Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pumps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Optimization of a Residential Air Source Heat Pump using Refrigerants with GWP <150 for Improved Performance and Reduced Emission

Using low-GWP refrigerants can reduce the Green House Gas (GHG) emission of heat pump systems. Heat exchangers and compressors are the key components and have a prominent impact on system performance, significant research is devoted to reducing the cost of the heat exchangers while achieving the same or better system performance with refrigerant charge reduction.To better understand the environmental impacts of optimized systems with low-GWP refrigerants, Life Cycle Climate Performance (LCCP) evaluation method was used to evaluate the direct and indirect emissions of the system over the course of its lifetime from manufacturing to disposal. The DOE/ORNL Heat Pump Design Model (HPDM) is used to evaluate the performance of heat pumps. Multi-objective optimizations using Particle Swarm Optimization (PSO) algorithm are performed on a 3-ton R410A residential air source heat pump on market. Seven R410A alternatives, i.e., R32, R454B, R454C, R455A, R457A, R1234yf and R1234ze(E) are investigated. The last five fluids have GWP lower than 150.As a result, 5.5%-12.8% seasonal energy efficiency ratio 2 (SEER2) improvement is achieved, and the optimized systems reduce life cycle CO2 emission by 8.5%-28.6% with GWP lower than 150 refrigerants. The optimal heat exchangers can fit into the original R410A fan-coil units; therefore, the proposed design method establishes a production and installation path to produce cost-effective low-GWP heat pumps easily accepted by end users.

Li, Zhenning↗

Microfluidic systems, pumps, valves, fluidic chips thereof, and applications of same

Microfluidic systems, pumps, valves and applications of the same are provided. The microfluidic system may be a pump or a valve having a fluidic chip and an actuator controlling the opening and closing of the fluidic channel in the fluidic chip. The actuator may be disposed to tilt from the fluidic chip, forming a tilted-rotor peristaltic pump. Alternatively, the actuator may be a rolling ball actuator, and different fluidic chips may be used in different applications. For example, the fluidic chip may be a spiral pump chip having spiral channels, a rotary peristaltic pump chip having multiple output channels, or a multi-port valve chip having one port interconnected with multiple different ports. An analytical valve chip may switchably interconnect bioreactor and rinse/calibration input channels to sensor and waste output channels. The actuator of a random-access valve can move from one valve position to another without opening or closing intermediate ones.

Reiserer, Ronald S.↗

Heat Exchangers Circuitry Optimization using Low-GWP Refrigerants in Reversible Heat Pump Applications

Tube-fin heat exchangers (TFHX) are widely used in heat pump applications. Circuitry optimization can improve system performance. Previous optimizations focus on improving component-level performance under a specific operating condition, i.e., the TFHX either works as a condenser or an evaporator. The optimal circuitry obtained under air conditioning (AC) mode cannot guarantee optimal performance when used in heat pump (HP) mode. This study implements a bi-objective formulation to achieve optimal system performance in both AC and HP modes. An integer permutation-based Genetic Algorithm is integrated with Heat Pump Design Model (HPDM) to perform heat pump optimization. Six refrigerants, i.e., R410A, R452B, R454B, R32, D2Y60 and L41a are investigated. Case studies show that optimal heat exchangers yield 2.1%-6.1% EER improvement under AC mode and 1.9%-8.5% COP improvement under HP mode. Use of this design approach can help assure a preferable performance of reversible heat pumps during both cooling and heating mode usage.

Li, Zhenning↗

Microfluidic systems, pumps, valves, fluidic chips thereof, and applications of same

Microfluidic systems, pumps, valves and applications of the same are provided. The microfluidic system may be a pump or a valve having a fluidic chip and an actuator controlling the opening and closing of the fluidic channel in the fluidic chip. The actuator may be disposed to tilt from the fluidic chip, forming a tilted-rotor peristaltic pump. Alternatively, the actuator may be a rolling ball actuator, and different fluidic chips may be used in different applications. For example, the fluidic chip may be a spiral pump chip having spiral channels, a rotary peristaltic pump chip having multiple output channels, or a multi-port valve chip having one port interconnected with multiple different ports. An analytical valve chip may switchably interconnect bioreactor and rinse/calibration input channels to sensor and waste output channels. The actuator of a random-access valve can move from one valve position to another without opening or closing intermediate ones.

Reiserer, Ronald S.↗

Multifunctional Heat Pump with Energy Storage Capability

Replacing gas furnaces with heat pumps on a large scale can pose challenges to the electrical grid. It will significantly increase the demand, strain the electrical grid, especially during peak usage times. To ensure that heat pumps contribute to reducing emissions, it's essential to increase the share of renewable energy in the grid. However, the supply of renewable energy is unstable. Large scale of electrification must address the concern of grid resilience to meet necessary heating/cooling demands and shift peak electric load. All these require future heat pumps having energy storage capability. These systems can store excess energy during low-demand periods and release it during high-demand periods, reducing stress on the grid. This paper will introduce an innovative configuration, control, and laboratory investigations of a multifunctional packaged heat pump. In addition to the original indoor and outdoor air coils, the heat pump has a parallel hydronic loop with a brazed plate heat exchanger (BHP). The hydronic loop circulates hot/chilled water to store heating/cooling energy in phase change material (PCM). It is capable of space cooling, space heating, cooling energy storage/defrosting, water heating/heating energy storage with outdoor air source or indoor air source, and cooling/heating energy free discharge. The laboratory studies and breadboard unit are presented. Additionally, building energy simulation demonstrates utility cost reduction potential via charging PCM panels/ceilings during off-peak hours and releasing the energy during peak hours to mitigate the peak power consumption.

Shen, Bo↗

Residential Integrated Heat Pump to Meet All the Home Comfort Needs

This paper will introduce development and field trial of a residential air-source integrated heat pump for cold climates. The heat pump is multi-functional to meet all the home comfort demands, including space cooling, space heating, domestic water heating. The integrated heat pump is an ideal solution to decarbonize northern homes via providing efficient space heating and water heating to replace natural gas. It uses a three-stage compressor and a single set of heat exchangers and valves to deliver all the functions, and thus achieve cost reduction. We developed an innovative system configuration and related controls to solve typical charge unbalance, accelerate charge migration and smoothen mode transition in integrated heat pumps. Laboratory investigations were conducted for individual modes and verified the control functions. Laboratory tests demonstrated that the unit delivered outstanding performance. It achieved 17.0 SEER (seasonal cooling energy efficiency rating) and 11.0 HSPF (heating seasonal performance factor). In the most efficient mode (combined space cooling and water heating mode), the unit reached a total energy efficiency > 30.0 EER and required only 25 minutes to heat a 50-gallon tank of water. One heat pump prototype is going through a field trial since April, 2023 in Syracuse, New York. The one-year field test results are summarized.

Shen, Bo↗

Deployable Element Ultra High Vacuum Pump

Most existing vacuum pump technologies remain stationary, limiting their effectiveness in a molecular environment. In low vacuum environments, molecules move in a particular path towards the source of pumping. As the mean-free-path increases, the system’s ability to capture molecules diminishes and pump-down time increases. To address this, the team explored various designs that would deploy the pump surface closer to the molecules. After several iterations, a “windmill” shape for the final design. This design employs titanium sublimation technology in a deployable configuration, effectively reducing the distance between residual molecules and the pump surfaces, thereby minimizing randomness and improving particle capture.

Etayem, Brandon [Northern Illinois U.]↗

A critical review of electrochemical heat pump technologies: Status, challenges, and perspectives

The development of advanced heat pump technologies is critical for reducing global energy consumption in the building sector, where space heating and cooling account for nearly 50% of energy use. Electrochemical heat pumps (EHPs) offer a promising alternative to vapor compression systems by enabling direct electrochemical-to-thermal energy conversion, often with environmentally benign working fluids that exhibit low or zero global warming potential (GWP). Prior literature has predominantly focused on chemically reactive heat pumps, while comprehensive assessments of electrochemical mechanisms remain limited. Here, this review addresses this gap by systematically evaluating the underlying principles, architectures, and performance metrics of EHP systems. Compared to conventional vapor compression systems, EHPs can achieve 10%-30% higher energy efficiency, with reported cooling coefficients of performance (COP c ) ranging from 3.5 to 14.3 under standard operating conditions. Despite these advantages, widespread adoption is hindered by challenges including membrane degradation, electrode fouling, sluggish redox kinetics, and elevated system-level capital costs. To address these limitations, the review outlines three research priorities: (i) the development of advanced membranes, catalysts, and electrode materials with enhanced chemical and mechanical stability; (ii) the application of molecular-level simulations for the rational design of high-performance redox-active working fluids; and (iii) the integration of advanced diagnostic techniques for real-time monitoring and sustained operation of EHPs. By consolidating recent advances and explicitly identifying technological and scientific gaps, this work uniquely contributes a comprehensive framework for guiding future electrochemical heat pump research and facilitating the transition to sustainable thermal management technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Polarizing 3 He via metastability exchange optical pumping using a 1.2 mbar sealed cell at magnetic fields up to 5 T

Here, we report high nuclear polarization of 1.2 mbar 3 He gas in a sealed cell in magnetic fields up to 5 T using Metastability Exchange Optical Pumping (MEOP). The creation of a highly polarized 3 He gas target for use in the 5 T field of Jefferson Lab’s CLAS12 spectrometer would enable new studies of spin-dependent asymmetries on the neutron. We describe a systematic study which was conducted for the first time up to the full 5 T field required for the final target design to evaluate the effects of discharge intensity, pump laser power, and optical pumping transition schemes on nuclear polarization and pumping rates. Steady-state polarizations up to 86% in magnetic fields between 2 and 5 T were achieved, with a discharge-on relaxation time of 898 s at 5 T. These results underscore the potential of MEOP for high-field applications in nuclear physics experiments.

3He polarization↗

Optically pumped semiconductor laser based on a type-II CdS/ZnSe heterostructure

An optically pumped semiconductor laser based on a type-II CdS/ZnSe nanoheterostructure containing 10 quantum wells (QWs) was studied. The structure was grown by metal-organic vapour phase epitaxy on a GaAs substrate. The lifetime of electron-hole pairs at a low pump level was measured by luminescence decay to be ∼0 ns. The peak power of the microcavity semiconductor laser at room temperature and longitudinal pumping by a repetitively pulsed N{sub 2} laser was 7.2 W at a wavelength of 514 nm. The relatively low laser slope efficiency (0.35 %) is explained by amplified spontaneous emission propagating along the structure. The peak power and efficiency of the laser in the case of transverse pumping increase to 70 W and 3.5 %, respectively. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units

The heat pump rooftop units (RTUs) measure replaces gas furnace and electric resistance RTUs with high-efficiency heat pump rooftop units (HP-RTUs). The HP-RTUs are intended to be top-of-the line, including high-efficiency fans and heat pump systems. The fans are variable speed, allowing the HP-RTUs to operate as single-zone variable air volume systems. The heat pumps are also variable speed, allowing for high part load performance. All schedules in the existing RTUs are transferred to the new HP-RTUs for consistency. Furthermore, any energy efficiency features in the existing baseline RTUs such as energy recovery or economizers are also transferred to the new HP-RTUs for consistency. This measure is applicable to approximately 45% of the ComStock floor area. The HP-RTU measure demonstrates 10.3% total site energy savings (449 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Emerging Technologies Review: Pumped Storage Hydropower

The Air Force Civil Engineer Center (AFCEC) has tasked Pacific Northwest National Laboratory with investigating emerging technologies to inform the Air Force’s understanding of the technology and to guide key considerations for implementing technologies that are resilient and alternative sources to the traditional methods used in the Air Force today. This report explores pumped storage hydropower. Pumped storage hydropower (PSH) currently provides 93% of grid-scale storage capacity (MW) and 99% of electrical energy storage (MWh) in the United States. PSH exploits the potential energy that can be stored by pumping water to higher elevations or pressures to be dispatched when needed. In its simplest form, PSH uses energy to pump water to an upper reservoir for storage, then releases this water through a turbine and generator into a lower reservoir when needed for energy generation. This report provides a thorough technology description, technical considerations, siting considerations, economic/funding considerations associated with the technology. A Regulatory overview and risks associated with the technology are also included in the report.

13 HYDRO ENERGY↗

Closed Loop Pumped Storage Hydropower Resource Assessment of the United States

The data includes a geospatial and spreadsheet representation of a resource analysis for closed loop pumped storage systems across the Continental United States, Alaska, Hawaii, and Puerto Rico. The data includes energy storage potential, water volume, distance from source to storage, hydraulic head, dollars per kilowatt of storage, and transmission spurline cost for each pumped storage hydropower (PHS) reservoir. Each reservoir represented in this dataset is represented on potential 10 hour storage duration PSH system comprised of two reservoirs. Units of measure are laid out in the dataset. Pumped storage hydropower (PSH) represents the bulk of the United States' current energy storage capacity: 23 gigawatts (GW) of the 24 GW national total (Denholm et al. 2021). This capacity was largely built between 1960 and 1990. PSH is a mature and proven method of energy storage with competitive round-trip efficiency and long life spans. These qualities make PSH a very attractive potential solution to energy storage needs, particularly for longer-duration storage (8 hours or more); such storage will be crucial to bridge gaps in electricity production as variable wind and solar production continue to comprise an ever-larger portion of the United States' energy portfolio. This study seeks to better understand the technical potential for PSH development in the United States by developing a national-scale resource assessment for closed-loop PSH. For more information, please refer to the Closed Loop Pumped Storage Hydropower Resource Assessment for the United States linked in the resources.

Array↗

Self‐Propelling Macroscale Sheets Powered by Enzyme Pumps

Nanoscale enzymes anchored to surfaces act as chemical pumps by converting chemical energy released from enzymatic reactions into spontaneous fluid flow that propels entrained nano‐ and microparticles. Enzymatic pumps are biocompatible, highly selective, and display unique substrate specificity. Utilizing these pumps to trigger self‐propelled motion on the macroscale has, however, constituted a significant challenge and thus prevented their adaptation in macroscopic fluidic devices and soft robotics. Using experiments and simulations, we herein show that enzymatic pumps can drive centimeter‐scale polymer sheets along directed linear paths and rotational trajectories. In these studies, the sheets are confined to the air/water interface. With the addition of appropriate substrate, the asymmetric enzymatic coating on the sheets induces chemically driven, buoyancy flows that controllably propel the sheet's motion on the air/water interface. The directionality and speed of the motion can be tailored by changing the pattern of the enzymatic coating, type of enzyme, and nature and concentration of the substrate. This work highlights the utility of biocompatible enzymes for generating motion in macroscale fluidic devices and robotics and indicates their potential utility for in vivo applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Techno-economic evaluation of industrial heat pump applications in US pulp and paper, textile, and automotive industries

Industrial process heat decarbonization through electrification could contribute significantly to climate change mitigation efforts. In the US industry, thermal processes accounted for more than two-thirds of the total final energy demand in 2021. Cross-cutting electrification technologies like industrial heat pumps are suitable for the process heat supply to several industrial unit operations in a sustainable way while also improving overall energy efficiency. This study employs a bottom-up approach to investigate the techno-enviro-economic potentials of deploying high-temperature and steam-generating heat pumps in US textile, pulp and paper, and automotive sectors in different timeframes. The results show that the annual technical potential energy and CO 2 savings by electrifying heat supply are 310 PJ (or 36% of the projected energy demand) and 28 MtCO 2 (or 71% of the projected CO 2 emissions) in 2050 respectively, however, these incur additional costs in each sector (ranging between 5 and 18 $\$$/GJ). The required heating capacity of industrial heat pumps is estimated at 15 GW, which translates roughly into a market of over 6000 heat pump units and an investment volume of $\$$7 billion in the studied processes. Although there may be individual cost-effective opportunities for electrifying heat supply in specific industrial sites, the overall costs are estimated to be high in the three industrial sectors due to the large disparity between electricity and natural gas prices and low heat source temperatures. To overcome the identified techno-economic barriers, comprehensive action plans for different stakeholders are also given. This study provides novel insights that should inform policymakers’ and executives’ decisions about the electrification of the current and future US industrial heat supply in relevant industrial sectors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Upgrade of the mechanically pumped CO 2 two-phase cooling system for the alpha magnetic spectrometer on the international space station

This study describes the successful upgrade of a mechanically pumped CO 2 two-phase cooling system in space by designing a new pump module for the Alpha Magnetic Spectrometer-02 on the International Space Station. Key factors for mission success are emphasized, including achieving high coolant filling accuracy within 10% of the target and maintaining system stability within ±1 °C. The impact of adding radiators to improve cooling efficiency is examined, and it is found that operating multi-radiators out-of-phase does not significantly affect system reliability. The centrifugal pump design is shown to allow for better lubricant circulation, while the in-house designed controller incorporates protective measures to prevent cavitation, overheating, and over-current. Further, this research advances the understanding of circulation loop systems and their upgrades in space and demonstrates the potential for extending the lifetime of space-borne mechanically pumped two-phase cooling systems.

42 ENGINEERING↗

Carbon and energy cost impacts of electrification of space heating with heat pumps in the US

In order to meet climate goals, it will be necessary to significantly reduce the greenhouse gases emitted by homes. A key factor in the US is to reduce the on-site combustion of fossil fuels for heating end-uses and to replace this with use of electric heat pump technologies connected to a low-carbon grid. The replacement of natural gas furnaces with electric heat pumps is a key home decarbonization strategy. However, the potential for space heating electrification to reduce greenhouse gas emissions depends on the carbon dioxide equivalent (CO 2 e) content of the electricity used by the heat pump. This varies considerably depending on the source of electricity, with large state to state variability. Furthermore, household energy costs are likely to be impacted by the electrification of space heating, because retail energy prices for both natural gas and electricity in each state vary by factors of seven and four, respectively. Contractors, energy programs, government and building code officials, as well as consumers need clear indications of the likely CO 2 e and energy cost impacts of proposed electrification projects, because these will affect decarbonization choices and rationales around scaled heating electrification. Government and utility programs also need to be aware of the likely outcomes of any supported/incentivized measures. Here, in this paper, we investigate these effects by looking at new metrics to analyze the change in CO 2 e emitted and the cost to meet home heating loads when switching from a natural gas furnace to a heat pump for the contiguous 48 states of the mainland US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance evaluation of underground thermal storage integrated dual-source heat pump systems

The increasing demand for electricity stresses the existing electric grids. Buildings consume 73% of all U.S. electricity and are responsible for 30% of U.S. greenhouse gas emissions. Integrating thermal energy storage (TES) in building heating/cooling systems, which consume considerable electricity, can mitigate the challenges to electric grids. Here, this study reports on a novel thermal energy storage device integrated heat pump system to reshape the building electricity demand profile while maintaining thermal comfort. The annual performance of the proposed system has been evaluated through a dynamic system simulation with high fidelity in the Modelica platform. The dynamic model of the novel hybrid component named ‘dual purpose underground thermal battery’ was developed and validated. It was then incorporated into the system model. Given a time-of-use tariff, a rule-based control strategy was designed to shift the electric demand and switch the heat pump source for a typical single-family house in different climate zones of the United States. The system performance of the new TES-integrated dual-source heat pump was compared with that of a conventional air-source heat pump system. The results indicate that the proposed system can reduce the annual HVAC electricity cost by up to 52% while saving 45.2% on electricity consumption. In the Northern areas, the annual peak load of the HVAC system can be reduced by 64.9%. However, this reduction is less in the Southern areas as the system’s higher efficiency in winter dominates the overall energy-saving potential.

25 ENERGY STORAGE↗