Comparison of Thermal Management Approaches for Integrated Traction Drives in Electric Vehicles

The continuous push to increase power densities of electric vehicle (EV) traction drive systems necessitates combining electric motor and power electronics into one unit. A single, compact traction drive unit with fewer interconnecting components also facilitates fast, automated assembly of electric vehicles, driving production costs down and enabling wider adoption of EVs. There are a number of challenges associated with the integration of power electronics with the electric machine, including thermal management of the combined traction drive system. However, one important benefit of integration from the thermal management system perspective is the potential for using a single fluid loop instead of two separate cooling systems for the electric machine and the power electronics/inverter. This paper reviews several integration approaches and, employing finite element analysis (FEA), compares thermal management solutions for the combined electric machine and power electronics systems. Namely, three different scenarios are modeled: (1) independent component (motor and power electronics) cooling, which is compared to the combined cooling system approach for (2) radially and (3) axially integrated power electronics modules into the motor enclosure. Temperature distributions for selected thermal loads and thermal resistances from the key heat-generating components to the cooling fluid are compared for each scenario.

47 OTHER INSTRUMENTATION↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Data-Driven Exploration of the Impact of Renewable Energy on Inter-Area Oscillations in the U.S. Eastern Interconnection

As increasing amounts of renewable energy (RE) resources are incorporated into the bulk-power grid, power system oscillations are expected to change. This work investigates how RE generation impacts the frequency and damping ratio (DR) of two dominant inter-area modes in the U.S. Eastern Interconnection (EI) using regularly updated estimates collected over a 12-month period. Quantile regression is used to derive the correlation between operating conditions and mode properties, and a bootstrap method is used to quantify the uncertainty associated with the correlation estimates. Results show that with an increase in system load, the frequency of a mode decreases and DR increases. Evidence that increasing RE generation results in an increase in frequency and decline in DR was found for one of the two modes studied. This work shows that increasing RE levels will impact the properties of inter-area oscillations in the EI, but it does not indicate the presence of immediate threats to grid stability. The outlined approach can be used to periodically assess changing mode properties as RE levels continue to grow and flag stability concerns before they become serious reliability threats.

Inter-area oscillation, mode meters, quantile regr↗

Describing Function Analysis of Transformer Magnetizing Inductance for Direct Power Control of Back-to-Back Modular Multilevel Converters with Advanced Grid Support

This paper provides a detailed investigation into the application of describing function-based analysis for assessing transformer magnetizing inductance and its impact on system performance. The focus is on a back-to-back modular multilevel converter architecture, designed to interconnect systems operating at different frequencies. The study explores the implementation of a Direct Power Control strategy, examining its effects on transformer magnetizing inductance saturation and offering effective mitigation techniques. Furthermore, the integration of advanced grid support functionalities is highlighted, demonstrating how these enhancements bolster the converter's ability to improve grid stability and power quality, positioning it as a robust solution for modern power systems. The proposed approach is validated through extensive computer simulations based MAT LAB/Simulink domain, supported by significant case study results, confirming its practical effectiveness.

back-to-back modular multilevel converters (B2B- M↗

Stakeholder Training for IEEE 1547-2018 (Abbreviated Final Technical Report)

This project identifies and makes publicly available educational materials to assist stakeholders in adopting the revised IEEE Std 1547-2018, Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces. The new standard is significantly different than the previous 2003 version, contains new concepts and new technical requirements, and requires educational material on the application of these changes. NREL had a principal role in accelerating the revision process though its chairmanship of the IEEE Std 1547 working group to revise the standard and through technical support provided to the working group. Under this project, NREL and partners compiled and developed publicly available educational materials for IEEE Std 1547-2018, including webinars, white papers, and other resources on related topics.

14 SOLAR ENERGY↗

Spaceborne Processor Array

A Spaceborne Processor Array in Multifunctional Structure (SPAMS) can lower the total mass of the electronic and structural overhead of spacecraft, resulting in reduced launch costs, while increasing the science return through dynamic onboard computing. SPAMS integrates the multifunctional structure (MFS) and the Gilgamesh Memory, Intelligence, and Network Device (MIND) multi-core in-memory computer architecture into a single-system super-architecture. This transforms every inch of a spacecraft into a sharable, interconnected, smart computing element to increase computing performance while simultaneously reducing mass. The MIND in-memory architecture provides a foundation for high-performance, low-power, and fault-tolerant computing. The MIND chip has an internal structure that includes memory, processing, and communication functionality. The Gilgamesh is a scalable system comprising multiple MIND chips interconnected to operate as a single, tightly coupled, parallel computer. The array of MIND components shares a global, virtual name space for program variables and tasks that are allocated at run time to the distributed physical memory and processing resources. Individual processor- memory nodes can be activated or powered down at run time to provide active power management and to configure around faults. A SPAMS system is comprised of a distributed Gilgamesh array built into MFS, interfaces into instrument and communication subsystems, a mass storage interface, and a radiation-hardened flight computer.

Chow, Edward T.↗

Managing Solar Photovoltaic Integration in the Western United States Appendix: Reference and High Solar Photovoltaic Scenarios for Three Regions [Slides]

This slide deck is an appendix to a paper series that examines potential challenges related to planning future power systems with higher solar photovoltaic (PV) penetrations. The series uses the western U.S. power system for these investigations because it is a region the authors and their colleagues have already extensively studied. We are therefore well-suited to analyze even higher PV penetrations and then examine the results in multiple models to determine whether our current approaches are missing key details that only emerge at higher PV penetrations. This deck details the systems underlying those analyses and how they were modeled using the Resource Planning Model (RPM), a capacity expansion modeling tool. We examine both Western Interconnection-wide and regional results for three regions in the Western U.S. with significantly different existing power systems and connections to neighboring regions; this provides a more balanced picture as to how power systems with high PV penetration might emerge in different contexts and what the resulting grid challenges, if any, might be.

14 SOLAR ENERGY↗

A Methodology to Evaluate the Grid Reliability Impact of Oscillations Induced by Large Loads

The rapid growth of hyperscale AI data centers is bringing renewed attention to the reliability risk that sustained forced oscillations pose to bulk power systems, with cyclic computational workloads emerging as a new forcing source. Unlike the broadband, stochastic disturbances from traditional industrial loads such as arc furnaces, AI training and inference facilities can inject large active power swings concentrated at specific frequencies over extended durations - characteristics that existing grid planning practices do not account for. While the North American Electric Reliability Corporation (NERC) has recognized this gap and called for system-level studies of large load interconnections, no standardized methodology exists to screen, simulate, and quantify these risks at the planning stage. This report presents the Risk Assessment Tool for Large Load-induced Events (RATLLE), a Python-based, publicly available script suite developed at the Pacific Northwest National Laboratory to evaluate bulk power system reliability risks from data center-induced oscillations. RATLLE implements a three-module workflow: a screening module that identifies vulnerable interconnection locations and excitable system modes; a simulation module that models cyclic data center load behavior using a commercial positive sequence simulation platform; and an analysis module that computes risk metrics and generates interactive visualization dashboards. The risk metrics, formulated around simulation observables, map oscillation impacts to a three-stage severity scale spanning latent equipment fatigue through imminent cascading failure. The methodology is demonstrated on two Western Electricity Coordinating Council (WECC) system models: a publicly available 240-bus reduced representation and a detailed 2031 Heavy Winter planning case. Case studies illustrate that even modest 50 MW forced oscillations at resonant frequencies can produce wide-area power swings, N-1 security constraint violations, and cascading generator trips through protection actions - outcomes that would not occur under normal operating conditions without oscillations present. The results underscore the need for standardized oscillation impact assessment in large load interconnection studies and provide a reproducible, extensible framework for utilities to adopt or customize within their existing planning workflows.

Biswas, Shuchismita↗

Fast Iterative Multi-site Hosting Capacity Analysis for Distribution Systems With Search Space Pruning

Interconnection studies for distributed energy resources (DERs) is a time-intensive process, primarily due to the necessity of solving large number of power flow scenarios. Hosting capacity analysis (HCA) is a time-consuming aspect of interconnection studies that is divided into single-site HCA (SHCA) and multi-site HCA (MHCA). From a computational and understandable standpoint, the industry seeks iteration-based solutions for SHCA, although it doesn't maximize the total DER hosting capacity (DERHC) of the grid, as MHCA does. While non-iterative solutions are available for MHCA, they involve a trade-off between the modeling accuracy of the distribution system, solution quality, and ease of understanding. In this work, we present a fast iterative solution for MHCA, reducing computational complexity by eliminating the need to solve power flows for a large amount of search space, thus making iterative solutions feasible. This iterative approach guarantees both a global optimal solution with sufficient time and a fast, close-to-optimal solution through efficient search space pruning. It also easily integrates with existing utility HCA tools. The results are demonstrated on select locations in the IEEE-123 bus system for community-scale interconnection studies. We highlight the benefits of skipping the need to solve millions of power flows, all while maximizing the grid's total DERHC.

Guddanti, Kishan Prudhvi↗

Hot Chips and Hot Interconnects for High End Computing Systems

I will discuss several processors: 1. The Cray proprietary processor used in the Cray X1; 2. The IBM Power 3 and Power 4 used in an IBM SP 3 and IBM SP 4 systems; 3. The Intel Itanium and Xeon, used in the SGI Altix systems and clusters respectively; 4. IBM System-on-a-Chip used in IBM BlueGene/L; 5. HP Alpha EV68 processor used in DOE ASCI Q cluster; 6. SPARC64 V processor, which is used in the Fujitsu PRIMEPOWER HPC2500; 7. An NEC proprietary processor, which is used in NEC SX-6/7; 8. Power 4+ processor, which is used in Hitachi SR11000; 9. NEC proprietary processor, which is used in Earth Simulator. The IBM POWER5 and Red Storm Computing Systems will also be discussed. The architectures of these processors will first be presented, followed by interconnection networks and a description of high-end computer systems based on these processors and networks. The performance of various hardware/programming model combinations will then be compared, based on latest NAS Parallel Benchmark results (MPI, OpenMP/HPF and hybrid (MPI + OpenMP). The tutorial will conclude with a discussion of general trends in the field of high performance computing, (quantum computing, DNA computing, cellular engineering, and neural networks).

Saini, Subhash↗

Integration of energy storage with diesel generation in remote communities

Highlights Battery energy storage may improve energy efficiency and reliability of hybrid energy systems composed by diesel and solar photovoltaic power generators serving isolated communities. In projects aiming update of power plants serving electrically isolated communities with redundant diesel generation, battery energy storage can improve overall economic performance of power supply system by reducing fuel usage, decreasing capital costs by replacing redundant diesel generation units, and increasing generator system life by shortening yearly runtime. Fast-acting battery energy storage systems with grid-forming inverters might have potential for improving drastically the reliability indices of isolated communities currently supplied by diesel generation. Abstract This paper will highlight unique challenges and opportunities with regard to energy storage utilization in remote, self-sustaining communities. The energy management of such areas has unique concerns. Diesel generation is often the go-to power source in these scenarios, but these systems are not devoid of issues. Without dedicated maintenance crews as in large, interconnected network areas, minor interruptions can be frequent and invasive not only for those who lose power, but also for those in the community that must then correct any faults. Although the immediate financial benefits are perhaps not readily apparent, energy storage could be used to address concerns related to reliability, automation, fuel supply concerns, generator degradation, solar utilization, and, yes, fuel costs to name a few. These ideas are shown through a case study of the Levelock Village of Alaska. Currently, the community is faced with high diesel prices and a difficult supply chain, which makes temporary loss of power very common and reductions in fuel consumption very impactful. This study will investigate the benefits that an energy storage system could bring to the overall system life, fuel costs, and reliability of the power supply. The variable efficiency of the generators, impact of startup/shutdown process, and low-load operation concerns are considered. The technological benefits of the combined system will be explored for various scenarios of future diesel prices and technology maintenance/replacement costs as well as for the avoidance of power interruptions that are so common in the community currently. Graphic abstract Discussion In several cases, energy storage can provide a means to promote energy equity by improving remote communities’ power supply reliability to levels closer to what the average urban consumer experiences at a reduced cost compared to transmission buildout. Furthermore, energy equity represents a hard-to-quantify benefit achieved by the integration of energy storage to isolated power systems of under-served communities, which suggests that the financial aspects of such projects should be questioned as the main performance criterion. To improve battery energy storage system valuation for diesel-based power systems, integration analysis must be holistic and go beyond fuel savings to capture every value stream possible.

25 ENERGY STORAGE↗

Model-Free Primal-Dual Methods for Network Optimization with Application to Real-Time Optimal Power Flow

This paper examines the problem of real-time optimization of networked systems and develops online algorithms that steer the system towards the optimal trajectory without explicit knowledge of the system model. The problem is modeled as a dynamic optimization problem with time-varying performance objectives and engineering constraints. The design of the algorithms leverages the online zero-order primal-dual projected-gradient method. In particular, the primal step that involves the gradient of the objective function (and hence requires a networked systems model) is replaced by its zero-order approximation with two function evaluations using a deterministic perturbation signal. The evaluations are performed using the measurements of the system output, hence giving rise to a feedback interconnection, with the optimization algorithm serving as a feedback controller. The paper provides some insights on the stability and tracking properties of this interconnection. Finally, the paper applies this methodology to a real-time optimal power flow problem in power systems, and shows its efficacy on the IEEE 37-node distribution test feeder for reference power tracking and voltage regulation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Model-Free Primal-Dual Methods for Network Optimization with Application to Real-Time Optimal Power Flow: Preprint

This paper examines the problem of real-time optimization of networked systems and develops online algorithms that steer the system towards the optimal trajectory without explicit knowledge of the system model. The problem is modeled as a dynamic optimization problem with time-varying performance objectives and engineering constraints. The design of the algorithms leverages the online zero-order primal-dual projected-gradient method. In particular, the primal step that involves the gradient of the objective function (and hence requires networked systems model) is replaced by its zero-order approximation with two function evaluations using a deterministic perturbation signal. The evaluations are performed using the measurements of the system output, hence giving rise to a feedback interconnection, with the optimization algorithm serving as a feedback controller. The paper provides some insights on the stability and tracking properties of this interconnection. Finally, the paper applies this methodology to a real-time optimal power flow problem in power systems, and shows its efficacy on the IEEE 37-node distribution test feeder for reference power tracking and voltage regulation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Climate-Water Impacts on Interconnection-Scale Electricity System Planning

A growing literature emphasizes the importance of integrating climate change impacts into electricity system planning. Rising average temperatures can increase and shift electricity demand while reducing generator and transmission efficiency. Changes to water availability and quality can reduce the output of thermally cooled generators and hydropower. Electric power grids across the US and globally are undergoing transformational changes that present new opportunities and challenges to reliability assurance. However, electric utilities and system operators have limited internal capabilities to incorporate these effects into planning practices. This work addresses gaps in utility and system planner practices by integrating climate-water-electricity expertise from universities and U.S. Department of Energy National Laboratories with electricity system planners and stakeholders in the Western Electricity Coordinating Council (WECC). Using a highly collaborative approach, global climate model data, high-resolution hydrology models, and long-term electric sector capacity expansion tools are employed to analyze a range of climate outcomes for future electricity scenarios aligned with recent WECC planning studies. Doing so allows WECC to expand its climate-agnostic planning assessments to consider how future temperature and precipitation patterns could influence generation and transmission planning. We explore how changes to climate-water conditions can affect power plant investment and operation, system economics, and environmental impacts, providing an expanded perspective on interconnection-wide decision making under climate uncertainty.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Small Reactors in Microgrids: Technical Studies Guidance

This report provides initial guidance for the technical studies that are needed for the integration of small reactors (SR)—i.e., small modular reactors (SMR) and microreactors—in microgrids. Power-system engineering issues related to the configuration of these microgrids and their interconnection and interaction with the grid are identified. This guidance applies microgrid concepts to the deployment of SRs for a range of use cases (scenarios). Further, it identifies issues and necessary studies related to laboratory testing and validation of various configurations of SR in microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine Learning Guided Operational Intelligence from Synchrophasors (Final Report)

Schweitzer Engineering Laboratories (SEL) and Oregon State University (OSU) received over 27 terabytes of electrical power system phasor measurement unit (PMU) data for the Eastern, Western, and ERCOT interconnections. The dataset includes measurements spread across 446 PMUs from early 2016 to mid 2018 depending on the interconnect. The full dataset was split into a training and test (holdout) dataset by PNNL. All data was received in the Apache Parquet format. The overarching goal of this project is to develop and execute a strategy to mitigate data anomalies, perform analysis on the dataset, and detect anomalous events in the data.

24 POWER TRANSMISSION AND DISTRIBUTION↗