Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system parameter estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A Robust State Estimation Framework Considering Measurement Correlations and Imperfect Synchronization

This paper develops a robust power system state estimation framework with the consideration of measurement correlations and imperfect synchronization. In the framework, correlations of SCADA and PMU measurements are calculated separately through unscented transformation and a vector autoregression (VAR) model. In particular, PMU measurements during the waiting period of two SCADA measurement scans are buffered to develop the VAR model. The latter takes into account the temporal and spatial correlations of PMU measurements and provides redundant measurements to suppress bad data and mitigate imperfect synchronization. In case of synchronization issues between SCADA and PMU measurements, either forecasted PMU measurements or prior SCADA measurements from the last estimation run are leveraged to restore system observability. After that, robust generalized maximum-likelihood (GM)-estimator is developed to integrate full measurement correlations and handle bad data in SCADA and PMU measurements. Thanks to the robustness and flexibility of the proposed robust estimator, bad data as well as imperfect measurement synchronization are mitigated, yielding high statistical efficiency. Comprehensive comparison results with other alternatives under various conditions demonstrate the benefits of the proposed framework.

Zhao, Junbo (ORCID:0000000284989666)↗

Fault diagnosis and severity estimation in nuclear power plants - 196

Signed Directed Graph (SDG) is a type of fault diagnosis method with a capability to display the complex relationship between plant parameters and reveal the potential danger and the propagation path when a fault occurs in a nuclear plant. However, the fault diagnosis method based on qualitative SDG model inevitably has a number of disadvantages, and some of these disadvantages include its inability to identify reoccurring faults; ambiguous reasoning that can result in low resolution; performance that relies on the accuracy of the model; slow diagnosis rate for large systems and poor real-time diagnosis, among others. In this paper, we propose an SDG fault diagnosis methodology based on Granular Computing Theory, referred to as Granular Computing Signed Directed Graph (GCSDG). This paper shows how knowledge reduction nature of granular computing based fault diagnosis can simplify the decision table, reduce the allocation of resources, scale-down the complexity of the problem and improve the efficiency of data processing. Then, we estimate the severity of the fault using Back Propagation (BP) neural network approach. The proposed methodology was verified by considering certain faults in the primary loop of a PWR, using PCTRAN. The result shows a considerable improvement in fault diagnosis and the severity estimated serves as a useful information for the operator, providing a firm foundation for further intervention. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improving Distribution Resiliency with Microgrids and State and Parameter Estimation

Modern society relies on low-cost reliable electrical power, both to maintain industry, as well as provide basic social services to the populace. When major disturbances occur, such as Hurricane Katrina or Hurricane Sandy, the nation’s electrical infrastructure can experience significant outages. To help prevent the spread of these outages, as well as facilitating faster restoration after an outage, various aspects of improving the resiliency of the power system are needed. Two such approaches are breaking the system into smaller microgrid sections, and to have improved insight into the operations to detect failures or mis-operations before they become critical. Breaking the system into smaller sections of microgrid islands, power can be maintained in smaller areas where distribution generation and energy storage resources are still available, but bulk power generation is no longer connected. Additionally, microgrid systems can maintain service to local pockets of customers when there has been extensive damage to the local distribution system. However, microgrids are grid connected a majority of the time and implementing and operating a microgrid is much different than when islanded. This report discusses work conducted by the Pacific Northwest National Laboratory that developed improvements for simulation tools to capture the characteristics of microgrids and how they can be used to develop new operational strategies. These operational strategies reduce the cost of microgrid operation and increase the reliability and resilience of the nation’s electricity infrastructure. In addition to the ability to break the system into microgrids, improved observability into the state of the distribution grid can make the power system more resilient. State estimation on the transmission system already provides great insight into grid operations and detecting abnormal conditions by leveraging existing measurements. These transmission-level approaches are expanded to using advanced metering infrastructure and other distribution-level measurements to create a three-phase, unbalanced distribution state estimation approach. With distribution-level state estimation, the grid can be operated more efficiently, and outages or equipment failures can be caught faster, improving the overall resilience and reliability of the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Projections of Full-Fuel-Cycle Energy and Emissions Metrics

To accurately represent how conservation and efficiency policies affect energy demand, both direct and indirect impacts need to be included in the accounting. The indirect impacts are defined here as the resource savings that accrue over the fuel production chain, which when added to the energy consumed at the point of use, constitute the full-fuel- cycle (FFC) energy. This paper uses the accounting framework developed in (Coughlin 2012) to calculate FFC energy metrics as time series for the period 2010-2040. The approach is extended to define FFC metrics for the emissions of greenhouse gases (GHGs) and other air-borne pollutants. The primary focus is the types of energy used in buildings and industrial processes, mainly natural gas and electricity. The analysis includes a discussion of the fuel production chain for coal, which is used extensively for electric power generation, and for diesel and fuel oil, which are used in mining, oil and gas operations, and fuel distribution. Estimates of the energy intensity parameters make use of data and projections from the Energy Information Agency’s National Energy Modeling System, with calculations based on information from the Annual Energy Outlook 2012.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Carbon Dioxide Enhanced Oil Recovery Life Cycle (CELiC) Model

The Carbon Dioxide (CO 2 ) Enhanced Oil Recovery (EOR) Life Cycle (CELiC) Model calculates life cycle greenhouse gas (GHG) emissions for a CO 2 -EOR system, where the user can select one of three sources of the injected CO 2 : (1) extracted from a natural dome, (2) captured from a coal-fired power plant, or (3) captured from a natural gas power plant. The model has several parameters and options to allow the assessment of the system for a wide-array of products—electricity, pipeline CO 2 , crude oil, and refined fuels. The model is also capable of deterministic (i.e., point estimate) and stochastic (i.e., probabilistic) analyses and finally a deterministic time-series analysis that shows the changing GHG emissions for the CO 2 -EOR system over time.

03 NATURAL GAS↗

Solar Power System Evaluated for the Human Exploration of Mars

The electric power system is a crucial element of any mission for the human exploration of the Martian surface. The bulk of the power generated will be delivered to crew life support systems, extravehicular activity suits, robotic vehicles, and predeployed in situ resource utilization (ISRU) equipment. In one mission scenario, before the crew departs for Mars, the ISRU plant operates for 435 days producing liquefied methane and oxygen for ascent-stage propellants and water for crew life support. About 200 days after ISRU production is completed, the crew arrives for a 500-day surface stay. In this scenario, the power system must operate for a total of 1130 days (equivalent to 1100 Martian "sols"), providing 400 MW-hr of energy to the ISRU plant and up to 18 kW of daytime user power. A photovoltaic power-generation system with regenerative fuel cell (RFC) energy storage has been under study at the NASA Glenn Research Center at Lewis Field. The conceptual power system is dominated by the 4000- m2 class photovoltaic array that is deployed orthogonally as four tent structures, each approximately 5 m on a side and 100-m long. The structures are composed of composite members deployed by an articulating mast, an inflatable boom, or rover vehicles, and are subsequently anchored to the ground. Array panels consist of thin polymer membranes with thin-film solar cells. The array is divided into eight independent electrical sections with solar cell strings operating at 600 V. Energy storage is provided by regenerative fuel cells based on hydrogen-oxygen proton exchange membrane technology. Hydrogen and oxygen reactants are stored in gaseous form at 3000 psi, and the water produced is stored at 14.7 psi. The fuel cell operating temperature is maintained by a 40-m2 deployable pumped-fluid loop radiator that uses water as the working fluid. The power management and distribution (PMAD) architecture features eight independent, regulated 600-Vdc channels. Power management and distribution power cables use various gauges of copper conductors with ethylene tetrafluoroethylene insulation. To assess power system design options and sizing, we developed a dedicated Fortran code to predict detailed power system performance and estimate system mass. This code also modeled the requisite Mars surface environments: solar insolation, Sun angles, dust storms, dust deposition, and thermal and ultraviolet radiation. Using this code, trade studies were performed to assess performance and mass sensitivities to power system design parameters (photovoltaic array geometry and orientation) and mission parameters (landing date and landing site latitude, terrain slope, and dust storm activity). Mission analysis cases were also run. Power results are shown in this graph for an analysis case with a September 1, 2012, landing date; 18.95 North latitude landing site; two seasonal dusts storms; and tent arrays. To meet user load requirements and the ISRU energy requirement, an 8-metric ton (MT) power system and 4000-m2 photovoltaic array area were required for the assumed advanced CuInS2 thin-film solar cell technology. In this figure, the top curve is the average daytime photovoltaic array power, the middle curve is average daytime user load power, and the bottom curve is nighttime power. At mission day 1, daytime user power exceeds 120 kW before falling off to 80 kW at the end of the mission. Throughout the mission, nighttime user power is set to the nighttime power requirement. In this analysis, "nighttime" is defined as the 13- to 15-hr period when array power output is below the daytime power requirement. During dust storms, power system capability falls off dramatically so that by mission day 900, a daily energy balance cannot be maintained. Under these conditions, the ISRU plant is placed in standby mode, and the regenerative fuel cell energy storage is gradually discharged to meet user loads.

Kerslake, Thomas W.↗

Deep SOAR follow-up photometry of two Milky Way outer-halo companions discovered with Dark Energy Survey

We report the discovery of a new star cluster, DES 3, in the constellation of Indus, and deeper observations of the previously identified satellite DES J0222.7−5217 (Eridanus III). DES 3 was detected as a stellar overdensity in first-year Dark Energy Survey data, and confirmed with deeper photometry from the 4.1-m Southern Astrophysical Research (SOAR) telescope. The new system was detected with a relatively high significance and appears in the DES images as a compact concentration of faint blue point sources. We determine that DES 3 is located at a heliocentric distance of ≃76.2 kpc and it is dominated by an old (≃9.8 Gyr) and metal-poor ([Fe/H] ≃ −1.84) population. While the age and metallicity values of DES 3 are comparable to typical globular clusters (objects with a high stellar density, stellar mass of ∼10^5 M_⊙ and luminosity ∼ −7.3), its half-light radius (r_h ∼ 6.87 pc) and luminosity (M_V ∼ −1.7) are more indicative of faint star cluster. Based on the angular size, DES 3, with a value of r_h ∼ 0$${^{\prime}_{.}}$$31, is among the smallest faint star clusters known to date. Furthermore, using deeper imaging of DES J0222.7−5217 taken with the SOAR telescope, we update structural parameters and perform the first isochrone modelling. Our analysis yields the first age (≃12.6 Gyr) and metallicity ([Fe/H] ≃ −2.01) estimates for this object. The half-light radius (r_h ≃ 11.24 pc) and luminosity (M_V ≃ −2.4) of DES J0222.7−5217 suggest that it is likely a faint star cluster. The discovery of DES 3 indicates that the census of stellar systems in the Milky Way is still far from complete, and demonstrates the power of modern wide-field imaging surveys to improve our knowledge of the Galaxy’s satellite population.

79 ASTRONOMY AND ASTROPHYSICS↗

Artificial Neural Network-Based Monitoring of the Fuel Assembly Temperature Sensor and FPGA Implementation

Numerous methods have been developed around the world to model the dynamic behavior and detect a faulty operating mode of a temperature sensor. In this context, we present in this study a new method based on the dependence between the fuel assembly temperature profile on control rods positions, and the coolant flow rate in a nuclear reactor. This seems to be possible since the insertion of control rods at different axial positions and variations in flow rate of the reactor coolant results in different produced thermal power in the reactor. This is closely linked to the instant fuel rod temperature profile. In a first step, we selected parameters to be used and confirmed the adequate correlation between the chosen parameters and those to be estimated by the proposed monitoring system. In the next step, we acquired and de-noised the data of corresponding parameters, the qualified data is then used to design and train the artificial neural network. The effective data denoising was done by using the wavelet transform to remove a various kind of artifacts such as inherent noise. With the suitable choice of wavelet level and smoothing method, it was possible for us to remove all the non-required artifacts with a view to verify and analyze the considered signal. In our work, several potential mother wavelet functions (Haar, Daubechies, Bi-orthogonal, Reverse Bi-orthogonal, Discrete Meyer and Symlets) were investigated to find the most similar function with the being processed signals. To implement the proposed monitoring system for the fuel rod temperature sensor (03 wire RTD sensor), we used the Bayesian artificial neural network 'BNN' technique to model the dynamic behavior of the considered sensor, the system correlate the estimated values with the measured for the concretization of the proposed system we propose an FPGA (field programmable gate array) implementation. The monitoring system use the correlation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An analysis of parameters affecting ampacity in aircraft bipolar MVDC power cables via coupled electrical, thermal, and computational fluid dynamic modelling

Abstract The next generation of aircraft, including more electric aircraft and all‐electric aircraft (AEA), requires electric power systems with high power density and low system mass specifications. Increasing the voltage of the system to the range of a few kV, medium voltage (MV), is a reasonable approach to achieving high‐power‐density and low‐system‐mass EPSs for aircraft applications. Higher voltages, however, pose many challenges for aviation MV power cables such as arcs and arc tracking, partial discharges (PDs), and thermal management. In this regard, thermal management is more challenging since heat transfer by convection is greatly reduced at wide‐body aircraft's cruising altitudes due to the reduced air pressure. In this paper, a finite element method (FEM) model is developed in COMSOL Multiphysics for an aircraft bipolar MVDC (±5 kV) power cable. Using the model, the maximum permissible cable current at a low pressure of 18.8 kPa (at an altitude of 12.2 km from sea level, the usual cruising altitude for wide‐body aircraft) is calculated. Also, an analytical model is developed based on analytical and proven empirical correlations governing conductive, radiative, and convective heat transfers at the steady state to estimate the ampacity of the bipolar cable system at reduced pressure. It was shown that the proposed analytical model can be used for atmospheric pressure and systems with a larger number of poles, expanding its range of applications. The results of the FEM and analytical models correlate at wide ranges of parameters such as ambient temperature, duct size, distance between the positive and negative pole cables, and the overall diameter of the cables. The influence of horizontal and vertical arrangement of poles is included in the analytical model. The results of this study can be used to design bipolar MVDC power cable systems for the envisaged wide‐body AEA.

Azizi, Arian↗

Stability region maximization by decomposition-aggregation method

This work is to improve the estimates of the stability regions by formulating and resolving a proper maximization problem. The solution of the problem provides the best estimate of the maximal value of the structural parameter and at the same time yields the optimum comparison system, which can be used to determine the degree of stability of the Skylab. The analysis procedure is completely computerized, resulting in a flexible and powerful tool for stability considerations of large-scale linear as well as nonlinear systems.

Siljak, D. D.↗

Robot trajectory tracking with self-tuning predicted control

A controller that combines self-tuning prediction and control is proposed for robot trajectory tracking. The controller has two feedback loops: one is used to minimize the prediction error, and the other is designed to make the system output track the set point input. Because the velocity and position along the desired trajectory are given and the future output of the system is predictable, a feedforward loop can be designed for robot trajectory tracking with self-tuning predicted control (STPC). Parameters are estimated online to account for the model uncertainty and the time-varying property of the system. The authors describe the principle of STPC, analyze the system performance, and discuss the simplification of the robot dynamic equations. To demonstrate its utility and power, the controller is simulated for a Stanford arm.

Cui, Xianzhong↗

Stray RF Power Estimates From EC Exploitation During ITER Plasma Operations

The EC H and CD system of ITER tokamak is an essential tool for all the phases of ITER operation. Different levels of EC power are required through all the plasma discharge: up to 6.7 MW for assisting the breakdown and burn through, up to 20 MW for current drive and saw-teeth control from the equatorial launcher and up to 20 MW for NTM stabilization from the upper launchers. The assistance to breakdown and burn through is characterized by a very low (if not negligible) RF power absorption by the plasma. A significant level of stray radiation may also arise from partial absorption due to non-optimal plasma parameters and/or wrong injected polarization. The stray power radiated in the vacuum chamber is estimated as a first step toward mitigating potential harmful consequence to in-vessel structures and diagnostics. Power loading of the chamber walls (peek power and average power density for straight beam propagation in the empty chamber) and diffuse stray radiation effects are simulated to infer suitable strategies to avoid damage to first wall and to microwave sensitive components.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

COUPLING OF RELAP5-SCDAP MOD4.0 AND NEUTRONIC CODES

High-fidelity and accurate nuclear system codes play a key role in the design and analysis of complex nuclear power plants, which consist of multiple subsystems, such as the reactor core (and its fuel, burnable poisons, control elements, etc.), the reactor internal structures, the vessel, and the energy conversion subsystem and beyond to grid demand. Most commonly the interplay between these various subsystems is modeled using coupled codes, each of which represents one of the subsystems. And the most common direct coupling is that of thermal-hydraulics and neutronics codes. The subject of this paper is the coupling of codes that model not only thermal-hydraulics and neutronics, but also structural components damage. Furthermore, the neutronic component is not limited to the sole core solver. The coupled code system encompasses thermal-hydraulics, material performance of the fuel, neutronic solver, and neutronic data preparation. Thus, this paper presents a framework for coupling RELAP5/SCDAPSIM/MOD4.0 with a suite of neutron kinetics codes that includes NESTLE, DRAGON and a version of the ENDF library. The version of the RELAP5/SCDAPSIM/MOD4.0 code used in this work is one developed by Innovate System Software (ISS) as part of the international SCDAP Development and Training Program (SDTP) for best-estimate analysis to model reactor transients including severe accident phenomena. This RELAP5/SCDAPSIM/MOD4.0 code version is also capable of predicting nuclear fuel performance. It uses nodal power distributions to calculate mechanical and thermal parameters such as heat-up, oxidation and meltdown of fuel rods and control rods, the ballooning and rupture of fuel rod cladding, the release of fission products from fuel rods, and the disintegration of fuel rods into porous debris and molten material. On the neutronics side, this work uses the NESTLE and DRAGON codes. NESTLE is a multi-dimensional static and kinetic neutronic code developed at North Carolina State University. It solves up to four energy groups neutron diffusion equations utilizing the Nodal Expansion Method (NEM) in Cartesian or hexagonal geometry. The DRAGON code, developed at Ecole Polytechnique de Montreal, performs lattice physics calculations based on the neutron transport equation and is capable of using very fine energy group structures. In this work, we have developed a coupling approach to exchange data among the various modules. In the coupling process, the generated nuclear data (in fine multigroup energy structure) are collapsed down into two- or four-group energy structures for use in NESTLE. The neutron kinetics and thermal-hydraulics modules are coupled at each time step by using the cross-section data. The power distribution results of the neutronic calculations are transmitted to the thermal-hydraulics code. The spatial distribution of coolant density and the fuel-moderator temperature, which result from the thermal-hydraulic calculations, are transmitted back to the neutron kinetics codes and then the loop is closed using new neutronics results. Details of the actual data transfers will be described in the full length paper.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Self-Security for Grid-Interactive Smart Inverters Using Steady-State Reference Model

Smart inverters exchange information with other devices through a shared communication link, making the inverters more prone to receive harmful commands from external parties. This erroneous data can be received due to an anomaly in the system, such as a device fault, unintentional utility operator action, or a cyber-attack. In this paper, a device-level self-security strategy is implemented using reference models for a grid-interactive inverter to examine the incoming power setpoints, detect the anomalies, and protect the system accordingly. The PQ setpoints received from the utility supervisory controller are autonomously examined using the inverter’s normal and stable operating regions before engaging the setpoints to the inverter’s local controller. Grid parameters are estimated in real-time during the examination process. The efficacy of the self-security algorithm is tested using a three-phase 3-kVA SiC-MOSFET inverter and a 12-kW NHR 9410 regenerative grid emulator. The results verify that the proposed method can detect harmful PQ setpoints that can cause abnormal or unstable inverter operation.

Gursoy, Mehmetcan↗

A Compact, High-Performance Continuous Magnetic Refrigerator

We present test results of the first adiabatic demagnetization refrigerator (ADR) that can produce continuous cooling at sub-kelvin temperatures. This system uses multiple stages that operate in sequence to cascade heat from a continuous stage up to a heat sink. Continuous operation aids the usual constraints of long hold times and short recycle times that lead to the generally large mass of single-shot ADRs, and allows us to achieve much higher cooling power per unit mass. Our design goal is 10 microW of cooling at 50 mK while rejecting heat to a 6-10 K heat sink. The total cold mass is estimated to be less than 10 kg, including magnetic shielding of each stage. These parameters envelop the requirements for currently planned astronomy missions. The relatively high heat rejection capability allows it to operate with a mechanical cryocooler as part of a cryogen-free, low temperature cooling system. This has the advantages of long, mission life and reduced complexity and cost. At present, we have assembled a three-stage ADR that operates with a superfluid helium bath. Additional work is underway to develop magnetocaloric materials that can extend its heat rejection capability up to 10 K. This paper discusses the design and operation of the ADR, as well as interface requirements for cryocooler-based operation.

Shirron, Peter↗

Development of high concentration photovoltaics (HCPV) power plants in the US Southwest: Economic assessment and sensitivity analysis

High concentration photovoltaic (HCPV) technologies offer several advantages over typical PV systems. In this study, a detailed economic assessment and sensitivity analysis of deploying HCPV plants in the US southwest is performed. To do this, a 20 MWdc HCPV power plant is designed using the System Advisor Model (SAM) and is evaluated from both technical and financial aspects. The sensitivity analysis shows that reducing the installed cost per capacity of the HCPV system can significantly improve the economics and reduce the levelized cost of electricity (LCOE) and levelized power purchase agreement (LPPA). Also, providing proper incentives including both investment tax credits (ITC) and production tax credit (PTC), loan debt ratio, and interest rate are among the most influential parameters. The analysis shows that with the 30% ITC, the LCOE, and LPPA of the designed HCPV projects are between $65.4/MWh and $69.3/MWh and between $71.0/MWh and $75.2/MWh, respectively. The estimated LCOE and LPPA values are almost 50% higher than the utility-scale PV projects. If proper funding is provided to continue the support of the HCPV system, they would become more economical and competitive with PV plants. Federal and state government policies must also be established to advocate HCPV systems.

14 SOLAR ENERGY↗

Advanced Technology Lifecycle Analysis System (ATLAS)

Developing credible mass and cost estimates for space exploration and development architectures require multidisciplinary analysis based on physics calculations, and parametric estimates derived from historical systems. Within the National Aeronautics and Space Administration (NASA), concurrent engineering environment (CEE) activities integrate discipline oriented analysis tools through a computer network and accumulate the results of a multidisciplinary analysis team via a centralized database or spreadsheet Each minute of a design and analysis study within a concurrent engineering environment is expensive due the size of the team and supporting equipment The Advanced Technology Lifecycle Analysis System (ATLAS) reduces the cost of architecture analysis by capturing the knowledge of discipline experts into system oriented spreadsheet models. A framework with a user interface presents a library of system models to an architecture analyst. The analyst selects models of launchers, in-space transportation systems, and excursion vehicles, as well as space and surface infrastructure such as propellant depots, habitats, and solar power satellites. After assembling the architecture from the selected models, the analyst can create a campaign comprised of missions spanning several years. The ATLAS controller passes analyst specified parameters to the models and data among the models. An integrator workbook calls a history based parametric analysis cost model to determine the costs. Also, the integrator estimates the flight rates, launched masses, and architecture benefits over the years of the campaign. An accumulator workbook presents the analytical results in a series of bar graphs. In no way does ATLAS compete with a CEE; instead, ATLAS complements a CEE by ensuring that the time of the experts is well spent Using ATLAS, an architecture analyst can perform technology sensitivity analysis, study many scenarios, and see the impact of design decisions. When the analyst is satisfied with the system configurations, technology portfolios, and deployment strategies, he or she can present the concepts to a team, which will conduct a detailed, discipline-oriented analysis within a CEE. An analog to this approach is the music industry where a songwriter creates the lyrics and music before entering a recording studio.

O'Neil, Daniel A.↗

Melting temperatures of the ZrO{sub 2}-MOX system

Severe accidents occurred at the Fukushima Daiichi Nuclear Power Plant Units 1-3 on March 11, 2011. MOX fuels were loaded in the Unit 3. For the thermal analysis of the severe accident, melting temperature and phase state of MOX corium were investigated. The simulated coriums were prepared from 4%Pu-containing MOX, 8%Pu-containing MOX and ZrO{sub 2}. Then X-ray diffraction, density and melting temperature measurements were carried out as a function of zirconium and plutonium contents. The cubic phase was observed in the 25%Zr-containing corium and the tetragonal phase was observed in the 50% and 75%Zr-containing coria. The lattice parameter and density monotonically changed with Pu content. Melting temperature increased with increasing Pu content; melting temperature were estimated to be 2932 K for 4%Pu MOX corium and 3012 K for 8%Pu MOX corium in the 25%ZrO{sub 2}-MOX system. The lowest melting temperature was observed for 50%Zr-containing corium. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗