Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “parametric study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Parametric Study of SANSMIC Input and Resulting Impact on Predicted Cavern Geometry and Leaching Efficiency

The Sandia Solution Mining Code (SANSMIC) has been used for many years to examine the development of salt cavern geometry, both in a confirmatory manner with comparisons made to real-world sonar data and in a predictive manner when updated sonar data are not available. SANSMIC models require some modeling choices in order to incorporate real-world data. Key modeling choices include the vertical resolution of cavern geometry to implement, as well as how to incorporate daily raw water injection data into the SANSMIC model. This report documents five studies that address the impact of the modeling choices on the predicted cavern geometries and calculated leaching efficiencies. In most cases, hypothetical cylindrical initial cavern geometries are used to provide a common baseline against which to test the systematic variation of input variables including cavern radius, oil-brine-interface (OBI) depth, vertical cell size, raw water injection rate, raw water injection duration, workover time, and number of leaching stages. The use of smaller cell sizes is recommended moving forward to provide a better one-to-one relationship between sonar data and the modeled cavern. A new methodology for incorporating raw water injection data is also recommended, in order to more closely model real-world injection and workover times. Overall, the systematic studies performed here have increased our confidence in previous SANSMIC model results, as well future use of the code for predicting leaching effects on cavern geometries. Some minor changes to modeling choices are recommended, which can easily be applied with the version of SANSMIC currently under development.

42 ENGINEERING↗

Parametric Study of Factors that Affect Calculated Dose from TRISO Fueled Microreactor Transportation Accident

Microreactors are very small nuclear reactors with a power output up to 50 megawatts electric (MWe) which also meet the standards of an “advanced nuclear reactor.” Microreactors are designed to be factory-built, modular in nature, and may be transportable. These compact small-sized reactors in some design configurations are small enough to be transported by truck which could help solve certain energy challenges. This report refers to these reactors as transportable microreactors or transportable nuclear power plants (TNPPs). Transportable microreactors are being considered for a wide range of independent operation applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Theoretical Analysis of Fractional Viscoelastic Flow in Circular Pipes: Parametric Study

Pipe flow is one of the most commonly used models to describe fluid dynamics. The concept of fractional derivative has been recently found very useful and much more accurate in predicting dynamics of viscoelastic fluids compared with classic models. In this paper, we capitalize on our previous study and consider space-time dynamics of flow velocity and stress for fractional Maxwell, Zener, and Burgers models. We demonstrate that the behavior of these quantities becomes much more complex (compared to integer-order classical models) when adjusting fractional order and elastic parameters. We investigate mutual influence of fractional orders and consider their limiting value combinations. Finally, we show that the models developed can be reduced to classical ones when appropriate fractional orders are set.

Gritsenko, Dmitry (ORCID:0000000248181512)↗

Parametric Study of Panel PCM–Air Heat Exchanger Designs

Heat exchangers, devices for the transfer of heat between two or more working fluids, are extensively used in cooling applications and heating applications. Heat exchangers in buildings are typically components of space-conditioning systems, as well as of water-heating applications. Heat exchangers are also sometimes used in applications that require storage and release of energy at specific times. Phase change materials (PCMs) enhance these heat-exchange processes, given their ability to melt and solidify at a fixed range of temperatures, absorbing or releasing significant amounts of latent heat. Five different configurations of PCM–air heat exchangers for thermal control in buildings are analyzed in this work. The heat exchangers were fitted with PCM encapsulated in plastic and composite pouches of various shapes, and packaged in stackable panel layers. Three-dimensional computational fluid dynamics (CFD) modeling of coupled incompressible fluid and conjugate heat transfer were performed on the designs. The phase change process was numerically modelled using the apparent heat capacity method. Steady-state CFD simulations provided quantification of pressure drop as a function of air flow velocity. Transient simulation results describe the thermal evolution of PCM in the pouches, helping to determine the best performing configuration with respect to total thermal charging time.

10 SYNTHETIC FUELS↗

A Parametric Study of the SASI Comparing General Relativistic and Nonrelativistic Treatments

We present numerical results from a parameter study of the standing accretion shock instability (SASI), investigating the impact of general relativity (GR) on the dynamics. Using GR hydrodynamics with GR gravity, and nonrelativistic (NR) hydrodynamics with Newtonian gravity, in an idealized model setting, we vary the initial radius of the shock, and by varying its mass and radius in concert, the proto-neutron star compactness. We investigate four compactnesses expected in a post-bounce core-collapse supernova (CCSN). We find that GR leads to a longer SASI oscillation period, with ratios between the GR and NR cases as large as 1.29 for the highest-compactness suite. We also find that GR leads to a slower SASI growth rate, with ratios between the GR and NR cases as low as 0.47 for the highest-compactness suite. We discuss implications of our results for CCSN simulations.

79 ASTRONOMY AND ASTROPHYSICS↗