Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “prototype”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Analysis of an optical imaging system prototype for autonomously monitoring zooplankton in an aquaculture facility

Traditional approaches to biomonitoring in aquatic systems, such as sample collection, sorting, and identification, require significant time and effort, thereby limiting the spatiotemporal resolution of sample collection. Additionally, collection and preservation of samples for subsequent taxonomic identification and enumeration leads to mortality of organisms. Recent advances in technologies that utilize optical imaging and machine learning have provided new opportunities to expedite biomonitoring and lead to significant cost savings. These technologies can be advantageous to scientists or managers that conduct routine biomonitoring to inform operations, as in the case of aquaculture facilities. The Small Aquatic Organism optical imaging system (SAO) is a high-throughput optical imaging and classification prototype system that relies on computer vision and machine learning (Support Vector Machines, or SVMs) to autonomously identify and enumerate aquatic organisms. The SAO provides a more sustainable method of collecting large volumes of data and has the benefit of being used in situ. In this study, we tested the performance of the SAO in providing comparable results to manual zooplankton community monitoring in ten ponds at an aquaculture facility. We performed a side-by-side study comparing the sampling methods of plankton tow nets, where major zooplankton taxonomic classes were manually identified and enumerated, to sampling with the SAO. Vouchered samples were used to develop a training library for the SAO, where classes consisted of water boatman and zooplankton groups: cladocerans, copepod adults, copepod nauplii, and rotifers. SAO imagery was manually classified and compared with predicted results for validation. Accuracy for the SVM classifier of the SAO was 37.4 %. Convolutional Neural Networks (CNN) and Random Forest classifiers were also applied to SAO imagery and image features for comparison. The best CNN model and our Random Forest model had accuracies of 80.4 % and 46.6 % respectively. Challenges faced included the small size of copepod nauplii and rotifers and the limited resolution of the imaging camera, although there are tradeoffs between imaging resolution and the sample processing rate. Furthermore, our comparison shows that advancement in both optical imaging and ML are needed in order for the SAO prototype to yield comparable results to manual community monitoring in an aquaculture facility.

54 ENVIRONMENTAL SCIENCES↗

Development and experimental evaluation of an acoustic flow meter prototype for measuring air flow

Here, this study outlines the development and testing of a flow meter prototype specifically designed for use in nuclear reactor environments. The meter uses flow-induced vibration to measure flow rates and is designed for remote monitoring in harsh environments where radiation can damage electronics. The device generates a vibration signal produced by a feedback system when fluid flows out of an orifice and interacts with a downstream wedge. The frequency of the vibration signal corresponds directly to flow rate and velocity. The study investigates geometric parameters intrinsic to the prototype, such as orifice height, width, edge distance, and chamber length. Different configurations were also tested, including a bypass loop with variable cross-sections around the device. The investigation results reveal the impact of these geometric parameters on the vibration signal output, providing valuable insights for future design improvements and enhancing the effectiveness of flow metering systems used in nuclear reactor applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of prototype GE1/1 chambers for the CMS muon spectrometer upgrade

The high-luminosity phase of the Large Hadron Collider (HL-LHC) will result in ten times higher particle background than measured during the first phase of LHC operation. In order to fully exploit the highly-demanding operating conditions during HL-LHC, the Compact Muon Solenoid (CMS) Collaboration will use Gas Electron Multiplier (GEM) detector technology. The technology will be integrated into the innermost region of the forward muon spectrometer of CMS as an additional muon station called GE1/1. The primary purpose of this auxiliary station is to help in muon reconstruction and to control level-1 muon trigger rates in the pseudo-rapidity region 1.6 ≤ |η| ≤ 2.2. The new station will contain trapezoidal-shaped GEM detectors called GE1/1 chambers. The design of these chambers is finalized, and the installation is in progress during the Long Shutdown phase two (LS-2) that started in 2019. Several full-size prototypes were built and operated successfully in various test beams at CERN. Here, we describe performance measurements such as gain, efficiency, and time resolution of these prototype chambers, developed after years of R&D, and summarize their behavior in different gas compositions as a function of the applied voltage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge collection study with the ATLAS ITk prototype silicon strip sensors ATLAS17LS

The inner tracker of the ATLAS detector is scheduled to be replaced by a completely new silicon-based inner tracker (ITk) for the Phase-II of the CERN LHC (HL-LHC). The silicon strip detector covers the volume 40 < R < 100 cm in the radial and | z | < 300 cm in the longitudinal directions. The silicon sensors for the detector will be fabricated using the n + -on-p 6-inch wafer technology, for a total of 22,000 wafers. Here, intensive studies were carried out on the final prototype sensors ATLAS17LS fabricated by Hamamatsu Photonics (HPK). The charge collection properties were examined using penetrating 90 Sr β -rays and the ALIBAVA fast readout system for the miniature sensors of 1 cm × 1 cm in area. The samples were irradiated by protons in the 27 MeV Birmingham Cyclotron, the 70 MeV CYRIC at Tohoku University, and the 24 GeV CERN-PS, and by neutrons at Ljubljana TRIGA reactor for fluence values up to 2 × 10 15 n eq /cm 2 . The change in the charge collection with fluence was found to be similar to the previous prototype ATLAS12, and acceptable for the ITk. Sensors with two active thicknesses, 300 μ m (standard) and 240 μ m (thin), were compared and the difference in the charge collection was observed to be small for bias voltages up to 500 V. Some samples were also irradiated with gamma radiation up to 2 MGy, and the full depletion voltage was found to decrease with the dose. This was caused by the Compton electrons due to the 60 Co gamma radiation. To summarize, the design of the ATLAS17LS and technology for its fabrication have been verified for implementation in the ITk. We are in the stage of sensor pre-production with the first sensors already delivered in January of 2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and performance of a silicon–tungsten calorimeter prototype module and the associated readout

Here, we describe the details of a silicon–tungsten prototype electromagnetic calorimeter module and associated readout electronics. Detector performance for this prototype has been measured in test beam experiments at the CERN PS and SPS accelerator facilities in 2015/16. The results are compared to those in Monte Carlo Geant4 simulations. This is the first real-world demonstration of the performance of a custom ASIC designed for fast, lower-power, high-granularity applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A prototype hybrid mode cavity for heterodyne axion detection

In the heterodyne approach to axion detection, axion dark matter induces transitions between two modes of a microwave cavity, resulting in a parametrically enhanced signal power. We describe the fabrication and characterization of a prototype normal conducting cavity specifically optimized for heterodyne detection. Corrugations on the cavity walls support linearly polarized hybrid modes which maximize the signal power while strongly suppressing noise. We demonstrate tuning mechanisms which allow one mode frequency to be scanned across a 4 MHz range, while suppressing cross-coupling noise by at least 80 dB. A future superconducting cavity with identical geometry to our prototype would have the potential to probe orders of magnitude beyond astrophysical bounds.

Li, Zenghai [SLAC]↗

Scalable semitransparent prototype organic photovoltaic module with minimal resistance loss

Semi-transparent organic photovoltaic (ST-OPV) cells are regarded as an attractive solution to building-integrated solar energy harvesting. Both the power conversion efficiency (PCE) and average photopic transmission (APT) of ST-OPVs have shown substantial increases in recent years. However, less attention has been paid to the area scaling of ST-OPV cells. In this work, we investigate the scalability of ST-OPV cells from 4 mm 2 to 1 cm 2 , as well as 9 cm 2 active area prototype module. By integrating both top and bottom metal grids onto the transparent electrodes, the series resistance loss of 1 cm 2 ST-OPV cell is significantly reduced, and is comparable to that of the grid-free 4 mm 2 cell. Nine 1 cm 2 cells are then connected in a series-parallel circuit to realize a prototype ST-OPV module. A 100% fabrication yield with only 5% PCE deviation among discrete cells is achieved. The semitransparent module shows PCE = 7.2 ± 0.1% under simulated AM 1.5G illumination at 1 sun intensity, which exhibits no connection resistance loss compared to that of the individual cells. The ST-OPV module exhibits an APT = 38.1 ± 1.1%, which enables a light utilization efficiency, LUE = 2.74 ± 0.09%. Here, the method demonstrates a promising way for ST-OPV modules to scale without compromising performance.

14 SOLAR ENERGY↗

Crystalline symmetry-protected non-trivial topology in prototype compound BaAl 4

The BaAl 4 prototype crystal structure is the most populous of all structure types, and is the building block for a diverse set of sub-structures including the famous ThCr 2 Si 2 family that hosts high-temperature superconductivity and numerous magnetic and strongly correlated electron systems. The MA 4 family of materials (M = Sr, Ba, Eu; A = Al, Ga, In) themselves present an intriguing set of ground states including charge and spin orders, but have largely been considered as uninteresting metals. We predict the exemplary compound BaAl 4 to harbor a three-dimensional Dirac spectrum with non-trivial topology and possible nodal lines crossing the Brillouin zone, wherein one pair of semi-Dirac points with linear dispersion along the k z direction and quadratic dispersion along the k x / k y direction resides on the rotational axis with C 4 v point group symmetry. An extremely large, unsaturating positive magnetoresistance in BaAl 4 despite an uncompensated band structure is revealed, and quantum oscillations and angle-resolved photoemission spectroscopy measurements confirm the predicted multiband semimetal structure with pockets of Dirac holes and a Van Hove singularity (VHS) remarkably consistent with the theoretical prediction. We thus present BaAl 4 as a topological semimetal, casting its prototype status into a role as a building block for a vast array of topological materials.

36 MATERIALS SCIENCE↗

PM4Stell: A prototype permanent magnet stellarator structure

Permanent magnets provide a possible solution to simplify complicated stellarator coils. Here, a prototype permanent magnet stellarator structure, PM4Stell, has been funded to demonstrate the technical feasibility of using permanent magnets to create the shaping field of a stellarator. Permanent magnets in uniform cubes with three polarization directions will be carefully placed to generate the required magnetic field for a National Compact Stellarator eXperiment-like equilibrium together with planar toroidal field coils. Discrete magnets will be glued together and inserted into a “post-office-box-like” supporting structure. Electromagnetic and structural analyses have been done to validate the design. Error field correction magnets will be used to shim possible error fields. The design efforts of the prototype permanent magnet stellarator structure are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prototype tests of the electromagnetic particle injector-2 for fast time response disruption mitigation in tokamaks

Predicting and controlling disruptions is an important and urgent issue for ITER. Some disruptions with a short warning time may be unavoidable. For these cases, a fast time response disruption mitigation method is essential. Experimental tests on a prototype system of a novel, rapid time-response disruption mitigation system being developed for tokamak-based reactors and as a backup option for ITER, referred to as the electromagnetic particle injector (EPI), have been able to verify the primary advantages of the concept. These are its ability to meet short warning time scales of <10 ms while attaining the projected high velocities for deep radiative payload penetration in reactor-scale plasmas. The EPI relies on an electromagnetic propulsion system. A metallic sabot is accelerated electromagnetically to the required velocities (>1 km s -1 ) within 2 ms, at which point it releases a radiative payload consisting of a shell pellet or well-defined microspheres. Initial experimental tests from the prototype system show attainment of over 600 m s -1 in about 1 ms. Finally, essential aspects of payload separation from the sabot and sabot capture have also been demonstrated at 200 m s -1 , and the method can be extended to over 2 km s -1 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Superconducting Adaptive Gap Undulator Prototype for NSLS-II

The photon flux and brightness of synchrotron radiation, crucial parameters for any light source, vary significantly depending on the type of source employed. Among the 23 Insertion Device (ID) sources at the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Lab (BNL), the 12-year-old 3m-long In-Vacuum Undulator (IVU20) stands out for its superior performance, although it no longer represents the cutting edge of technology. Recently, there has been a shift in focus towards developing next-generation sources, particularly Superconducting Undulators (SCUs), characterized by smaller gaps, shorter periods, and maximum lengths. However, despite ongoing research and development efforts, SCUs have yet to surpass their predecessors, the Cryogenic Permanent Magnet Undulators (CPMUs), in terms of performance. This is largely attributed to the limitations posed by traditional superconducting wire, as well as challenges in the design of the magnetic structure and vacuum chamber. In this paper, we aim to overcome such limitations through the development of a unique prototype Superconducting Adaptive Gap Undulator (SC-AGU) magnet core and vacuum chamber design. This paper will outline a novel technical approach aimed at constructing a compact prototype magnet array utilizing state-of-the-art superconducting wire technology. This approach provides a more efficient magnetic structure, allowing for enhanced magnetic field strength and stability.

36 MATERIALS SCIENCE↗

The ABC130 barrel module prototyping programme for the ATLAS strip tracker

For the Phase-II Upgrade of the ATLAS Detector [1], its Inner Detector, consisting of silicon pixel, silicon strip and transition radiation sub-detectors, will be replaced with an all new 100% silicon tracker, composed of a pixel tracker at inner radii and a strip tracker at outer radii. The future ATLAS strip tracker will include 11,000 silicon sensor modules in the central region (barrel) and 7,000 modules in the forward region (end-caps), which are foreseen to be constructed over a period of 3.5 years. The construction of each module consists of a series of assembly and quality control steps, which were engineered to be identical for all production sites. In order to develop the tooling and procedures for assembly and testing of these modules, two series of major prototyping programs were conducted: an early program using readout chips designed using a 250 nm fabrication process (ABCN-250) [2,2] and a subsequent program using a follow-up chip set made using 130 nm processing (ABC130 and HCC130 chips). This second generation of readout chips was used for an extensive prototyping program that produced around 100 barrel-type modules and contributed significantly to the development of the final module layout. This paper gives an overview of the components used in ABC130 barrel modules, their assembly procedure and findings resulting from their tests.

47 OTHER INSTRUMENTATION↗

The DAQ system of the 12,000 channel CMS high granularity calorimeter prototype

The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endcap calorimeters with a high granularity sampling calorimeter equipped with silicon sensors, designed to manage the high collision rates. As part of the development of this calorimeter, a series of beam tests have been conducted with different sampling configurations using prototype segmented silicon detectors. In the most recent of these tests, conducted in late 2018 at the CERN SPS, the performance of a prototype calorimeter equipped with ≈12,000 channels of silicon sensors was studied with beams of high-energy electrons, pions and muons. This paper describes the custom-built scalable data acquisition system that was built with readily available FPGA mezzanines and low-cost Raspberry Pi computers.

47 OTHER INSTRUMENTATION↗

Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20–300 GeV positrons

The Compact Muon Solenoid collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1.1 cm$^{2}$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam test performance of a prototype module with Short Strip ASICs for the CMS HL-LHC tracker upgrade

The Short Strip ASIC (SSA) is one of the four front-end chips designed for the upgrade of the CMS Outer Tracker for the High Luminosity LHC. Together with the Macro-Pixel ASIC (MPA) it will instrument modules containing a strip and a macro-pixel sensor stacked on top of each other. The SSA provides both full readout of the strip hit information when triggered, and, together with the MPA, correlated clusters called stubs from the two sensors for use by the CMS Level-1 (L1) trigger system. Results from the first prototype module consisting of a sensor and two SSA chips are presented. The prototype module has been characterized at the Fermilab Test Beam Facility using a 120 GeV proton beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System design and prototyping for the CMS Level-1 Trigger at the High-Luminosity LHC

For the High-Luminosity Large Hadron Collider, the trigger and data acquisition system of the CMS experiment will be entirely replaced. Novel design choices have been explored, including ATCA prototyping platforms with SoC controllers and newly available interconnect technologies with serial optical links with data rates up to 28 Gb/s. Trigger analyses will be performed through sophisticated algorithms, including widespread use of Machine Learning, in large FPGAs, such as the Xilinx Ultrascale family. The system will process over 50 Tb/s of detector data with an event rate of 750 kHz. Here, we describe system design and prototyping and review trigger algorithm exemplars.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prototype acoustic positioning system for the Pacific Ocean Neutrino Experiment

We present the design and initial performance characterization of the prototype acoustic positioning system intended for the Pacific Ocean Neutrino Experiment. It comprises novel piezo-acoustic receivers with dedicated filtering- and amplification electronics installed in P-ONE instruments and is complemented by a commercial system comprised of cabled and autonomous acoustic pingers for sub-sea installation manufactured by Sonardyne Ltd. We performed an in-depth characterization of the acoustic receiver electronics and their acoustic sensitivity when integrated into P-ONE pressure housings. These show absolute sensitivities of up to -125 dB re V2/μPa2 in a frequency range of 10–40 kHz. We furthermore conducted a positioning measurement campaign in the ocean by deploying three autonomous acoustic pingers on the seafloor, as well as a cabled acoustic interrogator and a P-ONE prototype module deployed from a ship. Using a simple peak-finding detection algorithm, we observe high accuracy in the tracking of relative ranging times at approximately 230–280 μs at distances of up to 1600 m, which is sufficient for positioning detectors in a cubic-kilometer detector and which can be further improved with more involved detection algorithms. The tracking accuracy is further confirmed by independent ranging of the Sonardyne system and closely follows the ship's drift in the wind measured by GPS. The absolute positioning shows the same tracking accuracy with its absolute precision only limited by the large uncertainties of the deployed pinger positions on the seafloor.

Data analysis↗

High-gradient performance of a prototype accelerator cavity for a 3 GeV proton radiography booster

This paper reports the design, fabrication, and results of the high-gradient conditioning and testing for a two-cell, π -mode, standing wave normal-conducting prototype booster cavity for the proposed 3 GeV proton linac upgrade at Los Alamos Neutron Science Center. Increasing the energy of proton beam from the existing 800 MeV to 3 GeV will improve resolution of the proton radiography by up to 10 times. The proposed energy boost can be achieved with a compact normal-conducting high-gradient radio-frequency (rf) linac section. The C-band section of the booster linac was designed with optimized-shaped copper accelerator cavities with distributed rf coupling. A short two-cell test prototype structure was designed for the frequency of 5.712 GHz, fabricated, and tested at the C-band Engineering Research Test Facility in New Mexico (CERF-NM) at Los Alamos National Laboratory. The maximum klystron power coupled into the test structure was 8.3 MW with 1 μ s pulse length and 100 Hz repetition rate. The breakdown probabilities were recorded as functions of the accelerating gradient and peak surface fields. Operation of the test cavity at accelerating gradients of up to 100 MV / m was demonstrated. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗