Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “point absorber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Revealing Micro-Scale Doping Variations in Thin-Films via Simultaneous Luminescence and Current Collection Measurements

Doping thin films used for photovoltaic absorbers is both critical to maximize device voltage and challenging due to complex interactions between point defects in these materials. Such interactions can result in compensation of the intended dopant species, meaning that the active charge-carrier concentration is lower than the concentration incorporated dopants. Charge-carrier compensation is directly related to the open-circuit voltage (VOC) deficit, or magnitude of VOC relative to the theoretical limit. Understanding how the carrier concentration varies within thin-films is necessary to design material processing schedules to minimize this VOC deficit and produce more efficient devices. Unfortunately, measurements of the free carrier concentration are generally relevant at the device level and cannot resolve local differences. Resolving local doping differences in thin-films such as Cd(Se,Te), CZTS, and CIGSe requires techniques with micron or sub-micron spatial resolution due to the polycrystalline structure as well as intended and unintended composition variations in these materials. In this contribution, we show how simultaneous measurement of cathodoluminescence (CL) and electron-beam-induced current (EBIC) can be used to expose doping variations in Cd(Se,Te) thin-films. Simultaneous collection of these signals reveals unexpected differences in the electric field strength through the device thickness due to spatial variation in the carrier concentration.

41 EE - Solar Energy Technologies Office (EE-4S)↗

HEMODOSE: A Set of Multi-parameter Biodosimetry Tools

After the events of September 11, 2001 and recent events at the Fukushima reactors in Japan, there is an increasing concern of the occurrence of nuclear and radiological terrorism or accidents that may result in large casualty in densely populated areas. To guide medical personnel in their clinical decisions for effective medical management and treatment of the exposed individuals, biological markers are usually applied to examine the radiation induced changes at different biological levels. Among these the peripheral blood cell counts are widely used to assess the extent of radiation induced injury. This is due to the fact that hematopoietic system is the most vulnerable part of the human body to radiation damage. Particularly, the lymphocyte, granulocyte, and platelet cells are the most radiosensitive of the blood elements, and monitoring their changes after exposure is regarded as the most practical and best laboratory test to estimate radiation dose. The HEMODOSE web tools are built upon solid physiological and pathophysiological understanding of mammalian hematopoietic systems, and rigorous coarse-grained biomathematical modeling and validation. Using single or serial granulocyte, lymphocyte, leukocyte, or platelet counts after exposure, these tools can estimate absorbed doses of adult victims very rapidly and accurately. Some patient data in historical accidents are utilized as examples to demonstrate the capabilities of these tools as a rapid point-of-care diagnostic or centralized high-throughput assay system in a large scale radiological disaster scenario. Unlike previous dose prediction algorithms, the HEMODOSE web tools establish robust correlations between the absorbed doses and victim's various types of blood cell counts not only in the early time window (1 or 2 days), but also in very late phase (up to 4 weeks) after exposure

Hu, Shaowen↗

HEMODOSE: A Set of Multi-parameter Biodosimetry Tools

There continues to be important concerns of the possibility of the occurrence of acute radiation syndromes following nuclear and radiological terrorism or accidents that may result in mass casualties in densely populated areas. To guide medical personnel in their clinical decisions for effective medical management and treatment of the exposed individuals, biological markers are usually applied to examine radiation induced biological changes to assess the severity of radiation injury to sensitive organ systems. Among these the peripheral blood cell counts are widely used to assess the extent of radiation induced bone marrow (BM) injury. This is due to the fact that hematopoietic system is a vulnerable part of the human body to radiation damage. Particularly, the lymphocyte, granulocyte, and platelet cells are the most radiosensitive of the blood elements, and monitoring their changes after exposure is regarded as a practical and recommended laboratory test to estimate radiation dose and injury. In this work we describe the HEMODOSE web tools, which are built upon solid physiological and pathophysiological understanding of mammalian hematopoietic systems, and rigorous coarse-grained biomathematical modeling and validation. Using single or serial granulocyte, lymphocyte, leukocyte, or platelet counts after exposure, these tools can estimate absorbed doses of adult victims very rapidly and accurately to assess the severity of BM radiation injury. Some patient data from historical accidents are utilized as examples to demonstrate the capabilities of these tools as a rapid point-of-care diagnostic or centralized high-throughput assay system in a large-scale radiological disaster scenario. HEMODOSE web tools establish robust correlations between the absorbed doses and victim's various types of blood cell counts not only in the early time window (1 or 2 days), but also in very late phase (up to 4 weeks) after exposure.

Hu, Shaowen↗

A surge observed in H alpha and C IV

Results are presented of simultaneous measurements of H-alpha (MSDP at Meudon) and C IV (UVSP onboard SMM) of Active Region 2701 made on October 2, 1980. Isodensity and velocity maps were obtained for both lines and these maps were superimposed. Results show a good correlation between the H-alpha and C IV velocities with a surge being observed for 10 minutes. The base of the surge was determined to be located in a bright point in C IV and H-alpha, while the escaping matter followed the same channel ('absorbing' in H-alpha, 'emitting' in C IV). It was found that the velocity along the surge was about 80 km/s in H-alpha and 100 km/s in C IV. In addition, a loop appeared in C IV during the surge. It is concluded that the vertical pressure gradient was capable of driving the surge.

Schmieder, B.↗

Advanced EMU electrochemically regenerable CO2 and moisture absorber module breadboard

The applicability of the Electrochemically Regenerable Carbon Dioxide and Moisture Absorption Technology to the advanced extravehicular mobility unit was demonstrated by designing, fabricating, and testing a breadboard Absorber Module and an Electrochemical Regenerator. Test results indicated that the absorber module meets or exceeds the carbon dioxide removal requirements specified for the design and can meet the moisture removal requirement when proper cooling is provided. CO2 concentration in the vent gas stream was reduced from 0.52 to 0.027 kPa (3.9 to 0.20 mm Hg) for the full five hour test period. Vent gas dew point was reduced from inlet values of 294 K (69 F) to 278 K (41 F) at the outlet. The regeneration of expended absorbent was achieved by the electrochemical method employed in the testing. An absorbent bed using microporous hydrophobic membrane sheets with circulating absorbent is shown to be the best approach to the design of an Absorber Module based on sizing and performance. Absorber Module safety design, comparison of various absorbents and their characteristics, moisture absorption and cooling study and subsystem design and operation time-lining study were also performed.

Lee, M. C.↗

The Turning Point of the Aerosol Era

Over the CMIP6 historical period (1850–2014), aerosols provided the largest negative forcing compared to all other climate forcings via their ability to absorb or scatter solar radiation and alter clouds. Aerosols played an important role in counterbalancing warming by greenhouse gases (GHGs). Here we study aerosol forcing trends in the CMIP6 simulations of the NASA Goddard Institute for Space Studies (GISS) ocean-atmosphere ModelE version 2.1 (GISS-E2.1-G) using a fully coupled atmospheric composition configuration, including interactive gas-phase chemistry, and either an aerosol microphysical (MATRIX) or a mass-based aerosol (OMA) module. Simulations of the CMIP6 historical period are analyzed as well as four Shared Socioeconomic Pathway (SSP) future scenarios for 2015–2100: SSP1-2.6, SSP2-4.5, SSP3-7.0, and SSP5-8.5. The main conclusion of this study is that aerosol forcing in the GISS model has reached its turning point, switching from globally increasing to a decreasing trend in the first decade of the 21st century. This result is robust, independent of which aerosol module or SSP scenario is used. Non-linear aerosol-cloud interactions dominate as a forcing agent over aerosol-radiation interactions. Aerosols' ability to counterbalance GHG forcing on the global scale is today at a level comparable to that at the beginning of the last century. In the 1980s, the decade of largest global aerosol loads, aerosols balanced up to 80% of GHG forcing. As a consequence, global warming of the last decades, which is primarily driven by greenhouse gases, has been augmented by the effect of decreasing aerosol cooling in our model. By the end of this century, following the SSP scenarios, aerosols will only counterbalance 0%–20% of GHG forcing, depending on model and on scenario.

Aerosol forcing↗

Perovskite on Silicon Tandem Solar Cells

Since installing solar panels costs more than the panels themselves, it is critically important to improve the efficiency of the panels so that fewer panels need to be installed. More than 90% of all panels being manufactured are made with silicon solar cells. The most promising approach to reach 27% is to upgrade the panels by adding a second set of cells with a larger band gap that can harvest the higher energy photons in the visible spectrum and generate a higher voltage than silicon is capable of generating. Perovskite semiconductors are very promising for low-cost tandems because they have high band gaps, can be rapidly printed from solutions and have been used to make 25% efficient cells by themselves. If we show that it is possible to make stable tandems with 30% efficiency using materials that could be deposited at low cost and that the energy yield will not be compromised, then private companies would be able to raise the capital needed to manufacture this technology. The main metrics for this project are the power conversion efficiency of a lab-scale perovskite/silicon tandem and the ability to maintain a high power conversion efficiency in perovskite solar cells after accelerated operational stability testing under maximum power point at elevated temperature and 1 sun illumination. In short, this project demonstrates improvements to the perovskite absorber layer, contacts for the perovskite solar cell, and transparent oxide layers for window electrodes to achieve tandem efficiencies of 25% after one year and 27% after two years. By the end of the project, we identify strategies to further improve light management in the tandem devices and outline a pathway to reach 30%.In parallel, stability testing is conducted to evaluate said absorber and contact layers in the perovskite top cell, demonstrating 1000 hours of operation with less than 10% degradation at 1 sun. Our work on this project has made a leading impact on the development of perovskite/silicon tandems. The triple halide perovskite that we developed using iodide, bromide, and chloride and published in Science in March 2020 has received significant interest from other experts in the field at conferences. We took a silicon bottom cell with 21% efficiency, a technology that is responsible for a $30 billion market, and improved it by 30% relative. In addition, we have demonstrated impressive stability of our perovskite semitransparent top cells used in the tandems, showing for the first time packaged devices that pass a variety of IEC stability tests including damp heat, temperature cycling, and UV exposure tests.

14 SOLAR ENERGY↗

The primary cosmic ray electron spectrum from 10 GeV to about 200 GeV

An ionization spectrometer consisting of 10.8 radiation lengths of tungsten and 35 radiation lengths of iron has been used to determine the energy spectrum of cosmic ray electrons above 10 GeV. The spectrometer was calibrated with electrons from 5.4 to 18 GeV and then flown at an altitude of 6 gm-cm/2 for 16 hours. Separation of electron initiated events from proton events was achieved by utilizing starting point distributions, the shower development in tungsten, and the energy deposited in the large thickness of iron absorber. The exponent of the differential energy spectrum of the electrons is -3.1 + or - 0.2 while the exponent of the background is consistent with the proton exponent of -2.7 + or -0.2.

Silverberg, R. F.↗

Adhesive fracture mechanics

In studies of fracture mechanics the adhesive fracture energy is regarded as a fundamental property of the adhesive system. It is pointed out that the value of the adhesive fracture energy depends on surface preparation, curing conditions, and absorbed monolayers. A test method reported makes use of a disk whose peripheral part is bonded to a substrate material. Pressure is injected into the unbonded central part of the disk. At a certain critical pressure value adhesive failure can be observed. A numerical stress analysis involving arbitrary geometries is conducted.

Bennett, S. J.↗

Top Stack Optimization for Cu 2 BaSn(S, Se) 4 Photovoltaic Cell Leads to Improved Device Power Conversion Efficiency beyond 6%

Earth-abundant and air-stable Cu 2 BaSnS 4-x Se x (CBTSSe) and related thin-film absorbers are regarded as prospective options to meet the increasing demand for low-cost solar cell deployment. Devices based on vacuum-deposited CBTSSe absorbers have achieved record power conversion efficiency (PCE) of 5.2 % based on a conventional device structure using CdS buffer and i-ZnO/ITO window layers, with open-circuit voltage (V OC ) posing the major bottleneck for improving solar cell performance. The current study demonstrates a >20 % improvement in V OC (from 0.62 V to 0.75 V) and corresponding enhancement in PCE (from 5.1 % to 6.2 % without anti-reflection coating; to 6.5 % with MgF 2 anti-reflection coating) for solution-deposited CBTSSe solar cells. This performance improvement is realized by introducing an alternative successive ionic layer adsorption and reaction (SILAR)-deposited Zn 1-x Cd x S buffer combined with sputtered Zn 1-x Mg x O/Al-doped ZnO window/top contact layer, which offer lower electron affinities relative to the conventional CdS/i-ZnO/ITO stack and better matching with the low electron affinity of CBTSSe. A combined experimental (temperature- and light intensity-dependent V OC measurements) and device simulation (SCAPS-1D) evaluation points to the importance of addressing relative band offsets for both the buffer and window layers relative to the absorber in mitigating interfacial recombination and optimizing CBTSSe solar cell performance.

25 ENERGY STORAGE↗

Reduction of temperature rise in high-speed photography

Information is provided on filtration with glass and infrared absorbing and reflecting filters. Glass and infrared filtration is a simple and effective method to reduce the radiation heat transfer associated with continuous high intensity tungsten lamps. The results of a filtration experiment are explained. The figures provide starting points for quantifying the effectiveness of various filters and associated light intensities. The combination of a spectrally selective reflector (hot or cold mirror) based on multilayer thin film principles and heat absorbing or infrared opaque glass results in the maximum reduction in temperature rise with a minimum of incident light loss. Use is recommended of a voltage regulator to further control temperature rise and incident light values.

Slater, Howard A.↗

Reduction of temperature rise in high-speed photography

Information is provided on filtration with glass and infrared absorbing and reflecting filters. Glass and infrared filtration is a simple and effective method to reduce the radiation heat transfer associated with continuous high intensity tungsten lamps. The results of a filtration experiment are explained. The figures provide starting points for quantifying the effectiveness of various filters and associated light intensities. The combination of a spectrally selective reflector (hot or cold mirror) based on multilayer thin film principles and heat absorbing or infrared opaque glass results in the maximum reduction in temperature rise with a minimum of incident light loss. Use is recommended of a voltage regulator to further control temperature rise and incident light values.

Slater, Howard A.↗

A Multiple Parameters Biodosimetry Tool with Various Blood Cell Counts - the Hemodose Approach

There continue to be important concerns about the possibility of the occurrence of acute radiation syndromes following nuclear and radiological terrorism or accidents that may result in mass casualties in densely populated areas. To guide medical personnel in their clinical decisions for effective medical management and treatment of the exposed individuals, biological markers are usually applied to examine radiation induced biological changes to assess the severity of radiation injury to sensitive organ systems. Among these the peripheral blood cell counts are widely used to assess the extent of radiation induced bone marrow injury. This is due to the fact that the hematopoietic system is the most vulnerable part of the human body to radiation damage. Particularly, the lymphocyte, granulocyte, and platelet cells are the most radiosensitive of the blood elements, and monitoring their changes after exposure is regarded as a practical and recommended laboratory test to estimate radiation dose and injury. Based upon years of physiological and pathophysiological investigation of mammalian hematopoietic systems, and rigorous coarse-grained bio-mathematical modeling and validation on species from mouse, to dog, monkey, and human, we have developed a set of software tools Hemodose, which can use single or serial granulocyte, lymphocyte, leukocyte, or platelet counts after exposure to estimate absorbed doses of adult victims very rapidly and accurately. Some patient data from historical accidents are utilized as examples to demonstrate the capabilities of these tools as a rapid point-of-care diagnostic or centralized high-throughput assay system in a large-scale radiological disaster scenario. Most significant to the improvement of national and local preparedness of a potential nuclear/radiological disaster, this HemoDose approach establishes robust correlations between the absorbed doses and victim's various types of blood cell counts not only in the early time window (1 or 2 days), but also in the very late phase (up to 4 weeks) after exposure.

Hu, Shaowen↗

Effect of growth dynamics on the structural, photophysical and pseudocapacitance properties of famatinite copper antimony sulphide colloidal nanostructures (including nanosheets)

Facile phase selective synthesis of copper antimony sulphide (CAS) nanostructures is important because of their tunable photoconductive and electrochemical properties. In this study, off-stoichiometric famatinite phase CAS (fCAS) quasi-spherical and quasi-hexagonal colloidal nanostructures (including nanosheets) of sizes, 2.4–18.0 nm were grown under variable conditions of temperature (60–200 °C), time and oleylamine capping ligand concentration using copper(II) acetylacetonate and antimony(III) diethyldithiocarbamate precursors. Data from powder X-ray diffraction, Raman spectroscopy and high-resolution scanning/transmission electron microscopy confirm the tetragonal structure of the famatinite phase. X-ray photoelectron spectroscopy, transmission electron microscopy and scanning electron microscopy-energy dispersive X-ray spectroscopy data suggest a correlation of particle size, morphology and composition of the off-stoichiometric fCAS nanostructures with growth temperature and time, and oleylamine concentration. The off-stoichiometric Cu 3-a Sb 1+b S 4±c (a, b, c – mole fractions) nanostructures being severely copper-deficient and antimony-rich, exhibit shallow-lying acceptor copper vacancy states, deep-lying donor states of antimony interstitials, sulphur vacancies and antimony-copper antisites and shallow-lying acceptor surface trapping states. Further, these electronic states are likely implicated in tunable UV-visible absorption and bandgaps between 2.3 and 2.8 eV, and broad visible-NIR photoluminescence with fast recombination of radiative lifetimes between 0.2 and 6.2 ns, confirmed from absorption, steady-state and time-resolved photoluminescence spectroscopies. Additionally, cyclic voltammetry and electrochemical impedance spectroscopy confirm that electrodes of the fCAS nanostructures display slightly variable pseudocapacitance of charge-storage primarily via possible sodium ion intercalation with a high specific capacitance of ~84 F g -1 obtained at a scan rate of 5 mV s -1 . Overall, these results show the influence of composition, in particular point defects, phase quality and morphology on the optical and pseudocapacitance properties of fCAS nanostructures, suitable as solar absorbers or electrodes for energy storage devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coupled Dynamical Phase Transitions in Driven Disk Packings

Under the influence of oscillatory shear, a monolayer of frictional granular disks exhibits two dynamical phase transitions: a transition from an initially disordered state to an ordered crystalline state and a dynamic active-absorbing phase transition. Although there is no reason a priori for these to be at the same critical point, they are. Also, the transitions may also be characterized by the disk trajectories, which are nontrivial loops breaking time-reversal invariance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Interstellar scintillation of extragalactic radio sources

Observations of 12 compact extragalactic sources were made at 2695 and 8085 MHz in order to detect weak intensity fluctuations caused by interstellar scintillation. Pulsar data are used to estimate the parameters of the interstellar medium needed to interpret the measured upper limits in terms of source angular diameters which are much larger than the scintillation cutoff diameter. It is shown that the observed source rms brightness temperatures are less than 10 to the 15th K and 10 to the 14th K at 2695 and 8085 MHz, respectively, making self-absorbed proton-synchroton radiation and high-brightness coherent mechanisms unlikely. If the sources are composed of 'point' components, each source can contain no fewer than 10,000 such components.

Condon, J. J.↗

Experimental Investigation of Several Copper and Beryllium Hemispherical Models in Air at Stagnation Temperatures of 2,000 to 3,600 F

As part of an investigation by the National Aeronautics and Space Administration to determine the resistance to heating of various materials when used as a heat sink for hypersonic airframes, hemispherical nose-shape models of beryllium and copper have been tested in a Mach number 4 hot-air jet at stagnation temperatures of 2,000 F to 3,600 F and Reynolds numbers of 1.88 x 10(exp 6) to 2.93 x 10(exp 6). The experimental results of heating on the nose of the beryllium models agreed reasonably well with theoretical results, whereas heating on the nose of the copper models was almost twice that predicted by theory. Heating of the cylindrical wall behind the hemisphere agreed fairly well with that predicted by theory at lower temperatures. Beryllium produced a thin protective oxide when heated to its melting point with no tendency to ignite before melting. Copper produced a somewhat heavier layer of oxide upon heating, and ignited when heated to near its melting point. These tests indicate that beryllium is superior to copper as a heat-sink material because it absorbs more heat per unit weight, has greater resistance to oxidation in heated air, and does not ignite when heated in air up to its melting temperature.

Trout, Otto F., Jr.↗

An Overview of High-Resolution, Non-Dispersive, Imaging Spectrometers for High-Energy Photons

High-resolution x-ray spectroscopy has become a powerful tool for studying the evolving universe. The grating spectrometers on the XMM and Chandra satellites initiated a new era in x-ray astronomy. Despite their successes, there is still need for instrumentation that can provide higher spectral resolution with high throughput in the Fe-K band and for extended sources. What is needed is a non-dispersive imaging spectrometer - essentially a 14-bit x-ray color camera. And a requirement for a nondispersive spectrometer designed to provide eV-scale spectral resolution is a temperature below 0.1 K. The required spectral resolution and the constraints of thermodynamics and engineering dictate the temperature regime nearly independently of the details of the sensor or the read-out technology. Low-temperature spectrometers can be divided into two classes - - equilibrium and non-equilibrium. In the equilibrium devices, or calorimeters, the energy is deposited in an isolated thermal mass and the resulting increase in temperature is measured. In the non-equilibrium devices, the absorbed energy produces quantized excitations that are counted to determine the energy. The two approaches have different strong points, and within each class a variety of optimizations have been pursued. I will present the basic fundamentals of operation and the details of the most successful device designs to date. I will also discuss how the measurement priorities (resolution, energy band, count rate) influence the optimal choice of detector technology.

Kilbourne, Caroline↗