Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “standard operating procedure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Specimen sizing and remaining life sample calculations for high temperature reactor material surveillance

Advanced high-temperature nuclear reactors rely on structural components that will operate for decades under combined mechanical, thermal, and environmental loading. Materials surveillance programs are a promising strategy for managing the resulting uncertainty in long-term structural integrity by monitoring degradation in service using passively actuated mechanical test articles. Previous reports have developed a simplified, spreadsheetimplementable framework for sizing these test articles and for inferring accumulated creep damage and remaining life from ex-situ test data. This report advances that work toward practical deployment by providing a sample-problem book: a collection of worked, end-toend examples in which the ASME Section III, Division 5 design analysis of a representative high-temperature reactor component is carried through to a sized surveillance article, verified with detailed finite-element analysis, and concluded with a remaining-life assessment based on an assumed ex-situ creep-rate measurement on the retrieved specimen. The report also summarizes ongoing ANL engagement with ASTM Committee E10 on Nuclear Technology and Applications toward drafting a standard covering surveillance procedures for advanced reactors.

Barua, Bipul (ORCID:0000000247184113)↗

PV Reference Cells for Outdoor Use: An Investigation of Calibration Factors

Reference cells are widely used in the photovoltaic (PV) industry to measure irradiance. For field applications and outdoor use, a variety of products are on the market, and they are often perceived as a low-cost alternative to thermopile radiometers. But reference cell characteristics differ substantially from the latter, therefore measurements made by one category of instrument cannot be substituted for or directly compared with the other. The National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory is currently in a multiyear effort to develop guidance and recommendations for the design and use of outdoor reference cells, with a view to reducing inconsistencies and measurement uncertainty. The core of this effort is the long-term deployment of 39 units of 10 distinct types made by 6 manufacturers. This report compares the calibration factors provided by manufacturers - which most users rely upon - to those measured at a high level of accuracy by NREL's Cell Lab. It also reports on the application of the Broadband Outdoor Radiometer Calibration (BORCAL) method to reference cells. As a group, the factory calibrations for the crystalline silicon cells showed a small positive bias of +0.7%, with a tight distribution around this value. This is a very good result for the manufacturers. The two World Photovoltaic Scale cells constituted outliers, with a mean deviation of -0.8%, which is still within the reported uncertainty ranges. The data collected during the BORCAL procedures show a strong and systematic fluctuation of the apparent responsivity of the reference cells over the course of a day, which was anticipated. Consequently, the standard BORCAL R@45 calibration factors underestimated the reference cell responsivities by 1%-4%. An alternate responsivity indicator was developed, R'@30, incorporating adjustments for temperature response, spectral response, and directional response. This reduced the mean deviation to -0.4% compared to the Cell Lab. Further, two independent BORCAL sessions were able to produce the same values to within ±0.2%. This could be a viable approach for verifying reference cells using existing BORCAL infrastructure, for example, to evaluate their long-term stability. The daily profiles of responsivity obtained during the BORCAL sessions (provided in Appendix A) show clear patterns of differences between models, which provides evidence that their directional responses differ from each other; thus, two sensors that are calibrated correctly might give the same reading at 30° zenith angle but systematically different readings at 60°. The impact of these inconsistencies in field operation will be quantified using the long-term observations started in 2020.

14 SOLAR ENERGY↗

An Alternative Timing and Synchronization Approach for Situational Awareness and Predictive Analytics

Accurate and synchronized timing information is required by power system operators for controlling the grid infrastructure (relays, Phasor Measurement Units (PMUs), etc.) and determining asset positions. Satellite-based global positioning system (GPS) is the primary source of timing information. However, GPS disruptions today (both intentional and unintentional) can significantly compromise the reliability and security of our electric grids. A robust alternate source for accurate timing is critical to serve both as a deterrent against malicious attacks and as a redundant system in enhancing the resilience against extreme events that could disrupt the GPS network. To achieve this, we rely on the highly accurate, terrestrial atomic clock-based network for alternative timing and synchronization. In this paper, we discuss an experimental setup for an alternative timing approach. The data obtained from this experimental setup is continuously monitored and analyzed using various time deviation metrics. We also use these metrics to compute deviations of our clock with respect to the National Institute of Standards and Technologys (NIST) GPS data. The results obtained from these metric computations are elaborately discussed. Finally, we discuss the integration of the procedures involved, like real-time data ingestion, metric computation, and result visualization, in a novel microservices-based architecture for situational awareness.

Chinthavali, Supriya↗

Analysis of Data Fusion Between Waveform Events and Radionuclide Detections Reported in 2021 by the International Data Centre

During this project, we assessed the percentage of events reported by the International Data Centre (IDC) that are candidates for evaluation using data fusion methods. We calculated the percentage of waveform (seismic, hydroacoustic, infrasound, SHI) events that may be associated with radionuclide (RN) detections and vice versa. For this task, data fusion means identifying RN detections that may be associated with SHI events. The task of producing a fused SHI and RN bulletin is included in the IDC operational manual. As of 2022, the production of a fused event bulletin remains incomplete, largely because methods for producing the bulletin are under development. Nonetheless, simple methods for data fusion have been developed and preliminary software tools are available at the IDC to associate SHI events and RN detections. This report is a first look at the percentage of SHI events that may be candidates for fusion with RN detections or bulletins. One year of IDC bulletin data (2021) is considered in this report. It is important to note that there were no known nuclear explosions during this time period. Hence, we expect that events during this time period would generate SHI and RN signals. If many SHI events are candidates for fusion with RN data, greater priority should be placed on establishing screening procedures before and/or during the fusion process. By contrast, if the number of candidate events is diminishingly small, then data fusion is not a driver for further development of event or detection screening at the IDC. LLNL reviewed the events reported in the Standard Event Bulletin (SEB) and determined which events are candidates for fusion with the Reviewed Radionuclide Reports (RRR). Much of the work involves establishing a metric or metrics for determining whether a Reviewed Event Bulletin (REB) event is a candidate for data fusion.

58 GEOSCIENCES↗

Gaseous contaminant transfer in membrane-based air-to-air energy exchangers

Membrane-based air-to-air energy exchangers (M–AAEEs) transfer heat and moisture between building exhaust air and fresh ventilation air streams through a membrane, thereby reducing the energy required for conditioning the fresh ventilation air. Energy exchangers are typically used in buildings with relatively clean building exhaust air, such as office buildings and schools. Recently interest in using energy exchangers in a wider range of buildings has grown, to reduce the energy consumption associated with the heating, ventilating, and air-conditioning (HVAC) systems in these buildings. However, if the building exhaust air is not clean, as would be the case for laboratories or factories, new risks are encountered when using energy exchangers. It is possible that gaseous contaminants in the exhaust air may also transfer along with the moisture through the membranes, contaminating the incoming fresh ventilation air. Current test standards provide a test procedure to determine the contamination of the fresh ventilation air by measuring the transfer of an inert tracer gas in an energy exchanger. However, the tracer gas test may not represent the transfer of common indoor air contaminants due to differences in their transport properties. Therefore, in this study, an experimental facility is developed to determine the transfer of seven different contaminants through two membranes (porous and dense) at different flow rates. Contaminant transfer is quantified using a parameter called the exhaust contaminant transfer ratio (ECTR), which gives the fraction of the contaminants transferred from the exhaust air to the fresh ventilation air. A theoretical model based on the effectiveness-number of transfer units (ε-NTU) correlation and moisture transfer resistance of the membrane is presented to determine transfer through porous membranes and validated with experimental results. The major contribution of this paper is that it presents a simple method to predict the transfer of different contaminants through a porous membrane based on the moisture transfer resistance of the membrane at different operating conditions. It is found that as contaminant diffusivity decreases, ECTR generally also decreases, and as the flow rate increases, ECTR decreases, which is consistent with the predictions from the correlation.

42 ENGINEERING↗

Slip velocity boundary conditions for the lattice Boltzmann modeling of microchannel flows

Abstract Slip flows in ducts are important in numerous engineering applications, most notably in microchannel flows. Compared to the standard no‐slip Dirichlet condition, the case of slip formulates as a Robin‐type condition for the fluid tangential velocity. Such an increase in mathematical complexity is accompanied by a more challenging numerical transcription. The present work concerns with this topic, addressing the modeling of the slip velocity boundary condition in the lattice Boltzmann method (LBM) applied to steady slow viscous flows inside ducts of nontrivial shapes. As novelty, we extend the newly revised local second‐order boundary (LSOB) Dirichlet fluid flow method [ Philos. Trans. R. Soc. A 378, 20190404 (2020)] to implement the slip velocity condition within the two‐relaxation‐time (TRT) framework. The LSOB follows an in‐node philosophy where its operation principle seeks to explicitly reconstruct the unknown boundary populations in the form of a third‐order accurate Chapman–Enskog expansion, where the wall slip condition is built‐in as a normal Taylor‐type condition. The key point of this approach is that the required first‐ and second‐order momentum derivatives, rather than computed through nonlocal finite difference approximations, are locally determined through a simple local linear algebra procedure, whose formulation is particularly aided by the TRT symmetry argument. To express the obtained derivatives, two approaches are considered, called and , which operate with node and wall variables, respectively. These two formulations are developed to prescribe the physical slip condition over plane and curved walls, including the corners. Their consistency and accuracy characteristics are examined against alternative linkwise strategies to impose the wall slip velocity, such as the kinetic‐based diffusive bounce‐back scheme, the central linear interpolation slip scheme, and the multireflection slip scheme. The several slip schemes are tested over different 3D microchannel configurations, with walls not conforming with the LBM uniform mesh. Numerical tests confirm the advanced accuracy characteristics of the proposed LSOB slip boundary scheme, revealing the added challenge of the wall slip modeling, and that parabolic accuracy is a necessary requirement to reach second‐order accuracy within this problem class.

Silva, Goncalo↗

High-resolution ion mobility based on traveling wave structures for lossless ion manipulation resolves hidden lipid features

Abstract High-resolution ion mobility (resolving power > 200) coupled with mass spectrometry (MS) is a powerful analytical tool for resolving isobars and isomers in complex samples. High-resolution ion mobility is capable of discerning additional structurally distinct features, which are not observed with conventional resolving power ion mobility (IM, resolving power ~ 50) techniques such as traveling wave IM and drift tube ion mobility (DTIM). DTIM in particular is considered to be the “gold standard” IM technique since collision cross section (CCS) values are directly obtained through a first-principles relationship, whereas traveling wave IM techniques require an additional calibration strategy to determine accurate CCS values. In this study, we aim to evaluate the separation capabilities of a traveling wave ion mobility structures for lossless ion manipulation platform integrated with mass spectrometry analysis (SLIM IM-MS) for both lipid isomer standards and complex lipid samples. A cross-platform investigation of seven subclass-specific lipid extracts examined by both DTIM-MS and SLIM IM-MS showed additional features were observed for all lipid extracts when examined under high resolving power IM conditions, with the number of CCS-aligned features that resolve into additional peaks from DTIM-MS to SLIM IM-MS analysis varying between 5 and 50%, depending on the specific lipid sub-class investigated. Lipid CCS values are obtained from SLIM IM ( TW(SLIM) CCS) through a two-step calibration procedure to align these measurements to within 2% average bias to reference values obtained via DTIM ( DT CCS). A total of 225 lipid features from seven lipid extracts are subsequently identified in the high resolving power IM analysis by a combination of accurate mass-to-charge, CCS, retention time, and linear mobility-mass correlations to curate a high-resolution IM lipid structural atlas. These results emphasize the high isomeric complexity present in lipidomic samples and underscore the need for multiple analytical stages of separation operated at high resolution. Graphical abstract

Reardon, Allison R. (ORCID:0000000165830134)↗

EVs@Scale NextGen Profiles: High Level Analysis and Procedures Report

As part of the U.S. DOE EVs@Scale consortium, the NextGen Profiles (NGP) project presents analysis and results from the study of High Power Charging Electric Vehicles and Battery Charging Infrastructure. High Power Charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. The NextGen Profiles project has three pillars of investigation: Electric Vehicle Charging Profile Capture, Electric Vehicle Service Equipment Performance Characterization and Fleet Utilization analysis. All NextGen Profiles project testing was conducted under test conditions that comprise a diverse range of realistic real-world operating conditions including nominal conditions that should transfer the maximum allowable energy in the minimum time possible and off-nominal conditions that typify charging performance under suboptimal charging conditions. Results from 13 unique EVs, eight EVSEs and four electrified fleets are included in the NextGen Profiles project analysis.

33 ADVANCED PROPULSION SYSTEMS↗

A digital twin solution for floating offshore wind turbines validated using a full-scale prototype

Abstract. In this work, we implement, verify, and validate a physics-based digital twin solution applied to a floating offshore wind turbine. The digital twin is validated using measurement data from the full-scale TetraSpar prototype. We focus on the estimation of the aerodynamic loads, wind speed, and section loads along the tower, with the aim of estimating the fatigue lifetime of the tower. Our digital twin solution integrates (1) a Kalman filter to estimate the structural states based on a linear model of the structure and measurements from the turbine, (2) an aerodynamic estimator, and (3) a physics-based virtual sensing procedure to obtain the loads along the tower. The digital twin relies on a set of measurements that are expected to be available on any existing wind turbine (power, pitch, rotor speed, and tower acceleration) and motion sensors that are likely to be standard measurements for a floating platform (inclinometers and GPS sensors). We explore two different pathways to obtain physics-based models: a suite of dedicated Python tools implemented as part of this work and the OpenFAST linearization feature. In our final version of the digital twin, we use components from both approaches. We perform different numerical experiments to verify the individual models of the digital twin. In this simulation realm, we obtain estimated damage equivalent loads of the tower fore–aft bending moment with an accuracy of approximately 5 % to 10 %. When comparing the digital twin estimations with the measurements from the TetraSpar prototype, the errors increased to 10 %–15 % on average. Overall, the accuracy of the results is promising and demonstrates the possibility of using digital twin solutions to estimate fatigue loads on floating offshore wind turbines. A natural continuation of this work would be to implement the monitoring and diagnostics aspect of the digital twin to inform operation and maintenance decisions. The digital twin solution is provided with examples as part of an open-source repository.

17 WIND ENERGY↗

Thermocouple Testing in Support of the AGR-5/6/7 Experiment

This report documents thermocouple testing performed in IRC Lab C-15 over a period of seven years. This testing supported selection and characterization of the thermocouple set used in the AGR-5/6/7 experiment. The following summary was taken directly from the report. Temperature measurement is a challenging aspect of very high temperature irradiation experiments because commonly used high-temperature commercial thermocouples such as platinum-rhodium (Types S, R, and B) and tungsten-rhenium (Type C), suffer dramatic drift because of neutron-induced transmutation. As a result, these types of thermocouples, which are used routinely for industrial temperature measurements outside of reactors, are used only in very special circumstances for reactor experiments. Conversely, because of their low neutron cross-sections, Type N thermocouples are affected to only a limited extent by neutron irradiation. However, the use of these nickel-based thermocouples is limited when the temperature exceeds 1050°C due to drift arising from minor alloying elements migrating from the thermocouple's metal sheath to the thermoelements. This change in the composition of the thermo-elements results in significant decalibration of the signal. The issues described above were recognized during the early planning stages of the final AGR experiment (designated AGR-5/6/7), and a thermocouple furnace testing program was performed over a seven-year period (2014-2019, 2021) to first select and then characterize the best thermocouple set for the high temperature regions of the AGR-5/6/7 irradiation experiment. The calculated temperature range of the AGR-5/6/7 experiment was 600–1500°C. For temperatures below 1000°C standard Type N thermocouples were deemed adequate. The furnace testing campaign identified two thermocouple types suitable for measuring temperatures above 1000°C, a Mo/Nb thermocouple developed at INL called HTIR-TC, and a Type N thermocouple developed by Cambridge University (called herein Cambridge Type N), which featured a custom high nickel alloy sheath. One of the original goals of the furnace testing program was to identify a thermocouple capable of low drift operation near the peak temperature expected in AGR-5/6/7, i.e., about 1400°C. The HTIR-TC design appeared promising in this regard, however a manufacturing difficulty proved to be a barrier and instead the furnace testing focused on drift performance at 1250°C. The manufacturing difficulty was that the Nb sheaths of the HTIR-TCs experienced extreme embrittlement when heat treated at 1600°C or greater. Heat treatment is needed to stabilize the emf output of this TC type, and the higher the heat treatment temperature the higher the peak temperature of stable operation. Because of the sheath embrittlement the heat treatment temperature had to be lowered to 1450°C resulting in a stable operating temperature of about 1250°C. One of the successes of the furnace testing program was identification of a shortcoming in the heat treatment procedure that had been traditionally used in the production of HTIR-TCs. The shortcoming was that the entire heated length of the HTIR-TC sensor was not being heat treated, but rather only the part of the sensor expected to experience temperatures above 1000°C. The problem manifested itself when the thermocouples were removed from the heat treat furnace and placed in another furnace with a different geometry, their indicated temperatures would be widely scattered, but mostly in the negative direction. The solution was to heat treat the entire heated length of the sensor. Since the deepest immersion depth in the AGR-5/6/7 experiment was about 40 inches, a heat treatment length of 48 inches was used. After this change was implemented, thermocouples which were moved into a new environment with a different temperature profile (i.e., a different furnace), produced accurate temperature measurements. Although assembly of the AGR-5/6/7 experiment was completed in September of 2017 (and irradiation begun in 2018), furnace testing of thermocouples continued in 2018 and 2019. The main purpose of this testing was to establish very long-term drift characteristics of the HTIR and Cambridge Type N thermocouples installed in the experiment. Representative thermocouples from the same lots as those installed in the AGR-5/6/7 experiment were used. Additionally, thermocouples of different designs, (particularly variations on the HTIR-TC design) were "piggy-backed" on this testing program to provide insights for instrumenting future very high temperature irradiation experiments. This two-year testing program demonstrated that HTIR-TCs and Cambridge Type N TCs could operate at 1250°C for up to 10,000 hrs (and in some cases longer) while experiencing negative drifts on the order of 2-4°C/1000 hrs. This performance was considered acceptable given the extreme operating environment the sensors faced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass Spectrometer Transient Analysis

This software implements a complete preprocessing pipeline for transient mass spectrometry (MS) data collected during TAP (Temporal Analysis of Products) experiments. It is designed to extract chemically meaningful fluxes from overlapping ion signals by applying a calibrated defragmentation matrix and solving the resulting linear system using non-negative least squares (NNLS) regression. The core script, preprocess_mass_spec.py, performs the following operations: Gain correction: Applies amplifier gain scalars derived from inert-packed calibration pulses to normalize signal intensities across AMUs and acquisition settings. Background subtraction: Removes experiment baselines using user-defined time windows, ensuring compatibility with slow-diffusing species and preventing negative values that would interfere with NNLS. Options to subtract before and after defragmentation. Defragmentation: Constructs a fragmentation matrix A from zeroth moments of calibration pulses (equal molar gas:inert mixtures) and solves Ax=b at each time point, where b is the raw MS signal and x is the estimated species flux. The matrix is normalized to inert signals and accounts for instrument-specific fragmentation behavior. Pulse-mode handling: Supports both averaged and individual pulse modes, enabling statistical treatment of fluxes and calculation of standard deviations. Integration and output: Computes zeroth moments (integrated fluxes) and exports time-resolved and integrated data in CSV format, suitable for downstream kinetic modeling. The software is validated using both virtual TAP simulations (VTAP) and experimental data from propane dehydrogenation (PDH) on CrOx/Al2O3 catalysts. It preserves temporal resolution by applying NNLS point-by-point across the pulse duration (typically 6,000+ time slices per pulse), leveraging the linear superposition principle to reconstruct full flux profiles. The defragmented outputs are compatible with kinetic extraction methods such as the G and Y procedures, which are used to derive rate–concentration relationships from TAP data. The details of these validations are discussed in detail in the supporting manuscript and supporting information. Example data and output files are also included. The methodology is robust to experimental noise and drift, with calibration protocols that account for pulse size effects, MS aging, and inert gas normalization. The software is modular, reproducible, and tailored for high-throughput TAP-MS workflows in catalysis research.

Kristy, Stephen [Idaho National Laboratory (INL), ↗

Heat load measurements for the PIP-II pHB650 cryomodule

This study presents a brief overview of the 1st and 2nd phases and an in-depth analysis of the 3rd phase heat load testing performed on the pHB650 (prototype High Beta 650 MHz) cryomodule at PIP2IT (PIP-II Injector Test Facility), with a focus on both the results and the methodological advancements that have improved testing efficiency and accuracy. A key challenge identified in the testing campaign is the higher-than-expected heat loads observed in the first PIP-II (Proton Improvement Plan II) prototype cryomodules (pSSR1 and pHB650) tested at PIP2IT. Elevated heat loads are concerning given the fixed capacity of the PIP-II cryoplant that is currently being installed at Fermilab. However, understanding the sources of these elevated heat loads offers a critical opportunity to implement effective heat load mitigations on upcoming PIP-II cryomodules to stay within the available capacity of the PIP-II cryoplant. The study includes a summary of test results, descriptions of measurement procedures, and key observations on parameters directly and indirectly related to heat load measurements. Direct observations include measured heat loads and the effectiveness of JT heat exchanger under varying conditions, while indirect observation analyze factors such as the temperature distribution on the two-phase pipe and relief piping under varying conditions. Thermal acoustic oscillations (TAO) were identified during testing, which was mitigated by replacing the original G10 stem with a stainless steel stem equipped with wipers for the cryomodule cooldown valve. A major innovation during pHB650 Phase 3 testing was the development of an automated Python script to streamline data acquisition, analysis, and reporting of heat load results. This script automatically retrieved data from ACNET (Accelerator Control Network), performed heat load calculations, and generated detailed reports featuring plots and tables. This advancement significantly reduced manual labor and enhanced the thoroughness of data analysis compared to earlier campaigns. The heat load test reports were promptly uploaded to the electronic logbook shortly after each test, enabling rapid feedback and collaboration between the SRF and cryogenic teams. The heat load measurements included various components: HTTS (high-temperature thermal shield), LTTS (low-temperature thermal shield), 2K isothermal and non-isothermal heat loads. Results were recorded both within the cryomodule and between the bayonet can supply and return. Measurements were conducted under different operating conditions such as "standard", "linac", and "simulated dynamic". Additionally, HTTS and LTTS heat loads were calculated in real time, allowing for the tracking of thermal stability and identification of changes during testing, both in steady-state and transient conditions. The results of this testing campaign not only provide valuable insights into the performance of the pHB650 cryomodule but also highlight best practices and lessons learned that will inform future cryomodule testing at PIP2IT. These include adopting automated tools for data analysis, refining real-time measurement capabilities, and emphasizing detailed pre-test planning. The framework established in this campaign aims to set an improved standard for cryomodule testing and heat load reporting in future cryomodule test campaigns.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗

Progress Report on Graphite-Salt Interaction Studies (FY21)

This report summarizes the activities performed in FY21 to investigate the interactions between nuclear graphite and molten salts, such as FLiNaK. First, building on last year’s achievements, the team improved the procedure for measurements on pressurized salt intrusion in nuclear graphite and performed new experiments at variable pressures with specimens of different sizes and shapes. Additionally, the team actively provided suggestions and comments for ASTM D8091, Standard Guide for Impregnation of Graphite with Molten Salts , which came up for periodic revision in 2021. Second, the team expanded its capabilities to further characterize salt-impregnated graphite by procuring and installing a laser-induced breakdown spectroscopy (LIBS) instrument capable of producing a 3D chemical composition of a surface and subsurface region of specimens. A methodology for accurately analyzing information was developed, and a manuscript was submitted for publication. The LIBS instrument sample cell is sealed in controlled inert atmosphere, which is an advantage for using humidity-sensitive samples and Be-contaminated samples. This aligns with the team’s effort to expand the capabilities of handling FLiBe and Becontaining materials in two newly installed glovebox units. Third, the team performed preliminary tribology tests for pebble graphite wear in contact with stainless steel in dry state and in molten salt at high temperature. These tests are needed to establish the baseline for the wear of pebble graphite by friction against metallic walls. The friction and wear of pebbles in the fluoride salt-cooled hightemperature reactor are expected to generate dust, which is a concern for other components’ properties and safe reactor operation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Plant Growth Study: Growth of Three Plant Species in 100-OL-1 Operable Unit Soils

Soil contamination from historical application of lead arsenate pesticides persists in the 100-OL-1 Operable Unit (OU) of the U.S. Department of Energy’s Hanford Site in Benton County, Washington. A remedial investigation used a portable X-ray fluorescence analyzer to estimate and map the concentrations of metals in surface soil in the 133 decision units comprising the OU. There is variability in lead and arsenic concentrations among the non-contiguous decision units, and an incomplete understanding of the ecological and human risks from soil contamination. While general screening criteria for lead are reported in literature, limited information is available on the impacts of heavy metals on site-specific plant and animal life. To address this information gap, a study on plant growth in Hanford soils was conducted using native bluegrass (Poa secunda), invasive cheatgrass (Bromus tectorum), and buttercrunch lettuce (Lactuca sativa). The latter is included because it is a common species used in plant growth studies. Soil samples were collected from a single general location within the 100-OL-1 OU, prepared, and categorized as having low, medium, or high concentrations of lead and arsenic, with the high concentration soil having concentrations of up to 3,400 and 790 mg/kg lead and arsenic, respectively. Additionally, a synthetic soil was prepared and used as a control, in accordance with standard plant growth protocols. Fifty-four seeds of each plant species were planted in each of the four soil types following the procedure outlined by the Washington State Department of Ecology. Germination rates and biomass measurements were recorded for 20 days. Both bluegrass and lettuce germination rates appeared to be reduced at the highest lead and arsenic concentrations (Pb: 3400 mg/kg, As: 790 mg/kg), while cheatgrass germination rates were unaffected. Total biomass for all species appeared to be related to the relative concentrations of lead and arsenic in the soil. Results of this growth study agree reasonably well with previous Hanford Site plant growth studies and provide additional data for assessing ecological risk at the Hanford Site.

54 ENVIRONMENTAL SCIENCES↗

Chapter 8: Life-Cycle Testing and Analysis

Prior to a spacecraft launch, program mission assurance standards dictate that the flight battery power system should comply with mission requirements under the intended operating conditions. Ground life cycle testing (LCT) combined with an analysis on the electrical power system (EPS) battery is an empirical method used to demonstrate compliance to satellite service life requirements. The LCT compliance method adopted by the aerospace industry is based on demonstrating a space battery's life expectancy as a part of battery qualification. Real-time cell and lithium-ion battery (LIB) LCT data are commonly used for model inputs to EPS power and energy balance analyses, in LIB reliability analysis estimates, and to support on-orbit spacecraft mission life extension opportunities. This chapter describes the LCT planning steps, process approach, and analysis techniques commonly used to qualify space LIB power systems.

accelerated aging↗

Development and Validation of a Simulation Testbed for the Intelligent Building Agents Laboratory (IBAL) Using TRNSYS

This paper documents the development and validation of a dynamic primary cooling and thermal storage system simulation testbed. The system simulation testbed, sIBAL, is based on the Intelligent Building Agents Laboratory (IBAL) at the National Institute of Standards and Technology (NIST), which is a research infrastructure and testbed for the development, evaluation, and demonstration of intelligent control algorithms. The sIBAL testbed developed in this project will serve as a virtual twin of the real facility for future control algorithm development. The details of the methodologies used to develop and validate the simulation testbed, which replicates the dynamic behaviors of the primary cooling and ice storage system in the IBAL facility, are presented. The simulation testbed was developed in TRNSYS using built-in component models and MATLAB functions to replicate the two water-cooled chillers, a thermal storage tank, pumps, valves and other components for four different operation modes. Experiments on IBAL components were designed and executed to generate experimental data for model development and verification of the simulation platform. The validation of the simulation results was carried out in two phases: 1) independent component simulations for the chillers and thermal storage tank, and 2) a combined testbed simulation of the entire hydronic system. Comparison of simulation results to the experimental data obtained from the IBAL facility showed errors within 1 °C for the temperatures outputs of both the chiller and the thermal storage model. The error is within an acceptable range for further intelligent control algorithms development. The findings from the study are summarized and presented along with areas where additional research is needed. In addition, data filtering procedures and model refinement measures utilized to improve the accuracy and accelerate the computation time of the simulation are presented.

cooling systems↗

Status of ICARUS NUMI Interaction Cross-Section Analysis

The ICARUS experiment, utilizing Liquid Argon Time Projection Chamber (LAr TPC) technology, has been installed at Fermilab in Chicago, Illinois, following its initial operation in Italy and subsequent refurbishment at CERN. ICARUS completed commissioning in June 2022. Currently, the experiment is in the phase of analyzing data from its two runs of physics data acquisition and gearing up for the third run. While its primary objective is to function as the far detector of the Short Baseline Neutrino program (SBN), seeking sterile neutrino signatures, ICARUS also offers diverse physics capabilities, including searches beyond the standard model and measurements of cross-sections. In addition to being exposed to the common Booster Neutrino (BNB) beamline, ICARUS also receives off-axis neutrinos from the Main Injector (NuMI) beam. Due to the off-axis angle between NuMI and ICARUS, coupled with contributions from both pion and kaon decays to neutrino fluxes, interactions of NuMI neutrinos within ICARUS can be detected over a range of several GeV in energy. These interactions present opportunities for crucial cross-section measurements and model tests within an energy range that overlaps both the SBN oscillation search and a portion of the DUNE spectrum. This poster presentation will delve into our efforts to conduct a muon-neutrino cross-section measurement, where the signal is defined by events with no pions produced in the final state of the interaction, along with some preliminary muon-neutrino inclusive measurements. Additionally, it will provide updates on the current status and future plans, including reconstruction, selection, and analysis procedures.

43 PARTICLE ACCELERATORS↗

High-Mileage Courier Fleet Vehicle Laboratory Battery Pack Testing

For one of each of the AVTA's plug-in hybrid electric vehicles, battery electric vehicles, and some hybrid electric vehicles tested in high-mileage courier fleets, the high-voltage traction battery packs were removed from the vehicle and tested at the beginning and end of fleet testing. For some vehicles, batteries also were tested at periodic intervals during fleet testing. Standard reference performance tests were conducted to characterize battery degradation over time. This dataset contains results from two or more rounds of battery tests for 21 distinct year/make/model vehicles (see reference ["INL Advanced Vehicle Testing Activity: On-road Logger and Laboratory Battery Pack Testing Vehicle List"](https://avt.inl.gov/sites/default/files/pdf/reports/DatasetVehicleList.pdf) for full list of vehicles). Each round of battery testing included the "Static Capacity Test" and the "Hybrid Pulse Power Characterization (HPPC) Test", conducted according to test procedures published in the United States Advanced Battery Consortium ["Battery Test Manual For Power-Assist Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=57), ["Battery Test Manual For Plug-In Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=168), and ["Electric Vehicle Battery Test Procedures Manual"](https://www.uscar.org/commands/files_download.php?files_id=5) prior to the time of testing. These tests were performed by Intertek Testing Services, North America. (This dataset will be shared by API; a small sample of the vehicle battery and test data has been extracted and is available for download while the API is being developed.)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗