Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “secondary distribution system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

An Updated Secondary Lunar Meteoroid Ejecta Model for Engineering Design

Introduction: The surface of the Moon is constantly being bombarded by a flux of meteoroids of various sizes. Impacts due to these meteoroids produce secondary ejecta material at much lower speeds but with a total mass larger than the original impactor. Details about the secondary ejecta are important for planning missions on the lunar surface. In this work, an updated ejecta model is presented called the Meteoroid Model of Secondary Ejecta (MeMoSeE), to re-place the Apollo-era ejecta model, NASA SP-8013 [1], in the SLS-SPEC 159 Design Specification for Natural Environments (DSNE) [2]. The model pro-duces secondary ejecta flux environments for a user-specified location on the lunar surface, and sorts the incoming secondary flux by angular direction and speed. Methods: MeMoSeE is separated into three parts: the inputs, the conversion step, and the integration of fluxes. Inputs to the model include the primary meteoroid fluxes and the primary near-Earth object (NEO) fluxes. Meteoroid fluxes, both asteroidal and cometary, are calculated using the Meteoroid Engineering Model (MEM3) [3] for different locations on the Moon. For each surface location, an ephemeris is generated using the JPL HORIZONS System [4] that feeds into MEM3. The NEO fluxes are approximated by the high-density population of MEM3 (i.e., only the directionality), where the speed distribution of the NEO fluxes is renormalized to match observations [5]. The regolith properties are used as defined in the DSNE [2]. The conversion step utilizes scaling laws given by Housen & Holsapple 2011 [6] to convert the primary impactor flux to the total mass of secondary ejecta. The ejecta distribution, at the point-of-impact (POI), is separated into a zenith angle and azimuthal angle distribution. The zenith angle distribution follows a beta distribution where the peak depends on the impact altitude angle and the impact azimuth [7]. We employ an ejecta azimuth distribution that is based on Rival & Mandeville 1999 [8] which focuses ejecta in the downstream direction for more oblique impacts. Finally, during the integration step, we sum secondary ejecta number fluxes at a particular region-of-interest (ROI) that originated from many POI locations over the entire surface of the Moon. We keep track of both altitude and azimuth angle bins as well as a range of speed bins, following the igloo gridding as done in MEM3 [9]. The ejecta particle size distribution and density is assumed to be the same as the lunar regolith [10, 2]. Results: The primary fluxes are computed for one Metonic cycle (19 years) for various locations over the lunar surface with a fixed orientation. Both the angular and speed distributions of the primary fluxes are dependent on the latitude and longitude. The over-all primary fluxes show a roughly 13% increase from the eastern limb to the western limb. In general, the speed distribution of the secondary fluxes span from a user-defined minimum speed to the escape speed of the Moon (2.38 km/s), roughly following a power-law relation [6]. Different parts of the speed distribution come from different primary impact locations on the Moon. The secondary ejecta is dominated by the slowest speeds, where these particles originate nearby the ROI. For speeds around 71% of the escape speed, the secondary ejecta originates from locations near the antipodal point. On the other hand, for secondary ejecta speeds that exceed roughly 90% the escape speed, the ejecta particles come from all over the lunar surface to the ROI. Comparing the secondary ejecta fluxes from MeMoSeE with NASA SP-8013 [1], there is a reduction by about 2-3 orders of magnitude for secondary ejecta particles greater than 1 µg. These estimates agree with recent findings from Bjorkman & Christiansen 2019 [11]. The secondary ejecta fluxes are also compared with the primary fluxes, where the ejecta fluxes are roughly an order of magnitude greater than the primary fluxes. References: [1] Cour-Palais, B. G., (1969) NASA SP-8013. [2] NASA SLS-SPEC-159 Rev. H (2020). [3] Moorhead, A. V., et al. (2019) JS&R, 1-17. [4] Giorgini, J. D., (2015) IAUGA, 29, 2256293. [5] Moorhead, A. V., (2020) Memo OSMA/MEO/Lunar-001. [6] Housen, K. R., and Holsapple, K. A., (2011) Icarus, 211(1), 856-875. [7] Gault, D. E., and Wedekind, J. A., (1978) L&PSCP, 9, 3843-3875. [8] Rival, M., and Mandeville, J., (1999) Space Debris, 1(1), 45-57. [9] Moorhead, A. V., (2019) MEM3 User Guide. [10] Carrier, W. D., (1973) The Moon, 6(3-4), 250-263. [11] Bjorkman, M. D. & Christiansen, E. L., (2019) ODC

impacts↗

Improving I/O Performance for Exascale Applications through Online Data Layout Reorganization

The applications being developed within the U.S. Exascale Computing Project (ECP) to run on imminent Exascale computers will generate scientific results with unprecedented fidelity and record turn-around time. Many of these codes are based on particle-mesh methods and use advanced algorithms, especially dynamic load-balancing and mesh-refinement, to achieve high performance on Exascale machines. Yet, as such algorithms improve parallel application efficiency, they raise new challenges for I/O logic due to their irregular and dynamic data distributions. Thus, while the enormous data rates of Exascale simulations already challenge existing file system write strategies, the need for efficient read and processing of generated data introduces additional constraints on the data layout strategies that can be used when writing data to secondary storage. We review these I/O challenges and introduce two online data layout reorganization approaches for achieving good tradeoffs between read and write performance. We demonstrate the benefits of using these two approaches for the ECP particle-in-cell simulation WarpX, which serves as a motif for a large class of important Exascale applications. Here, we show that by understanding application I/O patterns and carefully designing data layouts we can increase read performance by more than 80 percent.

97 MATHEMATICS AND COMPUTING↗

Advancing Grid Resilience through Smart Charge Management: Findings from Maryland’s Pilot

This report presents research findings from a four-year Smart Charge Management (SCM) pilot program conducted by Maryland’s largest electric utilities—Baltimore Gas and Electric (BGE), Potomac Electric Power Company (Pepco), and Delmarva Power & Light (DPL)—to evaluate strategies for optimizing electric vehicle (EV) charging loads and enhancing grid stability. Supported by the U.S. Department of Energy (DOE), Argonne National Laboratory collaborated with all project partners and examined the effectiveness of Time-of-Use (TOU) and Load Balancing (LB) strategies in managing peak demand, deferring costly infrastructure upgrades, and reducing grid constraints at the feeder level. Using charging data from over 4,600 EV drivers, the study analyzed SCM’s impact on the distribution systems of BGE and Pepco, which consists of over 2000 feeders. Unlike prior research that focused on system-wide trends or synthetic feeders, this analysis offers granular, feeder-level insights based on real-world operational data. It highlights how transformer density, load profiles, and infrastructure constraints influence smart charging performance. Results show feeder-level conditions play a crucial role in SCM effectiveness, with most feeders benefiting more from LB, while TOU-based SCM may be sufficient for others. By 2035, LB reduced peak charging loads by 27% on average, compared to 23% under TOU-based SCM, though some feeders saw reductions exceeding 35%, while others experienced minimal impact. Feeders with higher transformer utilization and limited capacity benefited more from LB, which more effectively distributed charging demand during off-peak hours. Beyond reducing grid constraints, SCM offers long-term operational and financial benefits. By shifting EV charging demand strategically, utilities can optimize asset utilization, delay infrastructure investments, and enhance grid performance. In terms of infrastructure upgrade deferrals, at the feeder level, LB consistently reduced peak charging loads and resulting infrastructure upgrade costs, particularly in high EV enrollment areas, decreasing the number of overloaded transformers by up to 35%, while TOU-based SCM achieved 20-30% reductions depending on feeder characteristics. At the system level, LB has the potential to defer total upgrade costs by $\$$186 million for BGE, compared to $\$$159 million under TOU-based SCM. For Pepco, TOU-based SCM performed slightly better, deferring upgrade costs by $\$$30 million, compared to $\$$29 million under LB. Section 4.5 reviews some of the system differences between BGE and Pepco. However, as EV adoption scales, TOU-based SCM will introduce secondary peak charging loads, reinforcing the need for more advanced, adaptive SCM approaches to prevent new grid challenges. As EV adoption continues to grow, feeder-level managed charging strategies will be essential for mitigating grid stress, improving infrastructure efficiency, and maintaining energy affordability for consumers. This report provides critical insights for utilities, Public Utility Commissions (PUCs), and state agencies on the role of feeder-specific smart charging in infrastructure planning, policy development, and grid modernization. The findings underscore the importance of tailored, data-driven SCM solutions that align with local grid conditions, ensuring a resilient, cost-effective transition to increasing EV adoption while safeguarding distribution system performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution Grid Impact Study in Highland Park, Michigan: Understanding Rooftop Solar, Behind-the-Meter Energy Storage, Electric Vehicle Charging, and Building Electrification [Slides]

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "B" related to policy analysis, due diligence, and case studies for removing barriers and providing best practices for local clean energy development. Highland Park community members face frequent, long-duration power interruptions due largely to the aging distribution system serving the area and the legacy design standards used in its construction. While degrading physical infrastructure such as poles, crossarms, and transformers can result in this substandard reliability, another notable characteristic of this legacy system is the lower, 4.8 kV, voltage class. This is a legacy construction standard which many utilities, DTE included, are phasing out in favor of higher, 15 or 25 kV, voltage classes instead. The existing 4.8 kV distribution system serving Highland Park may limit significant adoptions of clean-energy technologies like high percentages of building electrification or electric vehicle adoption. The following analysis seeks to quantify these limitations under a variety of clean-energy technology adoption scenarios. It compares the overall system risks of the present system to those of a hypothetical, upgraded 13.2 kV system, using NREL-developed risk metrics and offers upgrade cost considerations. The legacy 4.8 kV voltage class serving Highland park is not, as we have modeled it, a major limitation to the widespread adoption of cost-optimal rooftop solar and/or behind-the-meter energy storage. Within our modeling framework, these technologies namely impact secondary, low-voltage assets, which may be remedied without the need for a system-wide upgrade to a 13.2 kV voltage class. Our model of the current 4.8kV system indicates it is not capable of supporting community-wide electrification efforts. Widespread building electrification, and the resulting large increase in wintertime load, dramatically increases the prevalence of voltage violations and thermal overloading on the current 4.8 kV distribution system. These impacts illustrate the need for system-wide upgrades to a 13.2 kV voltage class to accommodate these technologies. Low to Moderate DER adoption does not adversely impact the grid but does improve undervoltage and asset overloading issues. However, these benefits are insufficient to defer grid upgrades. Higher DER penetration is shown to increase overvoltage and asset overloading in future electrification scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Calcined Polyethyleneimine Coated Optical Fibers for Distributed pH Monitoring at High Pressures and Temperatures

In the oil and gas, CO2 sequestration, H2 subsurface storage, and geothermal energy sectors, subsurface pH measurements are critical for monitoring the geochemical conditions and estimating potential corrosion rates of wellbore systems. Real-time pH measurements in these conditions are vital for detecting and predicting corrosion deterioration of wellbore components that may jeopardize the safety and continued operation of wellbore systems. Building off of earlier TiO2 based pH sensors and the known pH sensitivity of amine-based polymers, a coating based on the secondary amine polymer polyethyleneimine (PEI) was developed. The sensor coating was treated with a high temperature (500 °C) calcination procedure in air to convert it into a more stable oxidized coating capable of withstanding hot aqueous solutions without dissolving while retaining linear pH sensitivity from pH values between 2 and 11. The sensor performance was measured using optical transmission measurements in solutions of various pHs and using optical backscatter reflectometry for distributed pH sensing demonstration in wellbore-relevant pressures (up to 1000 psi) and temperatures (80 °C). A calibration curve with strong differentiation between acidic and alkaline pH was developed for both transmission-based and distributed pH measurements, using fixed wavelength transmission and integrated linear amplitude of backscattered light for distributed measurements.

Shumski, Alexander↗

TIC 278956474: Two Close Binaries in One Young Quadruple System Identified by TESS

We have identified a quadruple system with two close eclipsing binaries in Transiting Exoplanet Survey Satellite (TESS) data. The object is unresolved in Gaia and appears as a single source at parallax 1.08 ± 0.01 mas. Both binaries have observable primary and secondary eclipses and were monitored throughout TESS Cycle 1 (sectors 1–13), falling within the TESS Continuous Viewing Zone. In one eclipsing binary (P = 5.488 days), the smaller star is completely occluded by the larger star during the secondary eclipse; in the other (P = 5.674 days) both eclipses are grazing. Using these data, spectroscopy, speckle photometry, spectral energy distribution analysis, and evolutionary stellar tracks, we have constrained the masses and radii of the four stars in the two eclipsing binaries. The Li i equivalent width indicates an age of 10–50 Myr and, with an outer period of 858{sub −5}{sup +7} days, our analysis indicates this is one of the most compact young 2 + 2 quadruple systems known.

79 ASTRONOMY AND ASTROPHYSICS↗

Nonidealities in Rotating Detonation Engines

A rotating detonation engine (RDE) is a realization of pressure-gain combustion, wherein a traveling detonation wave confined in a chamber provides shock-based compression along with chemical heat release. Due to the high wave speeds, such devices can process high mass flow rates in small volumes, leading to compact and unconventional designs. RDEs involve unsteady and multiscale physics, and their operational characteristics are determined by an equilibrium between large- and small-scale processes. While RDEs can provide a significant theoretical gain in efficiency, achieving this improvement requires an understanding of the multiscale coupling. Specifically, unavoidable nonidealities, such as unsteady mixing, secondary combustion, and multiple competing waves associated with practical designs, need to be understood and managed. The secondary combustion processes arise from fuel/air injection and unsteady and incomplete mixing, and can create spurious losses. In addition, a combination of multiple detonation and secondary waves compete and define the dynamical behavior of mixing, heat release distribution, and the overall mode of operation of the device. This review discusses the current understanding of such nonidealities and describes the tools and techniques used to gain insight into the extreme unsteady environment in such combustors.

33 ADVANCED PROPULSION SYSTEMS↗

Helium Ion Microscopy with Secondary Ion Mass Spectrometry for Nanoscale Chemical Imaging and Analysis of Polyolefins

To date, chemical imaging of polymers and polymer blends has been primarily accomplished using time-of-flight secondary ion mass spectrometry (ToF-SIMS) to directly visualize the distribution of components in a complex material with spatial resolution ranging from 100 nm to 5 μm. However, in many cases, this resolution falls far short of visualizing interfaces directly. To overcome these limitations, recent work has focused on developing a SIMS detection system based on a helium ion microscope (HIM) enabling chemical imaging with a demonstrated ~14 nm spatial resolution. Here, we utilize HIM-SIMS for differentiation between the olefin-based polymers of polyethylene (PE) and polypropylene (PP). We illustrate both analyses for separating PE and PP using specific mass fragment ratios as well as demonstrate spatially resolved imaging of phase-separated domains within PE. Altogether, we demonstrate the abilities of HIM-SIMS as a multimodal chemical technique for imaging and quantification of polyolefin interfaces, which could be more broadly applied to the analysis of more complex polymeric systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Reduced-Order Model of a Nuclear Power Plant with Thermal Power Dispatch

This paper presents reduced-order modeling of thermal power dispatch (TPD) from a pressurized water reactor (PWR) for providing heat to nearby heat consuming industrial processes that seek to take advantage of nuclear heat to reduce carbon emissions. The reactor model includes the neutronics of the reactor core, thermal–hydraulics of the primary coolant cycle, and a three-lump model of the steam generator (SG). The secondary coolant cycle is represented with quasi-steady state mass and energy balance equations. The secondary cycle consists of a steam extraction system, high-pressure and low-pressure turbines, moisture separator and reheater, high-pressure and low-pressure feedwater heaters, deaerator, feedwater and condensate pumps, and a condenser. The steam produced by the SG is distributed between the turbines and the extraction steam line (XSL) that delivers steam to nearby industrial processes, such as production of clean hydrogen. The reduced-order simulator is verified by comparing predictions with results from separate validated steady-state and transient full-scope PWR simulators for TPD levels between 0% and 70% of the rated reactor power. All simulators indicate that the flow rate of steam in the main steam line and turbine systems decrease with increasing TPD, which causes a reduction in PWR electric power generation. The results are analyzed to assess the impact of TPD on system efficiency and feedwater flow control. Due to the simplicity of the proposed reduced-order model, it can be scaled to represent a PWR of any size with a few parametric changes. In the future, the proposed reduced-order model will be integrated into a power system model in a digital real-time simulator (DRTS) and physical hardware-in-the-loop simulations.

08 HYDROGEN↗

Echo Tomography of Reprocessing Sites in X-Ray Binaries

We discovered correlated rapid variability between the optical/UV and X-ray emission for the first time in a soft X-ray transient, GRO J1655-40. Hubble Space Telescope light curves show features similar to those seen by the Rossi X-ray Timing Explorer, but with a mean delay of up to 10 - 20 s. We interpret the correlation as the result of reprocessing of X-rays into optical and UV emission, with a delay owing to finite light travel time; this assumption enables us to perform echo mapping of the system. The time-delay distribution has a mean of 14.6 +/-1.4 s and a dispersion of 10.5+/-1.9 s at binary phase 0.4. This establishes that the reprocessing region is the accretion disk around the compact star, rather than the mass-donating secondary. These results have been published.

Patterson, Joseph↗

Telescope-optical system performance analysis for the Cryogenic Limb Array Etalon Spectrometer (CLAES) on the Upper Atmospheric Research Satellite

A first-order performance analysis of the CLAES telescope-optical system is presented. The experiment involves the passive measurement of earth-limb radiance over a 10-60 km tangent altitude range, and is based on a solid Fabry-Perot spectrometer which provides spectral resolution of 0.25/cm for atmospheric emission spectroscopy over the 3.5-12 micron IR range. The optical system is required to provide a high degree of off-axis rejection and stray-light control, primarily to suppress intense emission from the earth surface. The astigmatism and other geometric aberrations are corrected by a secondary mirror which produces an excellent image of the primary one, allowing for location of a diffraction control or Lyot stop. The off-axis scattering performance of the telescope is examined in terms of the mirror scatter coefficient and point source rejection ratio. A mirror bidirectional reflectance distribution function of 0.0001 at 1 deg with a 1/theta-squared roll-off between 1 and 0.2 deg is realizable based on recent measurements. This results in an off-axis radiance term that is generally small in comparison with the system-limiting NER.

Roche, A. E.↗

Outer atmospheres of cool stars. X - HR 1099 at quadrature

IUE high-dispersion, far-UV spectra of the active-chromosphere RS CVn binary HR 1099 are reported. The emission features produced by such high-temperature species as C II and C IV are found to be very bright, to exhibit structure, change significantly in the one-week interval separating the two exposures, and generally follow the radial velocity motion of the K subgiant primary, while the less massive G dwarf secondary appears only weakly in the composite spectrum. It is concluded that chromospheric and transition region emission in RS CVn binaries is a stellar rather than system phenomenon, and the structure evident in some of the emission line shapes is interpreted as a patchy brightness distribution on and above the K star surface that is spread out in velocity by the rapid rotation.

Ayres, T. R.↗

Frequency Recovery in Power Grids Using High-Performance Computing

Maintaining electric power system stability is paramount, especially in extreme contingencies involving unexpected outages of multiple generators or transmission lines that are typical during severe weather events. Such outages often lead to large supply-demand mismatches followed by subsequent system frequency deviations from their nominal value. The extent of frequency deviations is an important metric of system resilience, and its timely mitigation is a central goal of power system operation and control. This paper develops a novel nonlinear model predictive control (NMPC) method to minimize frequency deviations when the grid is affected by an unforeseen loss of multiple components. Our method is based on a novel multi-period alternating current optimal power flow (ACOPF) formulation that accurately models both nonlinear electric power flow physics and the primary and secondary frequency response of generator control mechanisms. We develop a distributed parallel Julia package for solving the large-scale nonlinear optimization problems that result from our NMPC method and thereby address realistic test instances on existing high-performance computing architectures. Our method demonstrates superior performance in terms of frequency recovery over existing industry practices, where generator levels are set based on the solution of single-period classical ACOPF models.

nonlinear model predictive control↗

AC/DC Power Systems with Applications for future Lunar/Mars base and Crew Exploration Vehicle

ABSTRACT The Power Systems branch at JSC faces a number of complex issues as it readies itself for the President's initiative on future space exploration beyond low earth orbit. Some of these preliminary issues - those dealing with electric power generation and distribution on board Mars-bound vehicle and that on Lunar and Martian surface may be summarized as follows: Type of prime mover - Because solar power may not be readily available on parts of the Lunar/Mars surface and also during the long duration flight to Mars, the primary source of power will most likely be nuclear power (Uranium fuel rods) with a secondary source of fuel cell (Hydrogen supply). The electric power generation source - With nuclear power being the main prime mover, the electric power generation source will most likely be an ac generator at a yet to be determined frequency. Thus, a critical issue is whether the generator should generate at constant or variable frequency. This will decide what type of generator to use - whether it is a synchronous machine, an asynchronous induction machine or a switched reluctance machine. The type of power distribution system - the distribution frequency, number of wires (3- wire, 4-wire or higher), and ac/dc hybridization. Building redundancy and fault tolerance in the generation and distribution sub-systems so that the system is safe; provides 100% availability to critical loads; continues to operate even with faulted sub-systems; and requires minimal maintenance. This report descril_es results of a summer faculty fellowship spent in the Power Systems Branch with the specific aim of investigating some of the lessons learned in electric power generation and usage from the terrestrial power systems industry, the aerospace industry as well as NASA's on-going missions so as to recommend novel surface and vehicle-based power systems architectures in support of future space exploration initiatives. A hybrid ac/dc architecture with source side and load side redundancies and including emergency generators on both ac and dc sides is proposed. The generation frequency is 400 Hz mostly because of the technology maturity at this frequency in the aerospace industry. Power will be distributed to several ac load distribution buses through solid state variable speed, constant frequency converters on the ac side. A segmented dc ring bus supplied from ac/dc converters and with the capability of connecting/disconnecting the segments will supply power to multiple de load distribution buses. The system will have the capability of reverse flow from dc to ac side in the case of an extreme emergency on the main ac generation side.

Chowdhury, Badrul H.↗

Nonlinear Virtual Inertia Control of WTGs for Enhancing Primary Frequency Response and Suppressing Drivetrain Torsional Oscillations

Virtual inertia controllers (VICs) for wind turbine generators (WTGs) have been recently developed to compensate the reduction of inertia in power systems. However, VICs can induce drivetrain torsional oscillations of WTGs. This paper addresses this issue and develops a novel nonlinear VIC based on objective holographic feedback theory and the definition of a completely controllable system of Brunovsky type. Simulation results under various scenarios demonstrate that the proposed technique outperforms existing VICs in terms of enhancement of system frequency nadir, suppression of WTG drivetrain torsional oscillations, fast and smooth recovery of WTG rotor speed to the original maximum power point (MPP) before the disturbance as well as preventing secondary frequency dip caused by traditional VIC. The proposed technique is also able to adaptively coordinate multiple WTGs to enhance the frequency support and the dynamic performance of each WTG.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TCF-20-20213: Advanced Power Distribution Sensing and Communications through the Cable TV Broadband Network (Final Report. Period of Performance: June 2020 to June 2022)

To enable the rapid, widespread commercial availability of secondary distribution grid voltage and phase angle data, the DOE OE Technology Commercialization Fund (TCF) project: 1) created a new American National Standard for next-generation grid power quality sensing and communications, 2) created a new prototype broadband-based standard-compliant grid power sensing system for use by utilities and others, and 3) improved by several orders of magnitude the spatiotemporal scale of the in-progress DOE CESER project: Situational Awareness of Grid Anomalies (SAGA) for Visual Analytics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ISEE-1 and ISEE-2 fast plasma experiment and the ISEE-1 solar wind experiment

Identical fast plasma experiment (FPE) systems were placed on the ISEE-1 and ISEE-2 spacecraft. The FPE consists of three high efficiency 90 deg spherical section electrostatic analyzers using large secondary emitters and discrete dynode multipliers to detect analyzed particles. Two of them, viewing in opposite directions, produce complete 2D velocity distribution measurements of both protons and electrons every spacecraft revolution. A third FPE analyzer with a divided emitter measures 3D distributions at a slower rate. ISEE-1 also carries a solar-wind experiment (SWE) to measure solar-wind ions with high resolution. The SWE is composed of two 150 deg spherical section analyzers using the same set of plates. The two acceptance fans are tilted with respect to each other so that 3D characteristics of the ion distributions can be derived.

Bame, S. J.↗

Hierarchical Control of Distributed Battery Energy Storage System in a DC Microgrid

This paper presents a novel hierarchical control approach of a DC microgrid (DCMG) which is supplied by a distributed battery energy storage system (BESS). With this approach, all battery units distributed in the BESS can be controlled to discharge with accurate current sharing and state-of-charge (SoC) balancing. Similar to other hierarchical control approaches used in DCMGs, this approach consists of three levels: (1) primary control, (2) secondary control and (3) tertiary control. This work includes defining a unit control error (UCE) at the secondary control level and evaluating current sharing weights at tertiary control level. A centralized controller at secondary control level is designed to detect the UCEs of each battery unit, and to restore the average voltage of a DCMG and control battery current sharing simultaneously. The distributed battery units share the load current in a DCMG based on weights. These weights are evaluated at the tertiary control level based on battery SoCs. The approach’s effectiveness was confirmed in digital simulation tests with the same simulation model as used in the NASA AMPS Modular Hardware Emulator.

Jing Zhang↗