Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “positivity preservation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Space Debris: Its Causes and Management

Orbital debris is internationally recognized as an environmental issue which needs to be addressed today to preserve near-Earth space for future generations. All major space agencies are committed to mitigating the growth of the debris environment. Many commercial space system operators have responded positively to orbital debris mitigation principles and recommendations. Orbital debris mitigation measures are most cost-effective if included in the design development phase.

Johnson, Nicholas L.↗

Dual stage check valve

A dual stage seat valve head arrangement is described which consists of a primary sealing point located between a fixed orifice seat and a valve poppet, and a secondary sealing point between an orifice poppet and a valve poppet. Upstream of the valve orifice is a flexible, convoluted metal diaphragm attached to the orifice poppet. Downstream of the valve orifice, a finger spring exerts a force against the valve poppet, tending to keep the valve in a closed position. The series arrangement of a double seat and poppet is able to tolerate small particle contamination while minimizing chatter by controlling throttling or metering across the secondary seat, thus preserving the primary sealing surface.

Whitten, D. E.↗

Protecting the GEO Environment: Policies and Practices

The geosynchronous orbital regime has long been recognized as a unique space resource, dictating special measures to ensure its continuing use for future generations. During the past 20 years a variety of national and international policies have been developed to preserve this environment. A review of current practices involving the deployment and disposal of geosynchronous spacecraft, associated upper stages and apogee kick motors, and geosynchronous orbit transfer objects indicates both positive and negative trends. Most spacecraft operators are indeed performing end-of-mission maneuvers, but the boost altitudes normally fall short of policy guidelines. Russia, a major operator in geosynchronous orbit, maneuvers only 1 in 3 spacecraft out of the region, while China has never refired a spacecraft above GEO. The viability of voluntary protection measures for this regime depends upon the responsible actions of the aerospace community as a whole.

Johnson, Nicholas L.↗

A Fresh Look at the Stratigraphy of Northern Australe

The roughly circular collection of mare deposits centered at ~38.9°S, 93°E is often re- ferred to as Mare Australe. It is located outside of the Procellarum KREEP Terrain. The circular arrangement of Australe’s mare patches has suggested an ancient, heavily degraded or relaxed impact basin roughly 900 km in diameter. The mare deposits are generally thought to have erupted into smaller post- basin craters. The type, volume, and distribution of mare eruptions potentially resembles the early stages of basin-filling mare events, but which are preserved in Australe and some farside locations. Gravity data suggest that if there was a basin, it is much smaller than originally proposed (now ~600 km) and located in the northern part of Mare Australe, between Humboldt, Milne, and Jenner craters. As a whole, Mare Australe lacks the topography typically associated with a basin; however, northern Australe has a slight topographic depression that roughly corresponds to the basin-like Bouguer gravity signature in the same area. The compositions exposed in Humboldt crater suggest that a preexisting basin might have excavated deeper crustal material. However, the underlying cause of the circularity of Mare Australe’s deposits, particularly those extending outside of the potential impact basin setting, is not yet understood. Thus, Australe may preserve fundamental information about mare volcanism potentially uncoupled from basin formation and structure. The objectives of this study are to use new high- resolution data (images, gravity, topography, and com- position) to reassess Australe’s mare deposits, deter- mine the timing and style of volcanism, identify discrete basalt deposits, and to further characterize the evolution of magmatism and subsurface structure in this area. Here, we focus on the northern Australe deposits (between Humboldt, Jenner, and Milne). As originally noted by Whitford-Stark (1979), Humboldt crater and its ejecta make an excellent stratigraphic marker that can be traced across much of the Australe region. The ejecta serves as a stratigraphic constraint for absolute model ages (AMAs) derived from crater size-frequency distributions (CSFDs).

Stopar, J. D.↗

Prokaryotic and Fungal Characterization of the Facilities Used to Assemble, Test, and Launch the OSIRIS-REx Spacecraft

To characterize the ATLO (Assembly, Test, and Launch Operations) environment of the OSIRIS-REx spacecraft, we analyzed 17 aluminum witness foils and two blanks for bacterial, archaeal, fungal, and arthropod DNA. Under NASA’s Planetary Protection guidelines, OSIRIS-REx is a Category II outbound, Category V unrestricted sample return mission. As a result, it has no bioburden restrictions. However, the mission does have strict organic contamination requirements to achieve its primary objective of returning pristine carbonaceous asteroid regolith to Earth. Its target, near-Earth asteroid (101955) Bennu, is likely to contain organic compounds that are biologically available. Therefore, it is useful to understand what organisms were present during ATLO as part of the larger contamination knowledge effort—even though it is unlikely that any of the organisms will survive the multi-year deep space journey. Even though these samples of opportunity were not collected or preserved for DNA analysis, we successfully amplified bacterial and archaeal DNA (16S rRNA gene) from 16 of the 17 witness foils containing as few as 7 ± 3 cells per sample. Fungal DNA (ITS1) was detected in 12 of the 17 witness foils. Despite observing arthropods in some of the ATLO facilities, arthropod DNA (COI gene) was not detected. We observed 1,009 bacterial and archaeal sOTUs (sub-operational taxonomic units, 100% unique) and 167 fungal sOTUs across all of our samples (25–84 sOTUs per sample). The most abundant bacterial sOTU belonged to the genus Bacillus. This sOTU was present in blanks and may represent contamination during sample handling or storage. The sample collected from inside the fairing just prior to launch contained several unique bacterial and fungal sOTUs that describe previously uncharacterized potential for contamination during the final phase of ATLO. Additionally, fungal richness (number of sOTUs) negatively correlates with the number of carbon-bearing particles detected on samples. The total number of fungal sequences positively correlates with total amino acid concentration. These results demonstrate that it is possible to use samples of opportunity to characterize the microbiology of low-biomass environments while also revealing the limitations imposed by sample collection and preservation methods not specifically designed with biology in mind.

Aaron B. Regberg↗

A projection method for particle resampling

Particle discretizations of partial differential equations are advantageous for high-dimensional kinetic models in phase-space due to their better scalability than continuum approaches with respect to dimension. Complex processes collectively referred to as particle noise hamper long time simulations with particle methods. One approach to address this problem is particle mesh adaptivity, or remapping, known as particle resampling and remeshing. Here, this work introduces a resampling method that projects particles to and from a (finite element) function space. The method is simple, using standard sparse linear algebra and finite element techniques, and it preserves all moments up to the order of a polynomial represented exactly by the continuum function space. It is distinguished from most other mesh-based methods in that new particle positions and number are decoupled from the mesh, allowing particle and continuum meshes to be adapted relatively independently. While this work is developed with structured particle and continuum phase-space grids on 1X + 1V Vlasov-Poisson models of Landau damping and two-stream instability, the method is well-suited to unstructured grids. Stable long time dynamics are demonstrated up to time T = 500. Reproducibility artifacts and data are publicly available.

Kinetic methods↗

Extracellular filaments revealed by affinity capture cryogenic-electron tomography

Cryogenic-electron tomography (cryo-ET) has provided an unprecedented glimpse into the nanoscale architecture of cells by combining cryogenic preservation of biological structures with electron tomography. Micropatterning of extracellular matrix proteins is increasingly used as a method to prepare adherent cell types for cryo-ET as it promotes optimal positioning of cells and subcellular regions of interest for vitrification, cryo-focused ion beam (cryo-FIB) milling, and data acquisition. Here we demonstrate a micropatterning workflow for capturing minimally adherent cell types, human T cells and Jurkat cells, for cryo-FIB and cryo-ET. Our affinity capture system facilitated the nanoscale imaging of Jurkat cells, revealing extracellular filamentous structures. It improved workflow efficiency by consistently producing grids with a sufficient number of well-positioned cells for an entire cryo-FIB session. Affinity capture can be extended to facilitate high-resolution imaging of other adherent and non-adherent cell types with cryo-ET.

Biochemistry↗

Tomography of Atomic Nuclei

We carry out continuum quantum Monte Carlo calculations of the quantum-mechanical Wigner distribution functions of selected nuclei, up to $^{16}$O. These distributions provide a form of quantum tomography of the spatial and momentum structure of the system. They also help identify the location of high-momentum regions in atomic nuclei and provide insight into the onset of alpha clustering. Besides their intrinsic interest, these distributions will be useful for neutrino event generators, as they correlate the positions and momenta of nucleons in the initial target state. To facilitate their application, we address the need to store them compactly by developing an accurate Gaussian Process emulator that automatically preserves their normalization.

Rocco, Noemi [Valencia U., IFIC; Fermilab]↗

CLPNets: Coupled Lie–Poisson neural networks for multi-part Hamiltonian systems with symmetries

To accurately compute data-based prediction of Hamiltonian systems, it is essential to utilize methods that preserve the structure of the equations over time. We consider a particularly challenging case of systems with interacting parts that do not reduce to pure momentum evolution. Such systems are essential in scientific computations, such as discretization of a continuum elastic rod, which can be viewed as the group of rotations and translations $SE(3)$. The evolution involves not only the momenta but also the relative positions and orientations of the particles. The presence of Lie group-valued elements, such as relative positions and orientations, poses a problem for applying previously derived methods for data-based computing. We develop a novel method of data-based computation and complete phase space learning of such systems. We follow the original framework of SympNets (Jin et al., 2020) and LPNets (Eldred et al., 2024), building the neural network from phase space mappings that preserve the Lie–Poisson structure. We derive a novel system of mappings that are built into neural networks describing the evolution of such systems. We call such networks Coupled Lie–Poisson Neural Networks, or CLPNets. We consider increasingly complex examples for the applications of CLPNets, starting with the rotation of two rigid bodies about a common axis, progressing to the free rotation of two rigid bodies, and finally to the evolution of two connected and interacting $SE(3)$ components, describing the discretization of an elastic rod into two elements. Our method preserves all Casimir invariants to machine precision, preserves energy to high accuracy, and shows good resistance to the curse of dimensionality, requiring only a few thousand data points for all cases studied (three to eighteen dimensions). Additionally, the method is highly economical in memory requirements, requiring only about 200 parameters for the most complex case considered.

Data-based modeling↗

A Technique for Mapping Characteristic Lengths to Preserve Energy Dissipated via Strain Softening in a Multiscale Analysis

It is often advantageous to account for the microstructure of the material directly using multiscale modeling. For computational tractability, an idealized repeating unit cell (RUC) is used to capture all of the pertinent features of the microstructure. Typically, the RUC is dimensionless and depends only on the relative volume fractions of the different phases in the material. This works well for non-linear and inelastic behavior exhibiting a positive-definite constitutive response. Although, once the material exhibits strain softening, or localization, a mesh objective failure theories, such as smeared fracture theories, nodal and element enrichment theories (XFEM), cohesive elements or virtual crack closure technique (VCCT), can be utilized at the microscale, but the dimensions of the RUC must then be defined. One major challenge in multiscale progressive damage modeling is relating the characteristic lengths across the scales in order to preserve the energy that is dissipated via localization at the microscale. If there is no effort to relate the size of the macroscale element to the microscale RUC, then the energy that is dissipated will remain mesh dependent at the macroscale, even if it is regularized at the microscale. Here, a technique for mapping characteristic lengths across the scales is proposed. The RUC will be modeled using the generalized method of cells (GMC) micromechanics theory, and local failure in the matrix constituent subcells will be modeled using the crack band theory. The subcell characteristic lengths used in the crack band calculations will be mapped to the macroscale finite element in order to regularize the local energy in a manner consistent with the global length scale. Examples will be provided with and without the regularization, and they will be compared to a baseline case where the size and shape of the element and RUC are coincident (ensuring energy is preserved across the scales).

softening↗

A flexible gyro-fluid system of equations

Gyro-fluid equations are velocity space moments of the gyrokinetic equations. Special gyro-Landau-fluid closures have been developed that include the damping due to kinetic resonances by fitting to the collisionless local plasma response functions. This damping allows for accurate linear eigenmodes to be computed with a relatively low number of velocity space moments compared to the number of velocity quadrature points in gyrokinetic codes. However, none of the published gyro-Landau-fluid closure schemes considers the Onsager symmetries of the resulting quasi-linear fluxes as a constraint. Onsager symmetry guarantees that the matrix of diffusivities is positive definite, an important property for the numerical stability of a transport solver. A two-parameter real closure for improving the accuracy of low-resolution gyro-fluid equations, which preserves the Onsager symmetry and allows higher velocity space moments, is presented in this paper. The new linear gyro-fluid system (GFS) is used to extend the TGLF quasi-linear transport model so that it can compute the energy and momentum fluxes due to parallel magnetic fluctuations, completing the transport matrix. The GFS equations do not use a bounce average approximation. The GFS equations are fully electromagnetic with general flux surface magnetic geometry, pitch angle scattering for electron collisions, and subsonic equilibrium toroidal rotation. Using GFS eigenmodes in the quasi-linear TGLF model will be shown to yield a more accurate match to fluxes computed by CGYRO turbulence simulations. In conclusion, prospects for future applications of a quasi-linear theory to new plasma transport regimes and magnetic confinement devices in addition to tokamaks are opened by the flexibility of the GFS eigensolver.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deactivation of Cu-Exchanged Automotive-Emission NH 3 -SCR Catalysts Elucidated with Nanoscale Resolution Using Scanning Transmission X-ray Microscopy

To gain insight into the underlying mechanisms of catalyst durability for the selective catalytic reduction (SCR) of NO x with an ammonia reductant, we employed scanning transmission X-ray microscopy (STXM) to study Cu-exchanged zeolites with the CHA and MFI framework structures before and after simulated 135 000-mile aging. X-ray absorption near-edge structure (XANES) measurements were performed at the Al K- and Cu L-edges. The local environment of framework Al, the oxidation state of Cu, and geometric changes were analyzed, showing a multi-factor-induced catalytic deactivation. In Cu-exchanged MFI, a transformation of Cu II to Cu I and Cu x O y was observed. We also found a spatial correlation between extra-framework Al and deactivated Cu species near the surface of the zeolite as well as a weak positive correlation between the amount of CuI and tri-coordinated Al. By inspecting both Al and Cu in fresh and aged Cu-exchanged zeolites, we conclude that the importance of the preservation of isolated Cu II sites trumps that of Brønsted acid sites for NH 3 -SCR activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cardiovascular Adjustments to Gravitational Stress

The effects of gravity on the cardiovascular system must be taken into account whenever a hemodynamic assessment is made. All intravascular pressure have a gravity-dependent hydrostatic component. The interaction between the gravitational field, the position of the body, and the functional characteristics of the blood vessels determines the distribution of intravascular volume. In turn this distribution largely determines cardiac pump function. Multiple control mechanisms are activated to preserve optimal tissue perfusion when the magnitude of the gravitational field or its direction relative to the body changes. Humans are particularly sensitive to such changes because of the combination of their normally erect posture and the large body mass and blood volume below the level of the heart. Current aerospace technology also exposes human subjects to extreme variations in the gravitational forces that range from zero during space travel to as much an nine-times normal during operation of high-performance military aircraft. This chapter therefore emphasizes human physiology.

Blomqvist, C. Gunnar↗

Miniature Gas Chromatograph (GC): Penning Ionization Electron Spectroscopy (PIES) Instrument for the Trace Analyses of Extraterrestrial Environments

In situ exploration of the solar system to identify its early chemistry as preserved in icy bodies and to look for compelling evidence of astrobiology will require new technology for chemical analysis. Chemical measurements in space flight environments highlight the need for a high level of positive identification of chemical compounds, since re-measurement by alternative techniques for confirmation will not be feasible. It also may not be possible to anticipate all chemical species that are observed, and important species may be present only at trace levels where they can be masked by complex chemical backgrounds. Up to now, the only techniques providing independent sample identification of GC separated components across a wide range of chemical species have been Mass Spectrometry (MS) and Ion Mobility Spectrometry (IMS). We describe here the development of a versatile and robust miniature GC detector based on Penning Ionization Electron Spectroscopy (PIES), for use with miniature GC systems being developed for planetary missions. PIES identifies the sample molecule through spectra related to its ionization potential. The combination of miniature GC technology with the primary identification capabilities of PIES provides an analytical approach ideal for planetary analyses.

Kojiro, Daniel R.↗

Characterization of retroreflective tape optical properties for use with position-sensitive scintillator detectors

Reflective materials such as Teflon and Enhanced Specular Reflector are commonly used to maximize light collection in scintillator-based radiation detection systems. While effective, in most cases, the spatial information carried by the light is diminished or lost entirely. Retroreflectors, in contrast, better preserve the spatial information and have been shown to improve the localization performance of such systems. In this work, the relative retroreflectivity of a selection of commercial retroreflective tapes and their performance impact when coupled to a plastic scintillator are reported. Finally, we demonstrate improved localization performance with some tapes compared to Teflon and black paint.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cellular remains in a ~3.42-billion-year-old subseafloor hydrothermal environment

Subsurface habitats on Earth host an extensive extant biosphere and likely provided one of Earth’s earliest microbial habitats. Though the site of life’s emergence continues to be debated, evidence of early life provides insights into its early evolution1. Here we present our discovery of exceptionally well-preserved ~3.40-billion-years-old carbonaceous filamentous microfossils that inhabited a paleo-subseafloor hydrothermal vein system of the Barberton greenstone belt (BGB) in South Africa. The distribution of the microfossils in growth position on the walls of the initial conduits created by low- temperature hydrothermal fluid and their morphological and chemical characteristics as investigated over a range of scales, are consistent with an assemblage of methanogens that thrived in an ultramafic volcanic substrate.

Cavalazzi, Barbara↗

Reference Interferometer Using a Semiconductor Laser/LED Reference Source in a Cryogenic Fourier-Transform Spectrometer

A combination of a single mode AlGaAs laser diode and broadband LED was used in a Michelson interferometer to provide reference signals in a Fourier transform spectrometer, the Composite Infrared Spectrometer, on the Cassini mission to Saturn. The narrowband light from the laser produced continuous fringes throughout the travel of the interferometer, which were used to control the velocity of the scan mechanism and to trigger data sampling. The broadband light from the LED produced a burst of fringes at zero path difference, which was used as a fixed position reference. The system, including the sources, the interferometer, and the detectors, was designed to work both at room temperature and instrument operating temperature of 170 Kelvin. One major challenge that was overcome was preservation, from room temperature to 170 K, of alignment sufficient for high modulation of fringes from the broadband source. Another was the shift of the source spectra about 30 nm toward shorter wavelengths upon cooldown.

Martino, Anthony J.↗

Evolution of the Lunar Receiving Laboratory to the Astromaterial Sample Curation Facility: Technical Tensions Between Containment and Cleanliness, Between Particulate and Organic Cleanliness

The Lunar Receiving Laboratory (LRL) was planned and constructed in the 1960s to support the Apollo program in the context of landing on the Moon and safely returning humans. The enduring science return from that effort is a result of careful curation of planetary materials. Technical decisions for the first facility included sample handling environment (vacuum vs inert gas), and instruments for making basic sample assessment, but the most difficult decision, and most visible, was stringent biosafety vs ultra-clean sample handling. Biosafety required handling of samples in negative pressure gloveboxes and rooms for containment and use of sterilizing protocols and animal/plant models for hazard assessment. Ultra-clean sample handling worked best in positive pressure nitrogen environment gloveboxes in positive pressure rooms, using cleanable tools of tightly controlled composition. The requirements for these two objectives were so different, that the solution was to design and build a new facility for specific purpose of preserving the scientific integrity of the samples. The resulting Lunar Curatorial Facility was designed and constructed, from 1972-1979, with advice and oversight by a very active committee comprised of lunar sample scientists. The high precision analyses required for planetary science are enabled by stringent contamination control of trace elements in the materials and protocols of construction (e.g., trace element screening for paint and flooring materials) and the equipment used in sample handling and storage. As other astromaterials, especially small particles and atoms, were added to the collections curated, the technical tension between particulate cleanliness and organic cleanliness was addressed in more detail. Techniques for minimizing particulate contamination in sample handling environments use high efficiency air filtering techniques typically requiring organic sealants which offgas. Protocols for reducing adventitious carbon on sample handling surfaces often generate particles. Further work is needed to achieve both minimal particulate and adventitious carbon contamination. This paper will discuss these facility topics and others in the historical context of nearly 50 years' curation experience for lunar rocks and regolith, meteorites, cosmic dust, comet particles, solar wind atoms, and asteroid particles at Johnson Space Center.

Allton, J. H.↗