Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “paralleled converters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Design of a Low-Light-Level Image Sensor with On-Chip Sigma-Delta Analog-to- Digital Conversion

The design and projected performance of a low-light-level active-pixel-sensor (APS) chip with semi-parallel analog-to-digital (A/D) conversion is presented. The individual elements have been fabricated and tested using MOSIS* 2 micrometer CMOS technology, although the integrated system has not yet been fabricated. The imager consists of a 128 x 128 array of active pixels at a 50 micrometer pitch. Each column of pixels shares a 10-bit A/D converter based on first-order oversampled sigma-delta (Sigma-Delta) modulation. The 10-bit outputs of each converter are multiplexed and read out through a single set of outputs. A semi-parallel architecture is chosen to achieve 30 frames/second operation even at low light levels. The sensor is designed for less than 12 e^- rms noise performance.

Mendis, Sunetra K.↗

Recent progress in hybrid mode thermionic converter development

Thermionic research has been conducted to investigate a hybrid-mode thermionic converter as a candidate for reducing the barrier index. The hybrid-mode thermionic converter is designed to operate in a combination ignited mode and unignited mode by using a series of parallel grooves in the emitter. The emitter material is molybdenum and the non-grooved land area is thinly coated with rhenium metal. When the emitter is exposed to cesium vapor, as it is during the converter operation, the rhenium-coated land area achieves a lower work function than the grooved molybdenum surface by as much as 0.5 eV. The low work function land area provides a major portion of electron emission, and the high work function grooved area provides cesium ions required for efficient transport of electrons generated in adjacent land areas to the collector. Experimental results obtained from two different converters and a numerical analysis of converter characteristics are presented in this paper.

Shimada, K.↗

Eight microprocessor-based instrument data systems in the Galileo Orbiter spacecraft

Instrument data systems consist of a microprocessor, 3K bytes of Read Only Memory and 3K bytes of Random Access Memory. It interfaces with the spacecraft data bus through an isolated user interface with a direct memory access bus adaptor, and/or parallel data from instrument devices such as registers, buffers, analog to digital converters, multiplexers, and solid state sensors. These data systems support the spacecraft hardware and software communication protocol, decode and process instrument commands, generate continuous instrument operating modes, control the instrument mechanisms, acquire, process, format, and output instrument science data.

Barry, R. C.↗

[Activities of Bay Area Research Corporation]

During the final year of this effort the HALFSHEL code was converted to work on a fast single processor workstation from it s parallel configuration. This was done because NASA Ames NAS facility stopped supporting space science and we no longer had access to parallel computer time. The single processor version of HALFSHEL was upgraded to address low density cells by using a a 3-D SOR solver to solve the equation Delta central dot E = 0. We then upgraded the ionospheric load packages to provide a multiple species load of the ionosphere out to 1.4 Rm. With these new tools we began to perform a series of simulations to address the major topic of this research effort; determining the loss rate of O(sup +) and O2(sup +) from Mars. The simulations used the nominal Parker spiral field and in one case used a field perpendicular to the solar wind flow. The simulations were performed for three different solar EUV fluxes consistent with the different solar evolutionary states believed to exist before today. The 1 EUV case is the nominal flux of today. The 3 EUV flux is called Epoch 2 and has three times the flux of todays. The 6 EUV case is Epoch 3 and has 6 times the EUV flux of today.

Source record↗

Dynamic Phasor Modeling of Multi-Converter Systems

Generalized form of Dynamic Phasor (DP)-based modeling of multi-converter systems containing high order harmonics has not been proposed in the literature yet due to the complexity and large number of variables that should be included in the model. In this work a generalized form of a system-level model comprising high number of single-phase converters is presented. The proposed method can be applied to any number of single-phase voltage source converters (VSIs). Test cases of this modeling method containing 5 to 100 parallel connected single-phase voltage source inverters are modeled and simulation times are recorded. The results of the proposed method are compared and validated with conventional average models as well as detailed switching models. A systematic approach for comparing the accuracy and timestep between dynamic phasor modeling method and detailed switching model is illustrated. Advantage of DP models over conventional average models for stability assessment are also discussed at the end of the paper.

Xue, Yaosuo↗

Solar energy converter using surface plasma waves

Sunlight is dispersed over a diffraction grating formed on the surface of a conducting film on a substrate. The angular dispersion controls the effective grating period so that a matching spectrum of surface plasmons is excited for parallel processing on the conducting film. The resulting surface plasmons carry energy to an array of inelastic tunnel diodes. This solar energy converter does not require different materials for each frequency band, and sunlight is directly converted to electricity in an efficient manner by extracting more energy from the more energetic photons.

Anderson, L. M.↗

Semiconductor topologies and devices for soft starting and active fault protection of power converters

Various examples are provided related to semiconductor topologies and devices that can be used for soft starting and active fault protection of power converters. In one example, an active switch device includes an active switch having a gating control input; and a thyristor having a gating control input. The thyristor is coupled in parallel with the active switch. The active switch can be an IGBT, MOSFET, or other appropriate device. In another example, a power converter can include the active switch devices and switching control circuitry coupled to gating control inputs of the active switch devices.

Beddingfield, Richard B.↗

Experimental and simulation study of target biasing effects on plasma transport in linear plasma device MPS-LD

Linear plasma devices (LPDs) are important experimental platforms for investigating plasma–material interactions (PMI). In PMI experiments, it has been found that applying a target bias not only effectively modifies the incident ion energy, but also induces significant changes in the electron density and electron temperature, whereby the evolution of these plasma parameters is primarily governed by plasma transport processes. However, at present, the physical process and mechanism underlying such bias-induced variations remain unclear. In this work, biasing experiments under argon plasma discharge conditions were first carried out on the MPS-LD device. For the corresponding experiments, an electric potential model was newly developed based on the BOUT++ LPD module, enabling self-consistent simulations of plasma transport under biased conditions. Numerical simulations were then performed to reproduce the experimental results and to validate the accuracy of the proposed model. Finally, by combining experimental measurements with numerical simulations, a bias-voltage scan was performed to investigate how the electron density and electron temperature vary with the bias voltage (U bias ). The results show that applying negative bias decreases the target electron density (n e,T ) while increasing the target electron temperature (T e,T ). In contrast, positive bias increases both n e,T and T e,T ; however, at high positive bias, n e,T first reaches a maximum and subsequently decreases with further increases in U bias . The underlying physical mechanisms are analyzed using particle flux, momentum, and energy conservation. It indicates that the applied bias regulates the parallel electric field, thereby changing ion and electron velocities, and consequently affecting the electron density. At high positive bias, the ion velocity is further influenced by ion viscosity, leading to the reversal in n e,T . Meanwhile, the enhanced parallel electric field drives stronger currents, significantly increasing ion–electron frictional work and converting the input bias power into electron energy, which raises the electron temperature. In conclusion, these results contribute to a deeper understanding of the effects and mechanisms of biasing on plasma transport in the MPS-LD device.

BOUT++ simulation↗

NASA Pioneer: Venus reverse playback telemetry program TR 78-2

During the entry of the Pioneer Venus Atmospheric Probes into the Venus atmosphere, there were several events (RF blackout and data rate changes) which caused the ground receiving equipment to lose lock on the signal. This caused periods of data loss immediately following each one of these disturbing events which lasted until all the ground receiving units (receiver, subcarrier demodulator, symbol synchronizer, and sequential decoder) acquired lock once more. A scheme to recover these data by off-line data processing was implemented. This scheme consisted of receiving the S band signals from the probes with an open loop reciever (requiring no lock up on the signal) in parallel with the closed loop receivers of the real time receiving equipment, down converting the signals to baseband, and recording them on an analog recorder. The off-line processing consisted of playing the analog recording in the reverse direction (starting with the end of the tape) up, converting the signal to S-band, feeding the signal into the "real time" receiving system and recording on digital tape, the soft decisions from the symbol synchronizer.

Modestino, J. W.↗

Automated Vectorization of Decision-Based Algorithms

Virtually all existing vectorization algorithms are designed to only analyze the numeric properties of an algorithm and distribute those elements across multiple processors. This advances the state of the practice because it is the only known system, at the time of this reporting, that takes high-level statements and analyzes them for their decision properties and converts them to a form that allows them to automatically be executed in parallel. The software takes a high-level source program that describes a complex decision- based condition and rewrites it as a disjunctive set of component Boolean relations that can then be executed in parallel. This is important because parallel architectures are becoming more commonplace in conventional systems and they have always been present in NASA flight systems. This technology allows one to take existing condition-based code and automatically vectorize it so it naturally decomposes across parallel architectures.

James, Mark↗

Current-Source Solid-State DC Transformer Integrating LVDC Microgrid, Energy Storage, and Renewable Energy Into MVDC Grid

Solid-state DC transformer to integrate low-voltage DC (LVDC) microgrid, wind turbine (WT) generator, photovoltaic (PV), and energy storage (ES) into medium-voltage (MV) direct-current (MVDC) distribution grids is attractive. This paper proposes current-source DC solid-state transformer (SST) for MVDC collection system in WT, PV, and ES farms or as an interface between the MVDC grid and the LVDC microgrid. Compared to conventional current-source converter (CSC) based SSTs, a switch reduction scheme on reverse-blocking device bridges is proposed to reduce device count and the number of devices on the DC-link current path. Importantly, the proposed switch reduction scheme is generic and can be applied to the DC ports of DC-AC, AC-DC, or DC-DC hard-switching or soft-switching CSC-based SSTs. Based on this scheme, the proposed current-source DC SSTs are derived, which have reduced electrolytic-capacitor-less DC-link. The proposed DC SSTs also achieve single-stage isolated DC-DC or DC-AC conversion, full-range zero-voltage switching (ZVS) for main switches, zero-current switching (ZCS) for resonant switches, and controlled dv/dt. The proposed DC SSTs, operating principles, predictive control method, the ZVS, and the controlled dv/dt under voltage buck-boost ranges are verified with MV simulations and an experimental prototype based on SiC MOSFETs, diodes, and a nanocrystalline transformer.

14 SOLAR ENERGY↗

CAZyme domain architectures suggest fine-scale functional differentiation among anaerobic fungi and bacteria during lignocellulose conversion to volatile fatty acids

Anaerobic fermentation with microbial communities (microbiomes) is an emerging platform for conversion of lignocellulosic biomass to biofuels and bioproducts. The process relies on diverse anaerobic microbes that interact to deconstruct and convert lignocellulosic biomass into a range of products, such as volatile fatty acids (VFAs), which can be achieved by arresting methanogenesis during fermentation. However, defining the distinct functional roles played by various fungi and bacteria during anaerobic biodegradation remains poorly understood. Here, we performed parallel enrichment experiments from cow faeces, goat faeces, and anaerobic digester sludge, selecting for fungal or bacterial dominated communities that convert sorghum biomass into VFAs. Subsequently we reconstructed metabolic networks across these enrichments based on recovered bacterial metagenome-assembled genomes (MAGs) and fungal isolate genomes and profiled their metabolic activity using metatranscriptomics to identify potential functional niches. Our findings implicate diverse bacteria affiliated with the Bacteroidales and Lachnospiraceae in the direct conversion of lignocellulosic biomass to propionate and butyrate, respectively, whereas Neocallimastix-dominated fungal enrichments converted lignocellulose to lactate, acetate and formate. Analysis of carbohydrate-active enzymes (CAZymes) revealed fine-scale differences between microbes that expressed unique multi-functional enzymes linking two or more CAZymes together with distinct carbohydrate binding motifs, implicating lignocellulose structure as a key driver of selection and niche differentiation. Most of these multi-functional enzymes localized complementary degradation functions together, likely conferring synergistic degradation effects within and between microbiome members. We anticipate that these findings will help inform efforts to develop synthetic microbiomes with tailored functionality for low-cost conversion of lignocellulosic biomass to fuels and bio-based chemicals.

Lawson, Christopher E [University of Toronto;]↗

Photocapacitive image converter

An apparatus for converting a radiant energy image into corresponding electrical signals including an image converter is described. The image converter includes a substrate of semiconductor material, an insulating layer on the front surface of the substrate, and an electrical contact on the back surface of the substrate. A first series of parallel transparent conductive stripes is on the insulating layer with a processing circuit connected to each of the conductive stripes for detecting the modulated voltages generated thereon. In a first embodiment of the invention, a modulated light stripe perpendicular to the conductive stripes scans the image converter. In a second embodiment a second insulating layer is deposited over the conductive stripes and a second series of parallel transparent conductive stripes perpendicular to the first series is on the second insulating layer. A different frequency current signal is applied to each of the second series of conductive stripes and a modulated image is applied to the image converter.

Miller, W. E.↗

Integrating Flow Imaging Analysis and Single-Particle ICP-TOFMS for Comprehensive Micro- and Nanoplastic Characterization

Flow imaging analysis (FIA), provides composition-agnostic morphological characterization. These measurements of particle size and shape are valuable to mass-based analysis, such as single particle inductively coupled plasma time-of-flight mass spectrometry (sp-ICP-TOFMS), which provides quantitative data on elements within particles. Using these two methods together enables informed use of geometric assumptions required by sp-ICP-TOFMS, as particle mass is typically converted to a particle diameter using assumed-spherical geometry. To validate this concept, parallel measurements to determine particle diameters were performed by FIA and sp-ICP-TOFMS on four particle suspensions: 300 nm polystyrene Eu-doped nanoparticles, 1 μm Fe-rich beads, 3 μm four element calibration polystyrene beads and 5 μm polystyrene beads. The Fe-particles obtained the highest percent difference from the manufacturer’s nominal diameter, as the mean diameter obtained by FIA was overestimated by 21% and sp-ICP-TOFMS underestimated the mean diameter by 20.7%. Two types of particles were selected to test the effect of varying the particle number concentrations (PNC) on sizing accuracy, and both methods accurately sized each particle population at the PNC expected. Single particle analysis of carbon has continued to be a popular research topic, with direct applications to environmental pollutants in terms of nano- and micro- plastics. Real-world plastic particles were studied, and FIA’s measured circularity values demonstrated that the particles deviated from spherical geometries, therefore sp-ICP-TOFMS data should be interpreted as mass-based rather than size-based. Combining these techniques enables improved interpretation of particle populations and evaluation of particle sizes.

Szakas, Sarah [ORNL] (ORCID:0000000241332197)↗

High data volume and transfer rate techniques used at NASA's image processing facility

Data storage and transfer operations at a new image processing facility are described. The equipment includes high density digital magnetic tape drives and specially designed controllers to provide an interface between the tape drives and computerized image processing systems. The controller performs the functions necessary to convert the continuous serial data stream from the tape drive to a word-parallel blocked data stream which then goes to the computer-based system. With regard to the tape packing density, 1.8 times 10 to the tenth data bits are stored on a reel of one-inch tape. System components and their operation are surveyed, and studies on advanced storage techniques are summarized.

Heffner, P.↗

Electrical Capacitance Volume Tomography with High-Contrast Dielectrics

The Electrical Capacitance Volume Tomography (ECVT) system has been designed to complement the tools created to sense the presence of water in nonconductive spacecraft materials, by helping to not only find the approximate location of moisture but also its quantity and depth. The ECVT system has been created for use with a new image reconstruction algorithm capable of imaging high-contrast dielectric distributions. Rather than relying solely on mutual capacitance readings as is done in traditional electrical capacitance tomography applications, this method reconstructs high-resolution images using only the self-capacitance measurements. The image reconstruction method assumes that the material under inspection consists of a binary dielectric distribution, with either a high relative dielectric value representing the water or a low dielectric value for the background material. By constraining the unknown dielectric material to one of two values, the inverse math problem that must be solved to generate the image is no longer ill-determined. The image resolution becomes limited only by the accuracy and resolution of the measurement circuitry. Images were reconstructed using this method with both synthetic and real data acquired using an aluminum structure inserted at different positions within the sensing region. The cuboid geometry of the system has two parallel planes of 16 conductors arranged in a 4 4 pattern. The electrode geometry consists of parallel planes of copper conductors, connected through custom-built switch electronics, to a commercially available capacitance to digital converter. The figure shows two 4 4 arrays of electrodes milled from square sections of copper-clad circuit-board material and mounted on two pieces of glass-filled plastic backing, which were cut to approximately square shapes, 10 cm on a side. Each electrode is placed on 2.0-cm centers. The parallel arrays were mounted with the electrode arrays approximately 3 cm apart. The open ends were surrounded by a metal guard to reduce the sensitivity of the electrodes to outside interference and to help maintain the spacing between the arrays. Other uses for this innovation potentially include quantifying the amount of commodity remaining in the fuel and oxidizer tanks while on-orbit without having to fire spacecraft engines. Another orbit application is moisture sensing in plant-growth experiments because microgravity causes moisture in soil to distribute itself in unusual ways. At the moment, the hardware and image reconstruction technique may only be of interest to people involved in nondestructive evaluation. The reconstructed image takes almost a full week to reproduce with existing computer power. However, because computer power and speeds follows Moore s Law, execution times are likely to become acceptable within the next five to eight years. The code was written in Mathematica for dedicated use with the ECVT system. In its present form, it is not suitable to be used directly as a consumer product. However, the code could be likely improved by rewriting it in a compiled language such as C or Fortran.

Nurge, Mark↗

The Integrated Reference Region Analysis for Parallel DFIGs’ Interfacing Inductors

Although the traditional design of doubly-fed induction generators (DFIGs)’ interfacing inductors consider the peak ripple of the grid-side converter (GSC)’s output current, it does not consider the inductors’ impact on DFIGs’ smallsignal stability. Located in series between the GSC and the stator, the inappropriate selection of the interfacing inductor can easily result to system instability. Therefore, this paper first proposes the integrated reference region analysis for small wind farm's interfacing inductors to improve the traditional design method. Firstly, a new detailed parallel DFIGs’ smallsignal model that considers output currents’ coupling is built in d-q coordinate system with state-space approach. The model focuses on representing the operating states of parallel DFIGs in wind farm. Secondly, the linearized state-space matrix of parallel DFIGs is decomposed into nominal-value matrix and location matrix. Considering the traditional design requirements, the integrated reference region for interfacing inductor is proposed through spectral radius and bialternate matrix sum (BMS). Furthermore, it can provide better guidance for parameter selecting and stabilization method researches. Finally, the simulation and experimental results show that the proposed integrated reference region for parallel DFIGs’ interfacing inductors is accurate and instructive.

47 OTHER INSTRUMENTATION↗

SiC-Based 5-kV Universal Modular Soft-Switching Solid-State Transformer (M-S4T) for Medium-Voltage DC Microgrids and Distribution Grids

Medium-voltage DC (MVDC) grids are attractive for electric aircraft and ship power systems, battery energy storage system (BESS), fast charging electric vehicle (EV), etc. Such EV or BESS applications need isolated bidirectional MVDC to LVDC or LVAC converters. However, the existing Si-based solutions cannot fulfill the requirements of a high-efficiency and robust converter for MVDC grids. This paper presents a 5 kV SiC-based universal modular solid-state transformer (SST). This universal current-source SST can interface either a LVAC or LVDC grid with a MVDC grid in single-stage power conversion, while the conventional dual active bridge (DAB) converter needs an additional inverter. The proposed SST module using 3.3 kV SiC MOSFETs and diodes is bidirectional and can serve as a building block in series or parallel for higher-voltage higher-power systems. The topology of each module is based on the soft-switching solid-state transformer (S4T) with reduced conduction loss, which features reduced EMI through controlled dv/dt, and high efficiency with full-range ZVS for main devices and ZCS for auxiliary devices. Operation principle of the modular S4T (M-S4T), capacitor voltage balancing control between the cascaded modules, design of components including a medium-voltage (MV) medium-frequency transformer (MFT) to realize a 50 kVA 5 kV DC to 600 V DC or 480 V AC M-S4T are presented. Importantly, the MV MFT prototype achieves very low leakage inductance (0.13%) and 15 kV insulation with coaxial cables and nanocrystalline cores. Here, the proposed universal modular SST is compared against the DAB solution and verified with DC-DC and DC-AC simulation and 4 kV experimental results. Significantly, the MV experimental results of a modular DC transformer with each module at MVDC are rarely covered in the literature and reported for the first time.

14 SOLAR ENERGY↗