Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical pumping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Influence of modulation frequency in rubidium cell frequency standards

The error signal which is used to control the frequency of the quartz crystal oscillator of a passive rubidium cell frequency standard is considered. The value of the slope of this signal, for an interrogation frequency close to the atomic transition frequency is calculated and measured for various phase (or frequency) modulation waveforms, and for several values of the modulation frequency. A theoretical analysis is made using a model which applies to a system in which the optical pumping rate, the relaxation rates and the RF field are homogeneous. Results are given for sine-wave phase modulation, square-wave frequency modulation and square-wave phase modulation. The influence of the modulation frequency on the slope of the error signal is specified. It is shown that the modulation frequency can be chosen as large as twice the non-saturated full-width at half-maximum without a drastic loss of the sensitivity to an offset of the interrogation frequency from center line, provided that the power saturation factor and the amplitude of modulation are properly adjusted.

Audoin, C.↗

The High Spectral Resolution Lidar

The High Spectral Resolution Lidar (HSRL) system was developed for the remote measurement of atmospheric optical properties. Measurements are obtained by the separation of the backscattered signal into aerosol and molecular channels using a high spectral resolution Fabry-Perot optical interferometer to separate the aerosol contributions to backscatter near the laser wavelength from the Doppler-shifted molecular component of the backscatter. The transmitter consists of an optically pumped pulsed dye laser of the oscillator-amplifier design which emits at 467.88 nm, with a bandwidth of less than 0.3 pm. The transmitter and receiver share a common Schmidt-Cassegrain telescope, although they do not share the same field stop, but rather two conjugate stops. The HSRL system uses a computer-controlled dual-channel photon-counting data acquisition system providing for stable measurements at very low power levels and an excellent dynamic range. The system has been used to obtain airborne measurements of height profiles of aerosol and molecular backscatter cross sections.

Eloranta, E. W.↗

Two-beam interferometer for optical constants measurements at near-millimeter wavelengths

A simple and versatile instrument for the measurement of optical constants in the near millimeter spectral region is described. Studies of quasi-optical components used in this instrument for effective beam transmission and control are reported. These studies include transmission characteristics of dielectric waveguides and performance of a variable coupler based on frustrated total internal reflection. Operation of this instrument as a two-beam interferometer for determining the index of refraction or as a device to measure transmission for determining the absorption coefficient are described. Values measured with this instrument at 245 GHz, using an optically pumped molecular laser as the source, are reported for several low-loss materials. Appropriate corrections and error estimates are discussed. The potential for improvement and increased accuracies are discussed.

Jones, C. R.↗

High-power radiating plasma

The physical principles underlying the use of radiating plasmas for the optical pumping of lasers are described. Particular consideration is given to the properties of radiating plasmas; radiation selectivity; the dynamics, equilibrium, and stability of radiating plasmas; the radiative Reynolds number; and experimental results on radiating discharges.

Rozanov, V. B.↗

A 150 Micron Heterodyne Spectrometer for Airborne Astronomy

The advantages of heterodyne detection for high resolution spectroscopy were long known to radio astronomers. Heterodyne spectroscopy was productive at submillimeter wavelengths, but its extension to shorter submillimeter and far-infrared (FIR) wavelengths was hampered by inadequate mixers and local oscillators. A significant advance in FIR receiver technology was demonstrated using an optically-pumped FIR laser and a Schottky-diode mixer. Any similar spectrometer intended for airborne observations at shorter wavelengths must be compatible with the more restrictive aircraft environment. The effectiveness of the design of a FIR heterodyne spectrometer was verified in ground-based observations with a prototype version. The airborne successor is even more compact, and has a much broader spectral coverage. Flight tests are scheduled for the new instrument.

Betz, A.↗

Photo Hall-effect characterization of closely compensated Ge:Be

The temperature dependence of the free-carrier concentration in germanium doped with the double acceptor Be has been investigated using the photo Hall-effect technique and found to be strongly temperature dependent when the residual shallow impurities are closely compensated. Close compensation of shallow levels was achieved by controlling the concentration of a beryllium-hydrogen acceptor complex A(Be,H) which is present in crystals grown under a H2 atmosphere. This complex can be removed with high-temperature annealing. An increase of up to two orders of magnitude in free-carrier lifetime as a function of temperature is found to occur between 5 and 11 K in closely compensated material due to the population inversion of ionized centers created by optical pumping.

Germer, T. A.↗

The JPL trapped mercury ion frequency standard

In order to provide frequency standards for the Deep Space Network (DSN) which are more stable than present-day hydrogen masers, a research task was established under the Advanced Systems Program of the TDA to develop a Hg-199(+) trapped ion frequency standard. The first closed-loop operation of this kind is described. Mercury-199 ions are confined in an RF trap and are state-selected through the use of optical pumping with 194 nm UV light from a Hg-202 discharge lamp. Absorption of microwave radiation at the hyperfine frequency (40.5 GHz) is signaled by atomic fluorescence of the UV light. The frequency of a 40.5 GHz oscillator is locked to a 1.6 Hz wide atomic absorption line of the trapped ions. The measured Allan variance of this locked oscillator is currently gamma sub y (pi) = 4.4 x 10 to the minus 12th/square root of pi for 20 is less than pi is less than 320 seconds, which is better stability than the best commercial cesium standards by almost a factor of 2. This initial result was achieved without magnetic shielding and without regulation of ion number.

Prestage, J. D.↗

Transfer and redistribution of polarized light in resonance lines. I - Quantum formulation with collisions

Equations are derived quantum mechanically for the radiative transfer of polarized light and statistical equilibrium governing the formation of resonance lines in nonhydrogenic species. Redistribution due to collisions is specifically included, but magnetic fields are neglected. The formulation accounts for excited level interference and optical pumping and is applicable to solar resonance lines such as Ca II H and K and Mg II h and k.

Streater, A.↗

Velocities and rotational excitation of interstellar H2 toward Pi Scorpii

A spectrum of Pi Sco showing numerous atomic lines and 70 absorption features from the Lyman and Werner transitions of interstellar H2 in rotational level J from zero to five is presented. Their shapes of the composite column density profiles are very nearly Gaussian with a one-dimensional rms velocity dispersion of 3 km/s. The behavior of shifts in the inferred N(H2) as a function of velocity are consistent with the overall profiles being composed of nearly symmetrical, tightly paced assemblies of about seven unresolved components. The relative overall column densities in the higher J levels of H2 are consistent with a model where these states are populated by optical pumping through the Lyman and Werner transitions, powered by UV radiation from nearby stars. The slight narrowing of the high-J profiles may be due to small clumps of H2 at radial velocities some 5-8 km/s from the core of the profile are exposed to a pumping flux about 10 times lower than that for the material near the profile's center.

Jenkins, Edward B.↗

Gaseous optical contamination of the spacecraft environment: A review

Interactions between the ambient atmosphere and orbiting spacecraft, sounding rockets, and suborbital vehicles, and with their effluents, give rise to optical (extreme UV to LWIR) foreground radiation which constitutes noise that raises the detection threshold for terrestrial and celestial radiations, as well as military targets. Researchers review the current information on the on-orbit optical contamination. Its source species are created in interaction processes that can be grouped into three categories: (1) Reactions in the gas phase between the ambient atmosphere and desorbates and exhaust; (2) Reactions catalyzed by exposed ram surfaces, which occur spontaneously even in the absence of active material releases from the vehicles; and (3) Erosive excitative reactions with exposed bulk (organic) materials, which have recently been identified in the laboratory though not as yet observed on spacecraft. Researchers also assess the effect of optical pumping by earthshine and sunlight of both reaction products and effluents.

Tran, N. H.↗

The Berkeley tunable far infrared laser spectrometers

A detailed description is presented for a tunable far infrared laser spectrometer based on frequency mixing of an optically pumped molecular gas laser with tunable microwave radiation in a Schottky point contact diode. The system has been operated on over 30 laser lines in the range 10-100/cm and exhibits a maximum absorption sensitivity near one part in a million. Each laser line can be tuned by + or - 110 GHz with first-order sidebands.

Blake, G. A.↗

An experimental apparatus for measuring surface resistance in the submillimeter-wavelength region

A method for measuring the surface electrical resistance of small metallic samples at submillimeter wavelengths is presented which employs a qausi-optical hemispherical resonator fed by an optically pumped far-infrared laser. The small beam size at the sample, which serves as a plane mirror, allows measurements on samples with widths as small as 5 mm. The quality factor is high, and surface resistance losses are readily measurable.

Cook, Jerry D.↗

Far infrared laser frequencies of CH3OD and N2H4

The frequencies of 26 laser lines with wavelengths between 57 and 534 microns are measured in the optically pumped laser gases CH3OD and N2H4. A pair of 12CO2 lasers are employed as a frequency standard for the heterodyne frequency measurements. As the measurements are oriented toward spectroscopic applications of FIR lasers where dense, broad, frequency coverage is essential, every strong pump absorption of the two molecules for new lines that might be made to lase by varying the laser gas pressure and the tuning of the pump laser are investigated.

Radford, H. E.↗

Electron-Tunneling Magnetometer

Electron-tunneling magnetometer is conceptual solid-state device operating at room temperature, yet offers sensitivity comparable to state-of-art magnetometers such as flux gates, search coils, and optically pumped magnetometers, with greatly reduced volume, power consumption, electronics requirements, and manufacturing cost. Micromachined from silicon wafer, and uses tunneling displacement transducer to detect magnetic forces on cantilever-supported current loop.

Kaiser, William J.↗

The 1.083 micron tunable CW semiconductor laser

A tunable CW laser is desired to produce light equivalent to the helium spectral line at 1.08 microns. This laser will serve as an optical pumping source for He-3 and He-4 atoms used in space magnetometers. This light source can be fabricated either as a semiconductor laser diode or a pumped solid state laser. Continuous output power of greater than 10 mW is desired. Semiconductor lasers can be thermally tuned, but must be capable of locking onto the helium resonance lines. Solid state lasers must have efficient pumping sources suitable for space configuration. Additional requirements are as follows: space magnetometer applications will include low mass (less than 0.5 kg), low power consumption (less than 0.75 W), and high stability/reliability for long missions (5-10 years).

Wang, C. S.↗

A comparison of Doppler lidar wind sensors for Earth-orbit global measurement applications

Now, there are four Doppler lidar configurations which are being promoted for the measurement of tropospheric winds: (1) the coherent CO2 Lidar, operating in the 9 micrometer region using a pulsed, atmospheric pressure CO2 gas discharge laser transmitter, and heterodyne detection; (2) the coherent Neodymium doped YAG or Glass Lidar, operating at 1.06 micrometers, using flashlamp or diode laser optical pumping of the solid state laser medium, and heterodyne detection; (3) the Neodymium doped YAG/Glass Lidar, operating at the doubled frequency (at 530 nm wavelength), again using flashlamp or diode laser pumping of the laser transmitter, and using a high resolution tandem Fabry-Perot filter and direct detection; and (4) the Raman shifted Xenon Chloride Lidar, operating at 350 nm wavelength, using a pulsed, atmospheric pressure XeCl gas discharge laser transmitter at 308 nm, Raman shifted in a high pressure hydrogen cell to 350 nm in order to avoid strong stratospheric ozone absorption, also using a high resolution tandem Fabry-Perot filter and direct detection. Comparisons of these four systems can include many factors and tradeoffs. The major portion of this comparison is devoted to efficiency. Efficiency comparisons are made by estimating the number of transmitted photons required for a single pulse wind velocity estimate of + or - 1 m/s accuracy in the middle troposphere, from an altitude of 800 km, which is assured to be reasonable for a polar orbiting platform.

Menzies, Robert T.↗

A laser-cooled cesium fountain frequency standard and a measurement of the frequency shift due to ultra-cold collisions

A frequency standard based on an atomic fountain of cesium atoms may have an accuracy of 10(exp -16) due to longer interaction times and smaller anticipated systematic errors. All of the known systematic effects that now limit the accuracy of the Cs frequency standard increase either linearly or as some higher power of the atom's velocity. The one systematic frequency shift which is dramatically different is the frequency shift due to the collisions between the laser cooled atoms. At a temperature of a few micro-K, the de Broglie wavelength (lambda(sub deB) = h/p, where h is Planck's constant and p is the momentum of the atom) is much larger than the scale of the interatomic potential. Under these conditions the collision cross sections can be as large as (lambda(sub deB)(sup 2))/Pi and the frequency shift due to these collisions was recently calculated. In our Cs atomic fountain, we laser cooled and trapped 10(exp 10) Cs atoms in 0.4 s. By shifting the frequencies of the laser beams, the atoms were launched upwards at 2.5 m/s and a fraction of the atoms were optically pumped into the F=3 ground state. The unwanted atoms in the F=4 ground state were removed from the fountain with radiation pressure from a laser beam tuned to excite only those atoms. The Cs atoms in the F=3 state traveled ballistically upwards, were excited by the microwave cavity, and then returned back through the same cavity in the atomic fountain configuration. By varying the cold atom density, a density dependent shift of -12.9 +/- 0.7 mHz or -1.4 x 10-12 for an average fountain density of (2.7 +/- 1.5) 10(exp 9) atoms/cm(sup 3) was measured.

Gibble, Kurt↗