Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchrotron tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Four-dimensional microstructurally small fatigue crack growth in cyclically loaded nickel superalloy specimen

Here, we nondestructively image a low-solvus high refractory (LSHR) nickel base specimen microstructure during cyclic loading to characterize crack propagation during the microstructurally small crack (MSC) growth regime. Micro-computed tomography (uCT) is used to characterize the material density and identify crack interfaces, while high-energy diffraction microscopy (HEDM) provides snapshots of the microstructural orientation field changes. From these measurements, data are computationally reconstructed and coregistered to describe the specimen’s configuration before load, before crack nucleation, and throughout the crack propagation/loading process. An MSC forms at a FIB-cut notch, which was previously placed to concentrate stress at the center of the specimen gauge, and propagates along a facet parallel to the local {1 1 1} crystallographic plane. Analysis of available crystallographic slip directions and measured point-to-point disorientation axes indicate probable single and coplanar slip activity along FCC octahedral planes within this region. Similar analyses of other crack propagation facets reveal generally slower growth along directions favoring zig-zag cross and codirectional cross slip, which are often disfavored at room temperature.

36 MATERIALS SCIENCE↗

Search for Organic Nanoglobules in Carbonaceous Chondrites Using Microtomography

Primitive solar materials have various organic matters. In recent years, novel organic materials called organic nanoglobules of a few hundred micrometers in typical size were discovered in carbonaceous chondrites, IDPs, and comet 81P/Wild 2. The organic globules are spherical shape and in many cases with hollow structures. Composition of the globules are mainly aromatic carbon. The isotopic anomalies of SD and 6N 15 observed in the globules indicate that they were formed from photochemical reaction to ice particles at very low temperature environment, such as molecular clouds or outer protosolar disk. Aqueous alteration of organic matters and the gamma-ray irradiation to PAH are also suggested as alternative possible formation processes. If the globules are made from organic ice particles, the hollow regions of the globules are suggested to be once filled with volatile H20-rich organic ices, while if they were formed by aqueous alteration, the hollow regions should be filled with a fluid which caused the aqueous alteration. However, fluids in the globules have not been detected so far in the previous studies. If fluids were originally preserved in the hollows, they might be lost during destructive processes of sample separation or preparation for TEM observation. X-ray computed tomography (CT) is a nondestructive method which can determine 3-D internal structures of objects. SR (synchrotron radiation)-based imaging microtomography can give submicron spatial resolution [8] and was applied to micro textures in extraterrestrial materials, such as cometary grains captured by the Stardust mission [9]. If organic globules are observed non-destructively in carbonaceous chondrites by tomography, we can check the presence of fluids in the hollows. If fluids are preserved, we may analyze chemical and isotopic compositions of the fluids. The purpose of this study is to observe organic nanoglobules using imaging tomography for future analysis.

Matsumoto, T.↗

Real-time visualization of particle evolution during reactive flux-assisted processing of aluminum melts

Here, a multi-modal, multi-scale correlative tomography investigation of Al-TiC metal matrix composites processed via flux-assisted reaction synthesis is reported. Synchrotron X-ray microradiography is utilized to visualize the reaction and particle evolution in real-time. Changes in particle diameter and areal number density suggest that the process is nucleation- rather than growth-dominated. At 950 °C, the bulk of the reaction takes place in a relatively short time span of less than 600 s. The microstructure is imaged at higher resolution in 2D (scanning electron microscopy) and 3D (synchrotron X-ray nanotomography), revealing the formation of carbide particles with a hexagonal platelet morphology. We propose that the morphology arises due to the incorporation of Si impurities during the experiment. It is expected that the correlative tomography workflow and analysis may guide future metal matrix composite (MMC) processing strategies.

36 MATERIALS SCIENCE↗

Comparing the Purity of Rolled versus Evaporated Lithium Metal Films Using X-ray Microtomography

Here, we present a comparison of lithium metal films produced via rolling and thermal evaporation using synchrotron hard X-ray microtomography. In past studies of rolled lithium metal foils, a large number of C, O, and N impurities were found and identified as the key cause for failure in lithium metal cells. In this comparison, the X-ray tomography data show that the evaporated lithium metal films have an average impurity concentration of 19 particles/mm3 in comparison to 1350 particles/mm3 in the rolled lithium metal. An analysis of the inner substrate/lithium interface and outer lithium surface of the thermally evaporated film shows a much greater concentration of impurities at these interfaces, further emphasizing the importance of interface engineering in producing high-quality lithium metal batteries. Furthermore, we show that, if surface contamination can be avoided, it is possible to obtain lithium films with no impurities detectable by synchrotron hard X-ray tomography.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Convolutional neural network based non-iterative reconstruction for accelerating neutron tomography *

Abstract Neutron computed tomography (NCT), a 3D non-destructive characterization technique, is carried out at nuclear reactor or spallation neutron source-based user facilities. Because neutrons are not severely attenuated by heavy elements and are sensitive to light elements like hydrogen, neutron radiography and computed tomography offer a complementary contrast to x-ray CT conducted at a synchrotron user facility. However, compared to synchrotron x-ray CT, the acquisition time for an NCT scan can be orders of magnitude higher due to lower source flux, low detector efficiency and the need to collect a large number of projection images for a high-quality reconstruction when using conventional algorithms. As a result of the long scan times for NCT, the number and type of experiments that can be conducted at a user facility is severely restricted. Recently, several deep convolutional neural network (DCNN) based algorithms have been introduced in the context of accelerating CT scans that can enable high quality reconstructions from sparse-view data. In this paper, we introduce DCNN algorithms to obtain high-quality reconstructions from sparse-view and low signal-to-noise ratio NCT data-sets thereby enabling accelerated scans. Our method is based on the supervised learning strategy of training a DCNN to map a low-quality reconstruction from sparse-view data to a higher quality reconstruction. Specifically, we evaluate the performance of two popular DCNN architectures—one based on using patches for training and the other on using the full images for training. We observe that both the DCNN architectures offer improvements in performance over classical multi-layer perceptron as well as conventional CT reconstruction algorithms. Our results illustrate that the DCNN can be a powerful tool to obtain high-quality NCT reconstructions from sparse-view data thereby enabling accelerated NCT scans for increasing user-facility throughput or enabling high-resolution time-resolved NCT scans.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A hybrid machine-learning approach for analysis of methane hydrate formation dynamics in porous media with synchrotron CT imaging

Fast multi-phase processes in methane hydrate bearing samples pose a challenge for quantitative micro-computed tomography study and experiment steering due to complex tomographic data analysis involving time-consuming segmentation procedures. This is because of the sample's multi-scale structure, which changes over time, low contrast between solid and fluid materials, and the large amount of data acquired during dynamic processes. Here, a hybrid approach is proposed for the automatic segmentation of tomographic data from time-resolved imaging of methane gas-hydrate formation in sandy granular media, which includes a deep-learning 3D U-Net model. To prepare a training dataset for the 3D U-Net, a technique to automate data labeling based on sample-specific information about the mineral matrix immobility and occasional fluid movement in pores is proposed. Automatic segmentation allowed for studying properties of the hydrate growth in pores, as well as dynamic processes such as incremental flow and redistribution of pore brine. Results of the quantitative analysis showed that for typical gas-hydrate stability parameters (100 bar methane pressure, 7°C temperature) the rate of formation is slow (less than 1% per hour), after which the surface area of contact between brine and gas increases, resulting in faster formation (2.5% per hour). Hydrate growth reaches the saturation point after 11 h of the experiment. Finally, the efficacy of the proposed segmentation scheme in on-the-fly automatic data analysis and experiment steering with zooming to regions of interest is demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nondestructive geochemical characterization of fossil hominin taphonomy and burial history

To date, only three Homo habilis specimens have been discovered that have associated craniodental and postcranial elements, providing a limited fossil record of the ontogeny and morphology of early members of the genus Homo. Recently, a nearly complete dentition, likely attributable to H. habilis, was discovered and excavated from early Pleistocene-age fluvial-lacustrine sediments of the upper Burgi Member of the Koobi Fora Formation at site F25787 in Area 13, near Ileret, Kenya. On the surface less than 15 m away, at site F25966, postcranial elements were found, which, if from the same individual as the nearby dentition, would represent the fourth associated craniodental and postcranial assemblage of this species. We developed a geochemical taphonomic history of these ca. 2 Ma hominin fossils using nondestructive X-ray based microanalytical tools (synchrotron and benchtop X-ray fluorescence chemical imaging and micro- and nano-computed tomography volumetric reconstruction), bulk analyses of sediments and paleosols at the excavation sites, and sedimentologic and stratigraphic observations. We integrate the chemical and physical taphonomic histories to test whether teeth (excavated in situ) and postcranial bones (eroded onto the outcrop surface) derive from a single individual. Minor differences in taphonomic history are attributable to the different biomineral properties of the dental and osseous components and to differences in physical damage during early post-mortem scavenging, dispersal, and burial in adjacent depositional settings. Microscale geochemical mapping enabled the temporal ordination of chemical and physical events in the specimens’ chemical taphonomic histories. Specifically, authigenic Fe- and K-bearing clays and Y, U, and Sr uptake occurred in post-burial fractures in bones and were also incorporated pervasively throughout dentin in teeth. Barite mineralization occurred along the latest fractures in both materials, and as a coating on tooth roots. The stratigraphic, taphonomic, and geochemical evidence supports the interpretation that the hominin fossils represent a single individual. Finally, successful application of these nondestructive sample characterization methods demonstrates capabilities for thorough interrogation of the taphonomic histories of other potential hominin fossil associations, enabling more robust and accurate palaeontologic constraints using those relationships.

36 MATERIALS SCIENCE↗

Synchrotron-based diffraction-enhanced imaging and diffraction-enhanced imaging combined with CT X-ray imaging systems to image seeds at 30 keV

Utilized the upgraded Synchrotron-based non-destructive Diffraction-enhanced imaging and Diffraction-enhanced imaging coupled with CT X-ray imaging systems to image the chickpea seeds, to enhance the contrast in plant root architecture, visibility of fine structures of root architecture growth and some aspects of physiology at acceptable level. DEI-CT images were acquired with 30 keV synchrotron X-rays. A series of DEI-CT slices were assembled together, to form a 3D data set. DEI-CT images explored more structural information and morphology. Noticed detailed anatomical, physiological observations, and contrast mechanisms. Furthermore, with these systems, some of the complex plant traits, root morphology, growth of laterals and subsequent laterals can be visualized directly.

36 MATERIALS SCIENCE↗

X-Ray Micro- and Nano-Tomography Analysis of Bennu Samples: A Preliminary Report

X-ray tomography (XCT) is an effective technique for obtaining the 3D structures of returned samples. XCT using synchrotron radiation provides high-resolution CT images with quantitative information. The XCT systems at SPring-8, an SR facility in Japan, have been used to analyze samples returned from the asteroids Itokawa and Ryugu. In this study, we plan to apply SR-XCT to samples returned from the asteroid Bennu.

A Tsuchiyama↗

Nanoscale Three-Dimensional Imaging of Integrated Circuits Using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer

X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but it is difficult to implement due to the competing requirements of X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while addressing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot on a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with a high signal-to-noise ratio. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enables nanoscale, element-specific X-ray imaging in a compact footprint. The proof of concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in six layers of a Cu-SiO 2 integrated circuit, and a path toward finer resolution and enhanced imaging capabilities is discussed.

47 OTHER INSTRUMENTATION↗

Origins of high ductility exhibited by an extruded magnesium alloy Mg-1.8Zn-0.2Ca: Experiments and crystal plasticity modeling

Low ductility and strength are major bottlenecks against Mg alloys' wide applications. In this work, we systematically design the composition and fabrication process for a low-alloyed Mg-Zn-Ca alloy, showing that it can be extruded at low temperatures (~ 250 degrees C) and high speeds (~2 mm/s). After the extrusion, this alloy exhibits a substantially weakened basal texture, relatively small grain size, very high tensile elongation (~ 30%), and good strength. The origin of the considerably improved ductility was studied using a combination of three-dimensional atom probe tomography (3D-APT), transmission electron microscopy (TEM), electron backscattered diffraction (EBSD) in conjunction with surface slip trace analysis, in-situ synchrotron X-ray diffraction, and elasto-plastic self-consistent (EPSC) modeling. Co-segregation of Zn and Ca atoms at a grain boundary is observed and associated with texture weakening and grain boundary mediated plasticity, both improving the ductility. While basal slip and prismatic slip are identified as the dominant deformation systems in the alloy, the ratio between their slip resistances is substantially reduced relative to pure Mg and most other Mg alloys, significantly contributing to the improved ductility of the alloy. This Mg-Zn-Ca alloy exhibiting excellent mechanical properties and low fabrication cost is a promising candidate for industrial productions.

36 MATERIALS SCIENCE↗

Synchrotron Imaging of Pore Formation in Li Metal Solid-State Batteries Aided by Machine Learning

High-rate capable, reversible lithium metal anodes are necessary for next generation energy storage systems. In situ tomography of Li/LLZO/Li cells is carried out to track morphological transformations in Li metal electrodes. Machine learning enables tracking the lithium metal morphology during galvanostatic cycling. Nonuniform lithium electrode kinetics are observed at both electrodes during cycling. Hot spots in lithium metal are correlated with microstructural anisotropy in LLZO. Mesoscale modeling reveals that regions with lower effective properties (transport and mechanical) are nuclei for failure. Advanced visualization combined with electrochemistry represents an important pathway toward resolving non-equilibrium effects that limit rate capabilities of solid-state batteries.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Prevention of lithium-ion battery thermal runaway using polymer-substrate current collectors

Isolating electronically conducting material from internal short circuits is a promising way to prevent the onset of thermal runaway within lithium-ion cells. Here, a metal-coated polymer current collector, which is designed to disconnect internal short circuits by withdrawing from the heating region, is tested in 18650 cells. In addition to having lower mass and manufacturing costs, cells with metal-coated polymer current collectors demonstrate a reduced risk of thermal runaway during nail penetration. High-speed synchrotron X-ray radiography of 18650 cells during nail-penetration testing, in tandem with pre- and post-mortem X-ray computed tomography, provides insights into the function of the current collectors. The results are compared with those of 18650 cells with standard commercial aluminum and copper current collectors. Cells with aluminum-coated polymer current collectors demonstrated 100% success in thermal runaway prevention during nail penetration, retaining a cell voltage >4.00 V, while standard cells consistently experienced thermal runaway.

25 ENERGY STORAGE↗

A lathe system for micrometre-sized cylindrical sample preparation at room and cryogenic temperatures

A simple two-spindle based lathe system for the preparation of cylindrical samples intended for X-ray tomography is presented. The setup can operate at room temperature as well as under cryogenic conditions, allowing the preparation of samples down to 20 and 50 µm in diameter, respectively, within minutes. Case studies are presented involving the preparation of a brittle biomineral brachiopod shell and cryogenically fixed soft brain tissue, and their examination by means of ptychographic X-ray computed tomography reveals the preparation method to be mainly free from causing artefacts. Since this lathe system easily yields near-cylindrical samples ideal for tomography, a usage for a wide variety of otherwise challenging specimens is anticipated, in addition to potential use as a time- and cost-saving tool prior to focused ion-beam milling. Fast sample preparation becomes especially important in relation to shorter measurement times expected in next-generation synchrotron sources.

36 MATERIALS SCIENCE↗

Heterogeneous fatigue damage in a nickel-based single-crystal superalloy unraveled using correlative 3D X-ray technology

Nickel-based single-crystal (Ni-SX) superalloys under cyclic stress are susceptible to cracking at stress-concentration sites, eventually leading to low-cycle fatigue (LCF) failure. LCF cracks typically originate from intrinsic defects (e.g., voids and carbides) within solidified dendrites. However, systematic quantitative experimental analyses of defect-mediated local damage remain limited. To thoroughly understand the microscopic origins and evolution of LCF damage, correlated 3D mapping of dendrites across various regions is essential. Here, in this study, macroscale micro-computed tomography (μ-CT) was initially used to capture internal interdendritic secondary cracks within bulk DD413 superalloy after LCF testing at 760 °C. Subsequently, a multimodal methodology combining synchrotron 3D microdiffraction (3D-μXRD), high-resolution μ-CT, and electron microscopy was established. This approach allowed precise localization of internal damage zones near interdendritic secondary cracks and detailed mapping of the 3D correlated distributions of dendrites, defects, and residual stress/strain fields within these zones at submicron spatial resolution. Finally, the same approach was applied to specimens subjected to interrupted loading at approximately 40 % of the fatigue life to uncover the early damage states of dendrites. The dendrite cores (DCs) and interdendritic regions (IDs) exhibit microscale heterogeneous mechanical responses: nearly defect-free DCs accumulate local irreversible slip along specific slip systems to generate slip bands, while the IDs containing various defects accommodate local microplasticity through the activation of multiple slip systems around these defects. The local tensile stress near defects in the IDs exceeds that in the DC slip band regions by more than threefold, leading to the generation of local damage zones within the IDs. Chain-like defect distributions facilitate the interconnection of these local zones into a continuous damage region, further elevating the overall tensile stress in the IDs. Additionally, geometrically necessary dislocations alone are insufficient as indicators of LCF damage; both the internal stress state and its magnitude must be considered. These experimental results provide critical data and insights for the development of multi-physics fatigue models.

Localized deformation↗

Linking void and interphase evolution to electrochemistry in solid-state batteries using operando X-ray tomography

Despite progress in solid-state battery engineering, our understanding of the chemo-mechanical phenomena that govern electrochemical behavior and stability at solid-solid interfaces remains limited compared to solid-liquid interfaces. Here, we use operando synchrotron X-ray computed microtomography to investigate the evolution of lithium/solid-state electrolyte interfaces during battery cycling, revealing how the complex interplay among void formation, interphase growth, and volumetric changes determines cell behavior. Void formation during lithium stripping is directly visualized in symmetric cells, and the loss of contact that drives current constriction at the interface between lithium and the solid-state electrolyte (Li10SnP2S12) is quantified and found to be the primary cause of cell failure. The interphase is found to be redox-active upon charge, and global volume changes occur due to partial molar volume mismatches at either electrode. Finally, these results provide new insight into how chemo-mechanical phenomena can impact cell performance, which is necessary to understand for the development of solid-state batteries.

42 ENGINEERING↗