Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiographs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Optical Relays for Imaging Scintillators

Cygnus is a dual beam high-energy radiographic x-ray source. Ten years ago, three large zoom lenses were assembled to collect images from 200 mm x 200 mm square scintillators. The zoom capability allows zooming down to a 60 mm x 60 mm picture from the scintillator. Current radiographic imaging needs now require larger 270 mm x 270 mm square scintillators and the capability to use both 92 mm x 92 mm and 62 mm x 62 mm CCD cameras, and a new lens design to meet these needs. This zoom lens incorporates 11 elements and is designed to be telecentric. It images a scintillator emitting light peaking at 435 nm, so special glass types are required for the lens elements. Much larger elliptical pellicles are needed to deflect the scintillator light out of the x-ray path into the lens. The optical axis of the imaging system must be colinear with the x-ray axis. Two scintillators are positioned in each of two Cygnus x-ray axes, for a total of four scintillators and four lens systems. An optional configuration will be shown, enabling two lens systems imaging opposite sides of a single scintillator, for a total of four lenses and two scintillators. Although this configuration has advantages, it suffers from crosstalk. Care must be taken to analyze the anti-reflection coatings applied to all the elements in the imaging chain, including the CCD array and

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New Design Yields Robust Large-Area Framing Camera

Manuscript to be submitted to Review of Scientific Instruments to determine interest in possible publication. Website: https://aip.scitation.org/rsi/authors/manuscript High-speed imaging is a core diagnostic capability for the Nevada National Security Site (NNSS). Data from experiments that measure the behavior of materials under extreme conditions are essential for the stockpile mission. For example, during subcritical experiments, materials that are shocked and compressed under high-explosive drive change behavior rapidly over timescales measured in millionths or even billionths of a second. Characterizing and understanding this behavior requires radiographic and/or optical imaging to track motion on these timescales. Framing cameras provide a discrete series of images over a short period of time in a manner that mimics a high-speed movie camera, but with individual shutter times that must be extremely short in order to capture freeze-frame images of rapidly evolving phenomena such as high-explosive shock-driven ejecta, dynamic compression of metals, and high-velocity fluid flow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrasonic Testing (UT) Reference Standard for Additive Manufacturing Quality Control

Many additive manufacturing (AM) reference standards for build quality verification concentrate primarily on external features. In contrast, EPRI proposes a pair of AM reference blocks that feature only internal and embedded forms. This report presents, collates, and discusses quantitative nondestructive evaluation (NDE) results from various techniques, including visual testing (VT), radiographic testing (RT), conventional ultrasonic testing (UT), and full matrix capture/total focusing method (FMC/TFM) scanning. The blocks are intended, as part of a larger series of blocks, to evaluate build quality and the relative performance of different NDE techniques in detecting various features. The limits of detectability and the closeness of the as-built shape to the intended form for certain features are quantified, facilitating direct comparison. Upon analysis of the results of this testing, it was found that FMC/TFM was consistently superior in detection, followed by conventional UT, then VT, and lastly RT.

36 MATERIALS SCIENCE↗

How much have adverse occupational health outcomes among construction workers improved over time? Evidence from 25 years of medical screening

Background Construction workers have always had a high risk of occupational illnesses. We used 25 years of data from a medical screening program serving older construction workers to determine how much health outcomes have improved over the past 60 years. Methods We investigated changes in relative risk for chest radiographs consistent with pneumoconiosis, COPD by spirometry, lung cancer mortality, and audiometry-assessed hearing impairment among workers participating in a medical screening program. Results were stratified by decade of first construction employment: before 1960, 1960–1969, 1970–1979, 1980–1989, and after 1990. Poisson and Cox regression analyses assessed relative risk by decade adjusted for age, sex, smoking, and years of construction trade work. Results Subjects were 94% male and, on average, 60 years old with 25 years of construction work. When compared to workers employed before 1960, those first employed after 1990 experienced the following reductions in model-adjusted relative risks: chronic obstructive pulmonary disease, 32%; all pneumoconiosis, 68%; parenchymal abnormalities, 35%; pleural abnormalities, 71%; hearing impairment, 20%; and lung cancer mortality, 48%. Risks started to decline in the 1960s with greatest reductions among workers first employed after 1970. Conclusions This study demonstrates the positive impact that adoption of occupational health protections have had over the past 60 years. The greatest risk reductions were observed for outcomes with strong regulatory and legal incentives to reduce exposures and associated risks, such as those associated with inhalation hazards (asbestos and silica), while lowest improvement was for hearing impairment, for which little regulatory enforcement and few prevention incentives have been adopted.

60 APPLIED LIFE SCIENCES↗

Artificial intelligence to unlock real-world evidence in clinical oncology: A primer on recent advances

Purpose: Real world evidence is crucial to understanding the diffusion of new oncologic therapies, monitoring cancer outcomes, and detecting unexpected toxicities. In practice, real world evidence is challenging to collect rapidly and comprehensively, often requiring expensive and time-consuming manual case-finding and annotation of clinical text. In this Review, we summarise recent developments in the use of artificial intelligence to collect and analyze real world evidence in oncology. Methods: We performed a narrative review of the major current trends and recent literature in artificial intelligence applications in oncology. Results: Artificial intelligence (AI) approaches are increasingly used to efficiently phenotype patients and tumors at large scale. These tools also may provide novel biological insights and improve risk prediction through multimodal integration of radiographic, pathological, and genomic datasets. Custom language processing pipelines and large language models hold great promise for clinical prediction and phenotyping. Conclusions: Despite rapid advances, continued progress in computation, generalizability, interpretability, and reliability as well as prospective validation are needed to integrate AI approaches into routine clinical care and real-time monitoring of novel therapies.

60 APPLIED LIFE SCIENCES↗

Gamma-Ray and Cosmic Ray Muon Modalities for Cargo Inspection

Screening and inspection of cargo containers are two essential methods to nondestructively examine the contents of shipment. These methods enable the detection of illicit transportation of unauthorized materials such as nuclear and radioactive materials, explosives, drugs, and so on, typically at borders or secure facilities. Although high-energy X-ray transmission is a standard system and is widely used for cargo inspection, the inherent challenges of high false-positive rates and high attenuation factors necessitate the development of complementary techniques that can increase the detection efficiency and accuracy in large and dense materials. Gamma-rays, which possess higher penetration characteristics because of their high energy, offer an alternative nonintrusive modality for cargo scanning. They represent a promising inspection method when compared to X-rays for three reasons: (1) improved ability to detect nuclear and radioactive materials, (2) higher inspection throughput rates, and (3) lower false-positive rates. Currently, there are two main gamma-ray inspection techniques, active and passive interrogation. Active interrogation can be further grouped into (1) gamma-ray transmission imaging and (2) neutron-induced gamma-ray emission detection. Gamma-ray transmission imaging utilizes differences in material densities for mapping the shipment contents and detecting anomalies. It is analogous to the X-ray transmission method; however, the high-energy photons make it more difficult to shield against, which enables more efficient performance in large and dense material inspection. Neutron-induced gamma-ray emission inspection is designed for the detection of nuclear and radioactive material because those materials emit characteristic gamma-rays when they are activated by neutron absorption. On the other hand, passive interrogation techniques rely on high-efficiency detectors to detect radiation emitted from hidden special nuclear or other radioactive materials. Similar to passive interrogation, cosmic ray muon monitoring and imaging are relatively new techniques that do not require external radioactive sources. These techniques have received attention as a potential next-generation radiographic probe to identify illicit transportation of nuclear and radioactive materials in cargo containers. Cosmic ray muons have unique features, (1) much higher energies than X-rays or gamma-rays (on the order of 10−1—104 GeV), (2) enhanced penetration capability, and (3) natural occurrence, thereby eliminating the need for induced radiation sources. These features enable cosmic ray muons to be utilized for detection of special nuclear materials in high-background-noise environments. By analyzing incoming and outgoing muon trajectories, scattering angles, and energies, it has been shown that it would be possible to locate hidden and well-shielded materials in cargo containers via three-dimensional muon tomography images or signal analysis. Gamma-rays, cosmic ray muons, and other nonintrusive cargo inspection modalities are complementary to each other, allowing them to address various cargo inspection conditions (i.e., scanning time, cost, radiation exposure level, and types of target materials). This chapter presents a detailed review of the theoretical fundamentals and technical principles behind the current gamma-ray and cosmic ray muon modalities for cargo inspection. Additionally, critical assessments and suggestions for the future directions to advance the use of gamma and muon modalities are discussed.

Bae, Junghyun↗

Out-of-Distribution Detection and Radiological Data Monitoring Using Statistical Process Control

Abstract Machine learning (ML) models often fail with data that deviates from their training distribution. This is a significant concern for ML-enabled devices as data drift may lead to unexpected performance. This work introduces a new framework for out of distribution (OOD) detection and data drift monitoring that combines ML and geometric methods with statistical process control (SPC). We investigated different design choices, including methods for extracting feature representations and drift quantification for OOD detection in individual images and as an approach for input data monitoring. We evaluated the framework for both identifying OOD images and demonstrating the ability to detect shifts in data streams over time. We demonstrated a proof-of-concept via the following tasks: 1) differentiating axial vs. non-axial CT images, 2) differentiating CXR vs. other radiographic imaging modalities, and 3) differentiating adult CXR vs. pediatric CXR. For the identification of individual OOD images, our framework achieved high sensitivity in detecting OOD inputs: 0.980 in CT, 0.984 in CXR, and 0.854 in pediatric CXR. Our framework is also adept at monitoring data streams and identifying the time a drift occurred. In our simulations tracking drift over time, it effectively detected a shift from CXR to non-CXR instantly, a transition from axial to non-axial CT within few days, and a drift from adult to pediatric CXRs within a day—all while maintaining a low false positive rate. Through additional experiments, we demonstrate the framework is modality-agnostic and independent from the underlying model structure, making it highly customizable for specific applications and broadly applicable across different imaging modalities and deployed ML models.

Zamzmi, Ghada↗

Design and validation of a gamma-ray scanning system for measuring irradiated nuclear fuel

We report a prototype gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. This paper documents the design process, modeling and the laboratory characterization performed to validate the system. The modeling of the system was done using the Monte Carlo N-Particle code with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector. The characterization included measurements of calibrated radiation sources in different geometries, and calculations for absolute efficiency and dead time. Benchmark measurements were performed scanning an irradiated fuel rodlet containing ten pellets of 4.9% enriched UO2 in zirconium alloy. These results were compared to simulated spectra to further help characterize the detector model. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel; comparison of the results from this prototype system's assay of the irradiated fuel rodlet are in agreement with previously estimated results.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Feasibility of volumetric expansion of molten chlorides by conventional pushrod dilatometry

Abstract This study is a short communication on progress made in the adaptation of conventional push-rod dilatometry for the measurement of volumetric expansion of liquid salts up to 1300 K. A new crucible design is offered as a practical solution for measurement of liquid salts by this method. Proof-of-concept measurements of the volumetric expansion of sodium chloride (NaCl) are compared to the available data in literature. Measurement of the coefficient of thermal expansion (CTE) of solid NaCl compared favorably to the available data in literature, confirming both magnitude and trend. The average CTE of NaCl (solid) was $$\overline{\alpha }_{{{\text{NaCl}}\;{\text{Solid}}}} = 5.63 \cdot 10^{ - 5} {\raise0.7ex\hbox{$1$} \!\mathord{\left/ {\vphantom {1 K}}\right.\kern-\nulldelimiterspace} \!\lower0.7ex\hbox{$K$}}$$ α ¯ NaCl Solid = 5.63 · 10 - 5 1 K . The volumetric expansion of liquid NaCl was measured as $$\beta_{{{\text{NaCl}}\;{\text{Liquid}}}} \approx 3.96 \cdot 10^{ - 5} 1/K$$ β NaCl Liquid ≈ 3.96 · 10 - 5 1 / K and is essentially constant from the melt point to 1300 K. The volumetric expansion produced by this method is in reasonable agreement with the available published data and previous measurements made by the authors by neutron radiographic technique.

Parker, S. S. (ORCID:000000018597440X)↗

Machine-Learning-based Algorithms for Automated Image Segmentation Techniques of Transmission X-ray Microscopy (TXM)

Four state-of-the-art Deep Learning-based Convolutional Neural Networks (DCNN) were applied to automate the semantic segmentation of a 3D Transmission x-ray Microscopy (TXM) nanotomography image data. The standard U-Net architecture as baseline along with UNet++, PSPNet, and DeepLab v3+ networks were trained to segment the microstructural features of an AA7075 micropillar. A workflow was established to evaluate and compare the DCNN prediction dataset with the manually segmented features using the Intersection of Union (IoU) scores, time of training, confusion matrix, and visual assessment. Comparing all model segmentation accuracy metrics, it was found that using pre-trained models as a backbone along with appropriate training encoder-decoder architecture of the Unet++ can robustly handle large volumes of x-ray radiographic images in a reasonable amount of time. This opens a new window for handling accurate and efficient image segmentation of in situ time-dependent 4D x-ray microscopy experimental datasets.

36 MATERIALS SCIENCE↗

Mass Spectrometry-Based Approaches for Clinical Biomarker Discovery in Traumatic Brain Injury

Purpose of Review: Precision treatments to address the multifaceted pathophysiology of traumatic brain injury (TBI) are desperately needed, which has led to the intense study of fluid-based protein biomarkers in TBI. Mass Spectrometry (MS) is increasingly being applied to biomarker discovery and quantification in neurological disease to explore the proteome, allowing for more flexibility in biomarker discovery than commonly encountered antibody-based assays. In this narrative review, we will provide specific examples of how MS technology has advanced translational research in traumatic brain injury (TBI) focusing on clinical studies, and looking ahead to promising emerging applications of MS to the field of Neurocritical Care. Recent Findings: Proteomic biomarker discovery using MS technology in human subjects has included the full range of injury severity in TBI, though critically ill patients can offer more options to biofluids given the need for invasive monitoring. Blood, urine, cerebrospinal fluid, brain specimens, and cerebral extracellular fluid have all been sources for analysis. Emerging evidence suggests there are distinct proteomic profiles in radiographic TBI subtypes, and that biomarkers may be used to distinguish patients sustaining TBI from healthy controls. Metabolomics may offer a window into the perturbations of ongoing cerebral insults in critically ill patients after severe TBI. Summary: Emerging MS technologies may offer biomarker discovery and validation opportunities not afforded by conventional means due to its ability to handle the complexities associated with the proteome. In conclusion, while MS techniques are relatively early in development in the neurosciences space, the potential applications to TBI and neurocritical care are likely to accelerate in the coming decade.

59 BASIC BIOLOGICAL SCIENCES↗

Quantitative Comparisons of Image Quality for Flash X-Ray Detectors

Due to X-rays’ ability to penetrate materials, flash X-ray radiography can be used for high-speed measurements where direct optical access is not possible. Choice of detector has a pronounced impact on resulting image quality. Four different detector systems were evaluated with a 450kVp flash source to quantitatively compare image quality metrics. The scintillating digital detector had less image noise than the three different storage phosphor computed radiography detectors across all transmission levels, but lacked the spatial resolution of the computed radiography detectors. For the screens tested here, the HPX-DR digital system had the highest signal to noise ratio of 68.24 and contrast to noise ratio of 35.53, but had the lowest spatial resolution, resolving 2.5 line pairs per millimeter at 1.78% contrast. At a value of 37.59, the Flex GP imaging plate had a signal to noise value above its storage phosphor counterparts under a 450kVp flash source. For radiographic setups typically used for dynamic experiments, the Flex XL Blue and Flex HR detectors had signal to noise ratios of 18.44 and 26.56 respectively. The highest resolved spatial frequencies of the Flex GP, Flex XL Blue, and Flex HR with the flash source are 3.85, 5.00, and 3.85 line pairs per millimeter, respectively. In conclusion, the Flex GP detector had the best combination of signal to noise ratio, contrast to noise ratio, and spatial resolution under a flash source.

computed radiography↗

An Analysis of Input Parameters for Film-Based Flash X-Ray Radiography

Flash X-ray radiography (flash) is a commonly used diagnostic technique in dynamic experiments. An analysis of the effects of input parameters on resulting metrics of image quality can aid the experimentalist in configuring the X-ray input parameters to produce the highest quality radiograph for a given experiment. Here, a flash X-ray test bed with HS800 film and a LANEX Medium F intensifier screen was used with an L3 450 kVp pulser and Scandiflash X-ray tube for this study. Input parameters including charge voltage, source filtering, and film-pack assembly were investigated for their impact on contrast-to-noise ratio (CNR), contrast, and contrast transfer function (CTF). Using VIDAR’s NDT Pro industrial film digitizer, scanner parameters such as optical density range, pixel spacing, scan mode, and digital bit-depth were also examined for their impact on image quality metrics. The highest CNR values were found with two LANEX intensifiers and no filtering. Charge voltage had no direct impact on CNR values. LANEX screen count and filtering resulted both in direct effects on CNR and interaction effects with each other and CNR value. Uncertainty bounds for CNR comparisons and repeatability of CTF evaluations are also discussed. Finally, the film results are compared with a previous study using other detector types, specifically Carestream INDUSTREX Flex GP, Flex HR, Flex XL Blue, and HPX-DR 3543.

dynamic radiography↗

Further Development of the Tamped Richtmyer-Meshkov Instability Method and Application to Molybdenum Dynamic Strength Calibration and Tabulation

The high pressure and high strain rate dynamic strength of Mo is experimentally and computationally investigated in the 3–20 GPa stress, 50–600 C temperature, and 10 5 –10 6 /s strain rate regimes using a modified tamped Richtmyer-Meshkov instability (RMI) method. Modifications to the tamped RMI method include a method to determine loading states during strain, a new strength calibration function based on interface shape, and a robust uncertainty quantification method. These modifications improve fidelity of the tamped RMI method, allowing evaluation of the compensating effects of pressure hardening, strain rate hardening, strain hardening, and thermal softening. The new calibration function based on interface shape is not limited to sinusoidal corrugations and could be applied to additional interface shapes. Plate impact experiments are performed at Argonne National Laboratory’s Advanced Photon Source’s Dynamic Compression Sector operated by Washington State University (DCS), driving a planar shock front through a corrugated Mo-D 2 O or Mo-C 8 F 18 interface, forcing the corrugation to significantly deform. The extent of interfacial deformation, RMI growth, is experimentally observed using X-ray phase contrast imaging at the DCS. RMI jet lengths and jet shapes are extracted from the experimental radiographs, then used to calibrate numerical simulations performed with the Sandia National Laboratories (SNL) hydrocode CTH. Mo yield strength, Y, as a function of shock pressure, P, strain rate, $\dot{\varepsilon }$, accumulated strain, ϵ, relative volumetric compression, RD , and temperature, T , is determined for each impact experiment and presented. The calibrated Mo yield strength values range 1.2–1.8 GPa, with strength generally decreasing as the impact stress increases. This trend is likely caused by thermal softening or strain localization. The tabular yield strength versus loading condition data presented in this paper can be used to fit complex strength models.

Voorhees, T. J. [Sandia National Lab. (SNL-CA), Li↗

Direct observation of C 3 S particle dissolution using fast nano X-ray computed tomography

Tricalcium silicate (C 3 S) occupies 50 % to 70 % of ordinary portland cement (OPC) by mass and it is an important component affecting the hydration of OPC [1], [2], [3], [4], [5], [6], [7]. Generally, the hydration of C 3 S is described by two processes: the dissolution of C 3 S particles and the precipitation of hydration products. While it is understood that the dissolution rates of C 3 S vary with time, more precise measurements are needed to understand this process. Many mechanisms have been proposed to explain the time-evolving dissolution rates of C 3 S [2]. The metastable barrier hypothesis suggests that a thin metastable layer of hydrates forms around the C 3 S particle surface and prohibits the access of grains to the aqueous solution [8], [9], [10], [11], [12]. The slow dissolution step hypothesis suggests that the increased ion concentration from the initial reaction delays the C 3 S dissolution [2], [13], [14], [15], [16], [17]. More recent publications suggest that C 3 S may react differently depending on the existence of crystallographic defects [18], [19], [20]. Etch pits are thought to open on the particle surface during the initial reaction and this contributes to the C 3 S dissolution [21], [22]. As hydrates precipitate and cover these highly reactive surfaces, hydration slows down and the induction period starts [18], [23], [24], [25], [26]. Many experiments have been conducted to test the aforementioned mechanisms. Some hydration studies utilize bulk measurements, such as isothermal calorimetry [27], [28], [29], pore solution analysis [30], quasi-elastic neutron scattering [31], and nuclear magnetic resonance spectroscopy [32], [33]. One limitation of these measurements is that they do not provide direct and detailed information on the individual C 3 S particles. Some other studies utilize imaging techniques, such as scanning electron microscopy (SEM) [34], [35], [36] and transmission electron microscopy (TEM) [37]. However, SEM/TEM cannot track the evolution of individual particles throughout hydration [34], [35], [38], [39], [40] and they do not give insights into the microstructure of materials before hydration [34], [35], [39]. This makes it challenging to draw strong conclusions from only SEM or TEM observations. Synchrotron X-ray tomography techniques have been used more broadly in recent years to study cement hydration. They are not only non-destructive but also able to image a sample in full 3D with resolutions that can reach from micron to nanoscale. Nano computed tomography (nCT) is one technique that has been applied to study cement hydration at the nanoscale [26], [41]. A typical nCT can reach a pixel size from 15 to 65 nm, providing enough detail for observing features <1 μm. However, nCT often takes >0.5 h to finish one scan. This makes the application of this technique on continuous scans for in-situ observations challenging. Fast X-ray computerized tomography (fCT) is another technique that has shown success in studying the time-evolving cement microstructures [20], [42], [43], [44], [45], [46], [47], [48], [49]. Due to the high flux of the X-ray beam from the synchrotron ring, fCT allows a scan to be captured within 1 min at a pixel size of 1 μm. This allows a paste sample to be continuously scanned during the hydration process. However, the micron-sized resolutions limit does not provide detailed insights for particles <5 μm [20], [49]. Fortunately, the combination of nCT and fCT has allowed the development of fast nano X-ray computed tomography (fnCT). fnCT can capture a 3D data set in <2 min at a pixel size of 50 nm. This makes this procedure an exciting method to evaluate hydrating pastes. fnCT collects multiple X-ray radiographs at various rotation angles and generates a 3D model of the scanned sample, which is also referred to as a 3D tomography [50], [51]. In one tomography, the X-ray absorptions of different components (e.g., C 3 S and hydrates) differ as functions of density and chemistry [52], [53]. These X-ray absorption contrasts can be used to extract detailed information about the 3D microstructure [26], [54], [55]. In this paper, fnCT is used to collect time-lapse tomographs of hydrating C 3 S paste from 18 min after mixing to 7 h of hydration. The bulk measurements of anhydrous C 3 S, as well as the microstructural changes of individual C 3 S particles, are directly observed, quantified, and discussed. The dissolution behavior of C 3 S particles at various size scales is systematically analyzed and compared. This work aims to find the relationship between the size of C 3 S particle sizes and their dissolution rates. This provides significant insights into the early-age hydration of C 3 S on length and time scales not previously possible. Because of the magnitude of the data and the substantial amount of observations, this work will solely focus on the change in the anhydrous particles. Changes in the hydration products will be reported in future work.

42 ENGINEERING↗

Real-time damage characterization for GFRCs using high-speed synchrotron X-ray phase contrast imaging

Here, we report the application of high-speed synchrotron X-ray phase contrast imaging (PCI) in real-time damage characterization for glass fiber reinforced composites (GFRCs) subjected to dynamic loading. Dynamic single-edge notched bending (DSENB) experiments on pre-notched S-2 GFRCs were performed on a modified Kolsky compression bar. During loading, the synchrotron X-ray beam penetrated through the composite specimen from the side to detect damage evolution inside the material. Entire dynamic events were recorded by a high-speed camera as image sequences.0° and 90° unidirectional and cross-ply composites were investigated. An optical imaging technique was also employed to capture similar dynamic events in comparison with the radiographic imaging. It is demonstrated that high-speed X-ray PCI had sufficient phase contrast to characterize a crack initiation at a 20-μm spatial resolution within 920 ns and track the crack geometry during propagation, thereby providing reliable data to quantify the dynamic damage resistance of GFRCs. Furthermore, being capable of recognizing microscopic damage-related features at a sub-10-μm resolution, high-speed X-ray PCI provided fundamental material failure mechanisms to reveal the essential of macroscale structural failure of composites. It can also track the damage evolution inside and between individual plies of laminated composites. However, current high-speed X-ray PCI technique only supports in-situ observation and the high timing and spatial resolutions are limited within a field of view of ~2.5 mm in square, preventing its application in the three-dimensional and larger-area damage detection for GFRC structures.

42 ENGINEERING↗

Enabling end-to-end secure federated learning in biomedical research on heterogeneous computing environments with APPFLx

Facilitating large-scale, cross-institutional collaboration in biomedical machine learning (ML) projects requires a trustworthy and resilient federated learning (FL) environment to ensure that sensitive information such as protected health information is kept confidential. Specifically designed for this purpose, this work introduces APPFLx - a low-code, easy-to-use FL framework that enables easy setup, configuration, and running of FL experiments. APPFLx removes administrative boundaries of research organizations and healthcare systems while providing secure end-to-end communication, privacy-preserving functionality, and identity management. Furthermore, it is completely agnostic to the underlying computational infrastructure of participating clients, allowing an instantaneous deployment of this framework into existing computing infrastructures. Experimentally, the utility of APPFLx is demonstrated in two case studies: (1) predicting participant age from electrocardiogram (ECG) waveforms, and (2) detecting COVID-19 disease from chest radiographs. Here, ML models were securely trained across heterogeneous computing resources, including a combination of on-premise high-performance computing and cloud computing facilities. By securely unlocking data from multiple sources for training without directly sharing it, these FL models enhance generalizability and performance compared to centralized training models while ensuring data remains protected. In conclusion, APPFLx demonstrated itself as an easy-to-use framework for accelerating biomedical studies across organizations and healthcare systems on large datasets while maintaining the protection of private medical data.

Biomedical Research↗

Progress toward NIF opacity measurements

The opacities of iron and other mid-Z elements help to regulate the transport of energy in the sun. Recent experiments on the Sandia National Laboratories Z machine have shown large discrepancies between the measured and calculated opacities of iron at certain solar conditions. To replicate these opacity measurements a platform is being developed on the National Ignition Facility to measure the opacities of iron and other elements at the same conditions as in the Z experiments. The NIF platform consists of a hohlraum to heat the opacity sample to the desired conditions, a separate backlighter to radiograph the sample, and a spectrometer to give the spectrally resolved opacity. Not only must the opacity be measured but the temperature and density of the sample must also be accurately determined. This platform has now produced its first iron transmission measurements. Overall, these measurements will be presented along with plans for future measurements and details on how the measurements will be improved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗