Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiation detection systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Calculating beam extinction in a pulsed proton beam using FPGA-based peak detection

The Mu2e experiment at Fermilab imposes stringent requirements on the elimination of out-of-time beam in its pulsed proton beam, a requirement known as “extinction”. Utilizing a new μTCA-based FPGA data acquisition system, we recorded live particle data from scattered particles incident on an array of quartz Cherenkov radiators and photomultiplier tubes to measure the extinction in the inter-pulse gaps in the pulsed proton beam. Minuscule errors in the derived signal period can make a measurement of the extinction impossible, so after taking a Fourier transform, further optimizations on the period were done based on the assumption that the signal period is stable over the full time of the beam spill while it is being resonantly extracted. After these optimizations, the beam extinction was shown to be on the level of 10^3.

Hensley, Ryan [UC, Davis]↗

A Preliminary Investigation for the Use of Digital Gamma-Gamma Coincidence Spectrometry to Determine 239 Pu

Gamma-ray spectrometry is one of the most effective ways to determine the activity of 239 Pu, depending on activity levels. However, often high backgrounds in complex spectra with low amounts of 239 Pu can increase detection limits. The effectiveness of the use of gamma-gamma spectrometry in the characterization of 239 Pu was studied for the first time. Using the XIA Pixie-16 digital pulse processor, the gamma-gamma system was studied to establish unshielded background radiation, source to detector distances, Poisson statistics and gating of several gamma-rays from 239 Pu. The results clearly show that the distance between gamma ray spectrometers has a much bigger effort in counting statistics for the gamma-gamma coincidence detectors than a single detector. In addition, measurements demonstrated the background radiation to be virtually negligible, meaning gammagamma spectroscopy can still be very effective without requiring the usual lead shielding. Other measurements were taken to assure Poisson statistics were attained in the digital system. Preliminary measurements revealed 3 orders of magnitude background reduction for the measurement of 239 Pu using gated gamma-rays.

61 RADIATION PROTECTION AND DOSIMETRY↗

A quantum trajectory picture of single photon absorption and energy transport in photosystem II

Here, we use quantum trajectory theory to study the dynamics of the first step in photosynthesis for a single photon interacting with photosystem II (PSII). By considering individual trajectories we are able to look beyond the ensemble average dynamics to compute the PSII system evolution conditioned upon individual photon counting measurements. Measurements of the transmitted photon beam strongly affects the system state, since detection of an outgoing photon confirms that the PSII must be in the electronic ground state, while a null measurement implies it is in an excited electronic state. We show that under ideal conditions, observing the null result transforms a state with a low excited state population to a state with nearly all population contained in the excited states. We study the PSII dynamics conditioned on such photon counting for both a pure excitonic model of PSII and a more realistic model with exciton-phonon coupling to a dissipative phononic environment. In the absence of such coupling, we show that the measured fluorescence rates show oscillations constituting a photon-counting witness of excitonic coherence. Excitonic coupling to the phonon environment has a strong effect on the observed rates of fluorescence, damping the oscillations. Addition of non-radiative decay and incoherent transitions to radical pair states in the reaction center to the phononic model allows extraction of a quantum efficiency of 92.5% from the long-time evolution, consistent with bulk experimental measurements.

Coherent states↗

Integrating Metal-Hydride and Gas-Detector for Tritium Gas Detection

Detection of trace amounts of environmental tritium is a challenging problem, driving the need for field-deployable systems that offer high sensitivity, selectivity, and minimal false positives. We present a technique for high-sensitivity, high-selectivity tritium measurement, which integrates metal-hydride and gas-detector concepts into a compact field-deployable tritium sensor. A hydrogen-storage metal embedded in a gas proportional counter selectively absorbs protium (1H)/tritium (3H), which are subsequently released into the counter volume with a reduced radiation background. Ionizations induced by 3H beta particles are then measured in proportional counting mode, achieving high detection efficiency. Preliminary studies conducted with palladium (Pd) thin films coated on stainless-steel substrates demonstrated 3H absorption and metal-tritide formation, followed by 3H desorption upon heating the metal-tritide. These processes were confirmed using activity concentrations measured by a commercial tritium monitor and pulse height spectra acquired from a custom-built detector.

Gas-proportional counter↗

ECEI characterization of pedestal fluctuations in quiescent H-mode plasmas in DIII-D

Here, electron cyclotron emission imaging (ECEI) is employed to characterize the magneto hydraulics dynamics (MHD) fluctuations at the quiescent H-mode pedestals in DIII-D. Pedestal MHD fluctuations cause ECE radiation temperature fluctuations $\delta {T_{e{\text{,rad}}}}$ in both the pedestal and scrape-off-layer (SOL). A synthetic ECE platform is utilized for detailed interpretation of the ECEI signals in the SOL and pedestal regions. It is observed that the ECE radiation $\delta {T_{e{\text{,rad}}}}$, which is located in the SOL region according to the cold and optically thick plasma resonance assumption, is extremely sensitive to MHD radial displacements near the separatrix, exhibiting radiation inversion to $\delta {T_{e{\text{,rad}}}}$ at the pedestal. Here, the radiation inversion refers to the opposite phase between the radiation fluctuation at the pedestal and the radiation fluctuation at the SOL. Consequently, the quasi-coherent MHD (QCM), which displays a radiation inversion, is found to be consistent with an MHD radial structure that has a strong displacement near the separatrix. In contrast, the edge harmonic oscillation (EHO), which displays weak or no inversion, is found to be consistent with an MHD radial displacement structure peaking at the pedestal top. The ECEI data, interpreted with synthetic ECE, are in qualitative agreement with beam emission spectroscopy measurements on DIII-D for the relative radial extent and localization of the EHO and QCM. The high sensitivity of ECE radiation to separatrix displacements can be used to detect turbulence or MHD fluctuations near the separatrix, which may affect the transport across the separatrix and the wetted area in the divertor. The $\delta {T_{e{\text{,rad}}}}$ inversion measured with an ECE or ECEI system potentially provides important information on the magnetic field $\left| {{B_{{\text{sep}}}}} \right|$ at the separatrix, which helps constrain the pedestal equilibrium reconstruction and achieve an unambiguous mapping of the ECE/ECEI system with respect to the separatrix.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Encryption of Signal Pulses to Replace Tamper-indicating Conduit

In order to verify signal integrity and point of origin for TTL pulse data used in IAEA systems, and to avoid the need for expensive tamper-indicating conduit or electronic techniques, we propose the development of a signal pulse signing and encryption in-line device. In measurement applications in which the data acquisition electronics is separate from the enclosed, sealed detector, tamper-indicating techniques are required to protect raw TTL pulse streams between the detector and the data acquisition module, i.e UMSR. The goal of this proposed project is to design a rad-tolerant transmitter that would mount inside the sealed detector system and a receiver in the sealed electronics cabinet with the data acquisition instrument. This transmitter/receiver pair would digitally sign and encrypt the pulse stream data at the detector then transmit the data to the sealed cabinet where the receiver would decrypt the data and reproduce the original pulse stream. Existing tamper indicating techniques, such as LiveWire’s spread spectrum time domain reflectometry rely on detecting physical changes to the wiring system and can be blind to fast coupling of micro-second wide pulses. Digital signing and encryption techniques such as the Sandia Laboratories Enhanced Data Authentication System (EDAS) are capable of encrypting communications data, i.e. RS-232, but are not capable reproducing a critical time correlated data streams. Recent NA-241 Safeguards Technology supported developments have reduced the need for special conduit to transmit data via Ethernet by incorporating the IAEA RAINSTORM data encryption and authentication protocol, a tamper indicator is still required to protect raw pulse data from detectors to the acquisition electronics. Encrypting pulse data is especially complicated for radiation detection instruments due to the time correlation data analysis that is performed on this data stream. Any corruption in the timing information will produce errors in measurement values.

97 MATHEMATICS AND COMPUTING↗

Terrestrial Gamma‐Ray Flash Following Intense Negative Return Stroke Observed With BIMAP‐3D

We report ground-based observations of a terrestrial gamma-ray flash (TGF) associated with a strong negative cloud-to-ground lightning strike (-CG) which occurred near Los Alamos National Laboratory (LANL) in New Mexico, USA. Gamma photons were detected by the Terrestrial High-energy Observations of Radiation (THOR) instrument, developed at the University of California, Santa Cruz, which has been hosted at LANL since 2022. Simultaneous measurements were also made with the 3-Dimensional Broadband Interferometric Mapping and Polarization (BIMAP-3D) system, which includes 3D lightning mapping, two fast antennas, and an additional plastic scintillator. Additional field change waveforms were obtained from the Earth Networks Total Lightning Network (ENTLN). The lightning initiated about 1 km above the ground, leading to a powerful -CG with an ENTLN peak current of −237 kA and bipolar field change matching the recently described “energetic compact stroke” (ECS) shape. The TGF was then observed ∼35 µs after the start of the return stroke. We also observe an electric field pulse likely produced by the TGF either in isolation or by coupling to the lightning channel. Based on modeling of the radiated electric field and photon propagation through the atmosphere we infer that the TGF source was on the order of 1⁢0 17 photons. This TGF and associated lightning are extremely similar to some recently reported ECS TGFs in coastal Japan in winter, but we report the first observation of this phenomenon outside of Japan in a different climate, terrain, and season.

58 GEOSCIENCES↗

Impact of Spontaneous Fission Neutron Emission Energy on Neutron Detector Response

A parametric study was simulated in MCNP to investigate the impact of spontaneous fission neutron energy on neutron detector response. A total of 880 configurations were simulated by varying 3 He pressure and polyethylene reflector thickness for 8 different isotopes. Results showed that deviations between the simulated isotopes become more prevalent at higher energies with 238 U showing the greatest deviation. It was also observed that configurations comparable to most detection setups, 10 atm and 6 - 8 cm polyethylene, were closer to the upper bound of deviations from a 252 Cf. 240 Pu, a common spontaneous fission source of interest, ranged from 2% - 3% within this space. This suggests that further investigation is required to determine exact correction factors when calibrating neutron detectors with a 252 Cf. Although demonstrated here for a 4π-detection system, future plans include simulating a more detailed model of the MC-15 detection setup to determine exact correction factors for future experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterizing the γ-Ray Emission from Low-luminosity AGN

A majority of the active galactic nuclei (AGN) in the local Universe are classified as low-luminosity AGN (LLAGN), having bolometric luminosities ≲10 42 erg s −1 . Although high-energy γ-ray emission is predicted from both the jets and disks of LLAGN, to date only four have been detected by the Fermi Large Area Telescope (Fermi-LAT). In this work, we therefore conduct a comprehensive study of all the LLAGN from the Palomar spectroscopic survey of bright, northern galaxies, including both subthreshold and detected γ-ray sources, using 14.4 yr of LAT data. Our analysis results in a new detection of one LLAGN, as well as a detection of the subthreshold population using a stacking technique. We find that the signal from the subthreshold sample is consistent with being dominated by star formation activity, although a contribution from compact jets or a mixed contribution from jetted and nonjetted systems is also feasible. On the other hand, the individually detected LLAGN are likely dominated by jet emission. We perform detailed spectral modeling for a subset of these sources and find that the γ-ray signal can be explained by synchrotron self-Compton radiation if the inner jet emission region is weakly magnetized, with its total energy density being strongly particle dominated and only slowly moving. With this work we also publicly release our Python-based stacking library for analyzing subthreshold source populations with the LAT based on a proven technique used in numerous studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Methods and systems for determining soiling on photovoltaic devices

An aspect of the present disclosure relates to radiating light on to a front surface of a glass pane comprising a first surface and a second surface defining a thickness between the first surface and the second surface, wherein the first surface is substantially parallel to the second surface; detecting a transmittance of the light through the glass pane; comparing the transmittance through the glass pane to a reference transmittance value corresponding to a clean reference glass pane; and determining, using the transmittance and the reference transmittance, a soiling metric of a photovoltaic module.

14 SOLAR ENERGY↗

Toward an integrated multi-gigahertz ionizing particle diagnostic

Needs arising at both current and future accelerator facilities call for the development of radiation-hardened position-sensing diagnostics that can operate with multi-GHz repetition rates. Such instruments are likely to also have applications in the diagnosis of rapid plasma behavior. Here, building on the recent work of our Advanced Accelerator Diagnostics Collaboration, we are exploring the development of integrated multi-GHz ionizing particle detection systems based on chemical-vapor deposition diamond sensors, with the initial goal of producing a quadrant detector that can determine the intensity and centroid position of a particle beam at a repetition rate between 5 and 10 GHz. Results from our initial high-speed characterization work are presented, including those from a single-channel sensor with a GHz response. Approaches to achieving multi-GHz (5–10 GHz) rate capability, including the design of a dedicated Application Specific Integrated Circuit and the use of 3D RF-solver computer aided design software, are presented and discussed in more detail. 3D RF simulations suggest clean pulses of duration less than 250 ps (FWHM less than 125 ps) can be achieved with the approaches developed by this work.

43 PARTICLE ACCELERATORS↗

Improved field-portable system to measure Cs-137 in wildlife

Here, we have developed an improved system to measure Cs-137 in wildlife at the Savannah River Site. This field-portable system consists of a shielded 5 cm by 10 cm by 40 cm NaI detector controlled by an Ametek Ortec Digibase. Measurement of an animal’s radioactivity is made by placing the animal at a predefined location on the detector system for a one minute count-time. The counts, animal type, and animal weight are then used as inputs to an algorithm which calculates the amount of Cs-137 within the whole animal and within the edible meat portion of the animal. The results from these calculations are used to estimate the received dose from eating this animal and is included in the Savannah River Site’s Hunter Dose Tracking System. This system has a detection limit of 0.60 pCi/g (22.20 Bq/kg) with a typical measurement uncertainty of less than 0.32 pCi/g (11.84 Bq/kg).

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

The Urban Deployment Model: A Toolset for the Simulation and Performance Characterization of Radiation Detector Deployments in Urban Environments

Static and mobile radiation detectors can be deployed in urban environments for a range of nuclear security applications, including radiological source search-and-tracking scenarios. Modeling detector performance for such applications is challenging, as it does not depend solely on the detector capabilities themselves. Many factors must be taken into consideration, including specific source and background signatures, the topology and constraints of the deployment environment, the presence of nuisance sources, and whether detectors are mobile or static. When considering the simultaneous deployment of multiple, heterogeneous detectors, assessment of the system-wide performance requires the simulation of the individual detectors, and a system-level analysis of the detection performance. In radiological source search-and-tracking scenarios, performance is mostly dominated by the probability of encounter, which depends on the specifics of a given deployment, e.g., static vs. mobile detectors or a combination of both modalities, the number of detectors deployed, the dynamic vs. static setting of false alarm rates, and individual vs. networked operation. The Urban Deployment Model (UDM) toolset was specifically developed to cover the gap in the available generic frameworks for the simulation of radiation detector deployments at city scales. UDM provides a unified and modular framework to support the simulation and performance characterization of heterogeneous detector deployments in urban environments. This paper presents the key components along the UDM workflow.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A Qualitative Strategy for Fusion of Physics into Empirical Models for Process Anomaly Detection

To facilitate the automated online monitoring of power plants, a systematic and qualitative strategy for anomaly detection is presented. This strategy is essential to provide credible reasoning on why and when an empirical versus hybrid (i.e., physics-supported) approach should be used and to determine the ideal mix of these two approaches for a defined anomaly detection scope. Empirical methods are usually based on pattern, statistical, and causal inference. Hybrid methods include the use of physics models to train and test data methods, reduce data dimensionality, reduce data-model complexity, augment data, and reduce empirical uncertainty; hybrid methods also include the use of data to tune physics models. The presented strategy is driven by key decision points related to data relevance, simple modeling feasibility, data inference, physics-modeling value, data dimensionality, physics knowledge, method of validation, performance, data availability, and suitability for training and testing, cause-effect, entropy inference, and model fitting. The strategy is demonstrated through a pilot use case for the application of anomaly detection to capture a valve packing leak at the high-pressure coolant injection system of a nuclear power plant.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A potential probe of Fundamental Interactions using Multi-Modal Cosmic Ray events

The Horizon-T experiment in Tien Shan is based on the idea of measuring the time at which EAS disc passes the observation level with nanosecond accuracy. The detector system consists of ten charged particles registration points located at distances of up to several hundred meters from each other. The points are equipped with detectors based on registration of Cherenkov radiation in glass and registration of scintillation light in polystyrene. The detectors register the arrival times of charged particles at the observation level with a resolution of ~2 ns, as required to study the spatial and temporal characteristics of the EAS and the structure of the multi-modal events specifically. Over the period of the Horizon-T data taking since 2017 to present, a large number of multi-modal events were detected. The data has presented numerous challenges that show the direction towards the further development of the detector system and of the analysis methods and techniques that could be applied to these multi-modal events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A new μ -high energy resolution fluorescence detection microprobe imaging spectrometer at the Stanford Synchrotron Radiation Lightsource beamline 6-2

In this report we describe a new synchrotron X-ray Fluorescence (XRF) imaging instrument with an integrated High Energy Fluorescence Detection X-ray Absorption Spectroscopy (HERFD-XAS) spectrometer at the Stanford Synchrotron Radiation Lightsource at beamline 6-2. The X-ray beam size on the sample can be defined via a range of pinhole apertures or focusing optics. XRF imaging is performed using a continuous rapid scan system with sample stages covering a travel range of 250 × 200 mm 2 , allowing for multiple samples and/or large samples to be mounted. The HERFD spectrometer is a Johann-type with seven spherically bent 100 mm diameter crystals arranged on intersecting Rowland circles of 1 m diameter with a total solid angle of about 0.44% of 4π sr. A wide range of emission lines can be studied with the available Bragg angle range of ~64.5°–82.6°. With this instrument, elements in a sample can be rapidly mapped via XRF and then selected features targeted for HERFD-XAS analysis. Furthermore, utilizing the higher spectral resolution of HERFD for XRF imaging provides better separation of interfering emission lines, and it can be used to select a much narrower emission bandwidth, resulting in increased image contrast for imaging specific element species, i.e., sparse excitation energy XAS imaging. This combination of features and characteristics provides a highly adaptable and valuable tool in the study of a wide range of materials.

47 OTHER INSTRUMENTATION↗

Experimental Report: Multi-Instrument Comparison of AAF Condensation Particle Counters

Condensation particle counters (CPCs), also known as condensation nucleus counters (CNCs) are sophisticated instruments designed to measure the concentration of aerosol particles in the atmosphere. These devices are pivotal in environmental monitoring, industrial applications, and scientific research, particularly in atmospheric studies. CPCs are vital for understanding the role of aerosols in climate systems. Aerosols influence cloud formation, radiative forcing, and atmospheric chemistry. By providing accurate measurements of particle concentrations and distributions, CPCs contribute to models that predict atmospheric impact and weather patterns (Mei et al. 2021). CPCs operate by enlarging submicron particles, including those as small as a few nanometers, to sizes detectable by optical methods. This report delves into the mechanisms, importance, and contributions of CPCs to atmospheric research at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Aerial Facility (AAF), highlighting their role in advancing air quality assessment, pollution control, and atmospheric studies.

54 ENVIRONMENTAL SCIENCES↗

Emulating Variable Uranium Enrichments With Radiation Signature Training Devices (RSTD)

Radiological signature training devices (RSTDs) are sealed sources (or assemblies of sources) that emulate the radiation signature of larger masses of special nuclear material for passive detection while maintaining a minimal logistical footprint in security, radiological safety, criticality safety, and transportation requirements. Previous work focused on emulation of large quantities of highly enriched uranium for search and field identification with radioisotope identification detectors and mobile systems. New work has expanded into investigating use of the RSTDs with laboratory safeguards tools, such as MGAU and FRAM, and emulating uranium spectra of multiple enrichments over more energy regions (particularly the x-ray region).

Blessinger, Christopher S.↗