canonical under expanded compressible air jet flow emanating from a choked, sonic nozzle. Temperature is measured almost independently of pressure by analyzing CARS spectra obtained with a probe pulse near zero time delay for nearly collision-free acquisition. Pressure is obtained from spectra acquired with long probe time delays to sample the impact of gas-phase collisions. The CARS measurements were obtained in both time-averaged and single-laser-shot mode with 67 μm spatial resolution along the jet axis along a nominally 6-mm line. The measurements span a temperature and pressure range of T= 70-300 K and P= 0.05-1.2atm.

Sean P Kearney↗

Enhanced Design of Radiation Tolerant High-Temperature Structural Health Monitoring Sensors

Acoustic emission sensors are vital in the nuclear industry for real-time structural health monitoring and early detection of material degradation. By capturing high-frequency stress waves emitted from defects like cracks, corrosion, or fatigue, acoustic emission sensors enable non-invasive monitoring of critical components such as reactor vessels, piping, and containment structures. This technology supports predictive maintenance, enhances safety, and ensures regulatory compliance by providing early warnings of potential failures. It is also instrumental in research, particularly in material testing reactors, where it is used to monitor the behavior of fuels and materials under irradiation, by allowing the detection of cracking or other acoustic signals in real time. This enables the evaluation of performance and accident behavior of advanced fuel concepts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Temperature controller for hyperthermia devices

Temperature controller monitors and controls temperature in local region of tumor. Medical grade thermocouples are inserted in or near tumor, controller pulse modulates radio frequency diathermy power source to maintain temperature within 0.2 C. System may be extended to control diathermy of more than one tumor or patient.

Couch, R. H.↗

Tire Temperature and Pressure Monitor

Wheel-mounted miniature transmitter would signal dangerous conditions to the driver or pilot. Monitor would include a sensor and a radio transmitter mounted so as not to imbalance the wheel. Sensor and batteries are enclosed in a plastic housing on the rim. Also has possibilities as a research tool for experiements on vehicle safety.

Macconochie, I. O.↗

Precise monitoring of global temperature trends from satellites

Passive microwave radiometry from satellites provides more precise atmospheric temperature information than that obtained from the relatively sparse distribution of thermometers over the earth's surface. Accurate global atmospheric temperature estimates are needed for detection of possible greenhouse warming, evaluation of computer models of climate change, and for understanding important factors in the climate system. Analysis of the first 10 years (1979 to 1988) of satellite measurements of lower atmospheric temperature changes reveals a monthly precision of 0.01 C, large temperature variability on time scales from weeks to several years, but no obvious trend for the 10-year period. The warmest years, in descending order, were 1987, 1988, 1983, and 1980. The years 1984, 1985, and 1986 were the coolest.

Spencer, Roy W.↗

Modulated FT- Raman Fiber-Optic Spectroscopy: A technique for Remotely Monitoring High-Temperature Reactions in Real-Time

A modification to a commercial FT-Raman spectrometer is presented for the elimination of thermal backgrounds in FT-Raman spectra. The modification involves the use of a mechanical chopper to modulate the CW laser, remote collection of the signal via fiber optics, and connection of a dual-phase digital signal processor lock-in amplifier between the detector and the spectrometer's collection electronics to demodulate and filter the optical signals. The resulting modulated FT-Raman fiber-optic spectrometer is capable of completely eliminating thermal backgrounds at temperatures exceeding 370 C. In addition, the signal/noise of generated Raman spectra is greater than for spectra collected with the conventional FT-Raman under identical conditions and incident laser power. This is true for both room-temperature and hot samples. The method allows collection of data using preexisting spectrometer software. The total cost of the modification (excluding fiber optics) is approximately $3000 and requires less than 2 h to implement. This is the first report of Fr-Raman spectra collected at temperatures in excess of 300 C in the absence of thermal backgrounds.

Cooper, John B.↗

Tracking the harmonic response of magnetically-soft sensors for wireless temperature, stress, and corrosive monitoring

This paper describes the application of magnetically-soft ribbon-like sensors for measurement of temperature and stress, as well as corrosive monitoring, based upon changes in the amplitudes of the higher-order harmonics generated by the sensors in response to a magnetic interrogation signal. The sensors operate independently of mass loading, and so can be placed or rigidly embedded inside nonmetallic, opaque structures such as concrete or plastic. The passive harmonic-based sensor is remotely monitored through a single coplanar interrogation and detection coil. Effects due to the relative location of the sensor are eliminated by tracking harmonic amplitude ratios, thereby, enabling wide area monitoring. The wireless, passive, mass loading independent nature of the described sensor platform makes it ideally suited for long-term structural monitoring applications, such as measurement of temperature and stress inside concrete structures. A theoretical model is presented to explain the origin and behavior of the higher-order harmonics in response to temperature and stress. c2002 Elsevier Science B.V. All rights reserved.

Non-NASA Center↗

Temperature Dependence of Electrical Resistance of Woven Melt-Infiltrated SiCf/SiC Ceramic Matrix Composites

Recent studies have successfully shown the use of electrical resistance (ER)measurements to monitor room temperature damage accumulation in SiC fiber reinforced SiC matrix composites (SiCf/SiC) Ceramic Matrix Composites (CMCs). In order to determine the feasibility of resistance monitoring at elevated temperatures, the present work investigates the temperature dependent electrical response of various MI (Melt Infiltrated)-CVI (Chemical Vapor Infiltrated) SiC/SiC composites containing Hi-Nicalon Type S, Tyranno ZMI and SA reinforcing fibers. Test were conducted using a commercially available isothermal testing apparatus as well as a novel, laser-based heating approach developed to more accurately simulate thermomechanical testing of CMCs. Secondly, a post-test inspection technique is demonstrated to show the effect of high-temperature exposure on electrical properties. Analysis was performed to determine the respective contribution of the fiber and matrix to the overall composite conductivity at elevated temperatures. It was concluded that because the silicon-rich matrix material dominates the electrical response at high temperature, ER monitoring would continue to be a feasible method for monitoring stress dependent matrix cracking of melt-infiltrated SiC/SiC composites under high temperature mechanical testing conditions. Finally, the effect of thermal gradients generated during localized heating of tensile coupons on overall electrical response of the composite is determined.

Ceramic Matrix Composites↗

Wireless Infrared Data Link

Infrared transmitter and receiver designed for wireless transmission of information on measured physical quantity (for example, temperature) from transducer device to remote-acquisition system. In transmitter, output of transducer amplified and shifted with respect to bias or reference level, then fed to voltage-to-frequency converter to control frequency of repetition of current pulses applied to infrared-light-emitting diode. In receiver, frequency of repetition of pulses converted back into voltage indicative of temperature or other measured quantity. Potential applications include logging data while drilling for oil, transmitting measurements from rotors in machines without using slip rings, remote monitoring of temperatures and pressures in hazardous locations, and remote continuous monitoring of temperatures and blood pressures in medical patients, who thus remain mobile.

Roth, Timothy E.↗

Cast Glance Near Infrared Imaging Observations of the Space Shuttle During Hypersonic Re-Entry

High resolution calibrated infrared imagery of the Space Shuttle was obtained during hypervelocity atmospheric entries of the STS-119, STS-125 and STS128 missions and has provided information on the distribution of surface temperature and the state of the airflow over the windward surface of the Orbiter during descent. This data collect was initiated by NASA s Hypersonic Thermodynamic Infrared Measurements (HYTHIRM) team and incorporated the use of air- and land-based optical assets to image the Shuttle during atmospheric re-entry. The HYTHIRM objective is to develop and implement a set of mission planning tools designed to establish confidence in the ability of an existing optical asset to reliably acquire, track and return global quantitative surface temperatures of the Shuttle during entry. On Space Shuttle Discovery s STS-119 mission, NASA flew a specially modified thermal protection system tile and instrumentation package to monitor heating effects from boundary layer transition during re-entry. On STS-119, the windward airflow on the port wing was deliberately disrupted by a four-inch wide and quarter-inch tall protuberance built into the modified tile. In coordination with this flight experiment, a US Navy NP-3D Orion aircraft was flown 28 nautical miles below Discovery and remotely monitored surface temperature of the Orbiter at Mach 8.4 using a long-range infrared optical package referred to as Cast Glance. Approximately two months later, the same Navy Cast Glance aircraft successfully monitored the surface temperatures of the Orbiter Atlantis traveling at approximately Mach 14.3 during its return from the successful Hubble repair mission. In contrast to Discovery, Atlantis was not part of the Boundary Layer Transition (BLT) flight experiment, thus the vehicle was not configured with a protuberance on the port wing. In September 2009, Cast Glance was again successful in capturing infrared imagery and monitoring the surface temperatures on Discovery s next flight, STS-128. Again, NASA flew a specially modified thermal protection system tile and instrumentation package to monitor heating effects from boundary layer transition during re-entry. During this mission, Cast Glance was able to image laminar and turbulent flow phenomenology optimizing data collection for Mach 14.7. The purpose of this paper is to describe key elements associated with STS-119/125/128 mission planning and execution from the perspective of the Cast Glance flight crew that obtained the imagery. The paper will emphasize a human element of experience, expertise and adaptability seamlessly coupled with Cast Glance system and sensor technology required to manually collect the required imagery. Specific topics will include a near infrared (NIR) camera upgrade that was implemented just prior to the missions, how pre-flight radiance modeling was utilized to optimize the IR sensor configuration, communications, the development of aircraft test support positions based upon Shuttle trajectory information, support to contingencies such as Shuttle one orbit wave-offs/west coast diversions and then the Cast Glance perspective during an actual Shuttle imaging mission.

Tack, Steve↗

Evaluation of Raman scattering as a sensor of temperature and molecular density

The performance of the Raman scattering technique for the remote monitoring of temperature and molecular number density in various wind tunnel and engine testing facilities has been experimentally evaluated. Temperature measurements were made by monitoring the pure rotational spectrum of nitrogen and the rotational branch separations of nu2 of CF4 for temperatures in the range 300 to 1000 K. These measurements yielded an average error of 2.6 and 7.6%, respectively, for temperature measurements at pressures near 1 atm. Molecular number density measurements with 20% error could be made at densities as low as 3.5 times 10 to the 22-nd power per cu m by monitoring the 6 to 8 rotational transition of nitrogen, 3.5 times 10 to the 23-rd power per cu m by monitoring the Q-branch of the fundamental vibrational transition of nitrogen, and 7 times 10 to the 22-nd power per cu m by monitoring the nu1 fundamental vibrational transition of CF4.

Bandy, A. R.↗