Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature logs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Pairing in a dry Fermi sea

In the traditional Bardeen–Cooper–Schrieffer theory of superconductivity, the amplitude for the propagation of a pair of electrons with momentum k and -k has a log singularity as the temperature decreases. This so-called Cooper instability arises from the presence of an electron Fermi sea. It means that an attractive interaction, no matter how weak, will eventually lead to a pairing instability. However, in the pseudogap regime of the cuprate superconductors, where parts of the Fermi surface are destroyed, this log singularity is suppressed, raising the question of how pairing occurs in the absence of a Fermi sea. In this paper, we report Hubbard model numerical results and the analysis of angular-resolved photoemission experiments on a cuprate superconductor. Finally, in contrast to the traditional theory, we find that in the pseudogap regime the pairing instability arises from an increase in the strength of the spin–fluctuation pairing interaction as the temperature decreases rather than the Cooper log instability.

36 MATERIALS SCIENCE↗

Direct sunlight facility for testing and research in HCPV

A facility for testing different components for HCPV application has been developed in the framework of 'Fotovoltaico ad Alta Efficienza' (FAE) project funded by the Sicilian Regional Authority (PO FESR Sicilia 2007/2013 4.1.1.1). The testing facility is equipped with an heliostat providing a wide solar beam inside the lab, an optical bench for mounting and aligning the HCPV components, electronic equipments to characterize the I-V curves of multijunction cells operated up to 2000 suns, a system to circulate a fluid in the heat sink at controlled temperature and flow-rate, a data logging system with sensors to measure temperatures in several locations and fluid pressures at the inlet and outlet of the heat sink, and a climatic chamber with large test volume to test assembled HCPV modules.

14 SOLAR ENERGY↗

THE TWO-PHASE, TWO-VELOCITY IONIZED ABSORBER IN THE SEYFERT 1 GALAXY NGC 5548

We present an analysis of X-ray high-quality grating spectra of the Seyfert 1 galaxy NGC 5548 using archival Chandra-High Energy Transmission Grating Spectrometer and Low Energy Transmission Grating Spectrometer observations for a total exposure time of 800 ks. The continuum emission (between 0.2 keV and 8 keV) is well represented by a power law (GAMMA = 1.6) plus a blackbody component (kT = 0.1 keV). We find that the well-known X-ray warm absorber (WA) in this source consists of two different outflow velocity systems. One absorbing system has a velocity of -1110 +- 150 km s{sup -1} and the other of -490 +- 150 km s{sup -1}. Recognizing the presence of these kinematically distinct components allows each system to be fitted independently, each with two absorption components with different ionization levels. The high-velocity system consists of two components, one with a temperature of 2.7 +- 0.6 x 10{sup 6} K, log U = 1.23, and another with a temperature of 5.8 +- 1.0 x 10{sup 5} K, log U = 0.67. The high-velocity, high-ionization component produces absorption by charge states Fe XXI-XXIV, while the high-velocity, low-ionization component produces absorption by Ne IX-X, Fe XVII-XX, and O VII-VIII. The low-velocity system also required two absorbing components, one with a temperature of 5.8 +- 0.8 x 10{sup 5} K, log U = 0.67, producing absorption by Ne IX-X, Fe XVII-XX, and O VII-VIII, and the other with a lower temperature of 3.5 +- 0.35 x 10{sup 4} K and a lower ionization of log U = -0.49, producing absorption by O VI-VII and the Fe VII-XII M-shell Unresolved Transitions Array. Once these components are considered, the data do not require any further absorbers. In particular, a model consisting of a continuous radial range of ionization structures (as suggested by a previous analysis) is not required. The two absorbing components in each velocity system are in pressure equilibrium with each other. This suggests that each velocity system consists of a multi-phase medium. This is the first time that different outflow velocity systems have been modeled independently in the X-ray band for this source. The kinematic components and column densities found from the X-rays are in agreement with the main kinematic components found in the UV absorber. This supports the idea that the UV and X-ray absorbing gas is part of the same phenomenon. NGC 5548 can now be seen to fit in a pattern established for other WAs: two or three discrete phases in pressure equilibrium. There are no remaining cases of a well-studied WA in which a model consisting of a multi-phase medium is not viable.

79 ASTRONOMY AND ASTROPHYSICS↗

USING A DIFFERENTIAL EMISSION MEASURE AND DENSITY MEASUREMENTS IN AN ACTIVE REGION CORE TO TEST A STEADY HEATING MODEL

The frequency of heating events in the corona is an important constraint on the coronal heating mechanisms. Observations indicate that the intensities and velocities measured in active region cores are effectively steady, suggesting that heating events occur rapidly enough to keep high-temperature active region loops close to equilibrium. In this paper, we couple observations of active region (AR) 10955 made with the X-Ray Telescope and the EUV Imaging Spectrometer on board Hinode to test a simple steady heating model. First we calculate the differential emission measure (DEM) of the apex region of the loops in the active region core. We find the DEM to be broad and peaked around 3 MK. We then determine the densities in the corresponding footpoint regions. Using potential field extrapolations to approximate the loop lengths and the density-sensitive line ratios to infer the magnitude of the heating, we build a steady heating model for the active region core and find that we can match the general properties of the observed DEM for the temperature range of 6.3 < log T < 6.7. This model, for the first time, accounts for the base pressure, loop length, and distribution of apex temperatures of the core loops. We find that the density-sensitive spectral line intensities and the bulk of the hot emission in the active region core are consistent with steady heating. We also find, however, that the steady heating model cannot address the emission observed at lower temperatures. This emission may be due to foreground or background structures, or may indicate that the heating in the core is more complicated. Different heating scenarios must be tested to determine if they have the same level of agreement.

79 ASTRONOMY AND ASTROPHYSICS↗

PHYSICAL CONDITIONS IN A YOUNG, UNREDDENED, LOW-METALLICITY GALAXY AT HIGH REDSHIFT

Increasingly large samples of galaxies are now being discovered at redshifts z {approx} 5-6 and higher. Many of these objects are inferred to be young, low in mass, and relatively unreddened, but detailed analysis of their high quality spectra will not be possible until the advent of future facilities. In this paper, we shed light on the physical conditions in a plausibly similar low-mass galaxy by presenting the analysis of the rest-frame optical and UV spectra of Q2343-BX418, an L* galaxy at z = 2.3 with a very low mass-to-light ratio and unusual properties: BX418 is young (<100 Myr), low mass (M {sub *} {approx} 10{sup 9} M{sub sun}), low in metallicity (Z {approx} 1/6 Z{sub sun}), and unreddened (E(B - V) {approx_equal} 0.02, UV continuum slope {beta} = -2.1). We infer a metallicity 12 + log(O/H) = 7.9 {+-} 0.2 from the rest-frame optical emission lines. We also determine the metallicity via the direct, electron temperature method, using the ratio O III] {lambda}{lambda}1661, 1666/[O III] {lambda}5007 to determine the electron temperature and finding 12 + log(O/H) = 7.8 {+-} 0.1. These measurements place BX418 among the most metal-poor galaxies observed in emission at high redshift. The rest-frame UV spectrum, which represents {approx}12 hr of integration with the Keck telescope, contains strong emission from Ly{alpha} (with rest-frame equivalent width 54 A), He II {lambda}1640 (both stellar and nebular), C III] {lambda}{lambda}1907, 1909 and O III] {lambda}{lambda}1661, 1666. The C IV/C III] ratio indicates that the source of ionization is unlikely to be an active galactic nucleus. Analysis of the He II, O III], and C III] line strengths indicates a very high ionization parameter log U {approx} -1, while Ly{alpha} and the interstellar absorption lines indicate that outflowing gas is highly ionized over a wide range of velocities. It remains to be determined how many of BX418's unique spectral features are due to its global properties, such as low metallicity and dust extinction, and how many are indicative of a short-lived phase in the early evolution of an otherwise normal star-forming galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Cryo-Temp Data Logger

Biological experiments on the ISS are frequently frozen at ultra-low temperatures on orbit prior to return to Earth for analysis. Recording temperatures during the freezing process, and subsequent handling to the point of post-flight processing, can provide important information of sample integrity to the scientist. The MadgeTech Cryo-Temp Data Logger has been modified for space flight applications by the Payload Development Team at Kennedy Space Center. This ultra-low temperature data logger is rated for temperatures from -86 C to +35 C with 0.1 C resolution and +/-1 C accuracy, but has been successfully tested at Kennedy Space Centers Cryogenic Lab down to -100 C. The logger provides date and time stamped temperature recordings and can be set with logging intervals from 5 seconds up to 30 minutes using the MadgeTech Data Logger Software. Data can be recorded, depending on logging interval, for greater than 90 days. The Cryo-Temp Data logger will first be flown on Space X-12 in the BRIC-Petri Dish Fixation Unit (PDFU) canister hardware, recording temperature data for a Space Life and Physical Sciences (SLPS) flight experiment. The modified Cryo-Temp Data Logger is small in size (Figure 1) and is the ideal temperature monitoring solution for any application involving independent temperature data logging.

Logger↗

Hot subdwarf stars observed in LAMOST DR1—atmospheric parameters from single-lined spectra

We present a catalog of 166 spectroscopically identified hot subdwarf stars from LAMOST DR1, 44 of which show the characteristics of cool companions in their optical spectra. Atmospheric parameters of 122 subdwarf stars with non-composite spectra were measured by fitting the profiles of hydrogen (H) and helium (He) lines with synthetic spectra from non-LTE model atmospheres. Most of the sdB stars scatter near the Extreme Horizontal Branch in the T{sub eff}–logg diagram and two well defined groups can be outlined. A clustering of He-enriched sdO stars appears near T{sub eff} = 45,000 K and log g = 5.8. The sdB population separates into several nearly parallel sequences in the T{sub eff}–He abundance diagram with clumps corresponding to those in the T{sub eff}–log g diagram. Over 38,000 K (sdO) stars show abundance extremes; they are either He-rich or He-deficient and we observe only a few stars in the abundance range −1<log y<0. With increasing temperature these extremes become less prominent and the He abundance approaches log y ∼ −0.5. A unique property of our sample is that it covers a large range in apparent magnitude and galactic latitude, therefore it contains a mix of stars from different populations and galactic environments. Our results are consistent with the findings of Hirsch and we conclude that He-rich and He-deficient sdB stars (log y < 1) probably originate from different populations. We also find that most sdO and sdB stars lie in a narrow strip in the plane of luminosity and helium abundance, which suggests that these atmospheric parameters are correlated.

79 ASTRONOMY AND ASTROPHYSICS↗

Flow behavior of ten iron-containing silicate compositions

The viscosity of ten iron-containing silicates has been measured over the temperature range 400 to 650 C. The compositions contain trace amounts up to 30 wt. pct. or 20 mole. pct. Fe3O4 from 10 to 20 wt. pct. or 10 to 20 mole. pct. Na2O and the remainder is SiO2. Samples were melted in air to form oxidized samples, in forming gas (95% N2-5% H2) to form mildly reduced samples, and in forming gas with carbon in the batch to form strongly reduced samples. In general, the viscosity decreased with increasing mole. pct. Na2O and decreasing mole. pct. SiO2 for a given temperature. In samples with increasing mole. pct. FeO(x) the difference in the viscosity between the oxidized sample and the reduced sample grew in magnitude at a given temperature. In all of the compositions, the log or viscosity, vs reciprocal-of-temperature relation shows curvature with an apparent activation energy between 90 and 100 kcal/mole.

Klein, L. C.↗

Calix[4]arene-bis(t-octylbenzo-18-crown-6) as an extraordinarily effective macrocyclic receptor for the univalent thallium cation

From extraction experiments and -activity measurements, the exchange extraction constant corresponding to the equilibrium Tl+ (aq) + 1 Cs+ (org) 1 Tl+ (org) + Cs+ (aq) taking place in the two-phase water phenyltrifluoromethyl sulfone (abbrev. FS 13) system (1 = calix[4]arene-bis(t-octylbenzo-18-crown-6); aq = aqueous phase, org = FS 13 phase) was evaluated as log Kex (Tl+, 1 Cs+) = 1.7 0.1. Further, the extraordinarily high stability constant of the 1 Tl+ complex in FS 13 saturated with water was calculated for a temperature of 25 C: log org(1 Tl+) = 13.1 0.2. Finally, by using quantum mechanical DFT calculations, the most probable structure of the cationic complex species 1 Tl+ was derived. In the resulting 1 Tl+ complex, the central cation Tl+ is bound by eight bond interactions to six oxygen atoms from the respective 18-crown-6 moiety and to two carbons of the corresponding two benzene rings of the parent receptor 1 via cation interaction.

calix[4]arene-bis(t-octylbenzo-18-crown-6)↗

NdPO 4 solubility and aqueous Neodymium speciation in supercritical fluids: An experimental study at 500–700 °C and 1.7 kbar

A key aspect in the formation of rare earth elements (REE) deposits is the role of REE transport as aqueous REE complexes in supercritical hydrothermal solutions, where the nature of the aqueous complex is controlled by solution composition, temperature and pressure. Despite chloride being considered as one of the most abundant transporting ligands in magmatic-hydrothermal fluids, experimental investigations on the stability of aqueous REE chloride complexes are scarce above 300 °C. In this study, synthetic NdPO 4 crystals were reacted with non-saline and saline (0, 0.05 and 0.5 mNaCl), acidic (0.01 mHCl) aqueous solutions in a series of solubility experiments conducted at 500–700 °C and 1.7 kbar, where the solubilities were determined using a stable Nd isotope ( 145 Nd isotope spike) dilution technique. NdPO 4 solubility ranges between 28 ppm and 10,858 ppm, where solubility increases with both temperature and salinity. At 500 °C, log mNdPO 4 increases from –3.93 to –1.60 and there is a strong correlation between NdPO 4 solubility and NaCl concentrations (slope of 1.2 ± 0.3), indicating stabilization of the Nd chloride aqueous complexes with a stoichiometry corresponding to NdCl 2+ . At 600 °C, this correlation is weaker (slope of 0.4, log mNdPO 4 increases from –2.63 to –1.88) indicating the stabilization of both Nd chloride and hydroxyl species controlling solubility. At 700 °C, NdPO 4 solubility is largely independent of NaCl concentration indicating that solubility is controlled by Nd hydroxyl complexes, where stoichiometry suggests the neutral Nd(OH) 3 0 species is dominant. The solubility product (Ksp) of NdPO4 is derived from experimental data with the relation: log K sp = -41.81 – 0.057T – 20987/T, with T temperature in Kelvin. Comparison of the measured Nd phosphate solubility to thermodynamic predictions using the available Helgeson-Kirkham-Flowers equation of state parameters for aqueous Nd complexes indicate that predictions are up to three orders of magnitude lower compared to experimental observations. This discrepancy is most pronounced in saline solutions, suggesting that thermodynamic properties of the REE chloride species in supercritical fluids require revision. Numerical simulations of fluid-rock interaction between acidic, saline fluids and a Strange Lake felsic mineral assemblage demonstrates that NdPO 4 solubility predictions from models are four to six orders of magnitude lower than those calculated based on empirical fits from experiments, which suggests that acidic, saline fluids may play an important role in mobilizing large amounts of light REE from 450 to 700 °C.

58 GEOSCIENCES↗

Chemical Tool Peer Review Summary.

Chemical tracers are commonly used to characterize fracture networks and to determine the connectivity between the injection and production wells. Currently, most tracer experiments involve injecting the tracer at the injection well, manually collecting liquid samples at the wellhead of the production well, and sending the samples off for laboratory analysis. While this method provides accurate tracer concentration data, it does not provide information regarding the location of the fractures conducting the tracer between wellbores. The goal of this project is to develop chemical sensors and design a prototype tool to help understand the fracture properties of a geothermal reservoir by monitoring tracer concentrations along the depth of the well. The sensors will be able to detect certain species of the ionic tracers (mainly iodide) and pH in-situ during the tracer experiment. The proposed high-temperature (HT) tool will house the chemical sensors as well as a standard logging sensor package of pressure, temperature, and flow sensors in order to provide additional information on the state of the geothermal reservoir. The sensors and the tool will be able to survive extended deployments at temperatures up to 225 °C and high pressures to provide real-time temporal and spatial feedback of tracer concentration. Data collected from this tool will allow for the real-time identification of the fractures conducting chemical tracers between wellbores along with the pH of the reservoir fluid at various depths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ship-based measurements of ice nuclei concentrations over the Arctic, Atlantic, Pacific and Southern oceans

Ambient concentrations of ice-forming particles measured during ship expeditions are collected and summarised with the aim of determining the spatial distribution and variability in ice nuclei in oceanic regions. The presented data from literature and previously unpublished data from over 23 months of ship-based measurements stretch from the Arctic to the Southern Ocean and include a circumnavigation of Antarctica. In comparison to continental observations, ship-based measurements of ambient ice nuclei show 1 to 2 orders of magnitude lower mean concentrations. To quantify the geographical variability in oceanic areas, the concentration range of potential ice nuclei in different climate zones is analysed by meridionally dividing the expedition tracks into tropical, temperate and polar climate zones. We find that concentrations of ice nuclei in these meridional zones follow temperature spectra with similar slopes but vary in absolute concentration. Typically, the frequency with which specific concentrations of ice nuclei are observed at a certain temperature follows a log-normal distribution. A consequence of the log-normal distribution is that the mean concentration is higher than the most frequently measured concentration. Finally, the potential contribution of ship exhaust to the measured ice nuclei concentration on board research vessels is analysed as function of temperature. We find a sharp onset of the influence at approximately -36 °C but none at warmer temperatures that could bias ship-based measurements.

54 ENVIRONMENTAL SCIENCES↗

Predicting temperature-dependent ultimate strengths of body-centered-cubic (BCC) high-entropy alloys

This paper presents a bilinear log model, for predicting temperature-dependent ultimate strength of high-entropy alloys (HEAs) based on 21 HEA compositions. We consider the break temperature, T break , introduced in the model, an important parameter for design of materials with attractive high-temperature properties, one warranting inclusion in alloy specifications. For reliable operation, the operating temperature of alloys may need to stay below T break . We introduce a technique of global optimization, one enabling concurrent optimization of model parameters over low-temperature and high-temperature regimes. Furthermore, we suggest a general framework for joint optimization of alloy properties, capable of accounting for physics-based dependencies, and show how a special case can be formulated to address the identification of HEAs offering attractive ultimate strength. We advocate for the selection of an optimization technique suitable for the problem at hand and the data available, and for properly accounting for the underlying sources of variations.

36 MATERIALS SCIENCE↗

EFFECT OF TEMPERATURE AND HUMIDITY ON FORMALDEHYDE EMISSIONS IN TEMPORARY HOUSING UNITS

The effect of temperature and humidity on formaldehyde emissions from samples collected from temporary housing units (THUs) was studied. The THUs were supplied by the U.S Federal Emergency Management Administration (FEMA) to families that lost their homes in Louisiana and Mississippi during the Hurricane Katrina and Rita disasters. Based on a previous study 1, 2, four of the composite wood surface materials that dominated contributions to indoor formaldehyde were selected to analyze the effects of temperature and humidity on the emission factors. Humidity equilibration experiments were carried out on two of the samples to determine how long the samples take to equilibrate with the surrounding environmental conditions. Small chamber experiments were then conducted to measure emission factors for the four surface materials at various temperature and humidity conditions. The samples were analyzed for formaldehyde via high performance liquid chromatography. The experiments showed that increases in temperature or humidity contributed to an increase in emission factors. A linear regression model was built using natural log of percentage relative humidity (RH) and inverse of temperature (in K) as predictor variables, and natural log of emission factors as the target variable. The coefficients of both inverse temperature and log relative humidity with log emission factor were found to be statistically significant for all the samples at the 95percent confidence level. This study should assist to retrospectively estimate indoor formaldehyde exposures of occupants of temporary housing units (THUs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Operational Characteristics of Two Commercially Available Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. A Life Enhancement Technologies, (LET) ice vest garment and a Steele, Inc. vest were used to cool the chest region of 11 male subjects (25 to 55 yr) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approximately 21 C) were tested for 60 min. with the cooling system operating at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. No significant differences were found in either the oral or ear temperature responses to the two vests. However, the rectal and mean skin temperatures at the end of the cooling period were both significantly lower (P less than 0.05), approximately 0.2 and 1.9 C, respectively for the LET vest than for the Steele garment. These data show that different vest configurations may produce different thermal responses in healthy male subjects which should be considered in the use of these cooling garments.

Ku, Yu-Tsuan E.↗

Operational Characteristics of Four Commercially Available Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 11 male and 10 female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.21 C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a URI Inc. Biolog ambulatory monitor. In general, the male and female subjects' rectal and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx.0.2 - 0.5 C, for both men and women wearing any of the four different garments. The corresponding car temperatures were significantly (P<0.05) decreased approx.0.2 - 0.3 C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and recovery periods. These results show that all vest configurations elicit a similar thermal response in both male and female subject groups. However, subject population variance was rather large and may have masked differences between the vests. One vest may prove more effective than another for a given individual, and experience is the only means of determining this.

Ku, Yu-Tsuan E.↗

Biomedical Application of Aerospace Personal Cooling Systems

Personal thermoregulatory systems which are used by astronauts to alleviate thermal stress during extravehicular activity have been applied to the therapeutic management of multiple sclerosis. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 10 male and female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.22C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. In general, the male and female subjects' oral and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx. 0.2 - 0.5C, for both men and women wearing any of the four different garments. The corresponding ear temperatures were significantly (P<0.05) decreased approx.0.2 - 0.4C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and recovery periods.

Ku, Yu-Tsuan E.↗

Physiological and Thermal Responses of MS Patients to Head and Vest Cooling: A Case Study

Personal cooling systems are used to alleviate symptoms of multiple sclerosis (MS) and to prevent increased core temperature during daily activities. The objective of this study was to determine the operating characteristics and the physiologic changes produced by short term application of the stationary thermal control system used by most clinical institutions. The Life Enhancement Tech (LET) Mark VII portable cooling system and a lightweight Head-vest active cooling garment were used to cool the head and chest regions of 4 male and 3 female MS patients (30 to 66 yrs. old) in this study. The subjects, seated in an upright position at normal room temperature (approx. 24 C), were tested for 60 min. with the liquid cooling garment (LCG) operated at 50 F. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures, heart rate, respiration, and an activity index were recorded continuously on a U.F.I., Inc., Biolog ambulatory monitor. All temperature responses showed extreme variation among subjects. The cold-sensitive subject's rectal temperature increased initially in response to cooling; the heat sensitive subject's rectal temperature decreased. After 40 min. of cooling and during recovery, all subjects'rectal temperatures decreased. Oral temperatures began to decrease after 30 min. of cooling. After 60 min. of cooling, temperature drops ranged from approx. 0.3 - 0.8 C. Oral temperatures continued to decrease during recovery (approx. 0.2 C). The car temperature of the heat sensitive subject was increased after cooling, other subjects exhibited an ear temperature decrease (0.0 - 0.5 C). These data indicate that head and vest cooling may be used to reduce the oral temperatures of MS patients by the approximate amount needed for symptomatic relief as shown by other researchers. The combination of a small subject population and a large subject variance does not permit us to draw statistical conclusions about the temperature response of MS patients. An individual's heat or cold sensitivity may influence their thermal response to cooling. This factor should be considered in the prescribed use of liquid cooling garments in the therapeutic management of MS.

Luna, Bernadette↗