Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scan report”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Effects of rare-earth doping on femtosecond laser waveguide writing in zinc polyphosphate glass

We have investigated waveguide writing in Er-Yb doped zinc polyphosphate glass using a femtosecond laser with a repetition rate of 1 KHz. We find that fabrication of good waveguides requires a glass composition with an O/P ratio of 3.25. The dependence on laser writing parameters including laser fluence, focusing conditions, and scan speed is reported. Waveguide properties together with absorption and emission data indicate that these glasses can be used for the fabrication of compact, high gain amplifying devices.

36 MATERIALS SCIENCE↗

Towards III-V solar cells on Si: Improvement in the crystalline quality of Ge-on-Si virtual substrates through low porosity porous silicon buffer layer and annealing

A comparison between the crystalline quality of Ge grown on bulk Si and on a low porosity porous Si (pSi) buffer layer using low energy plasma enhanced chemical vapor deposition is reported. Omega/2Theta coupled scans around the Ge and Si (004) diffraction peaks show a reduction of the Ge full-width at half maximum (FWHM) of 22.4% in presence of the pSi buffer layer, indicating it is effective in improving the epilayer crystalline quality. At the same time atomic force microscopy analysis shows an increase in root means square roughness for Ge grown on pSi from 38.5 nm to 48.0 nm, as a consequence of the larger surface roughness of pSi compared to bulk Si. The effect of 20 minutes vacuum annealing at 580°C is also investigated. The annealing leads to a FWHM reduction of 23% for Ge grown on Si and of 36.5% for Ge on pSi, resulting in a FWHM of 101 arcsec in the latter case. At the same time, the RMS roughness is reduced of 8.8% and of 46.5% for Ge grown on bulk Si and on pSi, respectively. The biggest improvement in the crystalline quality of Ge grown on pSi with respect to Ge grown on bulk Si observed after annealing is a consequence of the simultaneous reorganization of the Ge epilayer and the buffer layer driven by energy minimization. A low porosity buffer layer can thus be used for the growth of low defect density Ge on Si virtual substrates for the successive integration of III-V multijunction solar cells on Si. The suggested approach is simple and fast –thus allowing for high throughput-, moreover is cost effective and fully compatible with subsequent wafer processing. Finally it does not introduce new chemicals in the solar cell fabrication process and can be scaled to large area silicon wafers.

36 MATERIALS SCIENCE↗

Structural phases driven by oxygen vacancies at the La{sub 0.7}Sr{sub 0.3}MnO{sub 3}/SrTiO{sub 3} hetero-interface

An oxygen vacancy driven structural response at the epitaxial interface between La{sub 0.7}Sr{sub 0.3}MnO{sub 3} films and SrTiO{sub 3} substrates is reported. A combined scanning transmission electron microscopy and electron energy loss spectroscopy study reveal the presence of an elongated out-of-plane lattice parameter, coupled to oxygen vacancies and reduced manganese oxidation state at the La{sub 0.7}Sr{sub 0.3}MnO{sub 3} side of the interface. Density functional theory calculations support that the measured interface structure is a disordered oxygen deficient brownmillerite structure. The effect of oxygen vacancy mobility is assessed, revealing an ordering of the vacancies with time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of TiO{sub 2} nanotubes as an implant application

Vertically aligned TiO{sub 2} nanotubes have become the primary candidates for implant materials that can provide direct control of cell behaviors. In this work, 65 nm inner diameters of TiO{sub 2} nanotubes were successfully prepared by anodization method. The interaction of bone marrow stromal cells (BMSC) in term of cell adhesion and cell morphology on bare titanium and TiO{sub 2} nanotubes is reported. Field emission scanning electron microscopy (FESEM) analysis proved interaction of BMSC on TiO{sub 2} nanotubes structure was better than flat titanium (Ti) surface. Also, significant cell adhesion on TiO{sub 2} nanotubes surface during in vitro study revealed that BMSC prone to attach on TiO{sub 2} nanotubes. From the result, it can be conclude that TiO{sub 2} nanotubes are biocompatible to biological environment and become a new generation for advanced implant materials.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Low temperature absolute internal quantum efficiency of InGaN-based light-emitting diodes

A method to reveal low temperature absolute internal quantum efficiency of an InGaN-based light-emitting diode (LED) is reported. Structural (via scanning electron and atomic force microscopies, x-ray diffraction, and Raman spectroscopy) and optical (via temperature- and power-dependent photoluminescence) properties of InGaN-based blue LEDs are coupled with a channel-based recombination model, which reveals the low temperature absolute internal quantum efficiency of the LED on traditional sapphire and emerging Si (111) substrates as 27.5% and 71.1%, respectively. High low-temperature absolute internal quantum efficiency of the former is attributed to its lower defect density and less strain. Furthermore, our results show assuming perfect (i.e., 100%) internal quantum efficiency in an InGaN-based LED at low temperatures could be misleading, and using negative thermal quenching properties of defect luminesce bands with a channel-based recombination model can be a method to quantify LED's less than ideal low temperature internal quantum efficiencies.

36 MATERIALS SCIENCE↗

Electrical Mobility Spectrometer Using a Diethylene Glycol Condensation Particle Counter for Measurement of Aerosol Size Distributions Down to 1 nm

We report a new scanning mobility particle spectrometer (SMPS) for measuring number size distributions of particles down to {approx}1 nm mobility diameter. This SMPS includes an aerosol charger, a TSI 3085 nano differential mobility analyzer (nanoDMA), an ultrafine condensation particle counter (UCPC) using diethylene glycol (DEG) as the working fluid, and a conventional butanol CPC (the 'booster') to detect the small droplets leaving the DEG UCPC. The response of the DEG UCPC to negatively charged sodium chloride particles with mobility diameters ranging from 1-6 nm was measured. The sensitivity of the DEG UCPC to particle composition was also studied by comparing its response to positively charged 1.47 and 1.70 nm tetra-alkyl ammonium ions, sodium chloride, and silver particles. A high resolution differential mobility analyzer was used to generate the test particles. These results show that the response of this UCPC to sub-2 nm particles is sensitive to particle composition. The applicability of the new SMPS for atmospheric measurement was demonstrated during the Nucleation and Cloud Condensation Nuclei (NCCN) field campaign (Atlanta, Georgia, summer 2009). We operated the instrument at saturator and condenser temperatures that allowed the efficient detection of sodium chloride particles but not of air ions having the same mobility. We found that particles as small as 1 nm were detected during nucleation events but not at other times. Factors affecting size distribution measurements, including aerosol charging in the 1-10 nm size range, are discussed. For the charger used in this study, bipolar charging was found to be more effective for sub-2 nm particles than unipolar charging. No ion induced nucleation inside the charger was observed during the NCCN campaign.

54 ENVIRONMENTAL SCIENCES↗

Spectroscopic evidence for spin-polarized silicon atoms on Si(553)-Au

The stepped Si(553)-Au surface undergoes a $1\times3$ reconstruction at low temperature which has recently been interpreted theoretically as the $\times3$ ordering of spin-polarized silicon atoms along a step edge in each surface unit cell. This predicted magnetic ground state has a clear spectroscopic signature---a silicon step-edge state at $0.5$ eV above the Fermi level---that arises from strong exchange splitting and hence would not occur without spin polarization. Here we report spatially resolved scanning tunneling spectroscopy data for Si(553)-Au that reveal key differences in the unoccupied step-edge density of states between room temperature and $40$ K. At low temperature we find an unoccupied state at 0.55 eV above every third step-edge silicon atom, in excellent agreement with the spin-polarized ground state predicted theoretically.

Snijders, Paul C↗

Finding the hidden valence band of N = 7 armchair graphene nanoribbons with angle-resolved photoemission spectroscopy

To understand the optical and transport properties of graphene nanoribbons, an unambiguous determination of their electronic band structure is needed. In this work we demonstrate that the photoemission intensity of each valence sub-band, formed due to the quantum confinement in quasi-one-dimensional (1D) graphene nanoribbons, is a peaked function of the two-dimensional (2D) momentum. We resolve the long-standing discrepancy regarding the valence band effective mass (m* VB ) of armchair graphene nanoribbons with a width of N = 7 carbon atoms (7-AGNRs). In particular, angle-resolved photoemission spectroscopy (ARPES) and scanning tunneling spectroscopy report m* VB ≈0.2 and ≈0.4 of the free electron mass (m e ), respectively. ARPES mapping in the full 2D momentum space identifies the experimental conditions for obtaining a large intensity for each of the three highest valence 1D sub-bands. Our detail map reveals that previous ARPES experiments have incorrectly assigned the second sub-band as the frontier one. The correct frontier valence sub-band for 7-AGNRs is only visible in a narrow range of emission angles. For this band we obtain an ARPES derived effective mass of 0.4 m e , a charge carrier velocity in the linear part of the band of 0.63 x 10 6 m s -1 and an energy separation of only ≈60 meV to the second sub-band. Lastly, our results are of importance not only for the growing research field of graphene nanoribbons but also for the community, which studies quantum confined systems.

36 MATERIALS SCIENCE↗

CarbonSafe TR McMillen-2

Computed tomography and core logger data described in Technical Report "Computed Tomography Scanning and Geophysical Measurements of the T.R. McMillen #2 Core" by R. Schmitt et al, 2020.

CarbonSAFE↗

ISGS Seal wells

Computed tomography and core logger data described in Technical Report "Computed Tomography Scanning and Geophysical Measurements of the CarbonSAFE Seal Integrity Wells in the Illinois Basin" by Paronish et al., 2023

carbon storage↗

CORECM Williston Basin Twin Butte and Hagel Coal Wells

Computed tomography and core logger data described in Technical Report "Computed Tomography Scanning and Petrophysical Measurements of Eastern Williston Basin Twin Buttes and Hagel Formations" by Paronish et al., 2024

Coal↗

WARE 1-9 Well

Computed tomography and core logger data described in Technical Report "Computed Tomography Scanning and Geophysical Measurements of the J. F. WARE Gas Unit 1-9 Well in Smith County, Texas" by Brinza et al. , 2024.

CoreCM↗

Interstellar polarization in the ultraviolet

Ultraviolet interstellar polarization measurements in the direction of Zed Ophiuchi by rocket-borne scanning spectrophotometer are reported. The spectrophotometer was calibrated by a beam of polarized light. Plotted percent polarization against inverse wavelength in microns shows that polarization is running around 1.5 percent for this star, which is consistent with the visual observation.

Stecher, T. P.↗

Cooled slow-scan performance of a 512 by 320 element charge-coupled imager

A 512 x 320 element charge coupled imager has been fabricated and tested under cooled slow scan conditions to evaluate the device's performance under a variety of long integration and slow scan readout conditions. Operation in a low blooming mode of operation enables the sensor to be exposed with portions of the image heavily overexposed, without those areas spreading into adjacent picture areas. Device design, layout, and operating mode are described, and presents experimental results, including displayed images taken under cooled slow scan operation, are reported.

Rodgers, R. L., III↗

SETI Investigations at Jodrell Bank, England: September Through November 1983

The radiofrequency interference RFI environment was examined in the frequency band 1404 to 1444 MHz using the DSN Advanced Systems' Radio Frequency Interference Surveillance System. An uncooled FET amplifier was placed on the 12.8-m antenna, and unlimited observing time was made available to the SETI project. One night of observing at 1667 MHz was made available on the 76 m antenna. Preliminary results of four investigations are reported: (1) full scans of the horizon, cataloging RFI events between 1404 and 1444 MHz; (2) lunar reflections of terrestrial RFI signals between 1424 and 1444 MHz; (3) noise background distortions caused by galactic neutral hydrogen emission at 1420.4 MHz; and (4) low sensitivity search for spectral features of F, G, and K stars.

Downs, G. S.↗

Time series comparisons of satellite and rocketsonde temperatures in 1978-1979

The Limb Infrared Monitor of the Stratosphere (LIMS) experiment on Nimbus 7 yielded temperature-versus-pressure (T(p)) profiles for each radiance scan. The present report describes time series comparisons between LIMS and rocketsonde T(p) values at rocketsonde station locations. Sample size has increased up to 665 by this new approach, leading to better statistics for a T(p) validation. The results indicate no clearly significant bias for LIMS versus Datasonde from 10 kPa at low and mid latitudes. There is a positive LIMS bias of 2 to 3 K in the upper stratosphere at high latitudes for the Northern Hemisphere in both winter and spring. LIMS is progressively colder than Datasonde from 0.4 kPa (about -3 K) to 0.1 kPa (about -9 K) at all latitudes. A similar comparison between LIMS and the more accurate falling sphere measurements reveals an equivalent mid-latitude LIMS bias at 0.4 kPa but a much smaller bias at 0.1 kPa (-4.6 K). Because the biases do not vary noticeably with season, it is concluded that they are not a function of atmospheric state. This result confirms the robustness of the LIMS temperature retrieval technique.

Remsberg, Ellis E.↗

Molecular beam epitaxy of bilayer Bi(111) films on topological insulator Bi{sub 2}Te{sub 3}: A scanning tunneling microscopy study

We report on molecular beam epitaxy growth of bilayer Bi(111) films on topological insulator Bi{sub 2}Te{sub 3}. In situ scanning tunneling microscopy/spectroscopy shows that Bi growth mode changes from quasi bilayer-by-bilayer to step-flow with increasing substrate temperature. Bilayer Bi(111) exhibits an electron donor behavior, causing an 80 meV downshift of the Dirac point of Bi{sub 2}Te{sub 3}. Local work function difference between the bilayer films and Bi{sub 2}Te{sub 3} films is measured to be 390 meV. Based on the observations, we propose a schematic energy-band diagram which reveals band bending effect at the Bi/Bi{sub 2}Te{sub 3} interface. Our work paves a way to explore the exotic topological properties of bilayer islands and thin films of Bi.

36 MATERIALS SCIENCE↗

Chemical Composition Analysis for X-Ray Transport Container Scans

It is important for national security to control the movement of dangerous or strategically cargo such as explosives, radioactive materials, rare and precious metals. This control can be provided by scanning transport containers by gamma rays. In this report the existing technique for scanning (dual energy method) is considered and the alternative method based on measuring the energy distribution of gamma rays is proposed. For estimation perspectives of the proposing method, the corresponding simulation was conducted by using the GEANT4 toolkit. The example of the algorithm of reconstruction the chemical composition of the scanned object is also considered. In addition the experiment for estimation energy resolution of the detector based on a scintillation crystal BGO and SiPM was carried out.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗