Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Characterization of 244 Cm Neutron Sources

There is a need to find a replacement for the 252 Cf sources currently used in Standards-based performance testing of neutron instrumentation. This is a result of its relatively short half-life, concerns about future availability and recent increases in cost. A potential replacement source, 244 Cm is evaluated in this study where two commercially available sources have been acquired and their neutron emission spectra measured using a pair of spectrometers. Both instruments showed the 244 Cm spontaneous neutron spectrum to be fully consistent with a MCNP6®-calculated spectrum using published Watt fission parameters for 244 Cm. In addition, the emission rate of the weaker 244 Cm source was established through a direct count rate comparison against a calibrated and similarly encapsulated 252 Cf source. The 244 Cm source emission rate was found to be in excellent agreement with value stated on the manufacturer's source certificate. It is concluded that 244 Cm would be an ideal replacement for 252 Cf based on its longer half-life (18.1 y) and its essentially identical neutron emission spectrum. In addition, 244 Cm sources are commercially available at reasonable cost.

244Cm↗

Efficient Mesofluidic Separation of Large Particles in nuclear slurries - 20408

Efficient and effective particle separation is essential to cleanup of many nuclear wastes. For example, particle separation may be used to accelerate settle-decant bottlenecks that limit the throughput necessary to achieve the U.S. Department of Energy waste cleanup mission in a timely manner. Particle separation may be used to protect downstream processing equipment from pulses of solids that may be encountered near (within a few feet of) liquid-solid interfaces during waste transfer operations, thereby preventing work stoppages. Effective particle separation may permit efficient sludge washing. These are only a few of the ways in which particle separation is important. Yet, efficient and effective particle separation in nuclear processing environments remains challenging. For example, settle-decant operations permit larger and heavier particles to settle, leaving smaller, lighter particles suspended. However, settle-decant operations are slow, convection currents may resuspend solids, hindered settling of multicomponent slurries remains incompletely understood, and predictive models for settling in graduated cylinders fail to match limited observations of settling in large waste tanks. Additionally, pumping operations can cause turbulent resuspension of particles when the pump intake is close to the settled solids layer. Filtration techniques that use membranes or partially permeable barriers retain larger particles, permitting smaller particles to permeate. However, filters, including dead-end filtration, are prone to clogging and caking, operate at elevated pressures due to minimal void volume, and increase in pressure during operations, which require more control systems. Therefore, the need for high throughput particle separation techniques that operate with modest pressure drops persists. A novel mesofluidic separator presents the opportunity to effectively and efficiently accelerate the waste cleanup mission. The separator separates large particles from process streams across a broad range of particle sizes and has no moving parts or media to replace, regenerate, or clean. This separator design has an unusually large void volume, permitting operation at much higher flow rates (and lower pressures) than traditional filtration (e.g., dead-end filtration). Industrial-scale flow rates have been demonstrated. In performance testing, mesofluidic separators operate at might flow rates (>90 gpm (0.0006 m{sup 3}/s) in piping 3 inches (0.08 m) in diameter; Re>10{sup 5}), with modest pressure drop (∼25 psi (170 KPa) in testing). In complex, aggregating waste simulants, the separator loses <25% of flow projected over months without back pulsing or chemical cleaning. Mesofluidic separation presents infrastructure advantages, reduces risk, and provides mission impact. Infrastructure advantages include implementation within existing transfer systems, plug and play without facility modifications to safety systems, and operation at low pressures. The separator is flexible in location, may be positioned within or outside of waste tanks, and may replace or augment dead-end and cross-flow filters. Mesofluidic separation reduces risk by minimizing waste (no media to replace or regenerate and no cleaning chemicals to handle and dispose) and by minimizing filter change-out consistent with as low as reasonably achievable (ALARA) exposure to workers. The potential mission impact of these separators is substantial. The separator has potential to support, simplify, and accelerate in-farm transfers and waste feed delivery. Furthermore, the separator can free up settling and holding tanks in the Direct Feed Low-Activity Waste (DFLAW) mission by reducing or eliminating post-transfer settling and wait times with the potential to free up 1 Mgal (4000 m{sup 3}) of double-shell tank space. This paper quantitatively compares mesofluidic separation to dead-end filtration, discusses scale-up results, and considers the separator's potential to efficiently and effectively reduce the long-term environmental ability of particulate-rich nuclear wastes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hybrid Analytics Solution to Improve Coal Power Plant Operations

This project focused on developing advanced methods for thermal performance monitoring of a coal-fueled power plant. The specific goal was to develop and demonstrate a new thermal performance monitoring approach using a hybrid model that integrates a physics-based heat balance model with a machine learning-based pattern recognition model. The hybrid model enables increased accuracy and scope of the thermal analysis and an improved ability to monitor and detect changes in plant operation. This new approach takes full advantage of the individual model capabilities and creates an important new set of capabilities not previously possible using the two types of models separately. Using the heat balance model, a rich set of derived parameters (virtual sensors) are calculated from the measured plant operating data at each time point. The combined measured and derived data values are used by machine learning algorithms to create pattern recognition models over the range of normal unit operation. To create the monitoring models, historical data from normal operation of the plant is first processed by the heat balance model to compute the derived parameter data. The result is a greatly expanded set of normal operating data that can be used as input to create the pattern recognition model. Once the models are calibrated for normal operation, the hybrid model is suitable for use in continuous online monitoring. During online monitoring, new plant operating data is processed first by the heat balance model and then by the pattern recognition model. Results from the pattern recognition model quantify the deviation of each measured or derived parameter from its expected value in normal operation. The hybrid models can detect abnormal changes in plant operating data with very high accuracy and sensitivity. When abnormal behavior is detected, alerts are generated automatically for evaluation by the plant monitoring staff. The new hybrid solution product was developed and verified in the performance of the project. The hybrid solution was tested first in a simulation environment that mimicked the plant data systems and infrastructure used by U.S. power generating plants and utilities. The hybrid solution was then deployed for real-time, online monitoring of an operating coal-fueled power plant at a field test site. Field testing demonstrated that all hybrid solution development objectives were accomplished. The project work was based on combining the capabilities of two existing software products to create the new hybrid solution product. One of these was the existing MapEx® heat balance product and the other was the existing SureSense® advanced pattern recognition product. Each of these separate products was assessed to be at a Technology Readiness Level (TRL) of 9 at the start of the effort. The hybrid solution product was assessed to be at a TRL of 2 at the start of the project based on early feasibility work by the project team. At completion of the field testing performed in the project, the hybrid solution product was assessed to be at a TRL of 7. The project team expects that the hybrid solution product will be deployed commercially and will achieve a TRL of 9 within one year after completion of the project.

01 COAL, LIGNITE, AND PEAT↗

Benchmark Specifications for TREAT Tests M5, M6, and M7

Detailed information describing three TREAT tests performed on metallic fuels has been collected and organized for use as a benchmark in evaluating the performance of metallic fuel models and codes. The tests, designated M5, M6, and M7, subjected EBR-II-irradiated fuel pins to a single type of overpower transient (at prototypical conditions with full coolant flow and an exponential power rise on an 8 second period) in flowing sodium loops. Six fuel pins were tested; five were ternary (U-19Pu-10Zr) alloy fuel clad in D9 with burnup ranging from 0.8 to 9.8 at. %, and one was binary alloy fuel (U-10Zr) clad in HT9 with 2.9 at. % burnup. The information gathered from the test records is expected to be useful for pre-transient characterization of the irradiated fuel pins as well as the transient analysis of the metallic fuel when subjected to severe accident conditions. This report presents benchmark specifications for the M5, M6, and M7 TREAT tests, identifies where primary sources of benchmark-related information can be found, and includes background information to help a user of the data understand their applicability and limitations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Diesel Oxidation Catalyst Performance with Biodiesel Formulations

Biodiesel (i.e., mono-alkyl esters of long chain fatty acids derived from vegetable oils and animal fats) is a renewable diesel fuel providing life-cycle greenhouse gas emission reductions relative to petroleum-derived diesel. With the expectation that there would be widespread use of biodiesel as a substitute for ultra-low sulfur diesel (ULSD), there have been many studies looking into the effects of biodiesel on engine and aftertreatment, particularly its compatibility to the current aftertreatment technologies. The objective of this study was to generate experimental data to measure the effectiveness of a current technology diesel oxidation catalysts (DOC) to oxidize soy-based biodiesel at various blend levels with ULSD. Biodiesel blends from 0 to 100% were evaluated on an engine using a conventional DOC. In the steady-state performance test where fuel dosing rate was increased at fixed DOC inlet temperature, B20 performed similarly to ULSD at the lowest flow rate or exhaust temperature over 340 degrees C for medium and high flows. B50 blends performed nearly as well under most conditions. Higher blends exhibited reduced thermal efficiency and DOC outlet temperature with increasing dosing rate under most conditions and required exhaust temperatures over 400 degrees C to achieve or nearly achieve performance similar to ULSD. In the steady-state light of test where fuel dosing rate is fixed but exhaust temperature is increased incrementally, B20 generally performed similarly to ULSD at the highest inlet temperature, with only minor deficiencies at lower temperatures. Higher blends exhibited lower thermal efficiency and did not achieve as high DOC outlet temperatures. In the transient light-off test light-off temperature for ULSD was typically less than 225 degrees C, while for B100 it ranged from 290 degrees C to 330 degrees C. Based on the data set, it can be concluded that biodiesel fuels have a higher light-off temperature primarily because of their higher boiling points, with a minor secondary impact of their lower energy content.

ADVANCED PROPULSION SYSTEMS,BIOMASS FUELS↗

Impact of Porous Transport Layer Morphology on the Performance of Proton Exchange Membrane Water Electrolyzers with Ultra-Low Iridium Loadings

Reducing Ir loadings in proton exchange membrane water electrolyzer anodes is critical for lowering capital expenses. Loading reduction could be achieved by improving the Ir activity via doping/alloying and/or the development of advanced microstructures. However, the anode porous transport layer (PTL) is a comparatively simple component whose properties also impact Ir utilization. Therefore, well-designed PTLs may also enable reduced Ir loadings. In this work, we survey eight PTLs from various manufacturers to observe their impact on cell performance at low (0.4 mg Ir cm -2 ) and ultralow (0.1 mg Ir cm -2 ) Ir loadings. The PTLs were characterized by their microstructural properties, including porosity, particle size distribution, and pore size distribution. Electrochemical cell performance was correlated to PTL morphology, and it was found that PTLs with lower porosities and smaller particle and pore radii enabled good performance even at ultralow Ir loadings. 1000-h durability testing indicated that using lower porosity PTLs can significantly improve durability behavior. A runaway voltage phenomenon was observed during durability testing of cells with ultralow Ir loadings, which was caused by increases in both anode and cathode overpotentials. Furthermore, we observed that the beginning of test performance of 0.1 mg Ir cm -2 cells correlates to the 1000-h degradation rates of 0.4 mg Ir cm -2 cells, suggesting that for the Ir catalyst used in this work, short-term testing at ultralow loadings can be used as an indicator of long-term degradation at higher loadings.

08 HYDROGEN↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multilateral Testing Workshop on Relocatable Portal Monitors

The procurement and deployment of radiation detection equipment is a multi-faceted challenge across the globe. Knowledge sharing of the testing methods used to evaluate equipment for deployment scenarios helps improve the understanding of deployed systems by the global community. The United States Department of Energy’s Nuclear Smuggling Detection and Deterrence Office (NSDD) performed a series of characterization measurements in 2019, focused on radiation detection systems that could function as relocatable portal monitors. The capstone activity for this project was a multilateral and cross-disciplinary workshop demonstrating, performing, and refining the techniques used in the characterization measurements with International Atomic Energy Agency (IAEA) and global partners. A group of technical experts including representatives from nine countries, the IAEA, and NSDD gathered at Sandia National Laboratories in Albuquerque, NM during September of 2019 for the Operational and Performance Testing and Evaluation of Relocatable Portals Workshop. Over the course of a week, the group discussed the necessity for and process of developing operational and performance requirements, challenges related to deploying radiation detection systems for the countries in attendance, use cases for deploying relocatable radiation detection equipment, and considerations related to testing equipment for appropriate deployment scenarios. All participants were given the opportunity to have hands-on experience with eleven relocatable systems in executing a limited scope characterization test comprised of six test scenarios. At the conclusion of testing, participants reviewed and presented their findings, and the group as a whole compared and contrasted their experiences. Suggested revisions to the test methods and ideas for further collaborations were discussed. This report discusses the logistical and planning considerations for bringing together experts across disciplines in a multilateral workshop on testing of radiation detectors, as well as presenting the testing methods performed, results, and paths forward. Success of workshops related to technical knowledge transfer and improvement of test methods is key to global technical and scientific support of radiation detection deployments.

Erchinger, Jennifer L.↗

Medium-temperature phase change material integration in domestic heat pump water heaters for improved thermal energy storage

In this review, we examine state-of-the-art developments in integrating phase change materials (PCMs) for thermal energy storage (TES) in domestic heat pump water heaters (HPWHs). The component design optimization and control optimization of HPWHs and TES are reviewed for insight into improving the thermal capacity and efficiency of a PCM-integrated HPWH. The state-of-the-art review is categorized by the stage of development of the PCM for deployment in HPWHs. To select appropriate PCMs for HPWHs, a six-factor down-selection process is used to determine the best material(s) for integration in HPWHs with appropriate heat exchanger design. Ultimately, food-grade PCMs appear to be the best candidate for integration of TES in domestic HPWHs because they are nontoxic, highly cyclable, and have heat transfer properties accommodable to water heating when integrated in a manner to overcome the thermal conductivity limitations of the material. A key parameter of water heating performance is thermal heating power of the PCM component, which is not often reported. Many studies report significant improvement in capacity and efficiency. Furthermore, many performance metrics are identified from the literature to quantify the system performance, but agreement across studies is not found. Unified energy factor and first hour rating performance tests are required for commercially available HPWHs, and these performance metrics could homogenize the literature. Ultimately, we find that select PCMs are ready for deployment with HPWHs for performance improvement, and component design and control optimizations are new avenues of research and development required for a commercially viable PCM-integrated HPWH system.

25 ENERGY STORAGE↗

ION Validation of Transformational CO2 Capture Solvent Technology with Revolutionary Stability: “Project Apollo”

This final report presents all the work and tests performed during ION’s carbon dioxide (CO2) capture pilot test campaign at the 0.6 MWe scale in the Pilot Solvent Test Unit (PSTU) at the National Carbon Capture Center (NCCC): “Validation of Transformational CO2 Capture Solvent Technology with Revolutionary Stability,” referred to as the “Apollo” Project (DE-FE0031727).

Meuleman, Erik↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CMS Outer Tracker Module QA

The High Luminosity Large Hadron Collider is a planned upgrade to the LHC that will allow it to take up to 7 times as much data. Upgrades to all detector systems, including the Outer Tracker, are necessary to allow them to handle the increased radiation and pileup. Fermilab has been tasked with assembling modules for the Outer Tracker system. This presentation discusses the QA tests performed on these modules and the integration procedure required to ensure all modules work in sync. The QA tests include sensor IV curves, MaPSA testing, visual inspection, skeleton testing, and module testing. There are additional tests that can only be performed on integrated modules that are working in sync, and developing an understanding of the timing and latency of the modules is necessary to perform this synchronization.

Hobbeheydar, Samuel [Fermilab; Carnegie Mellon U. ↗

CMS Outer Tracker Module QA

The High Luminosity Large Hadron Collider is a planned upgrade to the LHC that will allow it to take up to 7 times as much data. Upgrades to all detector systems, including the Outer Tracker, are necessary to allow them to handle the increased radiation and pileup. Fermilab has been tasked with assembling modules for the Outer Tracker system. This presentation discusses the QA tests performed on these modules and the integration procedure required to ensure all modules work in sync. The QA tests include sensor IV curves, MaPSA testing, visual inspection, skeleton testing, and module testing. There are additional tests that can only be performed on integrated modules that are working in sync, and developing an understanding of the timing and latency of the modules is necessary to perform this synchronization.

Hobbeheydar, Samuel [Fermilab; Carnegie Mellon U. ↗

Flexible tape-drive target system for secondary high-intensity laser-driven sources

Here, we present the development of a flexible tape-drive target system to generate and control secondary high-intensity laser-plasma sources. Its adjustable design permits the generation of relativistic MeV particles and x rays at high-intensity (i.e., ≥1 × 10 18 W cm —2 ) laser facilities, at high repetition rates (>1 Hz). The compact and robust structure shows good mechanical stability and a high target placement accuracy (<4 μm RMS). Its compact and flexible design allows for mounting in both the horizontal and vertical planes, which makes it practical for use in cluttered laser-plasma experimental setups. The design permits ~170° of access on the laser-driver side and 120° of diagnostic access at the rear. A range of adapted apertures have been designed and tested to be easily implemented to the targetry system. The design and performance testing of the tape-drive system in the context of two experiments performed at the COMET laser facility at the Lawrence Livermore National Laboratory and at the Advanced Lasers and Extreme Photonics (ALEPH) facility at Colorado State University are discussed. Experimental data showing that the designed prototype is also able to both generate and focus high-intensity laser-driven protons at high repetition rates are also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Iterative methods in GPU-resident linear solvers for nonlinear constrained optimization

Linear solvers are major computational bottlenecks in a wide range of decision support and optimization computations. The challenges become even more pronounced on heterogeneous hardware, where traditional sparse numerical linear algebra methods are often inefficient. For example, methods for solving ill-conditioned linear systems have relied on conditional branching, which degrades performance on hardware accelerators such as graphical processing units (GPUs). To improve the efficiency of solving ill-conditioned systems, our computational strategy separates computations that are efficient on GPUs from those that need to run on traditional central processing units (CPUs). Our strategy maximizes the reuse of expensive CPU computations. Iterative methods, which thus far have not been broadly used for ill-conditioned linear systems, play an important role in our approach. In particular, we extend ideas from Arioli et al., (2007) to implement iterative refinement using inexact LU factors and flexible generalized minimal residual (FGMRES), with the aim of efficient performance on GPUs. In conclusion, we focus on solutions that are effective within broader application contexts, and discuss how early performance tests could be improved to be more predictive of the performance in a realistic environment.

97 MATHEMATICS AND COMPUTING↗

Utah FORGE: Well 16A(78)-32 and 16B(78)-32 Stimulation Production Logging Tests

These are production logging tests (PLT) results from Halliburton collected during the nine hour circulation test performed at Utah FORGE on April 27th, 2024. The circulation test involved injecting into well 16A(78)-32 and producing out of well 16B(78)-32) and was carried out after the fracturing of both of those wells. Data attached here includes raw and processed PLT logs from both wells, as well as technical reports summarizing the data collection and results.

15 GEOTHERMAL ENERGY↗

A Semi-Empirical Correlation for the Onset of Density Wave Oscillations in a Helical Coil Steam Generator

NuScale Power has completed full length helical coil steam generator (HCSG) tests at SIET Laboratories in Piacenza, Italy. The test program included an investigation of the onset and evolution of density wave oscillations (DWO). This paper describes the mechanisms leading to the onset of DWO as inferred from tests performed in the full-height TF-2 counter-flow test facility. This research supports the concept that the onset of DWO is caused by liquid bridging inside the boiling length of the tubes. Using a separate cylinders approximation, a DWO onset correlation is obtained by performing a steady-state momentum balance on the density front created by liquid bridging. This yields a momentum balance equation in terms of a set of dimensionless superficial velocities, a corresponding dimensionless pressure drop term and an average void fraction. Envelope theory is then used to obtain a critical void fraction which is substituted into the dimensionless momentum balance to obtain a DWO onset correlation similar to the Wallis counter-current flooding correlation. A comparison of the DWO onset correlation to the TF-2 DWO experimental data is presented and shows excellent agreement when the average equilibrium vapor quality is greater than 0.2.

Density Wave Oscillations, Helical Coil Steam Gene↗

Heat load measurements for the PIP-II pHB650 cryomodule

This study presents a brief overview of the 1st and 2nd phases and an in-depth analysis of the 3rd phase heat load testing performed on the pHB650 (prototype High Beta 650 MHz) cryomodule at PIP2IT (PIP-II Injector Test Facility), with a focus on both the results and the methodological advancements that have improved testing efficiency and accuracy. A key challenge identified in the testing campaign is the higher-than-expected heat loads observed in the first PIP-II (Proton Improvement Plan II) prototype cryomodules (pSSR1 and pHB650) tested at PIP2IT. Elevated heat loads are concerning given the fixed capacity of the PIP-II cryoplant that is currently being installed at Fermilab. However, understanding the sources of these elevated heat loads offers a critical opportunity to implement effective heat load mitigations on upcoming PIP-II cryomodules to stay within the available capacity of the PIP-II cryoplant. The study includes a summary of test results, descriptions of measurement procedures, and key observations on parameters directly and indirectly related to heat load measurements. Direct observations include measured heat loads and the effectiveness of JT heat exchanger under varying conditions, while indirect observation analyze factors such as the temperature distribution on the two-phase pipe and relief piping under varying conditions. Thermal acoustic oscillations (TAO) were identified during testing, which was mitigated by replacing the original G10 stem with a stainless steel stem equipped with wipers for the cryomodule cooldown valve. A major innovation during pHB650 Phase 3 testing was the development of an automated Python script to streamline data acquisition, analysis, and reporting of heat load results. This script automatically retrieved data from ACNET (Accelerator Control Network), performed heat load calculations, and generated detailed reports featuring plots and tables. This advancement significantly reduced manual labor and enhanced the thoroughness of data analysis compared to earlier campaigns. The heat load test reports were promptly uploaded to the electronic logbook shortly after each test, enabling rapid feedback and collaboration between the SRF and cryogenic teams. The heat load measurements included various components: HTTS (high-temperature thermal shield), LTTS (low-temperature thermal shield), 2K isothermal and non-isothermal heat loads. Results were recorded both within the cryomodule and between the bayonet can supply and return. Measurements were conducted under different operating conditions such as "standard", "linac", and "simulated dynamic". Additionally, HTTS and LTTS heat loads were calculated in real time, allowing for the tracking of thermal stability and identification of changes during testing, both in steady-state and transient conditions. The results of this testing campaign not only provide valuable insights into the performance of the pHB650 cryomodule but also highlight best practices and lessons learned that will inform future cryomodule testing at PIP2IT. These include adopting automated tools for data analysis, refining real-time measurement capabilities, and emphasizing detailed pre-test planning. The framework established in this campaign aims to set an improved standard for cryomodule testing and heat load reporting in future cryomodule test campaigns.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗