Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system event”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The Effect of Power Electronic Loads on Western Interconnection Stability

The prevalence of power electronics in the bulk power system is increasing rapidly in both the generation and consumption of electricity. This work focuses on the effect of changing load composition - specifically the transition from single phase air conditioner motors to power electronics backed air conditioners - on power system stability. Various transmission and generation contingency events for the Western Interconnection were simulated using Positive Sequence Load Flow software and planning models from the Western Electricity Coordinating Council. In general, an increased proportion of power electronic load leads to more instability. For some specific faults resulting in fault-induced delayed voltage recovery, transitioning to higher proportions of power electronic loads helps expedite system recovery. These results demonstrate that load composition should be examined in conjunction with generation composition when evaluating system stability.

FIDVR↗

Effects on Structure’s Electromagnetic Shielding Effectiveness Considering Penetrating Cables Coupling Energy from HEMP Event

The threat of weaponized electromagnetic pulse (EMP) is a serious factor in defining power system resilience. Without adequate knowledge regarding the interaction between EMP and power system infrastructure, system personnel may be unable to plan for and operate during an EMP event and major blackouts could occur. This work studies the interaction between EMP and structures, specifically analyzing the shielding effectiveness of buildings emulating power generation facilities. The main focus is to determine how penetrating cables affect the structure’s shielding effectiveness. Several cable parameters including height above ground, radius, termination configuration, and length are analyzed via computational electromagnetic simulations. Results demonstrated penetrating cables can significantly diminish a structure’s shielding effectiveness, especially the electric field. Length of cable is the most influential parameter.

Mignardot, David↗

Performance evaluation of a Terry GS-2 steam impulse turbine with air-water mixtures

Terry steam turbines are widely used in various industries because of their robust design. Within the nuclear power generation industry, they are used in the Reactor Core Isolation Cooling System to remove decay heat during reactor isolation events. During the Fukushima Daiichi nuclear power station disaster in Japan in 2011, the Reactor Core Isolation Cooling System and associated Terry turbine operated for over 70 hours in Unit 2; this runtime is well beyond the expected operating duration. Theories suggest the turbine was subjected to a two-phase inlet flow, which could degrade the turbine performance. In this work, an experimental test rig was constructed to test a full-scale Terry model GS-2 steam turbine under two-phase air/water flows. Steady-state efficiency and torque performance maps of the turbine were developed over a range of turbine inlet pressures (1.38–4.83 bar or 20–70 psia), air mass fractions (0.05–1.0) and rotational speeds up to 4000 RPM. Furthermore, turbine performance followed expected trends with torque varying linearly and efficiency varying quadratically with rotational speed. In addition, high-speed images of the two-phase flow entering the turbine were also analyzed to understand how changes in inlet pressure and air mass fraction affect the flow regime and homogenization. The present tests with air–water two-phase mixtures are an important step towards providing an understanding of the full-scale Terry turbine’s behavior and performance curves under two-phase conditions. The results of this work will be combined with air/water and steam/water data gathered using a small-scale Terry ZS-1 steam turbine in order to understand the scaling relationship between large and small size Terry turbines and fluid pairs. The combined data set will enable further development of analytical models over a wide range of conditions and may be used to provide technical justification for expanded use of the Terry turbines in nuclear power plant safety systems and other systems.

42 ENGINEERING↗

Performance Evaluation of Multi-Vendor Grid-Forming Inverters for Grid-Connected Operation Through Hardware Experimentation: Preprint

Existing real-world projects of GFM inverters that operate in parallel to power grids typically are sized between dozens and a few hundreds Megawatt (MW) scale according to a recent NERC GFM inverter white paper. These large systems are often difficult to evaluate prior to deployments because of their large size. The performance of smaller GFM inverters (dozens to a few hundreds MW) that operate parallel with power grids (distribution systems) is even less understood. There is an opportunity to better understand these systems through hardware testing under controlled laboratory conditions. Therefore, this paper presents the functional performance evaluation tests of multiple (three) commercial GFM inverters when they operate in parallel with the grid through hardware experiments. The goal of these tests is to explore the GFM inverters' functionalities and dynamic response when in parallel with power grids to eventually develop universal specifications for GFM inverters. Both steady state (changing the inverter's frequency and voltage droop) and transient (adding step change in grid's frequency/voltage) tests are performed for each GFM inverter with the same testing circuit and testing protocol. The experimental results indicate the bench-marked performance that: 1) the GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power when paralleled to the grid; 2) the GFM inverters automatically respond to system frequency and voltage events to output the needed power, however, the GFM inverters all show stability issues when absorbing reactive power from the grid.

grid-forming inverters↗

Monte Carlo-based Transmission and Subtransmission Recovery Simulation of Hurricanes

High-impact low-probability (HILP) events can wreak havoc on electric power systems without appropriate preparedness. In this paper, the recent development of a tool, named Recovery Simulator and Analysis (RSA), is described and demonstrated. While there are many issues to consider when recovering electric power systems, the focus of RSA is on the coordination of transmission and subtransmission recovery with generation dispatch to minimize unserved energy. RSA focuses on recovery simulation to evaluate resilience as part of a planning process. RSA is demonstrated on an approximately 1400-bus Puerto Rican power system for 100 simulated instances of Hurricane Maria. Analysis of the recovery determines how many lines are critical to the recovery and which loads may experience delayed recovery. The results demonstrate the potential uses of RSA for identifying recovery decisions with low unserved energy and for identifying assets critical to recovery which can then be hardened prior to a HILP event.

Maloney, Patrick R.↗

An Operational Resilience Metric for Modern Power Distribution Systems

The electrical power system is the backbone of our nations critical infrastructure. It has been designed to withstand single component failures based on a set of reliability metrics which have proven acceptable during normal operating conditions. However, in recent years there has been an increasing frequency of extreme weather events. Many have resulted in widespread long-term power outages, proving reliability metrics alone do not provide adequate energy security. As a result, researchers have focused their efforts on a new set of metrics based on the concept of resilience to ensure efficient operation of power systems during extreme events. A resilient system has the ability to resist, adapt, and recover from disruptions. Therefore, resilience has demonstrated itself as a promising concept for currently faced challenges in power distribution systems. In this work, we propose a real-time resilience metric for modern power distribution systems. The metric is an aggregation of the controllable assets adaptive capacity, or their temporal flexibility in real and reactive power. This metric gives information to the magnitude and duration of a disturbance which the system can respond to without having to drop loads or have stability issues in voltage or frequency. We demonstrate the impact to resilience in a case study under normal operation and during a power contingency on a microgrid. In the future, this information can be used by operators to make more informed decisions based on system resilience in an effort to prevent power outages.

42 ENGINEERING↗

PROS: An IRAF based system for analysis of x ray data

PROS is an IRAF based software package for the reduction and analysis of x-ray data. The use of a standard, portable, integrated environment provides for both multi-frequency and multi-mission analysis. The analysis of x-ray data differs from optical analysis due to the nature of the x-ray data and its acquisition during constantly varying conditions. The scarcity of data, the low signal-to-noise ratio and the large gaps in exposure time make data screening and masking an important part of the analysis. PROS was developed to support the analysis of data from the ROSAT and Einstein missions but many of the tasks have been used on data from other missions. IRAF/PROS provides a complete end-to-end system for x-ray data analysis: (1) a set of tools for importing and exporting data via FITS format -- in particular, IRAF provides a specialized event-list format, QPOE, that is compatible with its IMAGE (2-D array) format; (2) a powerful set of IRAF system capabilities for both temporal and spatial event filtering; (3) full set of imaging and graphics tasks; (4) specialized packages for scientific analysis such as spatial, spectral and timing analysis -- these consist of both general and mission specific tasks; and (5) complete system support including ftp and magnetic tape releases, electronic and conventional mail hotline support, electronic mail distribution of solutions to frequently asked questions and current known bugs. We will discuss the philosophy, architecture and development environment used by PROS to generate a portable, multimission software environment. PROS is available on all platforms that support IRAF, including Sun/Unix, VAX/VMS, HP, and Decstations. It is available on request at no charge.

Conroy, M. A.↗

Backup Power Performance of Solar-plus-Storage Systems during Routine Power Interruptions: A Case Study Application of Berkeley Lab’s PRESTO Model

This technical brief estimates the expected performance of a solar photovoltaic and energy storage system (PVESS) for providing backup power during short-duration power interruption events, accounting for the unpredictable nature of those events. The analysis relies on the Power Reliability Event Simulation TOol (PRESTO), a publicly available model developed by Berkeley Lab to simulate the occurrence of short-duration power interruption events at the county-level. A separate storage dispatch model is then used to simulate PVESS operation and backup performance for each of the large number of interruption events produced by PRESTO. In performing this simulation, the analysis accounts for how the customer operates its battery on a day-to-day basis—in this case, we assume the battery is cycled each day in response to time-of-use rates—and how that, in turn, impacts the battery’s state of charge at the beginning of each interruption event. The analysis presented here is intended to demonstrate an application of the PRESTO model as well as to illustrate some of the key determinants of PVESS backup power performance during short-duration power interruption events. The analysis focuses initially on a typical single-family home in Maricopa County, Arizona, and includes a limited set of scenarios related to system sizing, backup power configuration, and whether the customer charges its battery storage system from the grid during normal operating conditions. The analysis also presents comparative results for two other counties, in Massachusetts (Middlesex) and California (Los Angeles), illustrating how regional differences in climate, interruption patterns, and retail rate structures can affect PVESS performance as a backup power source. In the conclusions, we highlight a number of other important considerations for evaluating PVESS backup power capabilities.

14 SOLAR ENERGY↗

Online Event Detection in Synchrophasor Data with Graph Signal Processing

Online detection of anomalies is crucial to enhancing the reliability and resiliency of power systems. We propose a novel data-driven online event detection algorithm with synchrophasor data using graph signal processing. In addition to being extremely scalable, our proposed algorithm can accurately capture and leverage the spatio-temporal correlations of the streaming PMU data. This paper also develops a general technique to decouple spatial and temporal correlations in multiple time series. Finally, we develop a unique framework to construct a weighted adjacency matrix and graph Laplacian for product graph. Case studies with real-world, large-scale synchrophasor data demonstrate the scalability and accuracy of our proposed event detection algorithm. Compared to the state-of-the-art benchmark, the proposed method not only achieves higher detection accuracy but also yields higher computational efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hydroclimate-coupled framework for assessing power system resilience under summer drought and climate change

Extreme drought, exacerbated by climate change, increasingly threatens power system resilience, and a systematic assessment of such impacts is challenging due to the unpredictability of drought and their associated modeling complexity. Here, to address the challenge, this research develops a hydroclimate-coupled power system resilience assessment framework that enables systematic modeling of drought and climate change impacts on generation, transmission, and demand sectors. Applying the framework to the 2025 Eastern U.S. power grid — comprising 6,055 at-risk generators — under climate-induced summer drought scenarios (including SSP126, SSP245, SSP370, and SSP585) from 2023 to 2100, the study finds that climate-induced droughts could jeopardize the power system’s reliability to a greater extent than historical events, potentially leading to widespread load shedding. More specifically, the study reveals that under the twenty-one representative drought scenarios, the loss of load expectation (LOLE) of the grid could range from 34.77 to 91.48 days per summer. The simulations indicate that implementing resilience enhancement strategies is crucial to ensure reliable system operation, which encompasses initiatives such as demand response, upgrading open cooling systems, and transmission expansion. In all, these findings underscore the urgent need for proactive planning and investment in resilient U.S. power systems to mitigate the impacts of extreme drought events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Regional Real-Time PV Spinning Reserve Estimator

Curtailed photovoltaic (PV) generation is a zero-marginal-cost spinning reserve that can be used for a number of active power control services. Unlike traditional spinning reserve providers, however, i.e., fossil-fueled generators, which have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate knowledge of the PV PHL is essential. It ensures that enough headroom is reserved by the PV plants to deliver the award services in real time and informs feasible dispatch decisions made by the market operator. To tackle this challenge, a novel reference-control grouping-based PV plant reserve estimation method has been proposed by the National Renewable Energy Laboratory under past projects funded by the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office. The estimation method separates inverters within a plant into two groups: a control group and a reference group. While the reference group is reserved to operate at its PHL, the control group can be curtailed to provide the grid services. Real-time outputs from the reference inverters are used to estimate the PHL for the whole plant based on the ratio between capacities of the reference group and of the plant. This work further enhances the methodology by (1) improving the model accuracy through machine learning; (2) automating the reference inverter selection through correlation analysis; (3) considering estimation look-ahead windows; and (4) applying to regional spinning reserve estimation. Significant performance improvement has been observed based on real-world data collected by CAISO, Southern Company, and Terabase Energy. Compared with the original scaling method, the newly proposed machine learning-based approach reduces the estimation errors by 30% and 13% at the plant level and region level, respectively. Results obtained from this project are intended to be used by grid operators, market operators, balancing authorities, and PV plant owners and operators to facilitate PV participation in ancillary service markets. Regulators, policymakers, and system planners can also consider the results of this work in their decision-making processes. In addition to the performance improvement on the existing reference-control based grouping method, we also investigated how the variability of PV generation from a single PV inverter can be used to represent the variability of PV generation at the plant level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilience of electric utilities during the COVID-19 pandemic in the framework of the CIGRE definition of Power System Resilience

Resilience is a vital concept in engineering, business, and natural sciences, and is a measure of the ability of an entity to withstand High Impact Low Probability (HILP) events. During the COVID-19 pandemic, which started in late 2019/early 2020, power system utilities around the globe have responded in effective and efficient ways to enhance the resilience of their organisations, both in terms of real-time operations and prudent management of its infrastructure, in order to continue their mandate in providing reliable supply to meet customer demands. Here, this paper presents the CIGRE definition for power system resilience, established by the C4.47 Working Group in 2018, and demonstrates the application of resilience-oriented thinking within the electrical sector. The response and recovery efforts are described, with respect to the key actionable measures integral to the power system resilience definition, taken before, during and after the COVID-19 pandemic. A practical conceptual framework is also presented for thinking about resilience in terms of three key components of resilience strategies: organisational, infrastructure and operational resilience. The paper also discusses the different strategies adopted in response to COVID-19, based on the C4.47 members’ experiences during the pandemic. Finally, a case study is presented, which proves the effectiveness of a set of response measures, using graph theory and the characteristics of the staff-asset interactions.

42 ENGINEERING↗

Online Event Detection in Synchrophasor Data with Graph Signal Processing

Online detection of anomalies is crucial to enhancing the reliability and resiliency of power systems. We propose a novel data-driven online event detection algorithm with synchrophasor data using graph signal processing. In addition to being extremely scalable, our proposed algorithm can accurately capture and leverage the spatio-temporal correlations of the streaming PMU data. This paper also develops a general technique to decouple spatial and temporal correlations in multiple time series. Finally, we develop a unique framework to construct a weighted adjacency matrix and graph Laplacian for product graph. Case studies with real-world, large-scale synchrophasor data demonstrate the scalability and accuracy of our proposed event detection algorithm. Compared to the state-of-the-art benchmark, the proposed method not only achieves higher detection accuracy but also yields higher computational efficiency.

Event detection↗

A Data-Driven Method for Synthetic Extreme Weather Generation and Solar Impact Assessment: Preprint

High-resolution, high-fidelity weather datasets are essential for testing and evaluating the resilience of power systems, particularly under extreme weather conditions. However, existing extreme weather datasets are typically derived from historical events that are localized and may lack the spatial and temporal resolution or scenario diversity needed to test largescale power systems. In this work, we propose a synthetic extreme weather simulation approach capable of generating targeted extreme events, such as hurricanes, using publicly available data sources. Preliminary results demonstrate the impact of a simulated Category 1 hurricane on renewable generation and critical infrastructure in California. The work aims to provide a flexible approach for creating multiple types of extreme weather scenarios across different regions, enabling comprehensive system stress testing, training, and resilience assessment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Near-Real-Time Model for Predicting Electricity Disruptions in Texas During Winter Storms

There has been an increase in extreme weather events, posing a threat to power grid systems, potentially influenced by factors such as population growth, changes in ecosystems, land cover, and land use in the service area, as well as the growth of certain vegetation types. This research seeks to develop a predictive model to mitigate potential damages caused by future winter storms. This research utilizes the Light Gradient Boosting Machine (LightGBM), incorporating the number of power outages experienced at the county level, geographic details, weather information, and lagged outage and lagged weather data. The developed models were broadly divided into two groups, with six models in each group - one group without optimization and another with optimization, totaling 12 trained models. For model optimization, Bayesian optimization was employed using Root Mean Squared Error (RMSE) as the objective function. In results, when comparing Group 2 (the optimized group) with Group 1 (the non-optimized group), it was found that optimization did not always lead to a reduction in RMSE and Mean Absolute Error (MAE). However, in terms of Mean Directional Accuracy (MDA), while all results in Group 1 were below the baseline accuracy of 0.33, all results in Group 2 exceeded 0.33, with some cases showing an increase of more than three times the baseline. The results indicated that, in the optimized model group, Population and Pressure were the most influential factors when using current weather data and geographical information. When using lagged data, lagged recorded outages and lagged Pressure emerged as the most significant factors. Among the 12 developed models, the L-1-2-O model showed the lowest RMSE and MAE, as well as the highest accuracy, with values of 390.62 households and 168.13 households, respectively. To normalize the RMSE and MAE values, each metric was divided by the average number of households among the counties in Texas. For the L-1-2-O model, the scaled RMSE was 0.88% and the scaled MAE was 0.38%. In terms of MDA, which indicates the accuracy of the prediction direction, the L-1-O model achieved the highest score of 0.41. Although this study focused on Texas, which suffered the greatest impact from the winter storms in 2021, with additional validation, the methodology used in this research could be applied to other regions.

Lee, Jangjae [Texas A & M Univ., College Station, ↗

In-Operando Characterization of P-I-N Perovskite Solar Cell Under Reverse Bias

A solar module is often exposed to a variety of intensity and uniformity illumination conditions throughout a day. In the field, objects or dirt can block light from hitting the module creating a partial shading event. When a partial shading event occurs the module power point tracking system will typically push the shaded cells into reverse bias in order to avoid the current loss from the other series connected illuminated cells. When perovskite solar cells are operated in reverse bias, electrochemical reactions can occur, leading to both reversible and irreversible performance losses. Excess holes generated by reverse bias cause and push the oxidation reaction of halide ions from the lattice to neutral halogen interstitial. Small interstitial halogen atoms can diffuse across the device and potentially move from the perovskite layer and into the transport layers, shifting the fermi levels in the devices. In this investigation we utilize cross-sectional kelvin probe atomic force microscopy to map the band energetics of perovskite solar cells during reverse bias. We observe a 150 meV decrease in the work function of the C 60 . This leads to a decrease of 150 mV and 4 mA/cm 2 in V oc and in J sc respectively. Finally, we discuss methods to prevent this irreversible degradation after a perovskite device is held under reverse bias.

fullerene↗

Real-Time Regional PV Spinning Reserve Estimator with AGC Look-Ahead Windows

Curtailed PV generation is a zero-marginal cost spinning reserve that can be used for a number of active power control services. However, unlike the traditional spinning reserve providers, i.e., fossil-fueled generators, who have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate forecasts of the PV PHL are essential. A novel reference-control grouping based scaling method has been proposed by NREL to estimate the PV PHL in real-time. This work further enhances the methodology by: 1) improving the model accuracy through machine learning; 2) considering look-ahead windows introduced by the computation and communication latencies; 3) applying the method to regional spinning reserve estimation. A significant performance improvement, over 99% of estimation error reduction, has been observed based on real-world data collected by CAISO and PV plant operators.

potential high limit↗

Safe atmosphere entry of an isotope heat source with a single stable trim attitude at hypersonic speeds

A theoretical investigation has been made to design an isotope heat source capable of satisfying the conflicting thermal requirements of steady-state operation and atmosphere entry. The isotope heat source must transfer heat efficiently to a heat exchange during normal operation with a power system in space, and in the event of a mission abort, it must survive the thermal environment of atmosphere entry and ground impact without releasing radioactive material. A successful design requires a compatible integration of the internal components of the heat source with the external aerodynamic shape. To this end, configurational, aerodynamic, motion, and thermal analyses were coupled and iterated during atmosphere entries at suborbital through superorbital velocities at very shallow and very steep entry angles. Results indicate that both thermal requirements can be satisfied by a heat source which has a single stable aerodynamic orientation at hypersonic speeds. For such a design, the insulation material required to adequately protect the isotope fuel from entry heating need extend only half way around the fuel capsule on the aerodynamically stable (wind-ward) side of the heat source. Thus, a low-thermal-resistance, conducting heat path is provided on the opposite side of the heat source through which heat can be transferred to an adjacent heat exchanger during normal operation without exceeding specified temperature limits.

Levy, L. L., Jr.↗