Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “systematic errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

BEYONDPLANCK II. CMB mapmaking through Gibbs sampling

We present a Gibbs sampling solution to the mapmaking problem for cosmic microwave background (CMB) measurements that builds on existing destriping methodology. Gibbs sampling breaks the computationally heavy destriping problem into two separate steps: noise filtering and map binning. Considered as two separate steps, both are computationally much cheaper than solving the combined problem. This provides a huge performance benefit as compared to traditional methods and it allows us, for the first time, to bring the destriping baseline length to a single sample. Here, we applied the Gibbs procedure to simulated Planck 30 GHz data. We find that gaps in the time-ordered data are handled efficiently by filling them in with simulated noise as part of the Gibbs process. The Gibbs procedure yields a chain of map samples, from which we are able to compute the posterior mean as a best-estimate map. The variation in the chain provides information on the correlated residual noise, without the need to construct a full noise covariance matrix. However, if only a single maximum-likelihood frequency map estimate is required, we find that traditional conjugate gradient solvers converge much faster than a Gibbs sampler in terms of the total number of iterations. The conceptual advantages of the Gibbs sampling approach lies in statistically well-defined error propagation and systematic error correction. This methodology thus forms the conceptual basis for the mapmaking algorithm employed in the BEYONDPLANCK framework, which implements the first end-to-end Bayesian analysis pipeline for CMB observations.

79 ASTRONOMY AND ASTROPHYSICS↗

WAVELENGTH CALIBRATION OF THE VLT-UVES SPECTROGRAPH

We attempt to measure possible miscalibration of the wavelength scale of the VLT-UVES spectrograph. We take spectra of QSO HE0515-4414 through the UVES iodine cell which contains thousands of well-calibrated iodine lines and compare these lines to the wavelength scale from the standard thorium-argon pipeline calibration. Analyzing three exposures of this z = 1.71 QSO, we find two distinct types of calibration shifts needed to correct the Th/Ar wavelength scale. First, there is an overall average velocity shift of between 100 m s{sup -1} and 500 m s{sup -1} depending upon the exposure. Second, within a given exposure, we find intra-order velocity distortions of 100 m s{sup -1} up to more than 200 m s{sup -1}. These calibration errors are similar to, but smaller than, those found earlier in the Keck HIRES spectrometer. We discuss the possible origins of these two types of miscalibration. We also explore the implications of these calibration errors on the systematic error in measurements of {Delta}{alpha}/{alpha}, the change in the fine-structure constant derived from measurement of the relative redshifts of absorption lines in QSO absorption systems. The overall average, exposure-dependent shifts should be less relevant for fine-structure work, but the intra-order shifts have the potential to affect these results. Using either our measured calibration offsets or a Gaussian model with sigma of around 90 m s{sup -1}, Monte Carlo mock experiments find errors in {Delta}{alpha}/{alpha} of between 1 x 10{sup -6} N {sup -1/2}{sub sys} and 3 x 10{sup -6} N {sup -1/2}{sub sys}, where N{sub sys} is the number of systems used and the range is due to dependence on how many metallic absorption lines in each system are compared.

79 ASTRONOMY AND ASTROPHYSICS↗

Lattice study of N=2 Landau-Ginzburg model using a Nicolai map

It has been conjectured that the two-dimensional N=2 Wess-Zumino model with a quasihomogeneous superpotential provides the Landau-Ginzburg description of the N=2 superconformal minimal models. For the cubic superpotential W={lambda}{Phi}{sup 3}/3, it is expected that the Wess-Zumino model describes A{sub 2} model and the chiral superfield {Phi} shows the conformal weight (h,h)=(1/6,1/6) at the IR fixed point. We study this conjecture by a lattice simulation, extracting the weight from the finite volume scaling of the susceptibility of the scalar component in {Phi}. We adopt a lattice model with the overlap fermion, which possesses a Nicolai map and a discrete R-symmetry. We set a{lambda}=0.3 and generate the scalar field configurations by solving the Nicolai map on LxL lattices in the range L=18-32. To solve the map, we use the Newton-Raphson algorithm with various initial configurations. The result is 1-h-h=0.660{+-}0.011, which is consistent with the conjecture within the statistical error, while a systematic error is estimated as less than 0.5%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time-resolved dosimetry using a pinpoint ionization chamber as quality assurance for IMRT and VMAT

Purpose: To develop a method to verify the dose delivery in relation to the individual control points of intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) using an ionization chamber. In addition to more effective problem solving during patient-specific quality assurance (QA), the aim is to eventually map out the limitations in the treatment chain and enable a targeted improvement of the treatment technique in an efficient way. Methods: Pretreatment verification was carried out for 255 treatment plans that included a broad range of treatment indications in two departments using the equipment of different vendors. In-house developed software was used to enable calculation of the dose delivery for the individual beamlets in the treatment planning system (TPS), for data acquisition, and for analysis of the data. The observed deviations were related to various delivery and measurement parameters such as gantry angle, field size, and the position of the detector with respect to the field edge to distinguish between error sources. Results: The average deviation of the integral fraction dose during pretreatment verification of the planning target volume dose was −2.1% ± 2.2% (1 SD), −1.7% ± 1.7% (1 SD), and 0.0% ± 1.3% (1 SD) for IMRT at the Radboud University Medical Center (RUMC), VMAT (RUMC), and VMAT at the Wellington Blood and Cancer Centre, respectively. Verification of the dose to organs at risk gave very similar results but was generally subject to a larger measurement uncertainty due to the position of the detector at a high dose gradient. The observed deviations could be related to limitations of the TPS beam models, attenuation of the treatment couch, as well as measurement errors. The apparent systematic error of about −2% in the average deviation of the integral fraction dose in the RUMC results could be explained by the limitations of the TPS beam model in the calculation of the beam penumbra. Conclusions: This study showed that time-resolved dosimetry using an ionization chamber is feasible and can be largely automated which limits the required additional time compared to integrated dose measurements. It provides a unique QA method which enables identification and quantification of the contribution of various error sources during IMRT and VMAT delivery.

60 APPLIED LIFE SCIENCES↗

Finite-size effect on two-particle production in continuous and discrete spectrum

The formalism allowing one to account for the effect of a finite space-time extent of particle production region is given. Its applications to the lifetime measurement of hadronic atoms produced by a high-energy beam in a thin target, as well as to the femtoscopy techniques widely used to measure space-time characteristics of the production processes, are discussed. Particularly, it is found that the neglect of the finite-size effect on the pionium lifetime measurement in the experiment DIRAC at CERN could lead to the lifetime overestimation comparable with the 10% statistical error. The theoretical systematic errors arising in the calculation of the finite-size effect due to the neglect of non-equal emission times in the pair center-of-mass system, the space-time coherence and the residual charge are shown to be negligible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deterministic Modeling of the High Temperature Test Reactor

Idaho National Laboratory (INL) is tasked with the development of reactor physics analysis capability of the Next Generation Nuclear Power (NGNP) project. In order to examine INL’s current prismatic reactor deterministic analysis tools, the project is conducting a benchmark exercise based on modeling the High Temperature Test Reactor (HTTR). This exercise entails the development of a model for the initial criticality, a 19 column thin annular core, and the fully loaded core critical condition with 30 columns. Special emphasis is devoted to the annular core modeling, which shares more characteristics with the NGNP base design. The DRAGON code is used in this study because it offers significant ease and versatility in modeling prismatic designs. Despite some geometric limitations, the code performs quite well compared to other lattice physics codes. DRAGON can generate transport solutions via collision probability (CP), method of characteristics (MOC), and discrete ordinates (Sn). A fine group cross section library based on the SHEM 281 energy structure is used in the DRAGON calculations. HEXPEDITE is the hexagonal z full core solver used in this study and is based on the Green’s Function solution of the transverse integrated equations. In addition, two Monte Carlo (MC) based codes, MCNP5 and PSG2/SERPENT, provide benchmarking capability for the DRAGON and the nodal diffusion solver codes. The results from this study show a consistent bias of 2–3% for the core multiplication factor. This systematic error has also been observed in other HTTR benchmark efforts and is well documented in the literature. The ENDF/B VII graphite and U235 cross sections appear to be the main source of the error. The isothermal temperature coefficients calculated with the fully loaded core configuration agree well with other benchmark participants but are 40% higher than the experimental values. This discrepancy with the measurement stems from the fact that during the experiments the control rods were adjusted to maintain criticality, whereas in the model, the rod positions were fixed. In addition, this work includes a brief study of a cross section generation approach that seeks to decouple the domain in order to account for neighbor effects. This spectral interpenetration is a dominant effect in annular HTR physics. This analysis methodology should be further explored in order to reduce the error that is systematically propagated in the traditional generation of cross sections.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Bayesian Inference of High-density Nuclear Symmetry Energy from Radii of Canonical Neutron Stars

The radius R 1.4 of neutron stars (NSs) with a mass of 1.4 M ⊙ has been extracted consistently in many recent studies in the literature. Using representative R 1.4 data, we infer high-density nuclear symmetry energy E sym (ρ) and the associated nucleon specific energy E 0 (ρ) in symmetric nuclear matter (SNM) within a Bayesian statistical approach using an explicitly isospin-dependent parametric equation of state (EOS) for nucleonic matter. We found the following. (1) The available astrophysical data can already significantly improve our current knowledge about the EOS in the density range of ρ 0 - 2.5ρ 0 . In particular, the symmetry energy at twice the saturation density ρ 0 of nuclear matter is determined to be E sym (2ρ 0 )=${39.2}_{-8.2}^{+12.1}$ MeV at a 68% confidence level. (2) A precise measurement of R 1.4 alone with a 4% 1σ statistical error but no systematic error will not greatly improve the constraints on the EOS of dense neutron-rich nucleonic matter compared to what we extracted from using the available radius data. (3) The R 1.4 radius data and other general conditions, such as the observed NS maximum mass and causality condition, introduce strong correlations for the high-order EOS parameters. Consequently, the high-density behavior of E sym (ρ) inferred depends strongly on how the high-density SNM EOS E 0 (ρ) is parameterized, and vice versa. (4) Finally, the value of the observed maximum NS mass and whether it is used as a sharp cutoff for the minimum maximum mass or through a Gaussian distribution significantly affects the lower boundaries of both E 0 (ρ) and E sym (ρ) only at densities higher than about 2.5ρ 0 .

79 ASTRONOMY AND ASTROPHYSICS↗

Deterministic Modeling of the High Temperature Test Reactor with DRAGON-HEXPEDITE

The Idaho National Laboratory (INL) is tasked with the development of reactor physics analysis capability of the Next Generation Nuclear Power (NGNP) project. In order to examine the INL’s current prismatic reactor analysis tools, the project is conducting a benchmark exercise based on modeling the High Temperature Test Reactor (HTTR). This exercise entails the development of a model for the initial criticality, a 19 fuel column thin annular core, and the fully loaded core critical condition with 30 fuel columns. Special emphasis is devoted to physical phenomena and artifacts in HTTR that are similar to phenomena and artifacts in the NGNP base design. The DRAGON code is used in this study since it offers significant ease and versatility in modeling prismatic designs. DRAGON can generate transport solutions via Collision Probability (CP), Method of Characteristics (MOC) and Discrete Ordinates (Sn). A fine group cross-section library based on the SHEM 281 energy structure is used in the DRAGON calculations. The results from this study show reasonable agreement in the calculation of the core multiplication factor with the MC methods, but a consistent bias of 2-3% with the experimental values is obtained. This systematic error has also been observed in other HTTR benchmark efforts and is well documented in the literature. The ENDF/B VII graphite and U 235 cross sections appear to be the main source of the error. The isothermal temperature coefficients calculated with the fully loaded core configuration agree well with other benchmark participants but are 40% higher than the experimental values. This discrepancy with the measurement partially stems from the fact that during the experiments the control rods were adjusted to maintain criticality, whereas in the model, the rod positions were fixed. In addition, this work includes a brief study of a cross section generation approach that seeks to decouple the domain in order to account for neighbor effects. This spectral interpenetration is a dominant effect in annular HTR physics. This analysis methodology should be further explored in order to reduce the error that is systematically propagated in the traditional generation of cross sections.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Annealing a Follow-up Program: Improvement of the Dark Energy Figure of Merit for Optical Galaxy Cluster Surveys

The precision of cosmological parameters derived from galaxy cluster surveys is limited by uncertainty in relating observable signals to cluster mass. We demonstrate that a small mass-calibration follow-up program can significantly reduce this uncertainty and improve parameter constraints, particularly when the follow-up targets are judiciously chosen. To this end, we apply a simulated annealing algorithm to maximize the dark energy information at fixed observational cost, and find that optimal follow-up strategies can reduce the observational cost required to achieve a specified precision by up to an order of magnitude. Considering clusters selected from optical imaging in the Dark Energy Survey, we find that approximately 200 low-redshift X-ray clusters or massive Sunyaev-Zel'dovich clusters can improve the dark energy figure of merit by 50%, provided that the follow-up mass measurements involve no systematic error. In practice, the actual improvement depends on (1) the uncertainty in the systematic error in follow-up mass measurements, which needs to be controlled at the 5% level to avoid severe degradation of the results; and (2) the scatter in the optical richness-mass distribution, which needs to be made as tight as possible to improve the efficacy of follow-up observations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TU-H-CAMPUS-TeP2-04: Measurement of Stereotactic Output Factors with DNA Double-Strand Breaks

Purpose: Radiotherapy treatment is specified by radiation dose prescriptions, but biological DNA damage actually controls treatment effectiveness. It is impractical to directly measure dose in the clinic, so we measure quantities, such as collected charge, and calculate the relationship to dose. At small fields, such as those in stereotactic radiosurgery (SRS), charged-particle equilibrium (CPE) breaks down and the accuracy of the measurement for delivered dose decreases. By measuring DNA double-strand breaks (DSB) directly, we believe treatment accuracy could improve by providing a more meaningful measurement. Methods: A DNA dosimeter, consisting of magnetic streptavidin beads attached to 4 kilobase pair DNA strands labeled with biotin and fluorescein amidite (FAM) on opposing ends, was suspended in phosphate-buffered saline (PBS). Twenty µL samples were placed in plastic micro-capillary tubes inside a water tank setup and irradiated with 10 cm, 3 cm, 1.25 cm, 0.75 cm, and 0.5 cm radiation field sizes, where the three smallest sizes were cones. After irradiation, the dosimeters were mechanically separated into beads (intact DNA) and supernatant (broken DNA/FAM) using a magnet. The fluorescence was read and the probability of DSB was calculated. This was used to calculate the output factor for an SRS beam and compared to that measured using a diode detector. Results: The output factors relative to a 10 cm field were 0.89±0.07, 0.76±0.08, 0.59±0.04, and 0.78±0.12 for the field sizes of 3 cm, 1.25 cm, 0.75 cm, and 0.5 cm, respectively. Some of the diode measurements do not fall within these uncertainties. Conclusion: This was the first attempt to measure output factors in a water tank with the DNA dosimeter. Although differences compared to the diode were observed, the uncertainty analysis ignored systematic errors. For future work, we will repeat this experiment to quantify and correct systematic errors, such as those caused by positional alignment and sample contamination. This work was funded in part by CPRIT (RP140105).

60 APPLIED LIFE SCIENCES↗

Process-oriented evaluation using ARM observations to improve clouds and radiation in a global atmospheric model

The goal of the research is to improve understanding of cloud, radiation and precipitation processes and their representation in numerical models for weather and climate using observations from the ARM/ASR program. Global models need to represent all cloud types across different weather regimes from the tropics to the poles and ARM provides long-term observations at different geographical sites that cover these different regimes. Combined with satellite data to give a global context, the observations are used to evaluate the systematic errors in a global model for predictions of cloud, radiation and precipitation. The focus is on understanding the links to underlying physical processes to pinpoint the sources of error and improve the model representation of these processes. The research covers boundary layer cloud over the continental U.S., marine stratocumulus and shallow cumulus in the subtropics, mixed-phase clouds over the Arctic and Southern Ocean, and high-altitude cirrus ice clouds in the tropics. The model used is the operational global weather prediction system at the European Centre for Medium-range Weather Forecasts (ECMWF). The research has led to numerous developments, several of which have been implemented operationally leading to improvements in everyday forecasts. Many of the systematic errors are common across different modelling systems and the wider implications from the research for other weather and climate models are highlighted.

54 ENVIRONMENTAL SCIENCES↗

Detection of the pairwise kinematic Sunyaev-Zel'dovich effect with BOSS DR11 and the Atacama Cosmology Telescope

Here, we present a new measurement of the kinematic Sunyaev-Zel'dovich effect using data from the Atacama Cosmology Telescope (ACT) and the Baryon Oscillation Spectroscopic Survey (BOSS). Using 600 square degrees of overlapping sky area, we evaluate the mean pairwise baryon momentum associated with the positions of 50,000 bright galaxies in the BOSS DR11 Large Scale Structure catalog. A non-zero signal arises from the large-scale motions of halos containing the sample galaxies. The data fits an analytical signal model well, with the optical depth to microwave photon scattering as a free parameter determining the overall signal amplitude. We estimate the covariance matrix of the mean pairwise momentum as a function of galaxy separation, using microwave sky simulations, jackknife evaluation, and bootstrap estimates. The most conservative simulation-based errors give signal-to-noise estimates between 3.6 and 4.1 for varying galaxy luminosity cuts. We discuss how the other error determinations can lead to higher signal-to-noise values, and consider the impact of several possible systematic errors. Estimates of the optical depth from the average thermal Sunyaev-Zel'dovich signal at the sample galaxy positions are broadly consistent with those obtained from the mean pairwise momentum signal.

79 ASTRONOMY AND ASTROPHYSICS↗

A Point Kinetics Model for Estimating Neutron Multiplication of Bare Uranium Metal in Tagged Neutron Measurements

An extension of the point kinetics model is developed in this paper to describe the neutron multiplicity response of a bare uranium object under interrogation by an associated particle imaging deuterium-tritium (D-T) measurement system. This extended model is used to estimate the total neutron multiplication of the uranium. Both MCNPX-PoliMi simulations and data from active interrogation measurements of highly enriched and depleted uranium geometries are used to evaluate the potential of this method and to identify the sources of systematic error. The detection efficiency correction for measured coincidence response is identified as a large source of systematic error. If the detection process is not considered, results suggest that the method can estimate total multiplication to within 13% of the simulated value. Values for multiplicity constants in the point kinetics equations are sensitive to enrichment due to (n, xn) interactions by D-T neutrons and can introduce another significant source of systematic bias. This can theoretically be corrected if isotopic composition is known a priori. Finally, the spatial dependence of multiplication is also suspected of introducing further systematic bias for high multiplication uranium objects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modelling the BAO feature in bispectrum

We investigate how well a simple leading order perturbation theory model of the bispectrum can fit the baryon acoustic oscillation (BAO) feature in the measured bispectrum monopole of galaxies. Previous works showed that perturbative models of the galaxy bispectrum start failing at the wavenumbers of k ∼ 0.1 h Mpc −1 . We show that when the BAO feature in the bispectrum is separated, it can be successfully modelled up to much higher wavenumbers. We validate our modelling on GLAM simulations that were run with and without the BAO feature in the initial conditions. We also quantify the amount of systematic error due to BAO template being offset from the true cosmology. We find that the systematic errors do not exceed 0.3 per cent for reasonable deviations of up to 3 per cent from the true value of the sound horizon.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of Effective Optical Depth in the Lyα Forest from the BOSS DR12 Quasar Sample

We measure the effective optical depth in the Lyα forest using 40,035 quasar spectra from the Twelfth Data Release (DR12) of the Baryon Oscillation Spectroscopic Survey of Sloan Digital Sky Survey IV. A rigorous selection based on spectral index and the equivalent width of the C iv emission line is applied to choose seven uniform samples with minimal intrinsic variations across redshifts. Modeling the redshift evolution of the effective optical depth with a power law, ${\tau }_{\mathrm{eff}}={\tau }_{0}{(1+z)}^{\gamma },$ produces ${\tau }_{0}=(5.54\pm 0.64)\times {10}^{-3}$ and $\gamma =3.182\pm 0.074$. The 2.2% precision estimate on γ is dominated by systematic errors, likely arising from the bias and uncertainties in spectral index estimates. Even after incorporating the systematic errors, this work provides the most precise estimates of optical depth parameters to date. Finally, using the reconstructed Lyα forest continuum to directly measure the transmitted flux ratio as a function of redshift, we find deviations of less than 2.5% from the predictions from the global model and no convincing evidence for signal associated with He ii reionization.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectral Fidelity of Earth's Terrestrial and Aquatic Ecosystems

The Surface Biology and Geology (SBG) investigation will create global maps of spectral surface reflectance and emissivity at a cadence of 16 days or better, with coverage to address global questions about Earth's geology, cryosphere and ecosystems. The revolutionary potential poses a commensurate challenge: creating contiguous maps free from regional biases induced by atmosphere, observation geometry, or inversion error. This will require an accurate calibration with precise knowledge of each channel's spectral response. In this work, we quantify the impact of spectral calibration on SBG's aquatic and terrestrial ecosystem objectives. We find that contemporary algorithms for ecosystem trait retrieval demand more accurate spectral calibration than historical missions. Errors due to drift or spatial nonuniformity in the wavelength calibration that have previously been considered acceptable can cause systematic errors larger than the instrument noise and of the same order as the variability SBG aims to measure. Moreover, their impact on atmospheric correction can induce climate-dependent systematic errors that thwart comparisons between ecosystems. These results underscore the importance of spectral response accuracy in SBG mission design.

54 ENVIRONMENTAL SCIENCES↗