Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “solar interconnection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

SEIN: Breaking Barriers Resilient Energy System Analysis [Slides]

The Solar Energy Innovation Network (SEIN) is a collaborative research program that supports multi-stakeholder teams in researching and sharing solutions to real-world challenges associated with solar energy adoption. The Breaking Barriers project was selected to participate in the Solar Energy Innovation Network, Round 2, and was led by Groundswell, a D.C.-based clean energy project developer. The Breaking Barriers team included Partnership for Southern Equity, Atlanta University Center campus facility managers and professors, the City of Atlanta's Neighborhood Planning Unit T, and Georgia Power Company. The project aimed to design and construct innovative urban energy resiliency hubs integrating microgrid technology, solar generation, and energy storage in Atlanta colleges and communities. The hubs will help these historically Black colleges and universities (HBCUs) and the energy-burdened broader community in West Atlanta be more resilient, in addition to informing new course curricula at Atlanta University Center campuses. With many possible options for the system's battery size, the Breaking Barriers team needed insight into the relationships between BESS size, economic performance, and resilience at Spelman College's Manley Center. These insights are crucial for entering procurement negotiations with project developers, establishing resilience capabilities that the HBCU campuses can plan around, and guiding the team's fundraising targets. This analysis includes estimates of PV and battery performance, costs, savings, and resilience for multiple battery sizes. In order to provide power during a grid outage, the resilient energy system also needs to be connected to the Manley Center in a safe and island-able manner (electrically isolated from the grid). Analysis of potential electrical configurations and estimated setup costs is key to successfully entering a required interconnection agreement with Georgia Power, as well as informing requests for engineering firms to construct the system. This analysis includes conceptual options and rough order of magnitude cost estimates for electrically interconnecting the resilient energy system to the Manley Center and the grid. The Breaking Barriers team used this analysis to select preferred system characteristics and design for the resilient energy system.

14 SOLAR ENERGY↗

Queued Up: Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2022 [Slides]

Proposed large-scale electric generation and storage projects must apply for interconnection to the bulk power system via interconnection queues. While most projects that apply for interconnection are not subsequently built, data from these queues nonetheless provide a general indicator for mid-term trends in developer interest. Berkeley Lab compiled and analyzed data from all seven ISOs/RTOs in concert with 35 non-ISO utilities, representing an estimated 85% of all U.S. electricity load. We include all "active" projects in these generation interconnection queues through the end of 2022, as well as data on "operational" and "withdrawn" projects where those data are available. We find that the amount of new electric capacity in these queues is growing dramatically, with over 2,000 gigawatts (GW) of total generation and storage capacity now seeking connection to the grid (over 95% of which is for zero-carbon resources like solar, wind, and battery storage). Solar (947 GW) and battery storage (~680 GW) are – by far – the fastest growing resources in the queues; combined they accounted for over 80% of new capacity entering the queues in 2022. Substantial wind (300 GW) capacity is also seeking interconnection, 38% of which is for offshore projects (113 GW). In total, about 1,250 GW of zero-carbon generating capacity is currently seeking transmission access, as is 82 GW of natural gas capacity. Hybrids projects (co-locating multiple generation and/or storage types) comprise a large – and increasing – share of proposed projects, particularly in CAISO and the non-ISO West. 457 GW of solar hybrids (primarily solar+battery) and 24 GW of wind hybrids are currently active in the queues; over half of battery storage in the queues is paired with generation. However, much of this proposed capacity will be withdrawn from the queues and not built. Among a subset of queues for which data are available, only 21% of the projects (and 14% of capacity) seeking connection from 2000 to 2017 have been built as of the end of 2022. Additionally, interconnection wait times are on the rise: The typical duration from connection request to commercial operation increased from <2 years for projects built in 2000-2007 to nearly 4 years for those built in 2018-2022 (with a median of 5 years for projects built in 2022).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exploring sustainable electricity system development pathways in South America’s MERCOSUR sub-region

South America has abundant natural water and energy resources, and exploiting these resources to achieve a clean energy future is central to the continent’s economic and sustainable development objectives for the next several decades. Designing pathways to achieving this clean energy future requires better understanding the structural, techno-economic, and policy forces that may influence the future development of the electricity sector in the region. Here, we focus on an interconnected electricity system of five South American countries – Argentina, Brazil, Chile, Paraguay, and Uruguay – which represent major electricity generation, consumption, and trade dynamics in the region. We explore the implications of various forces that could shape the future composition of the power sector in the sub-region, including: evolving renewable energy cost and performance, natural gas prices, cross-border interconnection facilities, early retirement of installed hydropower, and different decarbonization goals. We use a model framework based on a power system planning platform (GridPath) to co-optimize investment and operations of generation, storage, and transmission facilities out to 2050. Our results in a Reference scenario indicate that the electricity system can maintain a relatively clean energy portfolio by leveraging existing hydropower capacity and integrating increasingly cost-competitive wind and solar power. However, dependence on natural gas in the region is likely to remain high. A low-carbon electricity system can cost-effectively be achieved through policy interventions (e.g., renewable portfolio standards) and by diversifying investments in wind, solar, battery storage, and some new hydropower capacity. We also find that existing hydropower is critical for maintaining reliable future grid operations. Enhanced regional electricity trade, mostly based on existing interconnection capacities with nominal investment in new transmission, can significantly benefit the clean energy transition in the region.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Regional Inertia Estimation Using Actual Event Measurements: Florida Case

As inverter-based resources’ integration in power grids increases, their uneven distribution across the electrical network leads to the formation of local regions that are weakly coupled to the larger interconnection. This signifies the necessity of regional frequency dynamics investigation and analyzing various inertia metrics. This paper presents a practical methodology for estimating regional rate-of-change of frequency (RoCoF) using actual event recordings, which is then used to evaluate regional inertia. Florida (FL) is selected as the region of interest due to its distinct regional frequency dynamics and the rising levels of solar generation. We identify and analyze confirmed events from 2017 to 2024 that occurred in FL. The results indicate that FL contributes about 14% to the total inertia of the US Eastern Interconnection, which approximately matches its share of generation capacity. Results also highlight seasonal fluctuations in energy generation, which play a significant role in influencing inertia and thus the RoCoF levels. This emphasizes the importance of estimating regional inertia to enhance grid operations for a future that focuses on distributed generation.

Dulal, Saurav [University of Tennessee, Knoxville ↗

Ribbons Affect Movement of Cracked Solar Cells [Poster]

Cracking of crystalline silicon photovoltaic cells remains a challenging topic in accurately assessing the long-term reliability and performance of affected modules. Cells can be damaged in every stage throughout the lifetime of a photovoltaic module, ranging from manufacturing, transportation, and installation to operation. Initially, the metallization can be able to bridge the gap of fractured cells and keep individual cell fragments electrically connected. However, photovoltaic modules and cells experience thermo-mechanical stresses during operation from temperature changes and pressure cycles of wind and snow loads. This causes the cell fragments to move, which, in turn, can lead to the wear out of the metallization and, consequently, to power loss or a safety hazard. The rate at which this degradation mechanism proceeds is currently unknown. Hence, in this work, we quantify the cell fragment movement of polycrystalline and monocrystalline mini-modules. By using digital image correlation, we were able to extract the normal crack opening and tangential sliding distances of adjacent cell fragments during heating of the mini-modules. Those distances are essential to develop wear-out models for the metallization and determine the rate of the degradation mechanism. We found that the interconnect technology has a significant impact on the direction and quantity of the cell fragment movements.

14 SOLAR ENERGY↗

Understanding Community Microgrids

Increasing need for distribution circuit reliability and resilience prompt a clearer understanding of community microgrid interconnection and operational requirements. While customer-owned, behind-the-meter microgrid implementation is not always simple, increasing demand for reliability has commercialized many installation approaches. This rapid commercialization has broadened industry understanding of single-customer microgrid integration. Moreover, off-grid behaviors of such microgrids are not required to meet utility standard interconnection requirements. However, multi-customer community microgrids (utility- or third-party operated), are less well explored and introduce more complex design and operational challenges. The control of DER along with distribution automation devices, unmanned operation, protection coordination, and other aspects makes community microgrids challenging to implement and operate in both on-grid and off-grid modes. This whitepaper is a technical primer for understanding community microgrids. It provides a foundation for understanding the components, configurations, design, and operational considerations for community microgrids.

14 SOLAR ENERGY↗

Hybrid Power Plants: Status of Operating and Proposed Plants, 2022 Edition [Slides]

Falling battery prices and the growth of variable renewable generation are driving a surge of interest in “hybrid” power plants that combine, for example, wind or solar generating capacity with co-located batteries. While most of the current interest involves pairing photovoltaic (PV) plants with batteries, other types of hybrid or co-located plants with wide-ranging configurations have been part of the U.S. electricity mix for decades. This annually updated briefing tracks and maps existing hybrid or co-located plants across the United States while also synthesizing data mined from power purchase agreements (PPAs) and generation interconnection queues to shed light on near- and long-term development pipelines. The scope includes co-located hybrid plants that pair two or more generators and/or that pair generation with storage at a single point of interconnection, and full hybrids that feature co-location and co-control. The focus is on plants with one megawatt (MW) or more of capacity; smaller (often behind-the-meter) projects are also increasingly common, but are not included in this data synthesis. Key findings from the latest briefing include: -At the end of 2021, there were nearly 300 hybrid plants (>1 MW) operating across the United States, totaling nearly 36 gigawatts (GW) of generating capacity and 3.2 GW/8.1 GWh of energy storage. PV+storage plants are by far the most common, dominating in terms of plant number (140), storage capacity (2.2 GW/7.0 GWh), storage:generator ratio (53%), and storage duration (3.2 hours). But there are nearly twenty other hybrid plant configurations as well, including several different fossil hybrid categories (each dominated by the fossil component) as well as wind+storage, wind+PV, wind+PV+storage, geothermal+PV, and others. -Last year was a breakout year for PV+storage hybrids in particular: 67 of the 74 hybrids added in 2021 were PV+storage. By the end of 2021, there were more GW of battery capacity installed in PV+storage hybrids (2.2 GW) than as standalone storage plants (1.8 GW). The difference is even starker in energy terms, with PV+storage plants hosting twice as much battery capacity as standalone storage plants (7 GWh vs. 3.5 GWh, respectively). Much of the battery capacity added in hybrid form in 2021 was a battery retrofit to a pre-existing PV plant. -Data on plants under development from the interconnection queues of all seven ISOs/RTOs plus 35 individual utilities suggest that these hybridization trends are likely to continue. At the close of 2021, there were more than 670 GW of solar plants in the nation’s queues; 285 GW (~42%) of this capacity was proposed as a hybrid, most typically pairing PV with battery storage (PV+storage represented nearly 90% of all hybrid capacity in the queues). For wind, 247 GW of capacity sat in the queues, with 19 GW (~8%) proposed as a hybrid, again most-often pairing wind with storage (wind+storage represented ~4% of all hybrid capacity in the queues). Meanwhile, nearly half of all storage in the queues is estimated to be part of a hybrid plant. While many of these proposed plants will not ultimately reach commercial operations, the depth of interest in hybrid plants—especially PV+storage—is notable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Benefit Analysis of Long-Duration Energy Storage in Power Systems with High Renewable Energy Shares

The integration of high shares of variable renewable energy raises challenges for the reliability and cost-effectiveness of power systems. The value of long-duration energy storage, which helps address variability in renewable energy supply across days and seasons, is poised to grow significantly as power systems shift to larger shares of variable generation such as wind and solar. This study explores the system-level services and associated benefits of long-duration energy storage on the 2050 Western Interconnection (WI). The operation of the future WI system with 85% renewable penetration is simulated using a two-stage production cost model. The impact of long duration energy storage on systemwide operations is examined for the 2050 WI system, using a range of round-trip efficiencies corresponding to four different energy storage technologies. The analysis projects the energy storage dispatch profile, system-wide production cost savings (from both diurnal and seasonal operation), and impacts on generation mix, and change in renewable generation curtailment.

25 ENERGY STORAGE↗

Barriers to Balcony Solar and Plug-In Distributed Energy Resources in the United States

Plug-in distributed energy resources (DERs), such as balcony solar, backfeed power to the home through a standard plug. These systems may represent the future of residential solar and storage, particularly as recent net metering policies have reduced the economic appeal of rooftop solar. While plug-in DERs have seen widespread success in Europe, their U.S. market is stagnant. This paper reviews the technical, interconnection, and regulatory barriers hindering the adoption of plug-in DERs. We first discuss the technical barriers, which include touch safety, breaker masking, and bidirectional ground-fault circuit interrupters. We then examine utility perspectives on plug-in DERs and strategies for navigating interconnection challenges. Finally, we discuss regulatory hurdles related to UL standards and the National Electrical Code.

Gerber, Daniel L. (ORCID:0000000219720679)↗

Background Information on the Power Quality Requirements in IEEE Std 1547-2018

The revised Institute of Electrical and Electronics Engineers (IEEE) 1547-2018, Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces, was published in April 2018. This standard is one of the foundational documents in the United States needed for integrating distributed energy resources (DERs), including solar energy systems, and energy storage systems with the electric distribution grid. The revised standard contains 11 chapters (clauses) and 8 annexes that comprise 136 pages. The revision is significantly different from the 2003 version, and it contains new concepts and new technical requirements. Each clause specifies information or requirements that apply to certain aspects that are important to the interconnection of DERs to the electric power system. Implementing the requirements necessitates a careful study of the underlying technical concepts and requires appropriate information to calculate relevant settings and configurations. This document provides informative material on the requirements related to electrical power quality in IEEE Std 1547-2018, with the intent to equip the reader with basic knowledge and background information to improve understanding and use of the requirements specified.

14 SOLAR ENERGY↗

Sharing the Sun: Community Solar Deployment and Subscriptions (As of January 2026)

The community solar market analysis presented here is based primarily on data collected through Sharing the Sun, an initiative of the National Community Solar Partnership+ (NCSP+). Sharing the Sun data collection and analysis are conducted by the National Laboratory of the Rockies (NLR) as part of its support for implementation of NCSP+. NLR first released a dataset of community solar projects in 2018 and updates it biannually. The January 2026 dataset, data collection methodology, and all the previous datasets are available from NLR's Data Catalog: https://data.nlr.gov/submissions/244. The dataset presents project-level information including location, capacity, operating utility, and year of interconnection. The dataset is created from multiple data sources such as utility data, public utility commissions, project developer websites, media releases, primary data collection by NLR, and data provided by developers under nondisclosure agreements. This presentation builds on a previous analysis of the community solar project dataset, Sharing the Sun: Community Solar Deployment and Subscriptions (as of June 2024). Dr. Gabriel Chan and his team at the University of Minnesota contribute to this effort. NCSP+ is led and funded by U.S. Department of Energy's Integrated Energy Systems Office (IESO).

14 SOLAR ENERGY↗

Queued Up: Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2021 [Slides]

Proposed large-scale electric generation and storage projects must apply for interconnection to the bulk power system via interconnection queues. While most projects that apply for interconnection are not subsequently built, data from these queues nonetheless provide a general indicator for mid-term trends in developer interest. Berkeley Lab compiled and analyzed data from all seven ISOs/RTOs in concert with 35 non-ISO utilities, representing an estimated 85% of all U.S. electricity load. We include all "active" projects in these generation interconnection queues through the end of 2021, as well as data on "operational" and "withdrawn" projects where those data are available. We find that the amount of new electric capacity in these queues is growing dramatically, with over 1,400 gigawatts (GW) of total generation and storage capacity now seeking connection to the grid (over 90% of which is for zero-carbon resources like solar, wind, and battery storage). Solar (676 GW) and battery storage (~420 GW) are – by far – the fastest growing resources in the queues; combined they accounted for nearly 85% of new capacity entering the queues in 2021. Substantial wind (247 GW) capacity is also seeking interconnection, 31% of which is for offshore projects (77 GW). In total, about 930 GW of zero-carbon generating capacity is currently seeking transmission access, as is 74 GW of natural gas capacity. Hybrids now comprise a large – and increasing – share of proposed projects, particularly in CAISO and the non-ISO West. 286 GW of solar hybrids (primarily solar+battery) and 19 GW of wind hybrids are currently active in the queues; nearly half of battery storage in the queues is paired with generation. However, much of this proposed capacity will be withdrawn from the queues and not built. Among a subset of queues for which data are available, only 23% of the projects seeking connection from 2000 to 2016 have subsequently been built. Completion percentages appear to be declining and are even lower for wind and solar than other resources. Additionally, wait times are on the rise: for the regions with available data, the typical duration from connection request to commercial operation increased from ~2.1 years for projects built in 2000-2010 to ~3.7 years for those built in 2011-2021.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Shifts in hydropower operation to balance wind and solar will modify effects on aquatic biota

To avoid negative consequences to freshwater biota from climate change, society must complete the transition from fossil to renewable electricity sources. However, temporal patterns in hydropower generation (and flow releases that affect aquatic biota) may change with increased wind and solar penetration. We used power cost modeling to characterize current and future within-day and seasonal patterns in hydropower generation across the Eastern Interconnection in a wet and a dry year. Compared to the baseline, future hydropower generation across the grid decreased during the day and increased before dawn and after dusk. At a project level, such a pattern would suggest 'double peaking' operation (up- and down-ramping before dawn and after dusk, with lower releases midday). Variation in generation was higher in wet years than dry years, foreshadowing possible flow constraints on hydropower flexibility. At the grid scale, projected ramping rates were higher in all seasons. A review of the ecological literature suggests that these changes would shift the timing of invertebrate drift and elevate the risk of nest scouring during up-ramping and the risk of stranding or dewatering during down ramping. Thermal conditions may be moderated by increased ramping. Strategies for adapting to future shifts in the renewable portfolio range from re-regulation in reservoir cascades to providing flow refuge (structures and vegetation) below individual projects. Coordinated basin-scale operation can distribute peaking operation to maintain grid support while restricting local ramping at critical ecological times. In addition, research to design hybrid renewable systems that add battery storage is needed to understand how we can mitigate future risks to aquatic communities while promoting the use of renewable energy. This study, which is among the first to examine ecological side-effects of the shift to renewable energy in freshwater ecosystems, lays out a path toward understanding and navigating changes to flow regimes under the energy transition.

54 ENVIRONMENTAL SCIENCES↗

An Overview of Issues Related to IEEE Std 1547-2018 Requirements Regarding Voltage and Reactive Power Control

The revised Institute of Electrical and Electronics Engineers (IEEE) 1547 Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces (IEEE Std 1547-2018) was published in April 2018. This standard is one of the foundational documents in the United States needed for integrating distributed energy resources (DERs), including solar energy systems, with the electric distribution grid. The revised standard contains 11 chapters (clauses) and 8 annexes that comprise 136 pages. The revision is significantly different from the 2003 version, and it contains new concepts and new technical requirements. Each clause specifies information or requirements that apply to certain aspects important to the interconnection of DERs to the electric power system. Implementing the requirements necessitates a careful study of the underlying technical concept and requires the appropriate information required to calculate relevant settings and configurations. Various stakeholders have different roles in implementing the standard, and portions of the standard are directed toward a specific audience who must possess specialized information and technical training to use and apply the requirements. This document aims to (1) summarize a specific portion of the standard as concisely as possible and (2) provide the reader with introductory knowledge and information to support the utilization of the requirements.

14 SOLAR ENERGY↗

Bilevel Nodal Behind-the-meter Solar Disaggregation Under Unexpected Extreme Weather Conditions

As the power grid undergoes significant paradigm shift due to the increasing penetration of renewable generation, the ever-growing installation of behind-the-meter (BTM) solar generation in the power grid also has a significant impact on nodal loads, posing challenges on transmission operators. Furthermore, increasing frequent and severe extreme weather events intertwine with ubiquitous BTM solar generations and have amplified the challenges of accurately model nodal load profiles, especially under the lack of ground-truth information for verification. To tackle these challenges, this paper introduces a bilevel model that utilizes year-long data (e.g., proxy solar, zonal load, and individual node load profiles) to disaggregate metered profiles into actual demand and BTM solar generation at each transmission node. The proxy solar not only scales the BTM solar generation of individual nodes but also create a compensation term for enhancing performance on days with unexpected extreme weather events. The proposed algorithm is validated with real-world PJM Interconnection data during unexpected events like the recent Winter Storm Elliott. For quantitative evaluations, a novel Score error is introduced, which is based on mean percentages and load scales and offers a universal assessment method suitable for all nodes and different data formats (e.g., normalized or raw values).

behind-the-meter solar, load disaggregations, load↗

Perovskite/Silicon Tandem Solar Cells: Insights and Outlooks

Organic-inorganic hybrid perovskites have been widely used in silicon-based tandem solar cells for their advantages of tunable bandgap, high light absorption coefficient, and high power conversion efficiency (PCE). However, the maximum PCE of perovskite/silicon tandem solar cells (PSTSCs) is still below the theoretical limit. This Review describes the PSTSCs' working principle and then summarizes the research progress in recent years, including a comparison of perovskite layers, interconnection layers, and silicon bottom cells. Then, the n-i-p PSTSCs and p-i-n PSTSCs are presented based on the PSCs' top cells, and the main factors affecting the efficiency of PSTSCs are discussed in detail. Finally, an outlook on the future development of PSTSCs is discussed.

electrical conductivity↗

Solar Canopy Expansion Project (Final Technical Report)

This project is a parking-lot canopy solar photovoltaic system, consisting of four canopy structures and 1,080 470-watt (W) modules. The nameplate rating of the project is 507.6 kilowatts direct current (kWDC) at Standard Test Condition (STC), and 448 kilowatts alternating current (kWAC). It is interconnected to the existing Tribe-owned medium-voltage micro-grid generation system via a step-up transformer and short medium-voltage line. This project offsets energy usage from more expensive existing sources, specifically the Tribe-owned gas-fired engine generators providing the primary power source for existing Tribal facilities and the electric utility, which provides an alternate source. The solar photovoltaic system is a renewable source, which has the benefit of reducing reliance on fossil-fuel burning sources. By reducing demand on existing Tribe-owned conventional generators, the project has avoided the need to add more conventional generation and has prolonged the lifespan of existing gas-fired engine generators. The project reduced energy costs and reliance on fossil-fuel burning power sources, increasing Tribe-owned generating sources and self-reliance, and prolonging the lifespan of existing generators. A side benefit to the project is the production of dozens of covered parking spaces in the existing parking lot.

14 SOLAR ENERGY↗