Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “stage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

An Experimental Investigation of Fuel Staging In A Model Gas Turbine Combustor

Modern gas turbine engines are typically operated in a lean-premixed configuration in order to meet emissions requirements. Lean operation makes gas turbines more susceptible to combustion instability, which can cause catastrophic hardware failure if left unchecked. The spatially uneven distribution of fuel in a gas turbine combustor, known as fuel staging, is an effective way of suppressing instabilities. This dissertation examines the effect of both steady-state and transient fuel-staging in a model gas turbine combustor. First, the steady-state effect of fuel staging on nominally unstable operating conditions is examined. At 200 degrees Celsius and a bulk flow velocity of 26 m/s, the combustor undergoes self-excited instabilities when the equivalence ratio is between φ = 0.70 and φ = 0.74 when all nozzles are fueled equally. These instabilities are suppressed when the center nozzle equivalence ratio is increased to φ Staging = 0.85 and the outer nozzle equivalence ratio maintained at φ = 0.70 or when the global equivalence ratio is maintained at φ = 0.70 by increasing the center nozzle equivalence ratio to φ Staging = 0.74 and decreasing the outer nozzle equivalence ratio to φ Staging = 0.69. The staged p' RMS amplitudes are found to decrease with increasing equivalence ratio and the damping rates found to increase with increasing equivalence ratio. Next, axisymmetric fuel staging transients are conducted valve opening/closing timescales of 1, 16, 58, 4,000, and 10,000 ms, and equivalence ratios of φ staging = 0.75, 0.80, 0.85. It should be noted that these valve opening/closing timescales, referred to as τ Transient , differ from the actual fuel convection timescale that are summarized in Table 5.2. It is found that the combustor pressure fluctuation at the end of the transient strongly depends on staging equivalence ratio but not on τ Transient . Increasing the staging equivalence ratio decreased the staged- stable combustor pressure amplitude, similarly to the steady-state results. The staged-stable damping rate trends are insensitive to to τ Transient and increased with increasing staging equivalence ratio. The timescale of the transition, τ, is found to be sensitive to both τ Transient and the staging equivalence ratio. For a Modern gas turbine engines are typically operated in a lean-premixed configuration in order to meet emissions requirements. Lean operation makes gas turbines more susceptible to combustion instability, which can cause catastrophic hardware failure if left unchecked. The spatially uneven distribution of fuel in a gas turbine combustor, known as fuel staging, is an effective way of suppressing instabilities. This dissertation examines the effect of both steady-state and transient fuel-staging in a model gas turbine combustor. First, the steady-state effect of fuel staging on nominally unstable operating conditions is examined. At 200 degrees Celsius and a bulk flow velocity of 26 m/s, the combustor undergoes self-excited instabilities when the equivalence ratio is between φ = 0.70 and φ = 0.74 when all nozzles are fueled equally. These instabilities are suppressed when the center nozzle equivalence ratio is increased to φ Staging = 0.85 and the outer nozzle equivalence ratio maintained at φ = 0.70 or when the global equivalence ratio is maintained at φ = 0.70 by increasing the center nozzle equivalence ratio to φ Staging = 0.74 and decreasing the outer nozzle equivalence ratio to φ Staging = 0.69. The staged p' RMS amplitudes are found to decrease with increasing equivalence ratio and the damping rates found to increase with increasing equivalence ratio. Next, axisymmetric fuel staging transients are conducted valve opening/closing timescales of 1, 16, 58, 4,000, and 10,000 ms, and equivalence ratios of φ staging = 0.75, 0.80, 0.85. It should be noted that these valve opening/closing timescales, referred to as τ Transient , differ from the actual fuel convection timescale that are summarized in Table 5.2. It is found that the combustor pressure fluctuation at the end of the transient strongly depends on staging equivalence ratio but not on τ Transient . Increasing the staging equivalence ratio decreased the staged-stable combustor pressure amplitude, similarly to the steady-state results. The staged-stable damping rate trends are insensitive to to τ Transient and increased with increasing staging equivalence ratio. The timescale of the transition, τ, is found to be sensitive to both τ Transient and the staging equivalence ratio. For a Modern gas turbine engines are typically operated in a lean-premixed configuration in order to meet emissions requirements. Lean operation makes gas turbines more susceptible to combustion instability, which can cause catastrophic hardware failure if left unchecked. The spatially uneven distribution of fuel in a gas turbine combustor, known as fuel staging, is an effective way of suppressing instabilities. This dissertation examines the effect of both steady-state and transient fuel-staging in a model gas turbine combustor. First, the steady-state effect of fuel staging on nominally unstable operating conditions is examined. At 200 degrees Celsius and a bulk flow velocity of 26 m/s, the combustor undergoes self-excited instabilities when the equivalence ratio is between φ = 0.70 and φ = 0.74 when all nozzles are fueled equally. These instabilities are suppressed when the center nozzle equivalence ratio is increased to φ Staging = 0.85 and the outer nozzle equivalence ratio maintained at φ = 0.70 or when the global equivalence ratio is maintained at φ = 0.70 by increasing the center nozzle equivalence ratio to φ Staging = 0.74 and decreasing the outer nozzle equivalence ratio to φ Staging = 0.69. The staged p' RMS amplitudes are found to decrease with increasing equivalence ratio and the damping rates found to increase with increasing equivalence ratio. Next, axisymmetric fuel staging transients are conducted valve opening/closing timescales of 1, 16, 58, 4,000, and 10,000 ms, and equivalence ratios of φ staging = 0.75, 0.80, 0.85. It should be noted that these valve opening/closing timescales, referred to as τ Transient , differ from the actual fuel convection timescale that are summarized in Table 5.2. It is found that the combustor pressure fluctuation at the end of the transient strongly depends on staging equivalence ratio but not on τ Transient . Increasing the staging equivalence ratio decreased the staged- stable combustor pressure amplitude, similarly to the steady-state results. The staged-stable damping rate trends are insensitive to to τT Transient and increased with increasing staging equivalence ratio. The timescale of the transition, τ, is found to be sensitive to both τ Transient and the staging equivalence ratio. For a given τ Transient , the decay timescale decreased with increasing staging equivalence ratio. For 1, 16, and 58 ms transients, τ does not depend on τ Transient , though it does strongly depend on direction, where instability onset cases have longer and more variable τ than instability decay cases. The same dependence of τ on direction is seen for the 4,000 and 10,000 ms transients. However, unlike the short duration transients, τ does depend on τ Transient as would be expected. Phase space reconstruction shows the instability is a harmonic limit cycle with a single frequency. The instantaneous phase images shows the center region of the combustor goes out-of-phase first followed by the rest of the combustor. Finally, asymmetric fuel staging tests are conducted. It is found that non-axisymmetric staging can be as effective as axisymmetric staging, although small hardware variations between nozzles can affect the the minimum staging equivalence ratio that consistently suppresses the instability. These changes in the bifurcation equivalence ratio can make staging configurations appear less effective; however, both axisymmetric and non-axisymmetric staging configurations exhibit similar staged-stable p' RMS , damping rates, and instability transition times for equivalence ratios greater than the bifurcation equivalence ratio. Instantaneous phase images show similar instantaneous phase relationship structures in the staged nozzle (center or outer), suggesting that the instability suppression mechanism is similar in each case. This result is surprising given that the time-averaged flame shapes are very different between axisymmetric and non-axisymmetric staging configurations. The similar effectiveness of axisymmetric and non-axisymmetric staging in this geometry is attributed to the fact that the instability mode is a nominally axisymmetric plane wave. It is hypothesized that non-axisymmetric staging configurations will likely be more effective than axisymmetric staging configurations when the instability mode shape is asymmetric (such as a circumferential wave).

Culler, Wyatt↗

An Electron Microscopy Investigation of the Transient Stage Oxidation Products in an Fe-22Cr Alloy with Ce and La Additions Exposed to Dry Air at 1073 K (800 °C)

In this study, the effects of Ce (270 ppm) and La (120 ppm) mischmetal additions on the transient oxidation of an Fe-22Cr alloy were investigated. The oxidation process was imaged in situ using a confocal scanning laser microscope. The oxidation microstructures were studied by scanning electron microscopy, energy dispersive X-ray analysis, and transmission electron microscopy with the help of focused ion beam in situ lift-out specimen preparation. The Ce and La, referred to as reactive elements, were found in nonmetallic inclusion particles in the forms of oxides, sulfides, and phosphates. An affected zone formed around rare earth (RE)-containing inclusion particles at the alloy free surface during the transient oxidation. This zone consisted of an internal Cr-oxide formed beneath the particle as well as a thinner external oxide scale on the surface compared with the surroundings. The relation of this microstructure to oxidation kinetics is discussed. With time, the RE elements diffused into the scale from the RE particles on the alloy surface during the high-temperature exposure. A diffusion mechanism is presented to describe these observations.

01 COAL, LIGNITE, AND PEAT↗

Quality Assurance of 4D-CT Scan Techniques in Multicenter Phase III Trial of Surgery Versus Stereotactic Radiotherapy (Radiosurgery or Surgery for Operable Early Stage (Stage 1A) Non-Small-Cell Lung Cancer [ROSEL] Study)

Purpose: To determine the accuracy of four-dimensional computed tomography (4D-CT) scanning techniques in institutions participating in a Phase III trial of surgery vs. stereotactic radiotherapy (SBRT) for lung cancer. Methods and Materials: All 9 centers performed a 4D-CT scan of a motion phantom (Quasar, Modus Medical Devices) in accordance with their in-house imaging protocol for SBRT. A cylindrical cedar wood insert with plastic spheres of 15 mm (o15) and 30 mm (o30) diameter was moved in a cosine-based pattern, with an extended period in the exhale position to mimic the actual breathing motion. A range of motion of R = 15 and R = 25 mm and breathing period of T = 3 and T = 6 s were used. Positional and volumetric imaging accuracy was analyzed using Pinnacle version 8.1x at various breathing phases, including the mid-ventilation phase and maximal intensity projections of the spheres. Results: Imaging using eight CT scanners (Philips, Siemens, GE) and one positron emission tomography-CT scanner (Institution 3, Siemens) was investigated. The imaging protocols varied widely among the institutions. No strong correlation was found between the specific scan protocol parameters and the observed results. Deviations in the maximal intensity projection volumes averaged 1.9% (starting phase of the breathing cycle [o]15, R = 15), 12.3% (o15, R = 25), and -0.9% (o30, R = 15). The end-expiration volume deviations (13.4%, o15 and 2.5%, o30), were, on average, smaller than the end-inspiration deviations (20.7%, o15 and 4.5%, o30), which, in turn, were smaller than the mid-ventilation deviations (32.6%, o15 and 8.0%, o30). A slightly larger variation in the mid-ventilation origin position was observed (mean, -0.2 mm; range, -3.6-4.2) than in the maximal intensity projection origin position (mean, -0.1 mm; range, -2.5-2.5). The range of motion was generally underestimated (mean, -1.5 mm; range, -5.5-1). Conclusions: Notable differences were seen in the 4D-CT imaging protocols for SBRT among centers. However, the observed deviations in target volumes were generally small. They were slightly larger for the mid-ventilation phases and smallest for the end-expiration phases. Steps to optimize and standardize the 4D-CT scanning protocols for SBRT are desirable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Energy innovation in the US buildings sector: Setting the stage and mapping the future

Jared Langevin is a staff scientist at Lawrence Berkeley National Laboratory, where he leads modeling of US buildings sector innovation and its implications for energy demand, consumer costs, and the power grid. Eric Wilson is a senior research engineer in the Building Technologies and Sciences Center at the National Renewable Energy Laboratory (NREL). Much of his 15-year career at NREL has revolved around modeling and analysis of the US building stock. Jared and Eric co-led the development of a National Blueprint for buildings sector innovation while serving as advisors to the US Department of Energy’s Deputy Assistant Secretary for Buildings and Industry.

Langevin, Jared↗