Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometry data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

MS2Planner: improved fragmentation spectra coverage in untargeted mass spectrometry by iterative optimized data acquisition

Motivation: Untargeted mass spectrometry experiments enable the profiling of metabolites in complex biological samples. The collected fragmentation spectra are the metabolite’s fingerprints that are used for molecule identification and discovery. Two main mass spectrometry strategies exist for the collection of fragmentation spectra: data-dependent acquisition (DDA) and data-independent acquisition (DIA). In the DIA strategy, all the metabolites ions in predefined mass-to-charge ratio ranges are co-isolated and co-fragmented, resulting in multiplexed fragmentation spectra that are challenging to annotate. In contrast, in the DDA strategy, fragmentation spectra are dynamically and specifically collected for the most abundant ions observed, causing redundancy and sub-optimal fragmentation spectra collection. Yet, DDA results in less multiplexed fragmentation spectra that can be readily annotated. Results: We introduce the MS2Planner workflow, an Iterative Optimized Data Acquisition strategy that optimizes the number of high-quality fragmentation spectra over multiple experimental acquisitions using topological sorting. Our results showed that MS2Planner increases the annotation rate by 38.6% and is 62.5% more sensitive and 9.4% more specific compared to DDA. Availability and implementation MS2Planner code is available at https://github.com/mohimanilab/MS2Planner. The generation of the inclusion list from MS2Planner was performed with python scripts available at https://github.com/lfnothias/IODA_MS.

47 OTHER INSTRUMENTATION↗

Toward nanoscale molecular mass spectrometry imaging via physically constrained machine learning on co-registered multimodal data

Mass spectrometry imaging (MSI) plays a pivotal role in investigating the chemical nature of complex systems that underly our understanding in biology and medicine. Multiple fields of life science such as proteomics, lipidomics and metabolomics benefit from the ability to simultaneously identify molecules and pinpoint their distribution across a sample. However, achieving the necessary submicron spatial resolution to distinguish chemical differences between individual cells and generating intact molecular spectra is still a challenge with any single imaging approach. Here, we developed an approach that combines two MSI techniques, matrix-assisted laser desorption/ionization (MALDI) and time-of-flight secondary ion mass spectrometry (ToF-SIMS), one with low spatial resolution but intact molecular spectra and the other with nanometer spatial resolution but fragmented molecular signatures, to predict molecular MSI spectra with submicron spatial resolution. The known relationships between the two MSI channels of information are enforced via a physically constrained machine-learning approach and directly incorporated in the data processing. We demonstrate the robustness of this method by generating intact molecular MALDI-type spectra and chemical maps at ToF-SIMS resolution when imaging mouse brain thin tissue sections. This approach can be readily adopted for other types of bioimaging where physical relationships between methods have to be considered to boost the confidence in the reconstruction product.

97 MATHEMATICS AND COMPUTING↗

Using Skyline to Analyze Data-Containing Liquid Chromatography, Ion Mobility Spectrometry, and Mass Spectrometry Dimensions

Recent advances in ion mobility spectrometry (IMS) have illustrated its power in determining the structural characteristics of a molecule, especially when coupled with other separations dimensions such as liquid chromatography (LC) and mass spectrometry (MS). However, these three separation techniques together greatly complicate data analyses, making better informatics tools essential for assessing the resulting data. In this manuscript, Skyline was adapted to analyze LC-IMS-CID-MS data from numerous instrument vendor datasets and determine the effect of adding the IMS dimension into the normal LC-MS molecular pipeline. For the initial evaluation, a tryptic digest of bovine serum albumin (BSA) was spiked into a yeast protein digest at seven different concentrations, and Skyline was able to rapidly analyze the MS and CID-MS data for 38 of the BSA peptides. Calibration curves for the precursor and fragment ions were assessed with and without the IMS dimension. In all cases, addition of the IMS dimension removed noise from co-eluting peptides with close m/z values, resulting in calibration curves with greater linearity and lower detection limits. This study presents an important informatics development since to date LC-IMS-CID-MS data from the different instrument vendors is often assessed manually and cannot be analyzed quickly. Because these evaluations require days for the analysis of only a few target molecules in a limited number of samples, it is unfeasible to evaluate hundreds of targets in numerous samples. Thus, this study showcases Skyline’s ability to work with the multidimensional LC-IMS-CID-MS data and provide biological and environmental insights rapidly. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lead Slowing Down Spectrometry Analysis of Data from Measurements on Nuclear Fuel

Improved non-destructive assay of isotopic masses in used nuclear fuel would be valuable for nuclear safeguards operations associated with the transport, storage and reprocessing of used nuclear fuel. Our collaboration is examining the feasibility of using lead slowing down spectrometry techniques to assay the isotopic fissile masses in used nuclear fuel assemblies. We present the application of our analysis algorithms on measurements conducted with a lead spectrometer. The measurements involved a single fresh fuel pin and discrete 239Pu and 235U samples. We are able to describe the isotopic fissile masses with root mean square errors over seven different configurations to 6.35% for 239Pu and 2.7% for 235U over seven different configurations. Funding Source(s):

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Apodization Specific Fitting for Improved Resolution, Charge Measurement, and Data Analysis Speed in Charge Detection Mass Spectrometry

Short-time Fourier transforms with short segment lengths are typically used to analyze single ion charge detection mass spectrometry (CDMS) data either to overcome effects of frequency shifts that may occur during the trapping period or to more precisely determine the time at which an ion changes mass or charge, or enters an unstable orbit. The short segment lengths can lead to scalloping loss unless a large number of zero-fills are used, making computational time a significant factor in real-time analysis of data. Apodization specific fitting leads to a 9-fold reduction in computation time compared to zero-filling to a similar extent of accuracy. This makes possible real-time data analysis using a standard desktop computer. Rectangular apodization leads to higher resolution than the more commonly used Gaussian or Hann apodization and makes it possible to separate ions with similar frequencies, a significant advantage for experiments in which the masses of many individual ions are measured simultaneously. Equally important is a >20% increase in S/N obtained with rectangular apodization compared to Gaussian or Hann, which directly translates to a corresponding improvement in accuracy of both charge measurements and ion energy measurements that rely on the amplitudes of the fundamental and harmonic frequencies. Finally, combined with computing the fast Fourier transform in a lower-level language, this fitting procedure eliminates computational barriers and should enable real-time processing of CDMS data on a laptop computer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An optimized approach and inflation media for obtaining complimentary mass spectrometry-based omics data from human lung tissue

Human disease states are biomolecularly multifaceted and can span across phenotypic states, therefore it is important to understand diseases on all levels, across cell types, and within and across microanatomical tissue compartments. To obtain an accurate and representative view of the molecular landscape within human lungs, this fragile tissue must be inflated and embedded to maintain spatial fidelity of the location of molecules and minimize molecular degradation for molecular imaging experiments. Here, we evaluated agarose inflation and carboxymethyl cellulose embedding media and determined effective tissue preparation protocols for performing bulk and spatial mass spectrometry-based omics measurements. Mass spectrometry imaging methods were optimized to boost the number of annotatable molecules in agarose inflated lung samples. This optimized protocol permitted the observation of unique lipid distributions within several airway regions in the lung tissue block. Laser capture microdissection of these airway regions followed by high-resolution proteomic analysis allowed us to begin linking the lipidome with the proteome in a spatially resolved manner, where we observed proteins with high abundance specifically localized to the airway regions. We also compared our mass spectrometry results to lung tissue samples preserved using two other inflation/embedding media, but we identified several pitfalls with the sample preparation steps using this preservation method. Overall, we demonstrated the versatility of the inflation method, and we can start to reveal how the metabolome, lipidome, and proteome are connected spatially in human lungs and across disease states through a variety of different experiments.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of Aerosol Mixing State Classes in the GISS Modele-matrix Climate Model Using Single-particle Mass Spectrometry Measurements

Aerosol particles in the atmosphere are composed of multiple chemical species. The aerosol mixing state, which describes how chemical species are mixed at the single-particle level, provides critical information on microphysical characteristics that determine the interaction of aerosols with the climate system. The evaluation of mixing state has become the next challenge. This study uses aerosol time-of-flight mass spectrometry (ATOFMS) data and compares the results to those of the Goddard Institute for Space Studies modelE-MATRIX (Multiconfiguration Aerosol TRacker of mIXing state) model, a global climate model that includes a detailed aerosol microphysical scheme. We use data from field campaigns that examine a variety of air mass regimens (urban, rural, and maritime). At all locations, polluted areas in California (Riverside, La Jolla, and Long Beach), a remote location in the Sierra Nevada Mountains (Sugar Pine) and observations from Jeju (South Korea), the majority of aerosol species are internally mixed. Coarse aerosol particles, those above 1 micron, are typically aged, such as coated dust or reacted sea-salt particles. Particles below 1 micron contain large fractions of organic material, internally-mixed with sulfate and black carbon, and few external mixtures. We conclude that observations taken over multiple weeks characterize typical air mass types at a given location well; however, due to the instrumentation, we could not evaluate mass budgets. These results represent the first detailed comparison of single-particle mixing states in a global climate model with real-time single-particle mass spectrometry data, an important step in improving the representation of mixing state in global climate models.

climate models↗

malbacR: A Package for Standardized Implementation of Batch Correction Methods for Omics Data

Mass spectrometry is a powerful tool for identifying and analyzing small molecules, such as metabolites and lipids, in com-plex biological samples. Liquid chromatography and gas chromatography mass spectrometry studies quite commonly in-volve large numbers of samples, which can require significant time for sample preparation and analyses. To accommodate such studies, the samples are commonly split into batches. Inevitably, variations in sample handling, temperature fluctua-tion, imprecise timing, column degradation and other factors result in systematic errors or biases of the measured abundances between the batches. Numerous methods are available via R packages to assist with batch correction for small molecule om-ics data; however, since these methods were developed by different research teams, the algorithms are available in separate R packages, each with different data input and output formats. We introduce the malbacR package which consolidates eleven common batch effect correction methods for small molecule omics data into one place so users can easily implement and compare: pareto scaling, power scaling, range scaling, ComBat, EigenMS, NOMIS, RUV-random, QC-RLSC, WaveI-CA2.0, TIGER, and SERRF. The malbacR package standardizes data input and output formats across these batch correction methods. The package works in conjunction with the pmartR package, allowing users to seamlessly include batch effect cor-rection in a pmartR workflow without needing any additional data manipulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Resolution Mass Spectrometry Quantification: Impact of Differences in Data Processing of Centroid and Continuum Data

High-resolution mass spectrometry (HRMS) in full scan mode acquires all ions present in the sample of interest offering a lot of qualitative information. This, in combination with the improved performance of the new generation HRMS systems, triggers more (bio) analysts to switch from triple quad MS systems to HRMS for quantitative analysis. Quantitative processing of HRMS data is performed based on narrow mass extraction windows rather than on nominal mass product ion chromatograms (SRM or MRM). Optimal processing of HRMS data requires different considerations and software tools and can have an impact on data processing and final results. The selection of centroid versus continuum/profile data for processing, selection of the optimal narrow mass extraction window, using theoretical versus measured accurate mass for the extraction of the ion chromatograms as well as differences in calculations and data handling residing in the different vendor software packages are tackled in the presented manuscript. These differences are illustrated on HRMS data acquired for the same plasma samples on three different platforms, i.e., a Sciex QToF, a Waters QToF, and a Thermo Orbitrap system, and processed in four different software packages, i.e., Sciex Analyst® TF, Waters Masslynx, Waters Unifi, and Thermo Xcalibur. The impact of these differences on quantitative HRMS performance was evaluated on calibration curves of eight small molecule compounds in plasma using four different ways of processing. Simple guidelines are provided for the selection of an optimal mass extraction window for continuum and centroided data. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tile-Based Fisher Ratio Analysis of Comprehensive Two-Dimensional Gas Chromatography Time-of-Flight Mass Spectrometry (GC × GC – TOFMS) Data using a Null Distribution Approach

Multi-dimensional chromatographic instrumentation produces information-rich, and chemically complex data containing meaningful chemical signals and/or chemical patterns. Two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC × GC – TOFMS) is a prominent instrumental platform that has been applied extensively for discovery-based experimentation, where samples are sufficiently volatile or amenable to derivatization. Use of GC × GC – TOFMS and associated data analysis strategies aim to uncover meaningful chemical signals or chemical patterns. However, for complex samples, meaningful chemical information is often buried in a background of less meaningful chemical signal and noise. In this report, we utilize the tile-based F-ratio software in concert with the standard addition method by spiking non-native chemicals into a diesel fuel matrix at low concentrations. While the previous work studied the concentration range of 100-1000 ppm, the current study focuses on the 0 ppm to 100 ppm analyte spike range. This study demonstrates the sensitivity and selectivity of the tile-based F-ratio software for discovery of true positives in the non-targeted analysis of a chemically complex and analytically challenging sample matrix. By exploring the low concentration spike levels, we gain a better understanding of the limit of detection (LOD) of the tile-based F-ratio software with GC × GC – TOFMS data.

Parsons, Brendon A.↗

Autonomous Science: Simulated Solar System Mission to Enceladus, Icy Ocean Moon of Saturn

Future NASA missions to icy ocean worlds such as Europa, Titan, or Enceladus will collect mass spectrometry (MS) data from exospheres, atmospheres, and plume volatiles to assess their geochemistry and potential for microbial life1. These remote missions face challenges related to limited bandwidth, communication, and power, highlighting the need for science autonomy2 to prioritize data for timely downlink. We extend our previous work on machine learning (ML) biosignature detection from isotope ratio mass spectrometry (IRMS) data to distributed systems missions (DSM) by incorporating the ML and autonomous data quality control and prioritization code into an onboard decision-making platform. We use simulated orbital telemetry for eight orbiters around Enceladus with a mothership to illustrate an automated biosignature and novel seawater chemistry detection with data prioritization from MS analyses of volatile CO2.

Conor Williams↗

Normalization and missing value imputation for label-free LC-MS analysis

Shotgun proteomic data are affected by a variety of known and unknown systematic biases as well as high proportions of missing values. Typically, normalization is performed in an attempt to remove systematic biases from the data before statistical inference, sometimes followed by missing value imputation to obtain a complete matrix of intensities. Here we discuss several approaches to normalization and dealing with missing values, some initially developed for microarray data and some developed specifically for mass spectrometry-based data.

Environmental Molecular Sciences Laboratory↗

Carbon dioxide (CO2) flux, amplicon sequencing and liquid chromatography–mass spectrometry (LC-MS) data for pyrogenic organic matter (PYOM) amended soil incubations in lab, Madison, WI, 2021-22

This dataset comprises soil-pyrogenic organic matter (PyOM) incubation experiments conducted in a laboratory setting. The focus was on measuring carbon dioxide (CO2) flux emitted in the headspace of incubation jars over a one-month period. The aim was to estimate carbon mineralization from two different carbon fractions in PyOM, as well as carbon mineralization from soil organic carbon (SOC). Bacterial and fungal community profiles were tracked at various time points during the incubation to observe changes in the overall community and specific responders to PyOM. LC-MS analysis of soil samples was also performed to monitor changes in the soil's chemical composition.The provided dataset includes processed CO2 flux measurements obtained from the Picarro-multiplexer measurement setup for each sample incubation jar. This data is available in the "CO2Flux.csv" file. Additionally, the dataset includes CO2 flux data partitioned to estimate mean carbon mineralization from the two PyOM carbon fractions, bulk PyOM, and SOC. The cumulative carbon mineralization data is provided in "cml_respired.csv," while the rate of carbon mineralization data is in "rate_respired.csv." The file "cml_respired_lastcyc.csv" contains cumulative carbon mineralization data for the PyOM carbon fractions, bulk PyOM, and SOC throughout the entire incubation period.For the LC-MS analysis, the raw data can be found in the "20220721_NZ_PeakHeights_FinalAnalysis.csv" file, while sample metadata is provided in "20220721_NZpilot_Metadata.csv". Processed LC-MS data is available in the file "20220721_NZ_FINAL_msdat_sub3.csv". Lastly, the dataset includes the relative abundance data for bacterial genera that exhibited a significant positive response to the addition of PyOM produced at 350 degrees Celsius, which can be found in "resp_genera_350.csv".

54 ENVIRONMENTAL SCIENCES↗

Infrared spectrometry studies: Spectral digital data acquisition system (1971 version)

The construction of the Stanford Spectral Digital Data Acquisition System is described. The objective of the system is to record both the spectral distribution of incoming radiation from the rock samples measured by the spectroradiometer (Exotech Model 10-34 Circular Variable Filter Infrared Spectroradiometer) together with other weather information. This system is designed for both laboratory and field measurement programs. The multichannel inputs (8 channels) of the system are as follows: Ch 1 the Spectro-radiometer, Ch 2 the radiometer (PRT-5), and Ch 3 to Ch 8 for the weather information. The system records data from channel 1 and channel 2 alternately for 48 times, before a fast sweep across the six weather channels, to form a single scan in the scan counter. The operation is illustrated in a block diagram, and the theory of operation is described. The outputs are written on a 7-track magnetic tape with IBM compatible form. The format of the tape and the playback computer programs are included. The micro-pac digital modules and a CIPHER model 70 tape recorder (Cipher Data Products) are used. One of the major characteristics of this system is that it is externally clocked by the spectroradiometer instead of taking data at intervals of various wavelengths by using internal-clocking.

Lu, L.↗

Refining PeakDecoder Version 2

Novel computational tools for processing multidimensional mass spectrometry (MS) data are necessary to enable deeper and automated detection and quantification of metabolites in complex backgrounds. Multidimensional MS data includes measurements from liquid chromatography (LC) and ion mobility spectrometry (IM) separations, and precursor and fragment ion spectra collected in data-independent acquisition (DIA) mode. PeakDecoder is an artificial intelligence (AI)-based software that enables automated interpretation of this kind of data to identify and quantify individual metabolites in complex mixtures. The goal of this project was to improve and re-implement PeakDecoder in a better suited programming language to enable its commercialization.

97 MATHEMATICS AND COMPUTING↗