Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sampler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A Comparison of Groundwater Sampling Technologies, Including Passive Diffusion Sampling, for Radionuclide Contamination - 20205

Using traditional high-flow purge methods for long-term water quality monitoring of deep groundwater wells can be expensive, affect contaminant migration, and produce excessive volumes of discharge water that can be difficult to manage. The use of low-flow pumping methods and depth discrete bailers (DDBs) can reduce the cost of sampling deep groundwater wells. In general, using different pumping methods to obtain reproducible and representative groundwater can be challenging. Passive diffusion samplers (PDSs) have successfully been used in long-term monitoring for volatile organic compounds, major ions, and trace-elements, but application has been limited for stable and radioactive isotopes. Beginning in 2018, the United States Geological Survey (USGS) conducted three sampling events to test the ability of PDSs and DDBs to obtain reproducible and representative groundwater samples. The sampled well is completed in a regional, permeable carbonate aquifer and is one in a set of wells that have historically been used for tritium tracer testing. All samples were obtained at 180 m (590 ft) below land surface (bls) in a 13.97 cm (5.5 inch) uncased well that has a total depth of 202 m (662 ft) bls. The first sampling event deployed a regenerated cellulose dialysis membrane (RCDM) PDS for 14 days with deionized water as the blank. The second sampling event deployed a RCDM for 27 days also with deionized water as the blank. The third sampling event deployed a Dual Membrane (DM) PDS for 65 days using a blank of tritium-dead carbonate water. The DM PDS was used to assess the effect of longer term deployment on tritium concentrations and address whether or not the PDSs reached equilibrium with ambient groundwater. The day after each of the three passive samplers were retrieved a DDB was used to obtain discrete non-integrated groundwater samples. For each DDB sampling day, the bailer was lowered into the well 10 consecutive times to determine if the water chemistry changed from the first to the last bailed sample. Quality assurance samples including blanks and duplicates were obtained during all three sampling events. All blank waters had tritium concentrations less than 21±33 pCi/L. Major ion (e.g. calcium, chloride, sodium, and sulfate) results were compared between all samples obtained with RCDM and DDB. Major ion concentrations showed a coefficient of variation of less than 6% between all RCDM and DDB samples; however, the coefficient of variation between the different deployment times and the two different methods for trace-element concentrations was much larger, particularly for manganese (82%), lead (41%), and zinc (33%). Stable isotope values were compared between the RCDM and DDB samples. The DDB sample results all fell within analytical uncertainty and were considered representative of the formation groundwater. The stable isotope values from the RCDM samples indicated that a longer deployment time was necessary to gain equilibrium and to obtain representative groundwater samples. Tritium results from groundwater samples obtained from the RCDM, DM, and DDB indicate that groundwaters obtained with PDSs produced tritium concentrations 2 to 3 times higher (between 1,426 and 3,060±87 pCi/L) than groundwaters obtained with a DDB (479 to 1,219±51 pCi/L). The longer the passive diffusion samplers were deployed, the higher the tritium concentration, suggesting that equilibrium with tritium was not reached within a 27-day deployment. DDB samples showed tritium results declining from the first to the last bailed sample for all three sampling events. This research suggests that tritium results from groundwater samples obtained from PDSs are more reproducible than samples obtained from DDBs. Also, PDSs likely do not accumulate isotopes of water but rather equilibrate with the ambient groundwater. On the other hand, both PDSs and DDBs were able to provide representative groundwater samples for major ions and have the potential to produce representative groundwater samples for stable isotopes of water (δD and δ{sup 18}O). Utilizing the most effective method for sampling groundwater is important for long-term groundwater monitoring. Quantifying the ability of passive diffusion groundwater samplers to obtain representative radioactive chemistry samples will help determine if these methods can be a useful alternative to pumping and purging wells for long-term monitoring. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Robust sampling for weak lensing and clustering analyses with the Dark Energy Survey

Recent cosmological analyses rely on the ability to accurately sample from high-dimensional posterior distributions. A variety of algorithms have been applied in the field, but justification of the particular sampler choice and settings is often lacking. Here, we investigate three such samplers to motivate and validate the algorithm and settings used for the Dark Energy Survey (DES) analyses of the first 3 yr (Y3) of data from combined measurements of weak lensing and galaxy clustering. We employ the full DES Year 1 likelihood alongside a much faster approximate likelihood, which enables us to assess the outcomes from each sampler choice and demonstrate the robustness of our full results. We find that the ellipsoidal nested sampling algorithm multinest reports inconsistent estimates of the Bayesian evidence and somewhat narrower parameter credible intervals than the sliced nested sampling implemented in polychord. We compare the findings from multinest and polychord with parameter inference from the Metropolis–Hastings algorithm, finding good agreement. We determine that polychord provides a good balance of speed and robustness for posterior and evidence estimation, and recommend different settings for testing purposes and final chains for analyses with DES Y3 data. Our methodology can readily be reproduced to obtain suitable sampler settings for future surveys.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Salt Sampling FY21 Technical Report

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches to enable high-precision in-process salt sample analysis to improve the timeliness of sampling-based accountancy measurements. Tools currently under development in support of this goal include (1) a modular vacuum sampler with an accompanying sample handling method for coupling vacuum sampling with high-precision at-line sample analysis, (2) a pneumatic sample generator that enables high-throughput sample analysis to improve the precision of existing analytical techniques, and (3) a windowless flow cell to enable on-line optical analysis of molten salt in a sampling loop. Compared to point sampling approaches (i.e., dip probes), vacuum sampling systems and on-line sampling loops facilitate access to a larger cross-section of a process fluid. This is known to improve the characterization of the process fluid by producing more representative samples and by enabling the analysis of a larger cross section of the fluid. A vacuum sampling approach for molten salts eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. In FY21, two methods for integrating a vacuum sampler with a pneumatic sample generator were tested. These included direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the extreme conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampler and pneumatic sample generator, respectively. While the charging mechanism will be deployed in FY22, the tube transfer method and discharge mechanism were tested in FY21. These were deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The method was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques. This will enable significant reductions in the time delay for sampling-based accountancy measurements by eliminating the need for manual off-line sample processing and analysis. On-line optical analysis of molten salt in a sampling loop would provide complementary information to at-line and in-situ techniques. In FY21, an open-aperture molten salt gravity flow cell with windowless optical access to flowing salt was successfully demonstrated. Future work should include the refinement and performance testing of the on-line and at-line sampling tools, integration of additional analysis techniques, stakeholder outreach and collaboration, evaluation of the integrated methods, and analyses to determine how the various tools might fit into an integrated safeguards monitoring system of unattended near real time monitoring tools.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of membrane filter field monitors for microbiological air sampling

Due to area constraints encountered in assembly and testing areas of spacecraft, the membrane filter field monitor (MF) and the National Aeronautics and Space Administration-accepted Reyniers slit air sampler were compared for recovery of airborne microbial contamination. The intramural air in a microbiological laboratory area and a clean room environment used for the assembly and testing of the Apollo spacecraft was studied. A significantly higher number of microorganisms was recovered by the Reyniers sampler. A high degree of consistency between the two sampling methods was shown by a regression analysis, with a correlation coefficient of 0.93. The MF samplers detected 79% of the concentration measured by the Reyniers slit samplers. The types of microorganisms identified from both sampling methods were similar.

Fields, N. D.↗

Electrets used in measuring rocket exhaust effluents from the space shuttle's solid rocket booster during static test firing, DM-3

The purpose of this experimental research was to compare Marshall Space Flight Center's electrets with Thiokol's fixed flow air samplers during the Space Shuttle Solid Rocket Booster Demonstration Model-3 static test firing on October 19, 1978. The measurement of rocket exhaust effluents by Thiokol's samplers and MSFC's electrets indicated that the firing of the Solid Rocket Booster had no significant effect on the quality of the air sampled. The highest measurement by Thiokol's samplers was obtained at Plant 3 (site 11) approximately 8 km at a 113 degree heading from the static test stand. At sites 11, 12, and 5, Thiokol's fixed flow air samplers measured 0.0048, 0.00016, and 0.00012 mg/m3 of CI. Alongside the fixed flow measurements, the electret counts from X-ray spectroscopy were 685, 894, and 719 counts. After background corrections, the counts were 334, 543, and 368, or an average of 415 counts. An additional electred, E20, which was the only measurement device at a site approximately 20 km northeast from the test site where no power was available, obtained 901 counts. After background correction, the count was 550. Again this data indicate there was no measurement of significant rocket exhaust effluents at the test site.

Susko, M.↗

Semivolatile Particulate Organic Material Southern Africa during SAFARI 2000

During August and September 2000, the University of Washington's Cloud and Aerosol Research Group (CARG) with its Convair-580 research aircraft participated in the Southern African Fire-Atmosphere Research Initiative (SAFARI) 2000 field study in southern Africa. Aboard this aircraft was a Particle Concentrator-Brigham Young University Organic Sampling System (PC-BOSS), which was used to determine semivolatile particulate material with a diffusion denuder sampler. Denuded quartz filters and sorbent beds in series were used to measure nonvolatile and semivolatile materials, respectively. Results obtained with the PC-BOSS are compared to those obtained with conventional quartz-quartz and Teflon-quartz filter pack samplers. Various 10-120 min integrated samples were collected during flights through the h e troposphere, in the atmospheric boundary layer, and in plumes from savanna fires. Significant fine particulate semivolatile organic compounds (SVOC) were found in all samples. The SVOC was not collected by conventional filter pack samplers and therefore would not have been determined in previous studies that used only filter pack samplers. The SVOC averaged 24% of the fine particulate mass in emissions from the fires and 36% of the fine particulate mass in boundary layer samples heavily impacted by aged emissions from savanna fires. Concentrations of fine particulate material in the atmospheric mixed layer heavily impacted by aged savanna frre emissions averaged 130 micrograms per cubic meter. This aerosol was 85% carbonaceous mated.

Eatough, D. J.↗

Aerosol Sampling Experiment on the International Space Station

The International Space Station (ISS) is a unique indoor environment which serves as both home and workplace to the astronaut crew. There is currently no particulate monitoring, although particulate matter requirements exist. An experiment to collect particles in the ISS cabin was conducted recently. Two different aerosol samplers were used for redundancy and to collect particles in two size ranges spanning from 10 nm to hundreds of micrometers. The Active Sampler is a battery operated thermophoretic sampler with an internal pump which draws in air and collects particles directly on a transmission electron microscope grid. This commercial-off-the-shelf device was modified for operation in low gravity. The Passive Sampler has five sampling surfaces which were exposed to air for different durations in order to collect at least one sample with an optimal quantity of particles for microscopy. These samples were returned to Earth for analysis with a variety of techniques to obtain long-term average concentrations and identify particle emission sources. Results are compared with the inventory of ISS aerosols which was created based on sparse data and the literature. The goal of the experiment is to obtain data on indoor aerosols on ISS for future particulate monitor design and development.

Aerosol↗

Collection, release, and detection of analytes with polymer composite sampling materials

A unique fiber core sampler composition, related systems, and techniques for designing, making, and using the same are described. The sampler is used to interface with existing field instrumentation, such as Ion Mobility Spectrometer (IMS) equipment. Desired sampler characteristics include its: stiffness/flexibility; thermal mass and conductivity; specific heat; trace substance collection/release dependability, sensitivity and repeatability; thickness; reusability; durability; stability for thermal cleaning; and the like. In one form the sampler has a glass fiber core with a thickness less than 0.3 millimeter that is coated with a polymer including one or more of: polymeric organofluorine, polyimide, polyamide, PolyBenzlmidazole (PBI), PolyDiMethylSiloxane (PDMS), sulfonated tetrafluoroethylene (PFSA) and Poly(2,6-diphenyl-p-phenylene Oxide) (PPPO). Multiple polymer coatings with the same or different polymer types may be included, core/substrate surface functionalization utilized, and/or the core/substrate may be at partially filled with thermally conductive particles.

Addleman, Raymond S.↗

A Look At Dissolved Organic Carbon In Streams and Its Effect On DGT Hg Collection

Savannah River Site (SRS) and Oak Ridge National Laboratory (ORNL) were both major material production sites for the U.S.'s nuclear program during the 20. century. Both sites discharged mercury (Hg) to streams. Oak Ridge streams have accumulated significant levels of Hg from early 'historical' discharges. Diffusive Gradient in Thin Films (DGT) samplers may be a labor and material saving method to monitor the Hg contamination of streams at both sites. Humic and Fulvic acids are released during the degradation of plant and animal residue. They are part of the Dissolved Organic Matter that colors the black water streams of the southern U.S.. Humic acid and Fulvic acids have a tendency to sequester heavy metals, like Hg, and may interfere with the reactions needed to draw the Hg through the thin films of the DGT samplers. Project Objective: Use a UV-Vis spectrophotometer to estimate the levels of Dissolved Organic Carbon (DOC) in the streams selected to test the effect of DOC on DGT samplers. Conclusion: UV-Vis is a convenient way to estimate the amount of DOC in streams and may be used to provide more context in DGT Hg sampling. efforts. Future Work: Analyze data from SRS and ORNL DGT samples; Compare the results of the DGT samplers with more traditional speciating methods from ORNL; Use a TOC Spectrophotometer to gain a more accurate picture of stream DOC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sequential Kalman tuning of the t -preconditioned Crank-Nicolson algorithm: efficient, adaptive and gradient-free inference for Bayesian inverse problems

Ensemble Kalman Inversion (EKI) has been proposed as an efficient method for the approximate solution of Bayesian inverse problems with expensive forward models. However, when applied to the Bayesian inverse problem EKI is only exact in the regime of Gaussian target measures and linear forward models. Here, in this work we propose embedding EKI and Flow Annealed Kalman Inversion, its normalizing flow (NF) preconditioned variant, within a Bayesian annealing scheme as part of an adaptive implementation of the t-preconditioned Crank-Nicolson (tpCN) sampler. The tpCN sampler differs from standard pCN in that its proposal is reversible with respect to the multivariate t-distribution. The more flexible tail behaviour allows for better adaptation to sampling from non-Gaussian targets. Within our Sequential Kalman Tuning (SKT) adaptation scheme, EKI is used to initialize and precondition the tpCN sampler for each annealed target. The subsequent tpCN iterations ensure particles are correctly distributed according to each annealed target, avoiding the accumulation of errors that would otherwise impact EKI. We demonstrate the performance of SKT for tpCN on three challenging numerical benchmarks, showing significant improvements in the rate of convergence compared to adaptation within standard SMC with importance weighted resampling at each temperature level, and compared to similar adaptive implementations of standard pCN. The SKT scheme applied to tpCN offers an efficient, practical solution for solving the Bayesian inverse problem when gradients of the forward model are not available. Code implementing the SKT schemes for tpCN is available at https://github.com/RichardGrumitt/KalmanMC.

97 MATHEMATICS AND COMPUTING↗

High-Dimensional Bayesian Optimization via Semi-Supervised Learning with Optimized Unlabeled Data Sampling

We introduce a novel semi-supervised learning approach, named Teacher-Student Bayesian Optimization (TSBO ), integrating the teacher-student paradigm into BO to minimize expensive labeled data queries for the first time. TSBO incorporates a teacher model, an unlabeled data sampler, and a student model. The student is trained on unlabeled data locations generated by the sampler, with pseudo labels predicted by the teacher. The interplay between these three components implements a unique selective regularization to the teacher in the form of student feedback. This scheme enables the teacher to predict high-quality pseudo labels, enhancing the generalization of the GP surrogate model in the search space. To fully exploit TSBO , we propose two optimized unlabeled data samplers to construct effective student feedback that well aligns with the objective of Bayesian optimization. Furthermore, we quantify and leverage the uncertainty of the teacher-student model for the provision of reliable feedback to the teacher in the presence of risky pseudo-label predictions. TSBO demonstrates significantly improved sample-efficiency in several global optimization tasks under tight labeled data budgets. The implementation is available at https://github.com/reminiscenty/TSBO-Official.

Yin, Yuxuan↗

Unlimbering Viking's scoop

A number of difficulties which were encountered in deploying the Viking 1 lander's surface-sampler arm are discussed. When the surface sampler jammed during its initial operation, the problem was studied with the aid of tests on a full-scale lander mock-up. It was found that the difficulty was caused by a boom latch pin which had failed to fall clear. The surface-sampler arm could subsequently be freed by modifying the original command sequence. Another difficulty could be overcome by a similar approach.

Spitzer, C. R.↗

Description and field test of an in situ coliform monitoring system

A prototype in situ system for monitoring the levels of fecal coliforms in shallow water bodies was developed and evaluated. This system was based on the known relationship between the concentration of the coliform bacteria and the amount of hydrogen they produce during growth in a complex organic media. The prototype system consists of a sampler platform, which sits on the bottom; a surface buoy, which transmits sampler-generated data; and a shore station, which receives, displays the data, and controls the sampler. The concept of remote monitoring of fecal coliform concentrations by utilizing a system based on the electrochemical method was verified during the evaluation of the prototype.

Grana, D. C.↗

Volcanic impact on stratospheric aerosol chemistry

Samples collected by the National Center for Atmospheric Research (NCAR) using the multiple-filter sampler on the U-2 were analyzed. The sampler is capable of exposing a number of 110 mm filters in sequence to ram air flow. Two types of filters, IPC cellulose and polystrene, were used, both of which have high blank levels for the trace elements determined. The levels of most trace elements in the stratosphere are so low under normal circumstances that none can be seen. Results from the eruption of Mt. St. Helens, a mystery cloud (probably volcanic in origin) in 1982, and the El Chichonal eruption in 1983 are discussed. To improve the collection of particles for chemical analysis, a new sampling system was developed for use on the U-2. The sampler consisted of an electrostatic collection of particles between 1 and 0.001 micron diameter dierectly onto electron microscopic grids, followed by a thermal precipitation for the smaller particles. The system was built and tested in the laboratory, but never flown on the U-2.

Zoller, W. H.↗

How successful were the lunar sampling tools: Implications for sampling Mars

Like the Mars Sample Return endeavor, the Apollo lunar-sample program began with definition of strategy for sample collection and of scientific requirements for sampling hardware design. Several lessons can be illustrated by specific tools. The evolution of drive tubes from narrow 2 cm diameter, thick-walled tubes (used on Apollo 11, 12 and 14) to 4 cm diameter, thin-walled tubes used on Apollo 15, 16, and 17) as an example of the improvements made possible during multiple missions. The original Apollo 11 drive tube was designed to work in fluffy soil; thus, only 50 percent of the relatively dense lunar soil was recovered, and the core was distorted. The final configuration resulted in nearly 100 pct recovery with little distortion. The surface samplers (Contact Soil Sampling Devices) were designed to collect the upper 100 micrometer or the upper 1 mm of soil. It was over 2 years after the mission before these particularly specific samplers were opened because interest in them waned. Both core tubes and surface samplers were difficult to open in the laboratory. The Apollo Lunar Sample Return Containers (ALSRCs) were constructed with one indium and 2 Viton seals. They were closed on the lunar surface. Interior container pressures measured upon return to the laboratory indicate that these seals were not reliable in the lunar environment. Also, choice of indium as a sealing material interfered with siderophile analyses of samples.

Allton, J. H.↗

A Side by Side Comparison of Filter-Based PM(sub 2.5) Measurements at a Suburban Site: A Closure Study

Reliable determination of the effects of air quality on public health and the environment requires accurate measurement of PM(sub 2.5) mass and the individual chemical components of fine aerosols. This study seeks to evaluate PM(sub 2.5) measurements that are part of a newly established national network by comparing them with a more conventional sampling system. Experiments were carried out during 2002 at a suburban site in Maryland, United States, where two samplers from the U.S. Environmental Protection Agency (USEPA) Speciation Trends Network: Met One Speciation Air Sampling System STNS and Thermo Scientific Reference Ambient Air Sampler STNR, two Desert Research Institute Sequential Filter Samplers DRIF, and a continuous TEOM monitor (Thermo Scientific Tapered Element Oscillating Microbalance) were sampling air in parallel. These monitors differ not only in sampling configuration but also in protocol-specific sample analysis procedures. Measurements of PM(sub 2.5) mass and major contributing species were well correlated among the different methods with r-values > 0.8. Despite the good correlations, daily concentrations of PM(sub 2.5) mass and major contributing species were significantly different at the 95% confidence level from 5 to 100% of the time. Larger values of PM(sub 2.5) mass and individual species were generally reported from STNR and STNS. The January STNR average PM(sub 2.5) mass (8.8 (micro)g/per cubic meter) was 1.5 (micro)g/per cubic meter larger than the DRIF average mass. The July STNS average PM(sub 2.5) mass (27.8 (micro)g/per cubic meter) was 3.8 (micro)g/per cubic meter larger than the DRIF average mass. These differences can only be partially accounted for by known random errors. Variations in flow control, face velocity, and sampling artifacts likely influence the measurement of PM(sub 2.5) speciation and mass closure. Simple statistical tests indicate that the current uncertainty estimates used in the STN network may underestimate the actual uncertainty.

Haines, Jennifer C.↗

Integrated Modeling of Spacecraft Touch-and-Go Sampling

An integrated modeling tool has been developed to include multi-body dynamics, orbital dynamics, and touch-and-go dynamics for spacecraft covering three types of end-effectors: a sticky pad, a brush-wheel sampler, and a pellet gun. Several multi-body models of a free-flying spacecraft with a multi-link manipulator driving these end-effectors have been tested with typical contact conditions arising when the manipulator arm is to sample the surface of an asteroidal body. The test data have been infused directly into the dynamics formulation including such information as the mass collected as a function of end-effector longitudinal speed for the brush-wheel and sticky-pad samplers, and the mass collected as a function of projectile speed for the pellet gun sampler. These data represent the realistic behavior of the end effector while in contact with a surface, and represent a low-order model of more complex contact conditions that otherwise would have to be simulated. Numerical results demonstrate the adequacy of these multibody models for spacecraft and manipulator- arm control design. The work contributes to the development of a touch-and-go testbed for small body exploration, denoted as the GREX Testbed (GN&C for Rendezvous-based EXploration). The GREX testbed addresses the key issues involved in landing on an asteroidal body or comet; namely, a complex, low-gravity field; partially known terrain properties; possible comet outgassing; dust ejection; and navigating to a safe and scientifically desirable zone.

Quadrelli, Marco↗

Culture-Independent Microbial Air Profiling using a Spaceflight-Compatible Nanopore Sequencing Method

Microbial monitoring of spacecraft air is critical toward assessing the efficacy of microbial controls within the environmental control and life support systems to protect both the crew and the vehicle environment. Additionally, understanding of the atmospheric microbial profiles will be essential toward Mars-forward planetary protection planning. Currently, onboard the International Space Station (ISS), the air is monitored on a quarterly basis using an impaction air sampler. With this method, bacterial and fungal cells and spores are pulled onto plates containing growth medium. Following five days of ambient incubation onboard the ISS, the crew compares the growth to density charts and provides the approximations to the ground. Upon return of the culture plates to the Johnson Space Center’s Microbiology Laboratory, the isolates present are identified for crew health risk assessments. As NASA moves beyond the low-Earth orbit of ISS, sample return will be impractical. As such, a near real-time monitoring capability for the assessment of the spacecraft atmosphere is necessary. Significant strides have been made in recent years to utilize a molecular-based method for microbial profiling of ISS surfaces. The developed method is not dependent on microbial culture, thus removing the associated risk to the crew from high microbial levels, the bias toward detecting only the culturable organisms, and eliminates the need for sample return. The work described here details the evaluation of three different air sampling platforms whose product is amenable to downstream molecular processing and nanopore sequencing. The three samplers were compared in terms of mass and power requirements, ease-of -use, and the resulting data. For the two highest ranking samplers, a basic concept of operations was developed to transfer the sample into the already established preparation and sequencing process. Using these concepts of operations, an in-depth comparison of the molecular data generated was compared to the historical culture-based method. Data from both methods detailed similar microbial profiles, while the molecular method detailed microbial identifications that could not be identified through the culture-based method. The developed method will enable the generation of near real-time microbial profiles of the spacecraft atmosphere.

Brandon J Dunbar↗