Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “propane”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Emissions measurements for a lean premixed propane/air system at pressures up to 30 atmospheres

A series of experiments was conducted in which the emissions of a lean premixed system of propane and air were measured at pressures of 5, 10, 20 and 30 atm in a flametube apparatus. Measurements were made for inlet temperatures between 600K and 1000K and combustor residence times from 1.0 to 3.0 msec. A schematic of the test rig is presented along with graphs showing emissions measurements for nitric oxide, carbon monoxide, and UHC as functions of bustor residence time for various equivalence ratios, entrance temperatures and pressures; typical behavior of emissions as a function of equivalence ratio for a fixed residence time. Correlations of nitric oxide emission index with adiabatic flame temperature for a fixed residence time of 2 msec and pressures from 5 to 30 atm; and adiabatic flame temperature corresponding to CO breakpoint conditions for 2 msec residence time as a function of inlet temperature.

Roffe, G.↗

Effects of flameholder geometry on emissions and performance of lean premixed combustors

Emission levels and performance of twelve flameholder designs were investigated in a lean, premixed propane-air system at inlet conditions of 800K and 10 atm. The flameholder tested represents six design concepts with two values of blockage for each concept. The design concept consists of the following geometries: perforated plate, wire grid, single cone, multiple cone, vee gutter and swirl cone. Measurements were made at reference velocities of 35 m/s, 25 m/s and 20 m/s at combustor stations 10 cm and 30 cm downstream of the flameholder.

Venkataramani, K. S.↗

Effect of swirl on premixed combustion

Combustion in a premixed swirl combustor composed of confined concentric jets (5 cm and 10 cm diameter) were studied. The inner flow is fuel and air; the outer flow is air. Both flows may contain swirl either in the same or opposite directions. The combustor operates at one atmosphere without preheat; methane and propane were used as fuels. Related analyses and experiments were also performed for water flows and isotherm air flows. In these studies, a number of important concepts regarding premixing/prevaporized, swirl stabilized combustion were developed. Some of the more significant are discussed.

Gouldin, F. C.↗

Correlations of catalytic combustor performance parameters

A 12-cm-diameter catalytic combustor test rig using propane fuel at an inlet temperature of 800 K, a pressure of 300,000 Pa, and reference velocities from 10 to 20 m/s was studied. Combustion efficiency at the test conditions is a function of the catalyst bed cell density, cell circumference, reactor length, and the reference velocity; the efficiency was also dependent on the adiabatic reaction temperature to the tenth power. The percentage pressure drop is proportional to the reference velocity to the 1.5 power and is also proportional to the reactor length and inversely proportional to the cell hydraulic diameter, fractional open area, and the pressure. The minimum adiabatic reaction temperature required to meet the emissions goals is proportional to the reference velocity to the 0.1 power and inversely proportional to the cell circumference, cell density, and reactor length to the 0.1 power. The parameters which are a function of a catalyst factor are reported.

Bulzan, D. L.↗

Experimental study of the effects of flameholder geometry on emissions and performance of lean premixed combustors

Emissions of NOx, CO and unburned hydrocarbons (UHC) are reported for a lean premixed propane-air system at inlet conditions of 800K and 1 MPa using twelve flameholder designs. The flameholders tested represent six design concepts with two values of blockage for each concept. Data were obtained at reference velocities of 35 m/s, 25 m/s and 20 m/s at combustor stations 10 cm and 30 cm downstream of the flameholders. Flameholder pressure drop was found to be a principal determinant of emissions performance. Designs producing larger pressure drops also produced less NOx, CO and UHC emissions. The lean stability limit equivalence ratio was found to be approximately 0.35 for all designs. Flashback velocities (axial components in the flameholder passages) varied between 30 m/s and 40 m/s. A perforated plate flameholder was operated with a velocity as low as 23 m/s through the perforations at equivalence ratio 0.7 without producing flashback.

Roffe, G.↗

Investigations of coherent anti-Stokes Raman spectroscopy /CARS/ for combustion diagnostics

Investigations of coherent anti-Stokes Raman spectroscopy (CARS) in a variety of flames are presented. Thermometry has received the primary emphasis in these studies, but species spectral and sensitivity studies will also be described. CARS is generated by mixing a 10 pps, frequency-doubled neodymium 'pump' laser with a spectrally broadband, laser-pumped, Stokes-shifted dye laser. This approach obviates the requirement to frequency scan the dye laser and generates the entire CARS spectrum with each pulse permitting, in principle, instantaneous measurements of medium properties. CARS spectra of N2, CO, O2, H2O, CO2 and CH4 in flames will be presented. In general these spectra exhibit very good agreement with computer synthesized spectra and permit measurements of temperature and species concentration. To illustrate the applicability of CARS to practical combustion diagnostics, CARS signatures from N2 have been employed to map the temperature field throughout a small, luminous, highly sooting propane diffusion flame

Eckbreth, A. C.↗

The application of a drift multiwire proportional counter to the imaging of low energy X-rays

A 75 mm x 75 mm multiwire proportional counter (MWPC) with a 1 micron polypropylene window has been built to map low energy X-rays. The MWPC is constructed with a large drift region which allows us to use the center-of-gravity technique to improve the counter's efficiency and position resolution. Using 330 torr of propane as the gas fill and an anode plane composed of 20 micron diameter Au-plated tungsten wire spaced 1 mm apart, a position resolution of better than 240 microns (FWHM) in two orthogonal directions at an X-ray energy of 0.94 keV has been achieved.

Ku, W. H.-M.↗

A drift multiwire proportional counter for cosmic soft X-ray imaging

Multiwire proportional counters with 1 micrometer polypropylene windows, of dimensions 75 mm x 75 mm and 100 mm x 100 mm, have been built to map soft cosmic X-rays. The counters are constructed with a large drift region which makes it possible to use the center-of-gravity technique to improve the counter's efficiency and position resolution. Using 330 torr of propane as the gas fill and an anode plane composed of 20 micrometer diameter, gold-plated tungsten wire spaced 1mm apart, a position resolution of better than 280 micrometers (FWHM) in two orthogonal directions at an X-ray energy of 0.94 keV was achieved.

Reid, P. B.↗

Cryogenic wind tunnel activities at the University of Southampton

The characteristics and behavior of a 0.3m transonic cryogenic wind tunnel are discussed. The wide band of usable Reynolds numbers is analyzed along with a flow visualization technique using propane. The combination of magnetic suspension with the cryogenic wind tunnel is described. An outline of the circuit showing the locations of the magnet system and the features of the tunnel are presented.

Goodyer, M. J.↗

Premixing quality and flame stability: A theoretical and experimental study

Models for predicting flame ignition and blowout in a combustor primary zone are presented. A correlation for the blowoff velocity of premixed turbulent flames is developed using the basic quantities of turbulent flow, and the laminar flame speed. A statistical model employing a Monte Carlo calculation procedure is developed to account for nonuniformities in a combustor primary zone. An overall kinetic rate equation is used to describe the fuel oxidation process. The model is used to predict the lean ignition and blow out limits of premixed turbulent flames; the effects of mixture nonuniformity on the lean ignition limit are explored using an assumed distribution of fuel-air ratios. Data on the effects of variations in inlet temperature, reference velocity and mixture uniformity on the lean ignition and blowout limits of gaseous propane-air flames are presented.

Radhakrishnan, K.↗

Experimental studies of the formation/deposition of sodium sulfate in/from combustion gases

An optical polarization (ellipsometric) technique was developed for measuring rapidly growing and evaporating transparent liquid condensate films (e.g., boric oxide) on solid surfaces exposed to combustion product gases. Results for the B2O3 deposition rate from BCl3-seeded propane/air flames are shown to agree well with the results of earlier interference measurements, and also with theoretical CVD predictions. Evaporation rates (from platinum ribbons into seeded propane air flames) are estimated using the polarization technique. It appears that, compared with the interference method, the polarization technique places less stringent requirements on surface quality, which may justify the added optical components needed for such measurements. It is concluded that the complementary optical methods of polarization (ellipsometry) and interference hold considerable promise for application to the rapid measurement of condensation and evaporation rates in high temperature (e.g., combustion product) environments.

Rosner, D. E.↗

Data reduction and analysis of graphite fiber release experiments

The burn and burn/explode effects on aircraft structures were examined in a series of fifteen outdoor tests conducted to verify the results obtained in previous burn and explode tests of carbon/graphite composite samples conducted in a closed chamber, and to simulate aircraft accident scenarios in which carbon/graphite fibers would be released. The primary effects that were to be investigaged in these tests were the amount and size distribution of the conductive fibers released from the composite structures, and how these various sizes of fibers transported downwind. The structures included plates, barrels, aircraft spoilers and a cockpit. The heat sources included a propane gas burner and 20 ft by 20 ft and 40 ft by 60 ft JP-5 pool fires. The larger pool fire was selected to simulate an aircraft accident incident. The passive instrumentation included sticky paper and sticky bridal veil over an area 6000 ft downwind and 3000 ft crosswind. The active instrumentation included instrumented meteorological towers, movies, infrared imaging cameras, LADAR, high voltage ball gages, light emitting diode gages, microwave gages and flame velocimeter.

Lieberman, P.↗

Evaluation of a locally homogeneous flow model of spray combustion

A model of spray combustion which employs a second-order turbulence model was developed. The assumption of locally homogeneous flow is made, implying infinitely fast transport rates between the phase. Measurements to test the model were completed for a gaseous n-propane flame and an air atomized n-pentane spray flame, burning in stagnant air at atmospheric pressure. Profiles of mean velocity and temperature, as well as velocity fluctuations and Reynolds stress, were measured in the flames. The predictions for the gas flame were in excellent agreement with the measurements. The predictions for the spray were qualitatively correct, but effects of finite rate interphase transport were evident, resulting in a overstimation of the rate development of the flow. Predictions of spray penetration length at high pressures, including supercritical combustion conditions, were also completed for comparison with earlier measurements. Test conditions involved a pressure atomized n-pentane spray, burning in stagnant air at pressures of 3, 5, and 9 MPa. The comparison between predictions and measurements was fair. This is not a very sensitive test of the model, however, and further high pressure experimental and theoretical results are needed before a satisfactory assessment of the locally homogeneous flow approximation can be made.

Mao, C. P.↗

Evaluation of micron size carbon fibers released from burning graphite composites

Quantitative estimates were developed of micron carbon fibers released during the burning of graphite composites. Evidence was found of fibrillated particles which were the predominant source of the micron fiber data obtained from large pool fire tests. The fibrillation phenomena were attributed to fiber oxidation effects caused by the fire environment. Analysis of propane burn test records indicated that wind sources can cause considerable carbon fiber oxidation. Criteria estimates were determined for the number of micron carbon fibers released during an aircraft accident. An extreme case analysis indicated that the upper limit of the micron carbon fiber concentration level was only about half the permissible asbestos ceiling concentration level.

Sussholz, B.↗

Flame tube parametric studies for control of fuel bound nitrogen using rich-lean two-stage combustion

An experimental parametric study of rich-lean two-stage combustion in a flame tube is described and approaches for minimizing the conversion of fuel-bound nitrogen to nitrogen oxides in a premixed, homogeneous combustion system are evaluated. Air at 672 K and 0.48 MPa was premixed with fuel blends of propane, toluene, and pyridine at primary equivalence ratios ranging from 0.5 to 2.0 and secondary equivalence ratios of 0.5 to 0.7. Distillates of SRC-II, a coal syncrude, were also tested. The blended fuels were proportioned to vary fuel hydrogen composition from 9.0 to 18.3 weight percent and fuel nitrogen composition from zero to 1.5 weight percent. Rich-lean combustion proved effective in reducing fuel nitrogen to NO sub x conversion; conversion rates up to 10 times lower than those normally produced by single-stage combustion were achieved. The optimum primary equivalence ratio, where the least NO sub x was produced and combustion efficiency was acceptable, shifted between 1.4 and 1.7 with changes in fuel nitrogen content and fuel hydrogen content. Increasing levels of fuel nitrogen content lowered the conversion rate, but not enough to avoid higher NO sub x emissions as fuel nitrogen increased.

Schultz, D. F.↗

Noble gas trapping and fractionation during synthesis of carbonaceous matter

An investigation of noble gas entrapment during synthesis of carbonaceous, macromolecular, and kerogen-like substances is presented. High molecular weight organic matter synthesized in aqueous condensation reactions contained little gas, and the composition was consistent with fractionation due to noble gas solubility in water; however, propane soot produced during a modified Miller-Urey experiment in an aritificial gas mixture contained high concentrations of trapped noble gases that displayed strong elemental fractionation from their reservoirs. It is concluded that theses experiemnts show that processes exist for synthesis of carbonaceous carriers that result in high noble gas concentrations and strong elemental fractionation at temperatures well above those required by absorption to achieve similar effects.

Frick, U.↗

Evaluation of a locally homogeneous flow model of spray combustion

A simplified model of spray combustion was evaluated. The model was compared with measurements in both a gaseous propane flame and an air atomized n-pentane spray flame (35 micron Sauter mean diameter). Profiles of mean velocity, temperature, and species concentrations, as well as velocity fluctuations and Reynolds stress, were measured. The predictions for the gas flame were in excellent agreement with measurements, except for product species concentrations where errors due to finite reaction rates were detected. Predictions within the spray were qualitatively correct, but the model overestimated the rate of development of the flow; e.g., predicted flame lengths were 30% shorter than measured. Calibrated drop-life-history calculations showed that finite interphase transport rates caused the discrepancy and that initial drop diameters less than 20 microns would be required for quantitative accuracy of the model.

Mao, C.-P.↗

Advanced cooling techniques for high-pressure, hydrocarbon-fueled rocket engines

The regenerative cooling limits (maximum chamber pressure) are defined for oxygen/hydrocarbon (Methane, Propane, and RP-1) rocket engines over a thrust range of 20,000 to 600,000 lbf for a reusable life of 250 missions. Chamber pressure limits are first defined without a hot-gas wall carbon layer (unenhanced designs). Cooling enhancement chamber pressure limits are then established for seven thermal barriers (carbon layer, ceramic coating, graphite liner, film cooling, zoned combustion, transpiration cooling, and a combination of two of the above). The maximum regenerative-cooled chamber pressure is attained with the oxygen/methane propellant combination.

Cook, R. T.↗