At least 181 records · Page 10

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Health impact assessment of Roma housing policies in Central and Eastern Europe: A comparative analysis

Marginalised Roma communities in European countries live in substandard housing conditions the improvement of which has been one of the major issues of the Decade of Roma Inclusion, the ongoing intergovernmental European Roma programme. The paper presents EU-funded health impact assessments of national Roma housing policies and programmes in 3 Central and Eastern European countries in light of the evaluation of a completed local project in a fourth CEE country so as to compare predicted effects to observed ones. Housing was predicted to have beneficial health effects by improving indoor and outdoor conditions, access to services, and socioeconomic conditions. Negative impacts were predicted only in terms of maintenance expenses and housing tenure. However, observed impacts of the completed local project did not fully support predictions especially in terms of social networks, satisfaction with housing and neighbourhood, and inhabitant safety. In order to improve the predictive value of HIA, more evidence should be produced by the careful evaluation of locally implemented housing projects. In addition, current evidence is in favour of planning Roma housing projects at the local rather than at the national level in alignment with the principle of subsidiarity. - Highlights: Black-Right-Pointing-Pointer Predictive validity of HIA of national Roma housing policies - in light of current evidence - is low. Black-Right-Pointing-Pointer Implemented housing projects should be comprehensively evaluated to improve reliability of HIA. Black-Right-Pointing-Pointer Roma housing projects should be planned at the local rather than at the national level. Black-Right-Pointing-Pointer HIA should be used to plan Roma housing projects at the local level.

54 ENVIRONMENTAL SCIENCES↗

Quercetin as natural stabilizing agent for bio-polymer

The introduction of antioxidants in polymers is the main way to prevent or delay the degradation process. In particular natural antioxidants receive attention in the food industry also because of their presumed safety. In this work bio-polymers, i.e. a commercial starch-based polymer (Mater-Bi®) and a bio-polyester (PLA), and a bio-polyether (PEO) were additivated with quercetin, a natural flavonoid antioxidants, in order to formulate bio-based films for ecosustainable packaging and outdoor applications. The photo-oxidation behavior of unstabilized and quercetin stabilized films was analyzed and compared with the behavior of films additivated with a commercial synthetic light stabilizer. The quercetin is able to slow down the photo-degradation rate of all bio-polymeric films investigated in similar way to the synthetic stabilizer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes Habitat for Humanity The Woods

The Washington State University (WSU) Energy Program's Building America (BA) team conducted a case study of a high-performance affordable housing community: The Woods (Figure 1). This BA effort is part of a larger-scale study of 30 homes funded from 2013-2016 by Tacoma Public Utilities (TPU) and the Bonneville Power Administration. The Woods is a Habitat for Humanity (HFH) community of homes certified by ENERGY STAR Homes Northwest (ESHNW); the community is in the marine climate of Tacoma/Pierce County, Washington. This research report builds on an earlier preliminary draft 2014 BA report and includes significant billing analysis and cost-effectiveness research from a collaborative and ongoing DHP research effort for TPU and the Bonneville Power Administration. This final BA report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing. The research goal of the U.S. Department of Energy's BA research team Building America Partnership for Improved Residential Construction was to compare a ductless heat pump (DHP) hybrid system (DHP in common area/electric resistance [ER] in bedrooms) to an all-electric zonal ER system in high-performance single-family affordable housing. This effort included assessing the costs and benefits of a DHP/ER hybrid system located in the main living area to offset the primary heating demand of zonal ER heaters in the bedroom zones and comparing these findings to data from of new affordable single-family housing in Washington State. This report includes: (1) Measured indoor and outdoor temperatures and relative humidity (RH) in the homes. (2) Field testing results of heating, ventilating, and air-conditioning equipment; ventilation system airflows; building envelope tightness; lighting, appliance, and other input data required for preliminary Building Energy Optimization (BEopt) modeling; and ENERGY STAR field verification (3) BEopt modeling results compared to measured energy use. (4) A comparison of the space heat energy consumption of a DHP/ER hybrid heating system and a traditional zonal ER heating system installed in the same home. This comparison is made by implementing a series of weekly "flip-flop tests" (referred to here as "switchback" tests per TPU) to compare space heating, temperature, and RH in zonal ER heating mode with a DHP/ER mode as discussed in the Building America Test Plan (Lubliner 2010a). (5) Cost data from HFH and other sources related to building efficiency measures focusing on the DHP/ER hybrid heating system. (6) An evaluation of the thermal performance and cost benefit of DHP/ER hybrid heating systems in these high-performance homes employing life cycle cost analysis for energy code policy and monthly cash flow analysis of HFH homeowners. (7) Post-monitoring occupant survey results. The report also provides the following stakeholder findings and recommendations: (1) DHP single-head systems at The Woods are cost-effective to new homebuyers of these high-performance all-electric homes. (2) Stakeholder education is needed on design, inspection, and commissioning; documentation is needed for heat recovery ventilation (HRV) and from ENERGY STAR builders, verifiers, and inspectors to help ensure that the houses meet the goal of "build tight, ventilate right." (3) A code gap in inspection and enforcement was identified that should be addressed by: (3a) Improving the fire marshal's approach to sprinkler attic piping freeze protection; (3b) Improving the maintenance of ceiling insulation continuity; and (3c) Educating the local building inspector on attic insulation inspection concerns that allow for maximizing design improveme...

affordable housing↗

Reliability and Engineering of Thin-Film Photovoltaic Modules. Research forum proceedings

A Research Forum on Reliability and Engineering of Thin Film Photovoltaic Modules, under sponsorship of the Jet Propulsion Laboratory's Flat Plate Solar Array (FSA) Project and the U.S. Department of Energy, was held in Washington, D.C., on March 20, 1985. Reliability attribute investigations of amorphous silicon cells, submodules, and modules were the subjects addressed by most of the Forum presentations. Included among the reliability research investigations reported were: Arrhenius-modeled accelerated stress tests on a Si cells, electrochemical corrosion, light induced effects and their potential effects on stability and reliability measurement methods, laser scribing considerations, and determination of degradation rates and mechanisms from both laboratory and outdoor exposure tests.

Ross, R. G., Jr.↗

A new class of tandems: Optically coupled III-V/silicon module with outdoor efficiency exceeding 30%

The aim of this project was to introduce a new class of technology—that of high-efficiency silicon-based tandem photovoltaic (PV) modules—that, with follow-on development, has a clear path to reduced levelized cost of electricity (LCOE) for utility-scale power generation. In particular, the objective of the project was to demonstrate the first 30%-efficient III-V/silicon module in outdoor conditions using a tandem geometry in which the sub-cells are detached physically but coupled optically. In present PV power plants installed in the US, the module makes up only approximately one-third of the cost; area-dependent balance-of-systems (BOS) costs such as installation materials, labor, land, and site prep made up an additional third, and area-independent BOS costs round out the final third. With this pricing structure, (annually averaged) module efficiency is a clear market driver: increase the annual energy output per module and the effective costs translated into $/W of both the module and the area-dependent BOS—two-thirds of the total cost—decrease proportionately. However, the dominant PV technology—flat-plate silicon modules—is reaching its theoretical efficiency limit, and thus a tandem technology in which silicon is coupled with a wider-bandgap cell is a promising route to remain responsive to market forces. As it is not trivial to couple silicon with other cells in conventional two-terminal geometries due to, e.g., lattice mismatch, this project introduced a new, four-terminal configuration using a “PVMirror.” A PVMirror utilizes PV cells as a three-in-one technology—they act as a concentrating mirror, spectrum splitter, and high-efficiency light-to-electricity converter. Light is incident upon a full-aperture dichroic mirror that reflects visible light and transmits infrared light. The transmitted light is absorbed in silicon PV cells that are placed behind the dichroic mirror and that convert IR photons to electricity with high efficiency. The dichroic mirror and silicon PV cells are affixed to a curved glass trough that tracks the sun about a single, North-South axis such that the reflected VIS light is concentrated at a common line focus, at which is placed a second, wider-bandgap GaAs PV cell having high efficiency at shorter wavelengths. The innovation of PVMirrors lies in their design, which maximizes annual energy output and minimizes the constraints placed on the sub-cells. In particular, the cells are free of lattice- and current-matching restrictions, neither cell requires a transparent rear electrode, and either sub-cell can be placed at the focus depending on their relative costs. Furthermore, the greatest benefit of PVMirrors is that they make use of a portion of the diffuse light whereas concentrator tandems cannot. This results in a benefit in energy yield and extends PVMirrors’ competitive range. Over the course of this one-year project, a silicon PVMirror and GaAs receiver were fabricated, characterized, and placed outdoors on a sun tracker, where the efficiency of the tandem “module” was measured for three days. Notable results include the first demonstration of this flexible tandem configuration, a maximum tandem efficiency of 29.6% (just shy of the 30% overall project goal), successful conversion of diffuse light into electricity, a thorough loss analysis indicating a path to over 31% efficiency, and a roadmap to cost-competitive PVMirror tandems using a wide-bandgap polycrystalline PVMirror and a silicon receiver. Development of a >18%-efficient wide-bandgap polycrystalline cell—the key enabler of this envisioned tandem—should be a future research focus. This project has laid the groundwork for a PV technology that, with continued development, has the potential to reach LCOEs as low as $0.03/kWh according to our calculations. Such a system would provide the public with inexpensive, clean solar power.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulating Complex Window Systems using BSDF Data

Nowadays, virtual models are commonly used to evaluate the performance of conventional window systems. Complex fenestration systems can be difficult to simulate accurately not only because of their geometry but also because of their optical properties that scatter light in an unpredictable manner. Bi-directional Scattering Distribution Functions (BSDF) have recently been developed based on a mixture of measurements and modelling to characterize the optics of such systems. This paper describes the workflow needed to create then use these BSDF datasets in the Radiance lighting simulation software. Limited comparisons are made between visualizations produced using the standard ray-tracing method, the BSDF method, and that taken in a full-scale outdoor mockup.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cas9 deletion of lutein biosynthesis in the marine alga Picochlorum celeri reduces photosynthetic pigments while sustaining high biomass productivity

Domestication of algae for food and renewable biofuels remains limited by the low photosynthetic efficiencies of processes that have evolved to be competitive for optimal light capture, incentivizing the development of large antennas in light-limiting conditions, thus decreasing efficient light utilization in cultivated ponds or photobioreactors. Reducing the pigment content to improve biomass productivity has been a strategy discussed for several decades and the ability to reduce pigment significantly is now fully at hand thanks to the widespread use of genome editing tools. Picochlorum celeri is one of the fastest growing marine algae identified and holds particular promise for outdoor cultivation, especially in saline water and warm climates. We show that while chlorophyll b is essential to sustain high biomass productivities under dense cultivation, removing Picochlorum celeri’s main carotenoid, lutein, leads to a decreased total chlorophyll content, higher a/ b ratio, reduced functional LHCII cross section and higher maximum quantum efficiencies at lower light intensities, resulting in an incremental increase in biomass productivity and increased PAR-to-biomass conversion efficiency. These findings further strengthen the existing strategies to improve photosynthetic efficiency and biomass production in algae.

59 BASIC BIOLOGICAL SCIENCES↗

Strong-Bonding Hole-Transport Layers Reduce Ultraviolet Degradation of Perovskite Solar Cells

The light-emitting diodes (LEDs) used in indoor testing of perovskite solar cells do not expose them to the levels of ultraviolet (UV) radiation that they would receive in actual outdoor use. We report degradation mechanisms of p-i-n-structured perovskite solar cells under unfiltered sunlight and with LEDs. Weak chemical bonding between perovskites and polymer hole-transporting materials (HTMs) and transparent conducting oxides (TCOs) dominate the accelerated A-site cation migration, rather than direct degradation of HTMs. An aromatic phosphonic acid, [2-(9-ethyl-9H-carbazol-3-yl)ethyl]phosphonic acid (EtCz3EPA), enhanced bonding at the perovskite/HTM/TCO region with a phosphonic acid group bonded to TCOs and a nitrogen group interacting with lead in perovskites. A hybrid HTM of EtCz3EPA with strong hole-extraction polymers retained high efficiency and improved the UV stability of perovskite devices, and a champion perovskite minimodule-independently measured by the Perovskite PV Accelerator for Commercializing Technologies (PACT) center-retained operational efficiency of >16% after 29 weeks of outdoor testing.

14 SOLAR ENERGY↗

Shortwave Array Spectroradiometer–Hemispheric (SASHe) Instrument Handbook

The Shortwave Array Spectroradiometer–Hemispheric (SASHe) provides measurements of direct solar, hemispheric diffuse, and total hemispheric shortwave irradiance over a continuous spectral range from approximately 300 nm to 1700 nm at a rate of about 30 seconds. The SASHe design connects an optical collector located outdoors to a pair of spectrometers and data collections systems located indoors within a climate-controlled building via an umbilical cable of fiber optic and electrical cables. The light collector uses a small Spectralon button as a hemispheric diffuser with a shadowband to distinguish signal from diffuse sky and direct sun.

54 ENVIRONMENTAL SCIENCES↗

Shortwave Array Spectroradiometer–Zenith (SASZe) Instrument Handbook

The Shortwave Array Spectroradiometer – Zenith (SASZe) provides measurements of zenith spectral shortwave radiance at 1Hz over a continuous spectral range from approximately 300 nm to 1700 nm. The SASZe design connects an optical collector located outdoors to a pair of spectrometers and data collections system located indoors within a climate-controlled building via an umbilical cable of fiber optic and electrical cables. The light collector incorporates a collimator yielding a 1-degree Full Width at Half Maximum (FWHM) field of view. The data-acquisition electronics and spectrometers include an in-line fiber optic shutter and two Avantes fiber-coupled grating spectroradiometers within a temperature-controlled container. The Avantes Avaspec ULS 2048 charge-coupled device (CCD) spectrometer covers the wavelength range from about 300-1100 nm with a pixel spacing of less than 0.6 nm and a spectral resolution of about 2.4 nm FWHM. The Avantes Avaspec NIR256-1.7 spectrometer covers the wavelength range from about 950 nm to 1700 nm with a pixel spacing of less than 4 nm and a spectral resolution of about 6 nm FWHM.

54 ENVIRONMENTAL SCIENCES↗

Trait drift in microalgae and applications for strain improvement

Microalgae are increasingly used to generate a wide range of commercial products, and there is growing evidence that microalgae-based products can be produced sustainably. However, industrial production of microalgal biomass is not as developed as other biomanufacturing platform technologies. In addition, results of bench-scale research often fail to translate to large-scale or mass production systems. This disconnect may result from trait drift and evolution occurring, through time, in response to unique drivers in each environment, such as cultivation regimes, weather, and pests. Moreover, outdoor and indoor cultivation of microalgae has the potential to impose negative selection pressures, which makes the maintenance of desired traits a challenge. In this context, this review sheds the light on our current understanding of trait drift and evolution in microalgae. Here, we delineate the basics of phenotype plasticity and evolution, with a focus on how microalgae respond under various conditions. In addition, we review techniques that exploit phenotypic plasticity and evolution for strain improvement in view of industrial commercial applications, highlighting associated advantages and shortcomings. Finally, we suggest future research directions and recommendations to overcome unwanted trait drift and evolution in microalgae cultivation.

59 BASIC BIOLOGICAL SCIENCES↗

Challenges, Technological Pathways and Trade-Offs of Perovskite Solar Modules for Long-Term Operation

Perovskite solar modules (PSMs) have emerged as a promising photovoltaic technology due to their high efficiency, low fabrication cost and compatibility with lightweight and flexible applications. However, ensuring long-term reliable performance under real-world conditions remains a critical barrier to commercialization. PSMs degrade through mechanisms that differ substantially from those affecting established technologies such as silicon, particularly under environmental stressors like ultraviolet light, oxygen, temperature cycling and reverse bias. Here we provide an analysis of the degradation pathways specific to perovskite modules and discuss why standard accelerated tests often fail to predict outdoor performance. We conceptualize challenges across material, device and module levels and evaluate strategies to mitigate ion migration, interfacial breakdown and encapsulation failure. By highlighting the need for realistic testing protocols and durable materials, we propose a framework highlighting key challenges, technological pathways and the trade-offs required to extend perovskite module lifetimes towards long-term operation, aiming to guide the development of PSMs capable of a 30-year operational lifetime.

14 SOLAR ENERGY↗

Outdoor Testing of c-Si Photovoltaic Modules with Spectrally-Selective Mirrors for Operating Temperature Reduction

The efficiency of a c-Si cell drops with increasing cell temperature. A typical photovoltaic module with a c-Si cell will operate 20-30K above ambient temperature. Spectrally-selective photonic mirrors which reflect sub-bandgap light can reduce waste heat generated by parasitic absorption in the module and reduce module operating temperature. Here, a spectrally selective 4-layer and 12-layer mirror are designed and fabricated on module cover glass. When integrated into modules, these mirrors reduce the operating temperature of the module by 0.16K and 1.5K, respectively when compared to a module with bare outer glass.

14 SOLAR ENERGY↗

Non-fullerene acceptor organic photovoltaics with intrinsic operational lifetimes over 30 years

Abstract Organic photovoltaic cells (OPVs) have the potential of becoming a productive renewable energy technology if the requirements of low cost, high efficiency and prolonged lifetime are simultaneously fulfilled. So far, the remaining unfulfilled promise of this technology is its inadequate operational lifetime. Here, we demonstrate that the instability of NFA solar cells arises primarily from chemical changes at organic/inorganic interfaces bounding the bulk heterojunction active region. Encapsulated devices stabilized by additional protective buffer layers as well as the integration of a simple solution processed ultraviolet filtering layer, maintain 94% of their initial efficiency under simulated, 1 sun intensity, AM1.5 G irradiation for 1900 hours at 55 °C. Accelerated aging is also induced by exposure of light illumination intensities up to 27 suns, and operation temperatures as high as 65 °C. An extrapolated intrinsic lifetime of > 5.6 × 10 4 h is obtained, which is equivalent to 30 years outdoor exposure.

14 SOLAR ENERGY↗

A comparison of Nannochloropsis salina growth performance in two outdoor pond designs: conventional raceways versus the ARID pond with superior temperature management

The present study examines how climatic conditions and pond design affect the growth performance of microalgae. From January to April of 2011, outdoor batch cultures of Nannochloropsis salina were grown in three replicate 780 L conventional raceways, as well as in an experimental 7500 L ARID (Algae Raceway Integrated Design) pond. The ARID culture system utilizes a series of 8 to 20 cm deep basins and a 1.5 m deep canal to enhance light exposure and mitigate temperature variations and extremes. The ARID culture reached the stationary phase 27 days earlier than the conventional raceways, which can be attributed to its superior temperature management and shallower basins. On a night when the air temperature dropped to -9 °C, the water temperature was 18 °C higher in the ARID pond than in the conventional raceways. Lipid and fatty acid content ranged from 16 - 25 % and 5 - 15 %, respectively, as a percentage of AFDW. Palmitic, palmitoleic, and eicosapentaenoic acid comprised the majority of fatty acids. While the ARID culture system achieved nearly double the volumetric productivity relative to the conventional raceways (0.023 vs 0.013 g L-1day-1), areal biomass productivities were of similar magnitude in both pond systems (3.34 vs. 3.47 g m-2day-1), suggesting that the ARID pond design has to be further optimized, most likely by increasing the culture depth or operating at higher cell densities while maintaining adequate mixing.

Crowe, Braden J↗

Modeling microalgal growth in an airlift-driven raceway reactor

In previous proof-of-concept studies, feasibility of a new airlift-raceway configuration and its energetic advantage and improved CO2 utilization efficiency over the traditional raceways and photobioreactors have been documented. In the current study, a mathematical model for predicting biomass growth in the airlift-raceway reactor is presented, which includes supply and transfer of CO2 and the synergetic effects of light, CO2, nitrogen, and temperature. The model was calibrated and validated with data from prototype scale versions of the reactor on two test species: Nannochloropsis salina and Scenedesmus sp., cultivated under indoor and outdoor conditions. Predictions of biomass concentrations by the proposed model agreed well with the temporal trend of the experimental data, with r(2) ranging from 0.96 to 0.98, p<0.001. A sensitivity analysis of the 10 model parameters used in this study revealed that only three of them were significant, with sensitivity coefficients ranging from 0.08 to 0.13.

09 BIOMASS FUELS↗

Field test and simulation evaluation of variable refrigerant flow systems performance

Our study aims to compare the performance of a Variable Refrigerant Flow (VRF) system with a Roof Top Unit, (RTU) and a variable-air-volume (VAV) system through field tests and energy simulations. The field test was conducted in as similar conditions as possible between the two systems, such as the installation and operating environments of heating, the ventilation and air conditioning (HVAC) system, including internal heat gain and outdoor conditions, including buildings to compare the performance of the two systems accurately. A VRF system and RTU were installed at the test building located in Oak Ridge, Tennessee, in the USA. The same internal heat gain was generated at the same operating time of the two systems using lighting, electric heaters, and humidifiers inside the building. The HVAC system was alternately operated between cooling and heating operations to acquire energy performance data and to compare energy usage. Furthermore, an hourly building energy simulation model was developed with regard to the VRF system and RTU, and then the model was calibrated using actual measured data. Then, annual energy consumption of the two systems were compared and analyzed using the calibrated model. Moreover, additional analysis was conducted when the controlled discharge air temperature in the RTU was changed. The field test result showed that when energy consumptions of two systems were compared at the same outdoor conditions, using the weather-normalized model, the VRF system exhibited an energy reduction of approximately 17% during cooling operation and of approximately 74% during heating operations. A comparison on the annual energy consumption using simulations showed that the VRF system reduced energy consumption more than that of the RTU by 60%. Furthermore, when the discharge air temperature in the RTU was controlled according to the outdoor air temperature, energy consumption of the RTU was reduced by 6% in cooling operations and by 18% in heating operation. As a result, energy consumption of the VRF system was reduced by more than that of the RTU by 55% approximately.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗