Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Prototype design and experimental tests of a zoom mirror system for the APS upgrade

Mirror-based zoom optics systems can offer variable focal spot sizes over a wide range, which is essential for coherent nanoprobe beamlines, such as the proposed Atomic beamline in the Advanced Photon Source (APS) upgrade project. The success of the zoom mirror system in the nano-focusing regime requires the development of high-precision deformable mirrors, in-situ surface profilers and wavefront sensors, and advanced feedback control system. A prototype 1-D zoom mirror system consists of two vertical focusing mirrors was designed, assembled, and tested at the APS 1-BM beamline. The system consists of a bender-based mirror with a capacitive-sensorarray-based real-time mirror profiler, a bimorph adaptive mirror, and a grating interferometer for the wavefront monitoring. In this work, we present the design and test results of the prototype system demonstrating its zoom focusing capability.

adaptive optics↗

Undulator radiation of single electrons: coherence length and quantum-optical properties

The aims of the CLARA experiment at the Fermilab Integrable Optics Test Accelerator (IOTA) were to directly measure the coherence length of undulator radiation emitted by a single electron and to test whether the radiation is in a pure classical Glauber coherent state or in a quantum mixture of coherent and Fock states. We used a Mach-Zehnder interferometer (MZI) to study visible radiation generated by 150-MeV electrons circulating in the ring. The relative delay between the two arms of the MZI was adjusted by varying the length of one of them with a resolution of 10 nm. The intensity of the circulating beam spanned several orders of magnitude, down to single electrons. A pair of single-photon avalanche diodes (SPADs) was placed at the output of the MZI arms to detect photocounts with high efficiency and timing resolution. We describe the observed interference patterns and photocount rates as a function of interferometer delay and discuss their implications.

43 PARTICLE ACCELERATORS↗

Undulator Radiation of Single Electrons: Coherence Length and Quantum-Optical Properties

The aims of the CLARA experiment at the Fermilab Integrable Optics Test Accelerator (IOTA) were to directly measure the coherence length of undulator radiation emitted by a single electron and to test whether the radiation is in a pure classical Glauber coherent state or in a quantum mixture of coherent and Fock states. We used a Mach-Zehnder interferometer (MZI) to study visible radiation generated by 150-MeV electrons circulating in the ring. The relative delay between the two arms of the MZI was adjusted by varying the length of one of them with a resolution of 10 nm. The intensity of the circulating beam spanned several orders of magnitude, down to single electrons. A pair of single-photon avalanche diodes (SPADs) was placed at the output of the MZI arms to detect photocounts with high efficiency and timing resolution. We describe the observed interference patterns and photocount rates as a function of interferometer delay and discuss their implications.

43 PARTICLE ACCELERATORS↗

Field-gradient measurement using a Stern-Gerlach atomic interferometer with butterfly geometry

Atomic interferometers have been studied as a promising device for precise sensing of external fields. Among various configurations, a particular configuration with a butterfly-shaped geometry has been designed to sensitively probe field gradients. Here, we introduce a Stern-Gerlach (SG) butterfly interferometer by incorporating magnetic field in the conventional butterfly-shaped configuration. Atomic trajectories of the interferometer can be flexibly adjusted by controlling magnetic fields to increase the sensitivity of the interferometer, while the conventional butterfly interferometer using Raman transitions can be understood as a special case. We also show that the SG interferometer can keep high contrast against a misalignment in position and momentum caused by the field gradient.

74 ATOMIC AND MOLECULAR PHYSICS↗

Push—pull microring-assisted space-and-wavelength selective switch

We introduce a novel design of a space-and-wavelength selective switch based on microring-assisted Mach–Zehnder interferometers. Multiple pairs of overcoupled microring resonators are incorporated as efficient and narrowband phase shifters and are driven in push–pull scheme. We design and demonstrate a 2 × <#comment/> 2 × <#comment/> 2 λ <#comment/> elementary switch block with full spatial and spectral switching capabilities. The switching device’s cross talk suppression and extinction ratio both exceed 21 dB. We measure over 75 GHz optical bandwidth per channel and less than 1.5 dB power penalty at 10 − <#comment/> 9 BER when two 32 Gbps on–off keying signals are loaded simultaneously. This new class of switching elements can further enable compact and high-performance space-and-wavelength selective switch fabrics without the need for wavelength (de)multiplexers or parallel switching planes.

Huang, Yishen (ORCID:0000000278710462)↗

Interferometric measurements of refractive index and dispersion at high pressure

Abstract We describe a high precision interferometer system to measure the pressure dependence of the refractive index and its dispersion in the diamond anvil cell (DAC). The reflective Fabry–Perot fringe patterns created by both a white light and a monochromatic beam are recorded to determine both the sample thickness and its index at the laser wavelength and to characterize the dispersion in the visible range. Advances in sample preparation, optical setup, and data analysis enable us to achieve $$10^{-4}$$ 10 - 4 random uncertainty, demonstrated with an air sample, a factor of five improvement over the best previous DAC measurement. New data on $${\text{H}}_{2}\text{O}$$ H 2 O liquid water and ice VI up to 2.21 GPa at room temperature illustrate how higher precision measurements of the index and its optical dispersion open up new opportunities to reveal subtle changes in the electronic structure of water at high pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plateau de Bure High-z Blue Sequence Survey 2 (PHIBSS2): Search for Secondary Sources, CO Luminosity Functions in the Field, and the Evolution of Molecular Gas Density through Cosmic Time

We report on the results of a search for serendipitous sources in CO emission in 110 cubes targeting CO(2 − 1), CO(3 − 2), and CO(6 − 5) at z ∼ 1–2 from the second Plateau de Bure High-z Blue Sequence Survey (PHIBSS2). The PHIBSS2 observations were part of a 4 yr legacy program at the IRAM Plateau de Bure Interferometer aimed at studying early galaxy evolution from the perspective of molecular gas reservoirs. We present a catalog of 67 candidate secondary sources from this search, with 45 of the 110 data cubes showing sources in addition to the primary target that appear to be field detections, unrelated to the central sources. This catalog includes redshifts, line widths, and fluxes, as well as an estimation of their reliability based on their false-positive probability. We perform a search in the 3D Hubble Space Telescope/CANDELS catalogs for the secondary CO detections and tentatively find that ∼64% of these have optical counterparts, which we use to constrain their redshifts. Finally, we use our catalog of candidate CO detections to derive the CO(2 − 1), CO(3 − 2), CO(4 − 3), CO(5 − 4), and CO(6 − 5) luminosity functions over a range of redshifts, as well as the molecular gas mass density evolution. Despite the different methodology, these results are in very good agreement with previous observational constraints derived from blind searches in deep fields. They provide an example of the type of “deep-field” science that can be carried out with targeted observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhancing strontium clock atom interferometry using quantum optimal control

Strontium clock atom interferometry is a promising new technology, with multiple experiments under development around the world to explore its potential for dark matter and gravitational wave detection. In these detectors, large momentum transfer using sequences of many laser pulses is necessary, and thus high-fidelity pulses are important since small errors become magnified. Quantum optimal control (QOC) is a framework for developing control pulse waveforms that achieve high fidelity and are robust against experimental imperfections. Resonant single-photon transitions using the narrow clock transition of strontium involve significantly different quantum dynamics than more established atom interferometry methods based on far-detuned two-photon Raman or Bragg transitions, which leads to new opportunities and challenges when applying QOC. Here, we study in simulation QOC pulses for strontium clock interferometry and demonstrate their advantage over basic square pulses (primitive pulses) and composite pulses in terms of robustness against multiple noise channels. In conclusion, this could improve the scale of large momentum transfer in Sr clock interferometers, paving the way to achieving these scientific goals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cumulative fidelity of large-momentum-transfer clock atom interferometers in the presence of laser noise

Clock atom interferometry is an emerging technique in precision measurements that is particularly well suited for sensitivity enhancement through large momentum transfer (LMT). While current systems have demonstrated momentum separations of several hundreds of photon momenta, next-generation quantum sensors are targeting an LMT enhancement factor beyond 10 4 . However, the viability of LMT clock interferometers has recently come into question due to the potential impact of laser frequency noise. Here, in this work, we resolve this concern by analyzing the cumulative fidelity of sequential state inversions in an LMT atom interferometer. We show that the population error from 𝑛 pulses applied from alternating directions scales linearly with 𝑛. This is a significant advantage over the 𝑛 2 scaling that occurs when probing a two-level system 𝑛 times from the same direction. We further show that contributions to the interferometer signal from parasitic paths generated by imperfect pulses are negligible, for any loss mechanism. These results establish that laser frequency noise is not a practical limitation for the development of high-fidelity LMT clock atom interferometers.

Mach-Zehnder atom interferometry↗

Raytracing the long trace profiler

The optical design of the Long Trace Profiler optical system is explored with a commercial raytrace program, Zemax OpticStudio™ (ZOS)1, with the intent of finding and correcting sources of systematic error. ZOS provides both geometric raytracing tools and physical optics Gaussian beam propagation and diffraction image calculation tools, and two design modes, sequential component (SC) and non-sequential component (NSC) that are optimized for different aspects of the design process. The original LTP-II system employs a singlet lens with a 1250 mm focal length. It is optimized to provide minimum distortion over a surface slope angle range of ±5 mrad. Using the ZOS tools, we are able to simulate ghost rays that produce distortion in the beam spot image and can minimize the distortion by deliberate misalignment of the beamsplitter (BS) components. Unfortunately, the reference beam is compromised because of the component tilts. The most recent LTP500 system design simplifies the optical system and makes the reference beam usable again, even with misalignment of the polarizing beamsplitter (PBS). Two lenses are designed for the LTP500 - a cemented doublet that has been fabricated, and a singlet with one aspheric surface. Both have focal distances of 500 mm with an expanded angular measurement range of ±10 mrad. The aspheric singlet provides superior performance. ZOS allows the import of wavefront measurement data produced by commercial interferometer software. We apply the wavefront error measurement from the cemented doublet to the model to show that the 19nm RMS wavefront error needs to be improved by at least a factor of ten in order to reduce the systematic error to a level that will allow the LTP to approach its design limit of a few tens of nanoradians.

Takacs, Peter Z.↗

Origins and consequences of asymmetric nano-FTIR interferograms

Infrared scattering-type near-field optical microscopy, IR s-SNOM, and its broadband variant, nano-FTIR, are pioneering, flagship techniques for their ability to provide molecular identification and material optical property information at a spatial resolution well below the far-field diffraction limit, typically less than 25 nm. While s-SNOM and nano-FTIR instrumentation and data analysis have been discussed previously, there is a lack of information regarding experimental parameters for the practitioner, especially in the context of previously developed frameworks. Like conventional FTIR spectroscopy, the critical component of a nano-FTIR instrument is an interferometer. However, unlike FTIR spectroscopy, the resulting interference patterns or interferograms are typically asymmetric. Here, we unambiguously describe the origins of asymmetric interferograms recorded with nano-FTIR instruments, give a detailed analysis of potential artifacts, and recommend optimal instrument settings as well as data analysis parameters.

47 OTHER INSTRUMENTATION↗

Quantum Interferometric Pathway Selectivity in Difference-Frequency-Generation Spectroscopy

Even-order spectroscopies such as sum-frequency generation (SFG) and difference-frequency generation (DFG) can serve as direct probes of molecular chirality. Such signals are usually given by the sum of several interaction pathways that carry different information about matter. Here we focus on DFG, involving impulsive optical–optical–IR interactions, where the last IR pulse probes vibrational transitions in the ground or excited electronic state manifolds, depending on the interaction pathway. Spectroscopy with classical light can use phase matching to select the two pathways. In this theoretical study, we propose a novel quantum interferometric protocol that uses entangled photons to isolate individual pathways. Importantly, this additional selectivity originates from engineering the state of light using a Zou–Wang–Mandel interferometer combined with coincidence detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Theoretical and experimental analysis of the modulated phase grating X-ray interferometer

X-ray grating interferometry allows for the simultaneous acquisition of attenuation, differential-phase contrast, and dark-field images, resulting from X-ray attenuation, refraction, and small-angle scattering, respectively. The modulated phase grating (MPG) interferometer is a recently developed grating interferometry system capable of generating a directly resolvable interference pattern using a relatively large period grating envelope function that is sampled at a pitch that is small enough that X-ray spatial coherence can be achieved by using a microfocus X-ray source or G0 grating. We present the theory of the MPG interferometry system for a 2-dimensional staggered grating, derived using Fourier optics, and we compare the theoretical predictions with experiments we have performed with a microfocus X-ray system at Pennington Biomedical Research Center, LSU. The theoretical and experimental fringe visibility is evaluated as a function of grating-to-detector distance. Additionally, quantitative experiments are performed with porous carbon and alumina compounds, and the mean normalized dark-field signal is compared with independent porosimetry measurements. Qualitative analysis of attenuation and dark-field images of a dried anchovy are shown.

47 OTHER INSTRUMENTATION↗

Topological magneto-optical Kerr effect without spin-orbit coupling in spin-compensated antiferromagnet

The magneto-optical Kerr effect (MOKE), the differential reflection of oppositely circularly polarized light, has traditionally been associated with relativistic spin-orbit coupling (SOC), which links a particle’s spin with its orbital motion. In ferromagnets, large MOKE signals arise from the combination of magnetization and SOC, while in certain coplanar antiferromagnets, SOC-induced Berry curvature enables MOKE despite zero net magnetization. Theoretically, large MOKE can also arise in a broader class of magnetic materials with compensated spins, without relying on SOC - for example, in systems exhibiting real-space scalar spin chirality. The experimental verification has remained elusive. Here, we demonstrate such a SOC- and magnetization-free MOKE in the noncoplanar antiferromagnet Co 1/3 TaS 2 . Using a Sagnac interferometer microscope, we image domains of scalar spin chirality and their reversal. Our findings establish experimentally a new mechanism for generating large MOKE signals and position chiral spin textures in compensated magnets as a compelling platform for ultrafast, stray-field-immune opto-spintronic applications.

Magnetic properties and materials↗

Exploring Interferometry Diagnostics for Optical Stochastic Cooling at FAST/IOTA

Optical Stochastic Cooling (OSC) is an advanced beam-cooling technique that will precede the traditional stochastic cooling. This method leverages optical radiation and high-precision feedback to cool the particles more efficiently than traditional stochastic methods by more than three orders of magnitude. As such, it is an enabler for the development of next generation discovery science machines at the frontiers of energy and intensity. This paper focuses on the development of the second phase of OSC and improving extreme beam cooling technique in accelerators. Along with the assembly and use of an interferometer to provide diagnostics and optimization to OSC systems. The interferometer can allow for the observation and analysis of fringe patterns from a recreated simpler version in the laser room. By leveraging interferometric techniques, OSC can achieve higher efficiency, verification, stability and performance.

Teriba, Folashade↗

Arbitrary Achromatic Polarization Control with Reconfigurable Metasurface Systems

Abstract Dynamic control over the polarization state of light is foundational for many scientific and technological applications, yet it remains a challenge to dynamically tailor responses with arbitrary polarization bases over a broad bandwidth. Broadband metasurface systems that utilize microscale displacements between two metasurfaces to enable reconfigurable polarization responses within a predefined polarization basis are reported. The metasurface pairs form an interferometer, and the lateral displacements produce detour phase shifts within the interferometer beam paths that mediate polarization state tuning. It is shown how the metasurface systems can be designed using freeform topology optimization to enable tailorable elliptical birefringence responses over a large bandwidth and how cascaded metasurface systems can enable the mapping of input and output polarization states between any two points on the Poincare sphere. It is anticipated that these concepts will have utility in imaging, display, communications, and metrology applications in classical and quantum optical domains.

Wang, Evan W.↗

EXPLORING INTERFEROMETRY DIAGNOSTICS FOR OPTICAL STOCHASTIC COOLING AT FAST/IOTA

Optical Stochastic Cooling (OSC) is an advanced beam-cooling technique that will advance the traditional stochastic cooling. This method leverages optical radiation and high-precision feedback to cool the particles more efficiently than traditional stochastic methods by more than three orders of magnitude. As such, it is an enabler for the development of next generation discovery science machines at the frontiers of energy and intensity. This paper focuses on the development of the second phase of OSC and improving extreme beam cooling techniques in accelerators. The goal was to build and characterize a Mach-Zehnder Interferometer (MZI) in the FAST laser lab using known glass plates thickness which will allow future measurements of unknown phase change due to nonlinear amplification processes.

Teriba, Folashade↗