Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system planning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Planning Roadmap for DER Integration in India: Industry Best Practices and Resource Guide

Ensuring safe, reliable, cost-effective DER integration at scale requires holistic planning, broad stakeholder engagement, and should address key development areas such as standards adoption, equipment testing and certification, interoperability and cybersecurity, interconnection procedures, and advanced forecasting and DER management. Each of these areas currently represent significant challenges for utilities, regulators, OEMs, developers, and even consumers worldwide. India has already seen significant growth of DERs and has announced targets for substantial growth yet to come, with the potential for DERs to make up a non-negligible portion of the country's overall generation capacity. As such, it is of critical importance that Indian stakeholders consider the potential impacts of wide-spread adoption of DERs and take preemptive action related to the five development areas listed here, among others. India should consider strategies including the adoption of key DER standards related to interconnection, testing, and cybersecurity; enabling effective and secure communication channels for DER interoperability; testing and certifying DER equipment in accredited testing laboratories; building robust, streamlined interconnection procedures; and revamping legacy system planning structures to incorporate DERs in a holistic planning framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Duke Energy’s Integrated System and Operations Planning: A comparative analysis of integrated planning practices

Lawrence Berkeley National Laboratory and the National Renewable Energy Laboratory provided technical assistance to the South Carolina Office of Regulatory Staff to examine how Duke Energy’s Integrated System Operations Planning (ISOP) framework interacts with other electricity planning processes in South Carolina. While this report was prepared for the South Carolina ORS, the information contained herein may be useful to audiences in other states who are interested in IDP, including public utility commissions, state energy offices, other state agencies, utilities, and stakeholders. The report discusses how to access the ISOP process diagram created for the report, provides observations about Duke Energy’s ISOP from our interviews and review of publicly available materials; and assesses ISOP, based on best practices for integrated distribution planning.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Online Analytics for Remedy Support at DOE Environmental Management Sites

Environmental data is important for managing environmental restoration/waste site remediation, planning of monitoring efforts, addressing climate resilience, and engaging with stakeholders and regulators. A major challenge is how to manage the many different types and the large volume of environmental data in a way that allows practitioners and site managers to understand data implications and support decisions. The Suite Of Comprehensive Rapid Analysis Tools for Environmental Sites (SOCRATES, https://www.pnnl.gov/projects/socrates) is a web application that provides data access, visualization, and rapid analytics to help make sense of environmental data, support remedy decisions, and communicate information. Development of SOCRATES has been funded through the DOE Richland Operations Office (RL) to support communication and decision making for the Hanford Site, thus is only tied into Hanford environmental data. However, the capabilities of SOCRATES are more broadly applicable to DOE-EM sites engaged in environmental remediation and management. This report describes the work to develop mechanisms for bringing non-Hanford data into SOCRATES so that other DOE-EM sites could make use of the visualization and analysis capabilities to support communication and decision making related to managing environmental restoration/waste site remediation, optimization/exit strategies for pump-and-treat systems, planning monitoring efforts, addressing climate resilience, and/or engaging with stakeholders and regulators. The background, approach, data transfer formats, examples, and next steps for this new SOCRATES-EM software are described in this report.

54 ENVIRONMENTAL SCIENCES↗

Enhanced Frequency Support Scheme of Generic Inverter-Based Resource Models for Renewable-Dominated Power Grids

The frequency response of SG-dominated power grids is predictable ahead of an occurrence of a frequency event because the frequency response of SGs is consistent, and it can be inferred from the swing equation [1]. However, increasing the portion of IBRs in an SG-dominated power grid might make the characteristics of the conventional power grids no longer valid because this changing resource mix affects grid dynamics and controls [2]. Thus, maintaining these characteristics greatly benefits the control and operation of the power grids with high penetration of IBRs. To maintain these characteristics in IBR-dominated power grids, IBRs should have frequency response capability similar to that of an SG. The WECC modeling validation subcommittee has developed generic IBR models for large system planning [3]-[5]. These models can represent various vendors' dynamic behavior for WTG, PV, and ESS [5]. The current generic IBR models approved by WECC can provide frequency response only from droop control loops in REPC models [6], [7]. The contribution of the loops is proportional to the frequency deviation from the nominal frequency. Thus, it presents an insufficient contribution to arrest frequency variation compared to the frequency response of SGs because it allows a high ROCOF in the early stage of frequency events. This shortfall will become greater as the PL of IBRs increases in power grids. Controller enhancement for the generic IBR models is required to secure the frequency stability under high PL of IBRs as in the SG-dominated power grids. This paper proposes a control extension for the generic IBR models to enhance the frequency support capabilities and discusses the classification of frequency support for the different types of IBR considering their operating constraints. An inertial control scheme is implemented in the REPC and REEC models of the generic IBR models to achieve these objectives. The inertial control scheme includes the following stages: Control area data acquisition, inertia time constant estimation, IBR-related constraint check, IBR contribution determination, and inertial response provision. In the scheme, a REPC acquires control area data from a system operator and estimates a total inertia time constant for the control area the applicable IBR power plant belongs. Then, the estimated inertial time constant is transferred to each IBR controller—REEC—within the power plant. Each REEC checks the availability of applicable IBR for inertial response participation. If the IBR is available, the REEC amplifies the estimated inertial time constant to utilize it for inertial response provision. In this way, the proposed inertial response scheme extends the functionality of the generic IBR models to provide SG-like frequency response within their constraints. Various scenarios considering different IBR types, IBR penetration levels, and frequency control schemes were simulated and compared in an IEEE 39-bus system using PSCAD simulator to verify the effectiveness of the proposed scheme.

Kim, Jinho↗

Overview of the physics basis for the ARC fusion power plant

Commonwealth Fusion Systems plans to build ARC as the first fusion power plant at a site in Chesterfield County, Virginia, USA by the early 2030s. We present an overview of analysis comprising the physics basis of the ARC V3A design, a high-magnetic-field tokamak with 𝐵 0 =11.4 T, 𝐼 𝑝 =12.0 MA, 𝑅 0 =4.62 m, 𝑎 =1.18 m. ARC V3A is designed to produce 𝑃 𝑓⁡𝑢⁢𝑠 ≈1.13 GW DT fusion power and deliver ⩾400 MW net electric power to the grid. This overview includes quantitative analysis of fundamental issues for design of and operational plasma scenarios for a tokamak power plant, and lays out the design targets and strategic choices for ARC, including empirical fusion performance projections, assessment of H-mode access, ion cyclotron resonance heating simulations, alpha particle physics and time-dependent full-pulse simulations. This is complemented by topical papers on fusion performance and transport, disruption physics, boundary physics and magnetohydrodynamic stability. Critically, these studies identify key model uncertainties and physics risks to be retired through SPARC operation. Due to the modular nature of ARC, early results from SPARC can be incorporated into the design of the first ARC as well as subsequent replacements of the ARC vacuum vessel.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interactions of Wind Energy Project Siting, Wind Resource Potential, and the Evolution of the U.S. Power System

The interactions of wind energy project siting, resource potential, and power system evolution are critical to understand given interest in high renewable energy systems, particularly as wind costs have fallen and grid operators implement solutions to manage variable generation. This study applies an integrative approach that combines spatially-explicit resource potential analysis with high spatial resolution U.S. electricity system modeling. Multiple wind supply curves, representing variations in siting regimes that account for interactions with built infrastructure, regulatory, physical, and social land use factors, are evaluated to determine how siting could influence prospective wind development. Different siting regimes lead to variations in future wind capacity, with the greatest impacts observed under scenarios with high demand for clean energy. With the tightest emissions limit modeled, 2050 onshore wind capacity varied by +7% (49 GW) in the least-restrictive siting regime to a decrease of 37% (270 GW) under the most-constrained case. More-stringent siting restrictions lead to higher electricity prices and emissions that should be weighed with local impacts. Under restrictive siting regimes, wind deployment is also sensitive to transmission availability and wind plant design. Overall, the findings highlight the importance of local land use considerations in regional and national power system planning.

17 WIND ENERGY↗

Analyzing impact of $\mathrm{DER}$ on $\mathrm{FIDVR}$ - comparison of $\mathrm{EMT}$ simulation of a combined transmission and distribution grid with aggregated positive sequence models

The increase in percentage of distributed energy resources (DERs) brings in a degree of uncertainty in bulk power system planning and operations. Further, the presence of 1 - φ induction motors introduces the possibility of motor stalling and fault induced delayed voltage recovery (FIDVR). With newer versions of IEEE Std 1547™ there can be the opportunity to obtain dynamic voltage support from DERs. In this report, the impact of DERs providing dynamic voltage on the dynamic behavior of 1 - φ induction motors is examined in detail along with an exploration of the need for simulation platforms that go beyond positive sequence. The studies discussed here are carried out both in detailed electromagnetic time domain and in positive sequence domain for comparison.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Regional inertia dynamics of U.S. interconnections: An event-based measurement approach

Power grid inertia plays a vital role in frequency stability following large disturbances, yet its distribution across the U.S. grid is highly uneven. While interconnection-wide inertia benchmarks are useful, they can mask regional variability driven by resource mix, network coupling, and geographic separation. This paper extends event-driven inertia estimation to the regional scale using field measurements from the Frequency Monitoring Network (FNET/GridEye). Starting from balancing authority and independent system operator footprints, candidate regions are refined using a composite coherency score that combines frequency-trajectory shape similarity, timing spread, and lead/lag behavior to ensure dynamic consistency. A filtered sliding difference method (FSDM) is then used to construct regional frequency trajectories, detect disturbance onset, and compute robust regional rate-of-change of frequency (RoCoF). Regional, local, and interconnection inertia are estimated by combining RoCoF with event power imbalance, and additional indicators (regional-to-system inertia ratio and inertial-support arrival time) quantify regional-to-interconnection coupling and relative regional contributions. The method is demonstrated on eleven regions across the Eastern Interconnection (EI) and the Western Electricity Coordinating Council (WECC), with the Electric Reliability Council of Texas (ERCOT) used for validation. In ERCOT, estimates compared against energy management system (EMS) values achieve a mean absolute percentage error of 17.94%. WECC exhibits consistently shorter inertial-support arrival times (0.15–0.3 s) than EI (0.7–1.1 s), highlighting contrasting coupling and disturbance-propagation behavior. Overall, the results reveal pronounced spatial heterogeneity in inertia and coupling, underscoring the value of regional monitoring for both operational decision-making and long-term system planning.

Disturbance events↗

Environmental trade-offs of direct air capture technologies in climate change mitigation toward 2100

Abstract Direct air capture (DAC) is critical for achieving stringent climate targets, yet the environmental implications of its large-scale deployment have not been evaluated in this context. Performing a prospective life cycle assessment for two promising technologies in a series of climate change mitigation scenarios, we find that electricity sector decarbonization and DAC technology improvements are both indispensable to avoid environmental problem-shifting. Decarbonizing the electricity sector improves the sequestration efficiency, but also increases the terrestrial ecotoxicity and metal depletion levels per tonne of CO 2 sequestered via DAC. These increases can be reduced by improvements in DAC material and energy use efficiencies. DAC exhibits regional environmental impact variations, highlighting the importance of smart siting related to energy system planning and integration. DAC deployment aids the achievement of long-term climate targets, its environmental and climate performance however depend on sectoral mitigation actions, and thus should not suggest a relaxation of sectoral decarbonization targets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Land-use and atmospheric shifts jointly amplify U.S. drought-driven crop losses

Agricultural drought (AD) poses a major threat to food security, yet its future risk remains uncertain under co-evolving atmospheric conditions and land-use trajectories. Using an integrated, multi-sector modeling framework, we project AD risks for major crops across the contiguous United States (CONUS) through 2055 under a range of plausible futures that capture thermodynamic changes and land-use and land-cover change (LULCC) trajectories. Model projections reveal that drought-driven crop production losses increase sharply by nearly 60% for corn, 250% for wheat, and 135% for soybean relative to historical levels. The primary drivers of these increases, which include atmospheric shifts and LULCC, vary by region and crop type. LULCC acting as an important risk amplifier in regions experiencing cropland expansion into drought-prone regions, such as the Great Plains and northwestern U.S. Wheat exhibits the largest projected loss increases, a result that remains robust across scenarios. These findings highlight that interactions between atmospheric conditions and land-use trajectories shape future agricultural drought risk and should be jointly considered to support effective adaptation and food-system planning.

Yao, Lili↗

Cosmic Muon Veto for the mini-ICAL detector at IICHEP, Madurai

A 51-kiloton magnetised Iron Calorimeter (ICAL) detector, using Resistive Plate Chambers (RPCs) as active detector elements, aims to study atmospheric neutrinos. A prototype - 1/600 of the weight of ICAL, called mini-ICAL was installed in the INO transit campus at Madurai. A modest proof-of-principle cosmic muon veto detector of about 1 m × 1 m × 0.3 m dimensions was setup a few years ago, using scintillator paddles. The measured cosmic muon veto efficiency of 99.98% and simulation studies of muon-induced background events in the ICAL detector surrounded by an efficient veto detector were promising. This led to the idea of constructing a bigger cosmic muon veto around the mini-ICAL detector. Details of the design and construction of the detector including the electronics, trigger and DAQ systems planned will be briefly presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

River systems under peaked stress

The change in the global energy production mix towards variable renewable energy sources requires efficient utilization of regulated rivers to optimise hydropower operations meet the needs of a changing energy market. However, the flexible operation of hydropower plants causes non-natural, sub-daily fluctuating flows in the receiving water bodies, often referred to as ‘hydropeaking’. Drastic changes in sub-daily flow regimes undermine attempts to improve river system health. Environmental decision makers, including permitting authorities and river basin managers facing the intense and increasing pressure on river environments, should consider ecosystem services and biodiversity issues more thoroughly. The need for research innovations in hydropeaking operation design to fulfil both the water and energy security responsibilities of hydropower is highlighted. Our paper outlines optimized hydropeaking design as a future research direction to help researchers, managers, and decision-makers prioritize actions that could enable better integration of river science and energy system planning. The goal of this is to find a balanced hydropower operation strategy.

54 ENVIRONMENTAL SCIENCES↗

Behavior of Multiple PV Plants in Future Power Grids During Events

As the integration of multiple photovoltaic (PV) plants into power grids grows, the dynamic response of each plant and their interactions during transient events demands a deeper understanding. In this paper, the dynamic behavior of multiple PV plants connected to future power grids is comprehensively explored using site-specific high-fidelity electromagnetic transient (EMT) PV plant models and generic high-fidelity EMT PV plant models. This research demonstrates the need to employ multiple high-fidelity EMT PV plant models to understand the intricate interactions between multiple PV plants during grid events. These models, developed in Fortran within the PSCAD environment, encompass a range of operational scenarios and plant configurations, offering invaluable insights crucial for future system planning with multiple PV plants to enhance grid stability.

Marthi, Phani Ratna Vanamali [ORNL] (ORCID:0000000↗

Impact Analysis of Future Electric Vehicles Using Model of Real Distribution Feeders

Globally, the number of electric vehicles (EVs) continues to increase. This on-going trend poses challenges for power distribution systems. The inclusion of electric vehicle supply equipment (EVSE) should be compatible with a changing energy system, whose structure is becoming increasingly distributed. The impact of future EVs should be analyzed and considered in the system planning and upgrades. In this study, impact analysis of future EVs is conducted for a utility company of U.S. West Coast. Real data of distribution feeders is converted into the GridLAB-D model for running power flow analysis. An estimation of the additional loading of EVs in 2050 is provided by the utility company. Simple mitigation methods are tested to improve voltage profiles and complete this case study.

Xie, Jing↗

Regional Medium-Term Hourly Electricity Demand Forecasting Based on LSTM

This paper aims to forecast high-resolution (hourly) aggregated load for a certain region in the medium term (a few days to over a year). One region is defined as some places with similar climate characteristics because the climate influences people's daily lifestyles and hence the electric usage. We decom- pose the electric usage records into two parts: base load and seasonal load. Considering both temperature and time factors, different deep learning methods are adopted to characterize them. The first goal of our approach is to predict the peak load which is critical for power system planning. Furthermore, our proposed forecast method can provide the depiction of the hourly load profile to provide customized load curves for high- level real-time applications. The proposed method is tested on real-world historical data collected by CAISO, BPA, and PACW. The experimental results show that trained by three years of data, our method could reduce the prediction error for one-year lead hourly load below 5% MAPE, and predict the occurrence of the peak load for next year in CAISO with an error within three days. Furthermore, as a byproduct, an interesting observation on the impact of COVID-19 on human life was made and discussed based on these case studies.

deep learning↗

Quantifying the Protectability of Power Systems for Restoration Applications

With the increasing availability of distributed energy resources, controllable switches, and advanced metering infrastructure, distribution systems are exploring opportunities for improving system reliability through fault location, isolation, and service restoration. During permanent outages, this requires islanding microgrids and/or reconfiguration of the feeders; however, it is critical to assess the protection of the islanded/reconfigured networks before transition because the rated load and fault current conditions change. This paper presents a novel “protectability” metric that quantifies the protection performance and allows the operators to compare the effectiveness of the protection between two or more possible reconfiguration and islanding approaches. We present the mathematical formulation and assumptions for the metric. Multiple configurations of the Electric Power Research Institute J1 feeder, both in grid-connected and weak-sourced islanded operation, are used to demonstrate the performance of the metric with reference to overcurrent protection. Takeaways for future studies on system planning integration are provided.

distributed energy resources↗

Adaptive Power Flow Approximations With Second-Order Sensitivity Insights

The power flow equations are fundamental to power system planning, analysis, and control. However, the inherent non-linearity and non-convexity of these equations present formidable obstacles in problem-solving processes. To mitigate these challenges, recent research has proposed adaptive power flow linearizations that aim to achieve accuracy over wide operating ranges. The accuracy of these approximations inherently depends on the curvature of the power flow equations within these ranges, which necessitates considering second-order sensitivities. In this paper, we leverage second-order sensitivities to both analyze and improve power flow approximations. We evaluate the curvature across broad operational ranges and subsequently utilize this information to inform the computation of various sample-based power flow approximation techniques. Additionally, we leverage second-order sensitivities to guide the development of rational approximations that yield linear constraints in optimization problems. In conclusion, this approach is extended to enhance accuracy beyond the limitations of linear functions across varied operational scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Understanding the Quadrupole Mass Filter and Testing a High-Resolution QMS RGA for ITER

A common type of residual gas analyzer is the quadrupole mass spectrometer. One of the main components within this instrument is a mass filter known as the quadrupole. It is responsible for the selective throughput of the ionized gas particles - by ascending mass number - prior to ion impacts on the analyzer (or detector) surface from which the ion current signal is generated for processing. However, the quadrupole is not fully described in relation to the electric field characteristics and the function as an ion mass separator. This paper describes the basic origins of the electrical design, the intricate assembly criteria, and performance of the quadrupole within the spectrometer. A specialized quadrupole mass spectrometer is part of a configuration for a diagnostic gas analyzer system planned for ITER, a fusion research machine. It has a verified capability, essential as a diagnostic criterion for this reactor project, to successfully deconvolute the mass signals of Helium-4 and deuterium (reactor fuel exhaust gases, separated by only 0.026 atomic mass units), down to a relative three-percent concentration of the former gas. The associated preliminary testing, performed at the Oak Ridge National Laboratory, is also addressed. Finally, one of the key parameters used to express gas concentration, the relative sensitivity factor, will be explained, including an evaluation of dependency on other variables.

Marcus, Chris [ORNL] (ORCID:0000000190139636)↗