Feasibility of determining flat roof heat losses using aerial thermography

The utility of aerial thermography for determining rooftop heat losses is investigated. Actual rooftop heat losses were obtained both from in-situ instrumentation of test roofs with known thermal resistances and aerial thermography obtained from overflights at an altitude of 305 m. It is found that the roof heat losses calculated using the remotely determined roof temperature agreed to within 17% of those calculated from ground measurements. However it is noted that an acceptable quantitative determination of roof heat losses using aerial thermography is only feasible when the convective term is accurately known or minimized. In addition, the sensitivity of the heat loss determination to environmental conditions is also evaluated. Finally, the analysis shows that the most reliable determinations can probably be obtained under conditions of total cloud cover with low wind speeds and at low ambient temperatures.

Bowman, R. L.↗

Cost comparison of competing local distribution systems for communication satellite traffic

The boundaries of market areas which favor various means for distributing communications satellite traffic are considered. The distribution methods considered are: control Earth station with cable access, rooftop Earth stations, Earth station with radio access, and various combinations of these methods. The least cost system for a hypothetical region described by number of users and the average cable access mileage is discussed. The region is characterized by a function which expresses the distribution of users. The results indicate that the least cost distribution is central Earth station with cable access for medium to high density areas of a region combined with rooftop Earth stations or (for higher volumes) radio access for remote users.

Dopfel, F. E.↗

Locating buildings in aerial photos

Algorithms and techniques for use in the identification and location of large buildings in digitized copies of aerial photographs are developed and tested. The building data would be used in the simulation of objects located in the vicinity of an airport that may be detected by aircraft radar. Two distinct approaches are considered. Most building footprints are rectangular in form. The first approach studied is to search for right-angled corners that characterize rectangular objects and then to connect these corners to complete the building. This problem is difficult because many nonbuilding objects, such as street corners, parking lots, and ballparks often have well defined corners which are often difficult to distinguish from rooftops. Furthermore, rooftops come in a number of shapes, sizes, shadings, and textures which also limit the discrimination task. The strategy used linear sequences of different samples to detect straight edge segments at multiple angles and to determine when these segments meet at approximately right-angles with respect to each other. This technique is effective in locating corners. The test image used has a fairly rectangular block pattern oriented about thirty degrees clockwise from a vertical alignment, and the overall measurement data reflect this. However, this technique does not discriminate between buildings and other objects at an operationally suitable rate. In addition, since multiple paths are tested for each image pixel, this is a time consuming task. The process can be speeded up by preprocessing the image to locate the more optimal sampling paths. The second approach is to rely on a human operator to identify and select the building objects and then to have the computer determine the outline and location of the selected structures. When presented with a copy of a digitized aerial photograph, the operator uses a mouse and cursor to select a target building. After a button on the mouse is pressed, with the cursor fully within the perimeter of the building, the program scans from the position of the cursor to a perimeter position where a shift in grayscale is detected. Once at the perimeter, the process traces along it, around the building, until it eventually returns to the perimeter starting point. Spatial resolution limits cause the perimeter trace to be somewhat course so that a line straightening algorithm is employed. One result is that the building corner positions become more distinctly defined.

Green, James S.↗

Measuring Thermal Characteristics of Urban Landscapes

The additional heating of the air over the city is the result of the replacement of naturally vegetated surfaces with those composed of asphalt, concrete, rooftops and other man-made materials. The temperatures of these artificial surfaces can be 20 to 40 C higher than vegetated surfaces. Materials such as asphalt store much of the sun's energy and remains hot long after sunset. This produces a dome of elevated air temperatures 5 to 8 C greater over the city, compared to the air temperatures over adjacent rural areas. This effect is called the "urban heat island". Urban landscapes are a complex mixture of vegetated and nonvegetated surfaces. It is difficult to take enough temperature measurements over a large city area to characterize the complexity of urban radiant surface temperature variability. However, the use of remotely sensed thermal data from airborne scanners are ideal for the task. In a study funded by NASA, a series of flights over Huntsville, Alabama were performed in September 1994 and over Atlanta, Georgia in May 1997. Analysis of thermal energy responses for specific or discrete surfaces typical of the urban landscape (e.g., asphalt, building rooftops, vegetation) requires measurements at a very fine spatial scale (i.e., <15 m) to adequately resolve these surfaces and their attendant thermal energy regimes. Additionally, very fine scale spatial resolution thermal infrared data, such as that obtained from aircraft, are very useful for demonstrating to planning officials, policy makers, and the general populace, what the benefits are of the urban forest in both mitigating the urban heat island effect, in making cities more aesthetically pleasing and more habitable environments, and in overall cooling of the community. In this presentation we will examine the techniques of analyzing remotely sensed data for measuring the effect of various urban surfaces on their contribution to the urban heat island effect.

Luvall, Jeffrey C.↗

Cambridge Urban Development - Quantifying Changes in Urban Albedo with NASA Earth Observations to Reduce Urban Heat Island Effect in Cambridge, Massachusetts

The urban heat island (UHI) effect occurs when urban areas have temperatures that are warmer on average than the surrounding suburban and rural regions. Low albedo surfaces traditionally found in urban landscapes, such as dark asphalt and rooftops, absorb solar irradiance and reemit heat, which contributes to the UHI effect. Cambridge,Massachusetts,part of the Boston metropolitan area,expects severe impacts on human health,infrastructure, and local environmental features due to increasing urban heat. The Massachusetts – Boston NASA DEVELOP team partnered with the City of Cambridge Community Development Department and the American Geophysical Union’s Thriving Earth Exchange to inform ongoing planning and heat mitigation efforts. High Resolution Orthoimagery (HRO) and National Agriculture Imagery Program (NAIP) scenes were analyzed in conjunction with ancillary datasets to assess changes in rooftop albedo between 2008 and 2018. Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) data were used to determine nighttime land surface temperature (LST) between 2003 and 2019. Lastly, temperature anomalies were calculated using seasonally averaged nighttime LST values obtained from Aqua MODIS to display ‘hot spots’ for summers between 2004 and 2019. On average, albedo increased by 0.12 across the city, with the majority of positive change in commercial areas. Analysis of mean summer nighttime LST between 2003 and 2019 revealed a non-significant increase in temperature, although temperature anomaly maps demonstrated that Cambridge was warmer on average than rural areas. These results were incorporated in the interactive Cambridge Urban Heat Dashboard, which allows users to explore temporal trends in albedo.

Nicole Ramberg-Pihl↗

Cambridge Urban Development: Quantifying Changes in Urban Albedo with NASA Earth Observations to Reduce Urban Heat Island Effect in Cambridge, Massachusetts

The urban heat island (UHI) effect occurs when urban areas have temperatures that are warmer on average than the surrounding suburban and rural regions. Low albedo surfaces traditionally found in urban landscapes, such as dark asphalt and rooftops, absorb solar irradiance and reemit heat, which contributes to the UHI effect. Cambridge, Massachusetts, part of the Boston metropolitan area, expects severe impacts on human health, infrastructure, and local environmental features due to increasing urban heat. The Massachusetts – Boston NASA DEVELOP team partnered with the City of Cambridge Community Development Department and the American Geophysical Union’s Thriving Earth Exchange to inform ongoing planning and heat mitigation efforts. High Resolution Orthoimagery (HRO) and National Agriculture Imagery Program (NAIP) scenes were analyzed in conjunction with ancillary datasets to assess changes in rooftop albedo between 2008 and 2018. Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) data were used to determine nighttime land surface temperature (LST) between 2003 and 2019. Lastly, temperature anomalies were calculated using seasonally averaged nighttime LST values obtained from Aqua MODIS to display ‘hot spots’ for summers between 2004 and 2019. On average, albedo increased by 0.12 across the city, with the majority of positive change in commercial areas. Analysis of mean summer nighttime LST between 2003 and 2019 revealed a non-significant increase in temperature, although temperature anomaly maps demonstrated that Cambridge was warmer on average than rural areas. These results were incorporated in the interactive Cambridge Urban Heat Dashboard, which allows users to explore temporal trends in albedo.

Nicole Ramberg-Pihl↗

Washington, D.C. & Maryland Energy: Estimating Solar Potential Using NASA POWER Data to Inform Renewable Energy Policy for Washington, D.C.

In line with the Sustainable D.C. 2.0 plan to combat climate change, Washington D.C. aims to decrease its greenhouse gas emissions by 100% by 2050. As solar energy is a clean, renewable energy form, its integration into the region’s power grids lowers energy costs and incentivizes sustainable development. We partnered with the Washington D.C. Department of Energy & Environment (DOEE) to determine how urban areas surrounding D.C. can better be incorporated into decisions regarding renewable energy policy. The team used NASA’s Prediction of Worldwide Energy Resources (POWER) solar data and a Light Detection and Ranging (LiDAR) derived digital surface model, to estimate and visualize rooftop solar potential for Maryland’s Prince George’s and Montgomery counties. POWER provided solar irradiance data adjusted for tilt angle while the digital surface model contributed aspect and slope data. This methodology factored out areas that were unsuitable for solar panel installation while displaying areas that possess a high potential for energy return. The team found the total rooftop solar potential for the study area to be almost 32 million kW, which is equivalent to roughly 660 kW per building. The methodology used to generate the solar potential maps can be applied to other regions of the country seeking to efficiently utilize solar energy. The end users at the DOEE can use our resulting solar potential map and data table to effectively target buildings that have the highest potential to generate solar energy.

Edward Cronin↗

Distributed Solar in Tamil Nadu

With India’s ambitious renewable energy targets and decreasing rooftop solar prices, customer adoption of rooftop solar on Tamil Nadu’s distribution network is set to increase in the coming years. With that comes the challenge of how to assess the impact of these emerging distributed energy resources. In an effort to help with such an assessment, NREL has created a holistic analysis framework for Tamil Nadu Generation and Distribution Company (TANGEDCO). The Emerging technologies Management and Risk evaluation on distribution Grids Evolution (EMeRGE) analysis framework and tool will help TANGEDCO and other distribution companies (DISCOMs) in India analyze new interconnection applications and evaluate the system risk impact over time with new emerging DERs.

Children's Investment Fund Foundation↗

Scaling Building Energy Audits through Machine Learning Methods on Novel Drone Image Data

Building energy audits are time-consuming and labor-intensive. This paper describes a new method using machine learning (ML) techniques on novel data sources (drone images) to improve the identification of building characteristics and retrofit opportunities, and thereby reduce the effort for audits. The new ML method includes: (1) Building footprint extraction using line extraction, polygonization, and polygon-merging, (2) Building envelope extraction using PIX4d modeling software to reconstruct a building 3D model, (3) Visualization tool for viewing images from the 3D model, (4) Window-to-wall ratio (WWR) using state-of-art deep neural network semantic segmentation, (5) Envelope thermal anomaly detection using an unsupervised machine learning clustering algorithm, and (6) Rooftop energy equipment detection based on an object detection algorithm. The testing of this method involved a comparison of additional ML-generated information overlaid on current ‘state-of-practice’ audit and remote assessment baselines using evaluation metrics: labor time and associated cost, marginal benefits of using ML-generated information in workflows for audits and remote assessments, integration potential with existing processes and tools, and replicability/scalability of the method. In two test buildings in California that had comprehensive drawings and meter data available, the ML method effectively generated a building footprint, envelope, rooftop equipment, WWR, and locations of envelope thermal anomalies. Projected target segments of the ML method are sites with minimal drawings and energy data, and underserved sectors such as multistoried housing, disadvantaged communities, and schools for which the ML method can enable identification of building asset characteristics and prioritization of envelope retrofits and decentralized energy equipment retrofits.

Singh, Reshma↗

Close Roof Mounted System Temperature Estimation for Compliance to IEC TS 63126

When photovoltaic modules are installed on rooftops the temperature is dependent on both the geographic location and the mounting configuration. If the mounting structure does not provide sufficient air flow in a hot environment, the 98th percential temperature will exceed 70 degrees C which according to IEC TS 63126 requires higher levels of thermal stability testing. However, a simple there is not a clear way to determe which temperature level is needed for a particular location and system design. In this work we identify a relationship between the gap between the rooftop and a module and propose methods to describe minimum gaps for a given location. Because system designs vary in more ways than just the gap, we show how to determine an effective gap which can be simply applied to generic calculations. Lastly, we show measurements and calculations from several systems to demonstrate how this method could work.

IEC 63126↗

Creating a Universal PV Plug and Socket Standard

Photovoltaic connectors are designed to be quick and easy to install. Current connector qualification standards, such as UL 6703 and IEC 62852, are only intended to evaluate connectors from the same manufacturer and were recently changed to explicitly proscribe the mating of connectors from different manufacturers. Unfortunately, the industry has chosen to design connectors that will commonly connect together with those from other manufacturers. This is done to simplify installation avoiding the situations such as when the connectors on a microinverter, or other module level power electronics, do not match the connectors on the modules in the system. This rampant violation of electrical codes worldwide indicates that there is a strong desire and need to develop a universal connector standard. Here we present the initial approach and philosophy behind the formation of an IEC subgroup under TC82 WG2 looking at this problem. We intend to develop a standard where the materials and geometry of construction are specified to ensure compatibility and the design is intended to be of the highest quality. We expect that this connector will be more costly but especially in rooftop installations where power electronics requires matching components from several manufacturers, that this may still result in a net cost savings. These connectors must be of the highest quality because we wouldn’t want to develop a connector that precluded the manufacturing of a higher quality product, and because these will most commonly be used on rooftop installations where safety is more of a concern. Additionally, because we do not know which brands of connectors will be used together, we cannot simply rely on test results to ensure safety but must create a design that is as inherently safe as possible.

connectors↗

Observations and Lessons Learned in Residential Roofing Integrated Photovoltaics

The data file includes field observations of residential roofing integrated photovoltaics installation that happened between July 2021 and June 2022 in California. There are 21 observations - 2 in the re-roofing category and 19 in the new construction category. The file includes two time and motion forms (Re-Roofing & New Construction) we used to capture the time it takes for each activity in the rooftop solar and electrical installation process. You will see the duration for detailed steps along with activities that are included for total installation time for the paper. There are three parts to the time and motion form - Part 1 has project and crew characteristics, product information, and inspection and permitting data and can be filled before the installation. Part 2 has the actual installation time stamps and related notes. Part 3 has the crew information and can be filled on-site or off-site, but this section is optional. The re-roofing form has pre-solar activities and gutters and vents section in Part 2 of the form, whereas new construction form includes a section for capturing the time it took for rough wiring. The re-roofing form does not include rough wiring but instead includes the final electrical wiring process. These are the key differences in both the forms. Each day/step/installation activity needs to include the crew break time as they happen and there is space available to capture the crew breaks duration. In Table 1 below, the different terms used in the time and motion form are defined and their corresponding unit of measurement stated. We also highlight the optional sections. The data is captured in total mins, total hours, person mins, person hours. You can use this form or make edits to the form to recreate the study or make your own observations. The data herein was reviewed but may not be comprehensive. NREL invites questions and inputs to improve the data, including to: Correct erroneous information Fill in missing/updated information Clarifications on data and variables Updated information may be submitted to Sushmita Jena at sushmita.jena@nlr.gov.

14 SOLAR ENERGY↗

Implementation and validation of optimal start control strategy for air conditioners and heat pumps

Commercial buildings are responsible for approximately 20 % of the total energy consumption and greenhouse gas emissions in the United States. Over 85 % of these buildings lack building automation systems, and many are small (<50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper energy management systems, several operational deficiencies lead to excess energy consumption. Studies have shown that managing the RTUs’ heating and cooling set points, schedules, setbacks, and optimal start can result in a 20 % to 25 % reduction in electricity consumption in small commercial buildings. These buildings typically use fixed schedules to start the RTUs 60 to 120 min before occupancy begins, which results in excess energy consumption. This paper presents research that demonstrates and evaluates the performance of four optimal start methods, which utilize data-based modeling as a key element in facilitating adaptive control in response to time-varying inputs while requiring minimal sensor inputs. The evaluation found energy savings in two commercial buildings equipped with RTUs by periodically alternating four different optimal start models during the cooling and heating season. The resulting energy savings are positive for all models and range from 2 to 5 kWh/day/unit. The units on the east side of the building showed higher savings, while interior units showed greater variability in savings due to the differences in capacities and room sizes. Savings were considerably greater during the heating season compared to the cooling season. The performance of all four models on Mondays was poor; models suggested a shorter optimal start time, which resulted in relatively larger errors. Finally, the future work will look at using a different model for the days after weekends and holidays.

42 ENGINEERING↗

Energy performance evaluation of the ASHRAE Guideline 36 control and reinforcement learning–based control using field measurements

This study evaluates the energy performance of ASHRAE Guideline 36–compliant control (ASHRAE 36 control) and reinforcement learning (RL)–based control through experimental field tests and a simulation study. Three field tests were conducted at Oak Ridge National Laboratory’s commercial building test facility in Oak Ridge, Tennessee: a baseline with a baseline conventional control, a test with ASHRAE 36 control, and a test with RL-based control. The selected ASHRAE 36 controls were trim and respond control, as well as variable air volume (VAV) box control. We compared the measured supply air temperature of the rooftop unit, VAV box supply air temperature, and VAV box supply airflow rate across the three test cases. The field data indicated that ASHRAE 36 controls operated as specified by ASHRAE Guideline 36. Based on these data, ASHRAE 36 control achieved a 45 % reduction in hourly averaged HVAC energy consumption compared with the baseline, and RL-based control achieved a 66 % reduction. These potential annual energy savings were confirmed using a calibrated whole-building energy model. Compared with the baseline, ASHRAE 36 control reduced HVAC energy consumption by 42 %, and RL-based control achieved a 54 % reduction. Furthermore, RL-based control reduced total HVAC energy consumption by 21 % more than ASHRAE 36 control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine learning reduces soft costs for residential solar photovoltaics

Further deployment of rooftop solar photovoltaics (PV) hinges on the reduction of soft (non-hardware) costs—now larger and more resistant to reductions than hardware costs. The largest portion of these soft costs is the expenses solar companies incur to acquire new customers. In this study, we demonstrate the value of a shift from significance-based methodologies to prediction-oriented models to better identify PV adopters and reduce soft costs. We employ machine learning to predict PV adopters and non-adopters, and compare its prediction performance with logistic regression, the dominant significance-based method in technology adoption studies. Our results show that machine learning substantially enhances adoption prediction performance: The true positive rate of predicting adopters increased from 66 to 87%, and the true negative rate of predicting non-adopters increased from 75 to 88%. We attribute the enhanced performance to complex variable interactions and nonlinear effects incorporated by machine learning. With more accurate predictions, machine learning is able to reduce customer acquisition costs by 15% ($0.07/Watt) and identify new market opportunities for solar companies to expand and diversify their customer bases. Our research methods and findings provide broader implications for the adoption of similar clean energy technologies and related policy challenges such as market growth and energy inequality.

14 SOLAR ENERGY↗

Disaggregating Customer-Level Behind-the-Meter PV Generation Using Smart Meter Data and Solar Exemplars

Customer-level rooftop photovoltaic (PV) has been widely integrated into distribution systems. In most cases, PVs are installed behind-the-meter (BTM), and only the net demand is recorded. Therefore, the native demand and PV generation are unknown to utilities. Separating native demand and solar generation from net demand is critical for improving grid-edge observability. In this paper, a novel approach is proposed for disaggregating customer-level BTM PV generation using low-resolution but widely available hourly smart meter data. The proposed approach exploits the strong correlation between monthly nocturnal and diurnal native demands and the high similarity among PV generation profiles. First, a joint probability density function (PDF) of monthly nocturnal and diurnal native demands is constructed for customers without PVs, using Gaussian mixture modeling (GMM). Deviation from the constructed PDF is utilized to probabilistically assess the monthly solar generation of customers with PVs. Then, to identify hourly BTM solar generation for these customers, their estimated monthly solar generation is decomposed into an hourly timescale; to do this, we have proposed a maximum likelihood estimation (MLE)-based technique that utilizes hourly typical solar exemplars. Leveraging the strong monthly native demand correlation and high PV generation similarity enhances our approach's robustness against the volatility of customers’ hourly load and enables highly-accurate disaggregation. Furthermore, the proposed approach has been verified using real native demand and PV generation data.

14 SOLAR ENERGY↗

Chapter 11: Renewable Microgrids as a Foundation of the Future Sustainable Electrical Energy System

Renewable microgrids are an integral part of the future sustainable energy system. This chapter focuses on the role of renewable energy-based microgrids in the electricity system transformation. It is seen as a foundation that complements large-scale generation plants and high-voltage transmission lines by providing additional flexibility and resilience. This flexibility and resilience are crucial for balancing the energy system and ensuring its long-term sustainability, given the changing supply and demand patterns due to rooftop solar photovoltaics (PV), battery storage, electric mobility, and heat pumps. It is also an opportunity for residential and commercial consumers to become active participants in the energy market. Innovation, new technologies and business models will act as the key enabler for this transformation. The regulatory restructuring of the energy market will be crucial for successful integration of prosumers and aggregated energy communities. The chapter presents the vision of a sustainable, decentralized, and digitized energy future including market potential, most innovative case study projects and start-up companies, and the shifts needed in the regulatory landscape.

battery storage↗

Performance Evaluation of Three RTU Energy Efficiency Technologies

This project was part of an effort by CLEAResult and ComEd to evaluate the energy saving potential of emerging technologies in the Chicago area. This project focused on evaluating emerging technologies related to rooftop units (RTUs). An RTU with a single-stage compressor and a constant-speed fan with an induction motor was selected as the baseline for technology comparison. Three retrofit strategies were investigated. The first two involved replacing the single-stage compressor of an RTU by either a two-stage or variable-speed compressor and adding a variable frequency drive (VFD) to the constant speed fan. The use of a multi-/variable-stage compressor improves the part-load efficiency of the compressor which will ultimately result in annual energy savings as well as peak demand shaving in some cases where the design capacity of the RTU is larger than the maximum cooling load of the building space that it is serving. The third technology was the use of a high rotor pole switched reluctance motor (SRM) as a replacement for the constant-speed supply fan. The SRM was applied in single-speed, two-stage and variable-speed compressor RTUs. SRM motors run via reluctance torque. Their stator poles are driven by direct current (DC) power and require an inverter as well as active control when using alternating current (AC) power. This inherent property results in high efficiency over a range of operating conditions. It also exhibits higher efficiency compared to variable frequency drives (VFDs) since its switching frequency is much slower (SCE, 2018).The three technologies investigated are summarized below: 1) Replacing the single-speed compressor with a two-stage compressor and adding a VFD to the supply fan. 2)Replacing the single-speed compressor with a variable-speed compressor and adding a VFD to the supply fan. 3) Replacing the constant-speed induction motor of the supply fan with a high rotor pole SRM. DOE’s building simulation platform EnergyPlus and its graphical user interface OpenStudio were used to evaluate the energy-saving potential of upgrading RTUs, by leveraging experimental data from previous research.