Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “selected inversion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Canonical analysis for increased classification speed and channel selection

The quadratic form can be expressed as a monotonically increasing sum of squares when the inverse covariance matrix is represented in canonical form. This formulation has the advantage that, in testing a particular class hypothesis, computations can be discontinued when the partial sum exceeds the smallest value obtained for other classes already tested. A method for channel selection is presented which arranges the original input measurements in that order which minimizes the expected number of computations. The classification algorithm was tested on data from LARS Flight Line C1 and found to reduce the sum-of-products operations by a factor of 6.7 in comparison with the conventional approach. In effect, the accuracy of a twelve-channel classification was achieved using only that CPU time required for a conventional four-channel classification.

Eppler, W.↗

Tunable Metal–Organic Frameworks Based on 8-Connected Metal Trimers for High Ethane Uptake

Metal trimers [M 3 (O/OH)](OOCR) 6 are among the most important structural building blocks. From these trimers, a great success has been achieved in the design of 6- or 9-connected framework materials with various topological features and outstanding gas-sorption properties. In comparison, 8-connected trimer-based MOFs are rare. Given multiple competitive pathways for the formation of 6- or 9-connected frameworks, it remains challenging to identify synthetic or structural parameters that can be used to direct self-assembly process towards trimer-based 8-connected materials. Here, we reveal a viable strategy called angle bending modulation for creating a prototypical MOF type based on 8-connected M 3 (OH)(OOCR) 5 (Py-R) 3 trimers, M = Zn, Co, Fe). As a proof of concept, we synthesized six members in this family using three types of ligands (CPM-80, -81, and -82). These materials do not possess open-metal sites and show excellent uptake capacity for various hydrocarbon gas molecules and inverse C 2 H 6 /C 2 H 4 selectivity. CPM-81-Co, made from 2,5-furandicarboxylate and isonicotinate, features selectivity of 1.80 with high uptake capacity for ethane (123 cm 3 /g -1 ) and ethylene (113 cm 3 /g -1 ) at 298 K and 1 bar.

36 MATERIALS SCIENCE↗

Management Trends and Outcomes for Stage I to II Mantle Cell Lymphoma Using the National Cancer Data Base: Ascertaining the Ideal Treatment Paradigm

Purpose: Mantle cell lymphoma (MCL) is a rare, albeit aggressive subset of non-Hodgkin lymphoma, resulting in varied treatment approaches. Given the paucity of data defining the optimal management for early-stage MCL, we conducted an analysis using the National Cancer Data Base (NCDB) to identify practice patterns and outcomes. Methods and Materials: The NCDB was queried for patients with stage I to II MCL diagnosed from 1998 to 2012 receiving chemotherapy (CT) or radiation therapy (RT), or both (CT+RT). Univariate and multivariable analyses for factors associated with treatment selection were completed using logistic regression. Propensity scores with inverse probability treatment weighting (IPTW) were calculated based on the conditional probability of receiving CT+RT. The log-rank test and Cox proportional hazards modeling with IPTW adjustment were conducted for the survival analyses. Results: In total, 2539 patients were identified. The key characteristics were as follows: 69% were male, 71% were aged ≥60 years, 28% had extranodal involvement, and 51% had stage I disease. Of the 2539 patients, 70% underwent CT, 11% underwent RT, and 19% underwent CT+RT. The use of CT+RT decreased from 23.1% to 14.1% in 1998 to 2002 and 2010 to 2012 (P<.001). CT+RT usage was lower for patients with the following characteristics: age ≥60 years, female sex, stage II disease, and the presence of B symptoms. With a median follow-up period of 42.8 months, the unadjusted 3-year overall survival estimates for patients receiving CT, RT, or CT+RT were 67.8%, 72.4%, and 79.8%, respectively (P<.001). After correcting for indication bias through IPTW-adjusted modeling, CT+RT reduced the risk of overall mortality compared with monotherapy (hazard ratio 0.65, P=.029). Conclusions: Although uncommon, patients with stage I-II MCL can have favorable outcomes. Despite a continued decline in the usage of consolidative RT, combined modality therapy improves survival in this cohort compared with monotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CO 2 Hydrogenation to Methanol over Inverse ZrO 2 /Cu(111) Catalysts: The Fate of Methoxy under Dry and Wet Conditions

Understanding the surface chemistry of CH 3 O species is essential for the production of methanol by CO 2 hydrogenation over Cu-based heterogeneous catalysts, as it facilitates the rational design of more efficient conversion processes. Recent research has identified inverse ZrO 2 /Cu catalysts as highly active and selective systems for the transformation of CO 2 to methanol with a performance that can be better than that of commercial Cu/ZnO catalysts. Here, we employed synchrotron-based ambient pressure X-ray photoelectron spectroscopy (AP-XPS) and calculations based on density functional theory (DFT) to understand the fate of CH 3 O groups under dry and wet environments. AP-XPS spectra revealed that under CO 2 hydrogenation conditions, formate and methoxy are two key intermediates to produce methanol. Furthermore, there are three different types of reactive sites on the surface: One is active for methoxy adsorption, which is stable and responsible for the methanol synthesis; Another one transforms CO 2 into CO; and a third one is active for CO 2 and methoxy dissociation, leading to C and methane formation. The theoretical calculations indicate that CH 3 OH readily dissociates to CH 3 O species following a highly exothermic (ΔE = -20.99 kcal/mol) and barrierless process. The water produced by the reverse water-gas shift reaction (CO 2 + H 2 → H 2 O + CO) can prevent the decomposition of CH 3 O species. We discovered that by introducing a tiny amount of water vapor (2 × 10 -6 Torr) into the reaction chamber, the energy barrier for the reaction CH 3 O(ads) + H(ads) → CH 3 OH(gas) is dramatically reduced. AP-XPS and computational modelling showed that water is quite capable of extracting adsorbed methoxy to form gaseous methanol. With this in mind, one could boost the methanol selectivity by adding appropriate amounts of water or steam, which is an inexpensive and feasible solution for industrial operations.

36 MATERIALS SCIENCE↗

Search for fractionally charged particles in p p collisions at s = 7 TeV

A search is presented for free heavy long-lived fractionally charged particles produced in pp collisions at $\sqrt{s}$ = 7 TeV. The data sample was recorded by the CMS detector at the LHC and corresponds to an integrated luminosity of 5.0 inverse femtobarns. Candidate fractionally charged particles are identified by selecting tracks with associated low charge measurements in the silicon tracking detector. Observations are found to be consistent with expectations for background processes. The results of the search are used to set upper limits on the cross section for pair production of fractionally charged, massive spin-1/2 particles that are neutral under SU(3)$_C$ and SU(2)$_L$. We exclude at 95% confidence level such particles with electric charge $\pm$2e/3 with masses below 310 GeV, and those with charge $\pm$e/3 with masses below 140 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-14: A Comparative Study Between Forward and Inverse Planning in Gamma Knife Radiosurgery for Acoustic Neuroma Tumours

Purpose: To evaluate forward and inverse planning methods for acoustic neuroma cases treated in Gamma Knife Perfexion. Methods: Five patients with acoustic neuroma tumour abutting brainstem were planned twice in LGP TPS (Version 10.1) using TMR10 algorithm. First plan was entirely based on forward planning (FP) in which each shot was chosen manually. Second plan was generated using inverse planning (IP) for which planning parameters like coverage, selectivity, gradient index (GI) and beam-on time threshold were set. Number of shots in IP was automatically selected by objective function using iterative process. In both planning methods MRI MPRAGE sequence images were used for tumour localization and planning. A planning dose of 12Gy at 50% isodose level was chosen. Results and Discussion: Number of shots used in FP was greater than IP and beam-on time in FP was in average 1.4 times more than IP. One advantage of FP was that the brainstem volume subjected to 6Gy dose (25% isodose) was less in FP than IP. Our results showed use of more number of shots as in FP results in GI less than or equal to 2.55 which is close to its lower limit. Dose homogeneity index (DHI) analysis of FP and IP showed average values of 0.59 and 0.67 respectively. General trend in GK for planning in acoustic neuroma cases is to use small collimator shots to avoid dose to adjacent critical structures. More number of shots and prolonged treatment time causes inconvenience to the patients. Similarly overuse of automatic shot shaping as in IP results in increased scatter dose. A compromise is required in shot selection for these cases. Conclusion: IP method could be used in acoustic neuroma cases to decrease treatment time provided the source sector openings near brainstem are shielded or adjusted appropriately to reduce brainstem dose.

60 APPLIED LIFE SCIENCES↗

SU-F-I-27: Measurement of SAR and Temperature Elevation During MRI Scans

Purpose: The poor reliability and repeatability of the manufacturer-reported SAR values on clinical MRI systems have been acknowledged. The purpose of this study is to not only measure SAR values, but also RF-induced temperature elevation at 1.5 and 3T MRI systems. Methods: SAR measurement experiment was performed at 1.5 and 3T. Three MRI RF sequences (T1w TSE, T1w inversion recovery, and T2w TSE) with imaging parameters were selected. A hydroxyl-ethylcelluose (HEC) gelled saline phantom mimicking human body tissue was made. Human torso phantom were constructed, based on Korean adult standard anthropometric reference data (Fig.1). FDTD method was utilized to calculate the SAR distribution using Sim4Life software. Based on the results of the simulation, 4 electrical field (E-field) sensors were located inside the phantom. 55 Fiber Bragg Grating (FBG) temperature sensors (27 sensors in upper and lower cover lids, and one sensor located in the center as a reference) were located inside the phantom to measure temperature change during MRI scan (Fig.2). Results: Simulation shows that SAR value is 0.4 W/kg in the periphery and 0.001 W/kg in the center (Fig.2). One 1.5T and one of two 3T MRI systems represent that the measured SAR values were lower than MRI scanner-reported SAR values. However, the other 3T MRI scanner shows that the averaged SAR values measured by probe 2, 3, and 4 are 6.83, 7.59, and 6.01 W/kg, compared to MRI scanner-reported whole body SAR value (<1.5 W/kg) for T2w TSE (Table 1). The temperature elevation measured by FBG sensors is 5.2°C in the lateral shoulder, 5.1°C in the underarm, 4.7°C in the anterior axilla, 4.8°C in the posterior axilla, and 4.8°C in the lateral waist for T2w TSE (Fig.3). Conclusion: It is essential to assess the safety of MRI system for patient by measuring accurate SAR deposited in the body during clinical MRI.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-IeP3-01: Evaluation of Specific Absorption Rate and Temperature Increase Induced by Artificial Medical Implants During MRI Scan

Purpose: Heating of patients or burning of biological tissues around medical implants by RF power during MRI scan is a significant patient safety concern. The purpose of this study is to not only measure SAR values, but also RF-induced temperature elevation due to artificial hip joints during MRI scans. Methods: SAR measurement experiment was performed on three discrete manufacturers at 1.5 and 3T. Three MRI RF sequences (T1w TSE, T2w inversion recovery, and T2w TSE) with imaging parameters were selected. A gelled saline phantom mimicking human body tissue was made (Fig.1). FDTD method was utilized to calculate the SAR distribution using Sim4Life software. Based on the results of the simulation, 4 electrical field (E-field) sensors were located around two artificial hip joints inside the phantom. 56 Fiber Bragg Grating (FBG) temperature sensors (28 sensors on each artificial hip joint) were located on both left and right artificial hip joints to measure temperature change during MRI scan (Fig.1). Both E-field and FBG temperature sensors were calibrated with traceability at Korea Research Institute of Standards and Science (KRISS). Results: Simulation shows that high SAR values occur in the head and tail of the implanted artificial hip joints (Fig.1 lower right). 3T MRI scanner shows that the local averaged-SAR values measured by probe 1, 2, and 3 are 2.30, 2.77, and 1.68 W/kg, compared to MRI scanner-reported whole body SAR value (≤1.5 W/kg) for T1w TSE and T2w-IR (Table 1). The maximum temperature elevation measured by FBG sensors is 1.49°C at 1.5 T, 2.0°C at 3 T, and 2.56°C at 3 T for T1w TSE, respectively (Table 2). Conclusion: It is essential to assess the safety of MRI system for patient with medical implant by measuring not only accurate SAR deposited in the body, but also temperature elevation due to the deposited SAR during clinical MRI.

60 APPLIED LIFE SCIENCES↗

Algorithm for vertical ozone profile determination for the Nimbus-4 BUV data set

A description is provided of the algorithm used by the Ozone Processing Team at NASA to process seven years of Backscatter Ultraviolet (BUV) ozone profile data. The algorithm is a modification of the original retrieval algorithm developed by Mateer (1972) to process some of the early data from the BUV experiment. Principal changes made are in the first guess selection scheme, the use of all wavelengths in the inversion, and the weighting of the various wavelengths according to the errors in the radiance estimation. It is found that the described BUV ozone profile algorithm is an extremely efficient algorithm for retrieving large amounts of satellite data. The algorithm makes full use of all the available information from the measured radiances including the longer wavelength radiances which previously had not been used.

Bhartia, P. K.↗

Convex-profile inversion of asteroid lightcurves - Theory and applications

A theory for asteroid light curve interpretation is derived from the reformulation, extension, and calibration of Ostro and Connely's (1984) convex-profile inversion, and then used to constrain the shapes of selected asteroids. The ideal conditions for the estimation of an asteroid's main cross-section from a light curve are (1) that the viewing-illumination geometry be equatorial, (2) that the scattering be uniform and geometric, (3) that the asteroid surface contours parallel to the equatorial plane be convex, (4) and that the solar angle not equal zero. Results are presented from simulations calibrating the kind, severity, and predictability of systematic errors.

Ostro, Steven J.↗

Total recall in distributive associative memories

Iterative error correction of asymptotically large associative memories is equivalent to a one-step learning rule. This rule is the inverse of the activation function of the memory. Spectral representations of nonlinear activation functions are used to obtain the inverse in closed form for Sparse Distributed Memory, Selected-Coordinate Design, and Radial Basis Functions.

Danforth, Douglas G.↗

SU-E-T-409: Intensity Modulated Robotic Radiotherapy

Purpose: As compared with the IRIS-based models, the MLC-based CyberKnife system allows more efficient treatment delivery due to its improved coverage of large lesions and intensity modulation. The treatment delivery efficiency is mainly determined by the number of selected nodes. This study aimed to demonstrate that relatively small sets of optimally selected nodes could produce high-quality plans. Methods: The full body path of the CyberKnife system consists of 110 nodes, from which we selected various sets for 4 prostate cancer cases using our in-house beamselection software. With the selected nodes we generated IMRT plans using our in-house beamlet-based inverse-planning optimization program. We also produced IMRT plans using the MultiPlan treatment planning system (version 5.0) for the same cases. Furthermore, the nodes selected by MultiPlan were used to produce plans with our own optimization software so that we could compare the quality of the selected sets of nodes. Results: Our beam-selection program selected one node-set for each case, with the number of nodes ranging from 23 to 34. The IMRT plans based on the selected nodes and our in-house optimization program showed adequate target coverage, with favorable critical structure sparing for the cases investigated. Compared with the plans using the nodes selected by MultiPlan, the plans generated with our selected beams provided superior rectum/bladder sparing for 75% of the cases. The plans produced by MultiPlan with various numbers of nodes also suggested that the plan quality was not compromised significantly when the number of nodes was reduced. Conclusion: Our preliminary results showed that with beamletbased planning optimization, one could produce high-quality plans with an optimal set of nodes for MLC-based robotic radiotherapy. Furthermore, our beam-selection strategy could help further improve critical structure sparing.

60 APPLIED LIFE SCIENCES↗

Project Final Report - Advanced Oxygen Separation from Air Using a Novel Mixed Matrix Membrane

This report describes a summary of the findings of the project. The technical work was divided into three activities: 1) technoeconomic analysis; 2) membrane component development (support layer, selective layer development, and gutter layer formulation); and 3) hollow fiber formation. The technoeconomic analysis includes operating, capital, and materials costs of an oxygen enrichment system with 1-3 stages. The analysis concluded that the desired gas quality (90-95% O2) cannot be reached with a single stage. The triple stage system yielded the best overall product quality at lower membrane performance levels but with the highest cost. For the membrane development activities, functionalized nanodiamonds have been shown to slightly improve membrane formation behaviors and gas permeability performance. For example, support layers based on polysulfone-nanodiamond composites have been formed that increase the material’s O2 permeability by over a factor of 150, however, at the cost of selectivity that suggests a change in transport mechanism. Furthermore, nanodiamonds have been found to improve membrane durability. Improvements in selective and gutter layers also have been accomplished. An additional accomplishment is the demonstration of phase inversion of polysulfone-nanodiamond composites that ensures that hollow fiber formation can be performed. Finally, the interfaces between support, gutter, and selective layers were briefly examined and the resulting membrane material consisting of all three layers gave good performance in an O2 separation from N2. The three-layer prototype membrane gave permeability of 29.2-32.2 Barrers, which equates to permeance of approximately 290-320 GPU, which is lower than the TEA informed goal of 500 GPU. O2/N2 selectivity ranged from 5.2-6.2, which is consistent with the less costly two-stage implementation of the technology. In summary, new materials have been developed for O2 concentration from air and are well-suited to a hollow fiber format.

20 FOSSIL-FUELED POWER PLANTS↗

Single-state selection system for hydrogen masers

The design and operation of a single-state selection system based on the adiabatic fast-passage technique for atomic state inversion is described. The system uses a variable-pitch dc solenoid and orthogonal four-wire RF coil to create the state-changing magnetic fields, and a half-wavelength state selection magnet to remove the inverted state atoms from the hydrogen beam. The system's performance was determined by measuring maser power as a function of line Q. The system removes more than 85 percent of undesired atoms from the beam. The potential effects of improvements in the maser on its frequency stability have been calculated. The use of single-state selection combined with increased RF coupling to the cavity and increased storage bulb collimation offers the possibility of frequency stability in the 10 to the -17th regime over intervals on the order of 60,000 s.

Mattison, Edward M.↗

Validation of Inverse Methods Applied to Forensic Analysis of Spent Fuel

Inverse depletion/decay methods are useful tools for application to nuclear forensics. Previously, inverse methods were applied to the generic case of predicting the burnup, initial enrichment, and cooling time for selected spent nuclear fuels based on measured actinide and fission product concentrations. These existing measurements were not developed or optimized for use by these inverse techniques, and hence previous work demonstrated the prediction of only the fuel burnup, initial enrichment, and cooling time. Previously, nine spent fuel samples from an online data compilation were randomly selected for study. This work set out to demonstrate the full prediction capabilities using measured isotopic data, but with a more deliberate selection of fuel samples. The current approach is to evaluate nuclides within the same element to see if complementary information can be obtained in addition to the reactor burnup, enrichment, and cooling. Specifically, the reactor power and the fuel irradiation time values are desired to achieve the maximum prediction capabilities of these techniques.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calibration-free device sizing using an inverse geometry x-ray system

Purpose: Quantitative coronary angiography (QCA) can be used to support device size selection for cardiovascular interventions. The accuracy of QCA measurements using conventional x-ray fluoroscopy depends on proper calibration using a reference object and avoiding vessel foreshortening. The authors have developed a novel interventional device sizing method using the inverse geometry scanning-beam digital x-ray (SBDX) fluoroscopy system. The proposed method can measure the diameter and length of vessel segments without imaging a reference object and when vessels appear foreshortened. Methods: SBDX creates multiple tomosynthetic x-ray images corresponding to planes through the patient volume. The structures that lie in the plane are in focus and the features above and below the plane are blurred. Three-dimensional localization of the vessel edges was performed by examining the degree of blurring at each image plane. A 3D vessel centerline was created and used to determine vessel magnification and angulation relative to the image planes. Diameter measurements were performed using a model-based method and length measurements were calculated from the 3D centerline. Phantom validation was performed by measuring the diameter and length of vessel segments with nominal diameters ranging from 0.5 to 2.8 mm and nominal lengths of 42 mm. The phantoms were imaged at a range of positions between the source and the detector ({+-}16 cm relative to isocenter) and with a range of foreshortening angles (0 deg. - 75 deg.). Results: Changes in vessel phantom position created magnifications ranging from 87% to 118% relative to isocenter magnification. Average diameter errors were less than 0.15 mm. Average length measurements were within 1% (0.3 mm) of the true length. No trends were observed between measurement accuracy and magnification. Changes in vessel phantom orientation resulted in decreased apparent length down to 28% of the original nonforeshortened length. Average diameter errors were less than 0.25 mm across all vessel angulations; errors were less than 0.1 mm for smaller diameter vessels and low to moderate vessel angles. Diameter errors increased with true diameter and vessel angle relative to the image plane. Average length measurement errors were also within 1% (0.3 mm) for each angulation. Conclusions: Tomosynthetic imaging with SBDX can accurately measure dimensions of vessels in various magnifications and angulations without calibration. This method may be more accurate and convenient than conventional QCA techniques.

60 APPLIED LIFE SCIENCES↗

Impact of the HIV-1 genetic background and HIV-1 population size on the evolution of raltegravir resistance

Background Emergence of resistance against integrase inhibitor raltegravir in human immunodeficiency virus type 1 (HIV-1) patients is typically associated with selection of one of three signature mutations: Y143C/R, Q148K/H/R or N155H, representing three distinct resistance pathways. The mechanisms that drive selection of a specific pathway are still poorly understood. We reviewed the effect of the HIV-1 genetic background and population dynamics on the emergence of raltegravir resistance. Using deep sequencing we analyzed the integrase coding sequence (CDS) in longitudinal samples from five patients who initiated raltegravir plus optimized background therapy at viral loads > 5000 copies/ml. To investigate the role of the HIV-1 genetic background we created recombinant viruses containing the viral integrase coding region from pre-raltegravir samples from two patients in whom raltegravir resistance developed through different pathways. The in vitro selections performed with these recombinant viruses were designed to mimic natural population bottlenecks. Results Deep sequencing analysis of the viral integrase CDS revealed that the virological response to raltegravir containing therapy inversely correlated with the relative amount of unique sequence variants that emerged suggesting diversifying selection during drug pressure. In 4/5 patients multiple signature mutations representing different resistance pathways were observed. Interestingly, the resistant population can consist of a single resistant variant that completely dominates the population but also of multiple variants from different resistance pathways that coexist in the viral population. We also found evidence for increased diversification after stronger bottlenecks. In vitro selections with low viral titers, mimicking population bottlenecks, revealed that both recombinant viruses and HXB2 reference virus were able to select mutations from different resistance pathways, although typically only one resistance pathway emerged in each individual culture. Conclusions The generation of a specific raltegravir resistant variant is not predisposed in the genetic background of the viral integrase CDS. Typically, in the early phases of therapy failure the sequence space is explored and multiple resistance pathways emerge and then compete for dominance which frequently results in a switch of the dominant population over time towards the fittest variant or even multiple variants of similar fitness that can coexist in the viral population.

60 APPLIED LIFE SCIENCES↗

Nonresonant interaction of ultrashort electromagnetic pulses with multilevel quantum systems

Some features of the excitation of multilevel quantum systems under the action of electromagnetic pulses which are shorter than the inverse frequency of interlevel transitions are considered. It is shown that the interaction is characterized by a specific type of selectivity which is not connected with the resonant absorption of radiation. The simplest three-level model displays the inverse population of upper levels. The effect of an ultrashort laser pulse on a multilevel molecule was regarded as an instant reception of the oscillation velocity by the oscillator and this approach showed an effective excitation and dissociation of the molecule. The estimations testify to the fact that these effects can be observed using modern femtosecond lasers.

Belenov, E.↗