Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Quantum metasurface for multiphoton interference and state reconstruction

Metasurfaces based on resonant nanophotonic structures have enabled innovative types of flat-optics devices that often outperform the capabilities of bulk components, yet these advances remain largely unexplored for quantum applications. Here, we show that nonclassical multiphoton interferences can be achieved at the subwavelength scale in all-dielectric metasurfaces. We simultaneously image multiple projections of quantum states with a single metasurface, enabling a robust reconstruction of amplitude, phase, coherence, and entanglement of multiphoton polarization-encoded states. One- and two-photon states are reconstructed through nonlocal photon correlation measurements with polarization-insensitive click detectors positioned after the metasurface, and the scalability to higher photon numbers is established theoretically. Our work illustrates the feasibility of ultrathin quantum metadevices for the manipulation and measurement of multiphoton quantum states, with applications in free-space quantum imaging and communications.

42 ENGINEERING↗

Infrared hyperspectral imaging using a broadly tunable external cavity quantum cascade laser and microbolometer focal plane array

A versatile mid-infrared hyperspectral imaging system is demonstrated by combining a broadly tunable external cavity quantum cascade laser and a microbolometer focal plane array. The tunable mid-infrared laser provided high brightness illumination over a tuning range from 985 cm-1 to 1075 cm-1 (9.30-10.15 μm). Hypercubes containing images at 300 wavelengths separated by 0.3 cm 1 were obtained in 12 s. High spectral resolution chemical imaging of methanol vapor was demonstrated for both static and dynamic systems. The system was also used to image and characterize multiple component liquid and solid samples.

10 SYNTHETIC FUELS↗

Intrinsic and induced quantum quenches for enhancing qubit-based quantum noise spectroscopy

Quantum sensing protocols that exploit the dephasing of a probe qubit are powerful and ubiquitous methods for interrogating an unknown environment. They have a variety of applications, ranging from noise mitigation in quantum processors, to the study of correlated electron states. Here, we discuss a simple strategy for enhancing these methods, based on the fact that they often give rise to an inadvertent quench of the probed system: there is an effective sudden change in the environmental Hamiltonian at the start of the sensing protocol. These quenches are extremely sensitive to the initial environmental state, and lead to observable changes in the sensor qubit evolution. We show how these new features give access to environmental response properties. This enables methods for direct measurement of bath temperature, and for detecting non-thermal equilibrium states. We also discuss how to deliberately control and modulate this quench physics, which enables reconstruction of the bath spectral function. Extensions to non-Gaussian quantum baths are also discussed, as is the application of our ideas to a range of sensing platforms (e.g., nitrogen-vacancy (NV) centers in diamond, semiconductor quantum dots, and superconducting circuits).

59 BASIC BIOLOGICAL SCIENCES↗

Independent Panel Report for Technical Assessment of NASA and External Quantum Sensing Capabilities

Sensors based on quantum mechanical properties of electromagnetic radiation and matter offer unique capabilities and performance sometimes difficult to achieve using classical approaches. This report assesses the suitability of quantum sensing for current and future NASA needs, with a specific focus on NASA’s Science Mission Directorate (SMD). Measurement and sensing needs across NASA SMD are reviewed as a driver for the possible incorporation of existing quantum sensors into the NASA portfolio and the development of next-generation quantum sensors. A range of quantum sensing modalities is then described and the current state of the art for each sensor is presented. Current research and development activities on quantum sensing within NASA are compared with the range of activities ongoing throughout the broader scientific community, both within the United States and internationally. In conclusion, there is considerable advantage to be gained by NASA from quantum sensors through the growth of internal programs and collaboration with outside entities.

Quantum Sensing↗

Image-to-Image Wildfire Detection via Quantum-Compatible Variational Segmentation from Remotely-sensed Data

Over the last decade, the incidence of wildfires has surged, causing widespread destruction globally. To better comprehend and manage these incidents, remote sensing and aerial missions have been implemented in recent efforts. However, this has resulted in an exponential rise in the amount of remote sensing data utilization, leading to a need for intelligent automation of data extraction in wildfire studies. Machine learning provides an accurate automated approach for detecting these natural anomalies and facilitates decision-makers to take prompt actions. To make insightful decisions in wildfire management, it is imperative to move beyond simple detection and explore the potential of probabilistic generative machine learning for creating "what-if" scenarios for various wildfire conditions. Such models offer improved representation of the stochastic nature of wildfire events. However, the optimization of these models can be computationally expensive, especially when using classical computers. Quantum computers have recently emerged as a promising solution to reduce the computational cost of training such models and improve their performance. In this study, we aim to utilize quantum-compatible machine learning techniques to implement our probabilistic generative approach. To that end, we propose a supervised probabilistic variational model consisting of a U-NET-based image-to-image component along with encoder and decoder networks which work as a variational autoencoder (VAE) component. Additionally, we explore the type of latent distribution type in the VAE component and implement different means for modeling the prior distribution. We further investigate the quantum-compatible versions of the model compared to the classical counterpart and benchmark potential benefits of quantum compatibility over the classical model.

quantum machine learning↗

Nanoscale electric field imaging with an ambient scanning quantum sensor microscope

Nitrogen-vacancy (NV) center in diamond is a promising quantum sensor with remarkably versatile sensing capabilities. While scanning NV magnetometry is well-established, NV electrometry has been so far limited to bulk diamonds. Here we demonstrate imaging external alternating (AC) and direct (DC) electric fields with a single NV at the apex of a diamond scanning tip under ambient conditions. A strong electric field screening effect is observed at low frequencies. We quantitatively measure its frequency dependence and overcome this screening by mechanically oscillating the tip for imaging DC fields. Our scanning NV electrometry achieved an AC E-field sensitivity of 26 mV μm -1 Hz -1/2 , a DC E-field gradient sensitivity of 2 V μm -2 Hz -1/2 , and sub-100 nm resolution limited by the NV-sample distance. Our work represents an important step toward building a scanning-probe-based multimodal quantum sensing platform.

47 OTHER INSTRUMENTATION↗

SU-E-I-40: New Method for Measurement of Task-Specific, High-Resolution Detector System Performance

Purpose: Although generalized linear system analytic metrics such as GMTF and GDQE can evaluate performance of the whole imaging system including detector, scatter and focal-spot, a simplified task-specific measured metric may help to better compare detector systems. Methods: Low quantum-noise images of a neuro-vascular stent with a modified ANSI head phantom were obtained from the average of many exposures taken with the high-resolution Micro-Angiographic Fluoroscope (MAF) and with a Flat Panel Detector (FPD). The square of the Fourier Transform of each averaged image, equivalent to the measured product of the system GMTF and the object function in spatial-frequency space, was then divided by the normalized noise power spectra (NNPS) for each respective system to obtain a task-specific generalized signal-to-noise ratio. A generalized measured relative object detectability (GM-ROD) was obtained by taking the ratio of the integral of the resulting expressions for each detector system to give an overall metric that enables a realistic systems comparison for the given detection task. Results: The GM-ROD provides comparison of relative performance of detector systems from actual measurements of the object function as imaged by those detector systems. This metric includes noise correlations and spatial frequencies relevant to the specific object. Additionally, the integration bounds for the GM-ROD can be selected to emphasis the higher frequency band of each detector if high-resolution image details are to be evaluated. Examples of this new metric are discussed with a comparison of the MAF to the FPD for neuro-vascular interventional imaging. Conclusion: The GM-ROD is a new direct-measured task-specific metric that can provide clinically relevant comparison of the relative performance of imaging systems. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Micropuncture of Bowman's Space in Mice Facilitated by 2 Photon Microscopy

Renal micropuncture and renal 2-photon imaging are seminal techniques in renal physiology. However, micropuncture is limited by dependence on conventional microscopy to surface nephron features, and 2-photon studies are limited in that interventions can only be assessed at the organ, rather than the nephron level. In particular, micropuncture studies of the glomeruli of mice have been challenged by the paucity of surface glomeruli in mice. To address this limitation in order to pursue studies of aspirate from Bowman's space in mouse physiologic models, we developed 2-photon glomerular micropuncture. We present a novel surgical preparation that allows lateral access to the kidney while preserving the required vertical imaging column for 2-photon microscopy. Administration of high molecular weight fluorescein isothiocyanate (FITC)- dextran is used to render the renal vasculature and therefore glomeruli visible for 2-photon imaging. A quantum dot-coated pipette is then introduced under stereotactic guidance to a glomerulus selected from the several to many which may be visualized within the imaging window. In this protocol, we provide details of the preparation, materials, and methods necessary to carry out the procedure. This technique facilitates previously-impossible physiologic study of the kidney, including recovery of filtrate from Bowman's space and all segments of the nephron within the imaging depth limit, about 100 µm below the renal capsule. Pressure, charge and flow may all be measured using the introduced pipette. Here, we provide representative data from liquid chromatography/mass spectrometry performed on aspirate from Bowman's space. We expect this technique to have wide applicability in renal physiologic investigation.

Matsushita, Katsuyuki↗

SU-F-I-80: Correction for Bias in a Channelized Hotelling Model Observer Caused by Temporally Variable Non-Stationary Noise

Purpose: Application of a channelized Hotelling model observer (CHO) over a wide range of x-ray angiography detector target dose (DTD) levels demonstrated substantial bias for conditions yielding low detectability indices (d’), including low DTD and small test objects. The purpose of this work was to develop theory and methods to correct this bias. Methods: A hypothesis was developed wherein the measured detectability index (d’b) for a known test object is positively biased by temporally variable non-stationary noise in the images. Hotelling’s T2 test statistic provided the foundation for a mathematical theory which accounts for independent contributions to the measured d’b value from both the test object (d’o) and non-stationary noise (d’ns). Experimental methods were developed to directly estimate d’o by determining d’ns and subtracting it from d’b, in accordance with the theory. Specifically, d’ns was determined from two sets of images from which the traditional test object was withheld. This method was applied to angiography images with DTD levels in the range 0 to 240 nGy and for disk-shaped iodine-based contrast targets with diameters 0.5 to 4.0 mm. Results: Bias in d’ was evidenced by d’b values which exceeded values expected from a quantum limited imaging system and decreasing object size and DTD. d’ns increased with decreasing DTD, reaching a maximum of 2.6 for DTD = 0. Bias-corrected d’o estimates demonstrated sub-quantum limited performance of the x-ray angiography for low DTD. Findings demonstrated that the source of non-stationary noise was detector electronic readout noise. Conclusion: Theory and methods to estimate and correct bias in CHO measurements from temporally variable non-stationary noise were presented. The temporal non-stationary noise was shown to be due to electronic readout noise. This method facilitates accurate estimates of d’ values over a large range of object size and detector target dose.

60 APPLIED LIFE SCIENCES↗

Proposal for dynamic imaging of antiferromagnetic domain wall via quantum-impurity relaxometry

While spin textures in materials exhibiting zero net magnetization, such as antiferromagnetic domain walls, have attracted much interest lately due to their robustness against external magnetic noise, their generic detection via conventional magnetometry remains a challenging task. Here, we propose quantum relaxometry as a route to image spin textures by probing the collective spin modes harbored by them. We investigate the Goldstone modes hosted by an antiferromagnetic domain wall and assess the relaxation rate of a quantum-spin sensor interacting with them. Furthermore, we show that such modes can be detected via relaxometry in some common antiferromagnets. Moreover, based on symmetry considerations, we propose a strategy for probing the individual dynamics of each mode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Flexible Soft X-Ray Image Sensors based on Metal Halide Perovskites With High Quantum Efficiency

Soft X-ray imaging is a powerful tool to explore the structure of cells, probe material with nanometer resolution, and investigate the energetic phenomena in the universe. Conventional soft X-ray image sensors are by and large Si-based charge coupled devices that suffer from low frame rates, complex fabrication processes, mechanical inflexibility, and required cooling below -60 °C. Here, a soft X-ray photodiode is reported based on low-cost metal halide perovskite with comparable performance to commercial Si-based device. Nanothrough network electrode minimized the optical loss due to the shadowing of insensitive layers, while a multidimensional perovskite heterojunction is generated to reduce the photo-generated carrier loss. Further, this strategy promoted a record quantum efficiency of 8 × 10 3 % without cooling, several orders of magnitude greater than the previously achieved. Flexible and curved soft X-ray imaging arrays are fabricated based on this high-performance device structure, demonstrating stable soft X-ray response and sharp imaging capabilities. This work highlights the low-cost and efficient perovskite photodiode as a strong candidate for the next-generation soft X-ray image sensors.

36 MATERIALS SCIENCE↗

Inorganic semiconductor quantum dots as a saturated excitation (SAX) probe for subdiffraction imaging

The photoluminescence (PL) saturation of CdSe/ZnS core/shell inorganic semiconductor quantum dots (QDs) and its utility as a probe for saturated excitation (SAX) microscopy are reported. Under saturating excitation power densities, the PL signal was demodulated and recorded at harmonics of the fundamental frequency. For commercially available Qdot® 655 ITK™ QDs, the power density required to achieve saturation was dependent upon the local environment of the QDs. For QDs deposited and dried on a glass substrate, the excitation power density required for PL saturation was less than 1 kW/cm 2 . Compared to this, saturation of PL for QDs dispersed in water required an excitation power density greater than 200 kW/cm 2 . This observation is manifested as a limitation in the imaging of hydrated samples, as demonstrated for HeLa cells labelled with biotinylated-phalloidin followed by labelling with streptavidin-coated QDs. Finally as saturation affects the obtained spatial resolution in several imaging formats, including confocal imaging, the provided data will aid in obtaining the optimal spatial resolution when using QD probes to image biological samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of the quantum superposition state of an imaging ensemble of photons prepared in orbital angular momentum states using a phase-diversity method

We propose the use of a phase-diversity technique to estimate the orbital angular momentum (OAM) superposition state of an ensemble of photons that passes through an optical system, proceeding from an extended object. The phase-diversity technique permits the estimation of the optical transfer function (OTF) of an imaging optical system. As the OTF is derived directly from the wave-front characteristics of the observed light, we redefine the phase-diversity technique in terms of a superposition of OAM states. We test this new technique experimentally and find coherent results among different tests, which gives us confidence in the estimation of the photon ensemble state. We find that this technique not only allows us to estimate the square of the amplitude of each OAM state, but also the relative phases among all states, thus providing complete information about the quantum state of the photons. This technique could be used to measure the OAM spectrum of extended objects in astronomy or in an optical communication scheme using OAM states. In this sense, the use of extended images could lead to new techniques in which the communication is further multiplexed along the field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atom chips with two-dimensional electron gases: Theory of near-surface trapping and ultracold-atom microscopy of quantum electronic systems

We show that current in a two-dimensional electron gas (2DEG) can trap ultracold atoms <1 {mu}m away with orders of magnitude less spatial noise than a metal trapping wire. This enables the creation of hybrid systems, which integrate ultracold atoms with quantum electronic devices to give extreme sensitivity and control: For example, activating a single quantized conductance channel in the 2DEG can split a Bose-Einstein condensate (BEC) for atom interferometry. In turn, the BEC offers unique structural and functional imaging of quantum devices and transport in heterostructures and graphene.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spin Squeezing by Rydberg Dressing in an Array of Atomic Ensembles

Here, we report on the creation of an array of spin-squeezed ensembles of cesium atoms via Rydberg dressing, a technique that offers optical control over local interactions between neutral atoms. We optimize the coherence of the interactions by a stroboscopic dressing sequence that suppresses super-Poissonian loss. We thereby prepare squeezed states of N = 200 atoms with a metrological squeezing parameter ξ 2 = 0.77⁢(9) quantifying the reduction in phase variance below the standard quantum limit. We realize metrological gain across three spatially separated ensembles in parallel, with the strength of squeezing controlled by the local intensity of the dressing light. Our method can be applied to enhance the precision of tests of fundamental physics based on arrays of atomic clocks and to enable quantum-enhanced imaging of electromagnetic fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fault localization in a microfabricated surface ion trap using diamond nitrogen-vacancy center magnetometry

Here, as quantum computing hardware becomes more complex with ongoing design innovations and growing capabilities, the quantum computing community needs increasingly powerful techniques for fabrication failure root-cause analysis. This is especially true for trapped-ion quantum computing. As trapped-ion quantum computing aims to scale to thousands of ions, the electrode numbers are growing to several hundred, with likely integrated photonic components also adding to the electrical and fabrication complexity, making faults even harder to locate. In this work, we used a high-resolution quantum magnetic imaging technique, based on nitrogen-vacancy centers in diamond, to investigate short-circuit faults in an ion trap chip. We imaged currents from these short-circuit faults to ground and compared them to intentionally created faults, finding that the root cause of the faults was failures in the on-chip trench capacitors. This work, where we exploited the performance advantages of a quantum magnetic sensing technique to troubleshoot a piece of quantum computing hardware, is a unique example of the evolving synergy between emerging quantum technologies to achieve capabilities that were previously inaccessible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Colloidal quantum dots for optoelectronics

Colloidal quantum dots (QDs) are semiconductor nanocrystals that have unique size-tunable optoelectronic properties and are suitable for wet processing. QD research aims to answer fundamental questions about the chemical and physical properties of nanoscale materials and use these tools for technological applications ranging from bio-imaging to quantum optics. At the core of this field is a set of synthetic, processing and analytical methods designed to produce QDs in uniform ensembles that meet the highest performance standards. Here, this Primer reviews QD fabrication methods with a focus on the applications of QDs in printed optoelectronics and quantum optics. After outlining the current state-of-the-art QD syntheses, the experimental and computational analysis of QDs is discussed. These topics are then connected to the methodologies, processes and concepts required for developing QD-based photodetectors, light-emitting devices and quantum optics applications. Special attention is paid to challenges in reproducibility and current limitations of the field, such as the need to balance non-restricted material composition with high performing technology while achieving long-term stability in QD devices under operating conditions. Finally, the ongoing advancement in QD synthesis, precise atomic-level analysis and computational methodologies are highlighted as key drivers towards rational QD design, particularly in understanding how structural changes under loading impact QD properties.

optical materials↗