Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Using real-time nuclear activation detectors for measuring neutron yields from D(D, T)n reactions on the national ignition facility (NIF)

The National Ignition Facility (NIF) has 48 Real-Time Nuclear Activation Detectors distributed around the target chamber capable of measuring deuterium-triton reaction neutron yields with high precision. Here, in this work, we extend this functionality to deuterium–deuterium (DD) reaction neutrons using a nuclear reaction that occurs in the detector’s scintillator material. The corresponding decay of the activated material has a very short half-life of 5 s, which necessitates rapid data collection immediately following an experiment. In this regime, dead time can be very high (>50%) adding significant uncertainty to the measurement. To combat this, we have developed a dead time model that can self-consistently describe the measured data. Initial results show reasonable agreement (within 20%) with DD neutron yields from neutron time-of-flight spectrometers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of proton and neutron activation of metal samples in low Earth orbit

Progress in the following activities has been made: the analysis of the gamma ray spectra taken from samples flown in Spacelab 2; the search for and review of neutron and proton activation cross sections needed to analyze the results of the Long Duration Exposure Facility (LDEF) activation measurements; the consideration given to data analysis of the LDEF and Spacelab 2 samples; the plan to measure relevant cross sections with nuclear accelerator measurements; and the preparation of an extended gamma ray calibration sources continues through planning and direct measurement of gamma ray efficiency for a Ge(Li) as a function of position along the surface of the detector housing.

Laird, C. E.↗

How can a diverse set of integral and semi-integral measurements inform identification of discrepant nuclear data? [Slides]

Importance of nuclear data to bias changed significantly when including diverse measurement sets. LLNL pulsed sphere measurements provided information for 9 Be nuclear data above 2 MeV and subcritical benchmarks provided information for 240 Pu nuclear data between 100 keV and 10 MeV. Pulsed sphere leakage spectra and neutron noise observables are differently sensitive to nuclear data compared to critical benchmarks. Leakage spectra are sensitive to nuclear data above 5 MeV. Count rate and Feynman Y are more sensitive to nuclear data. A change in bias can help evaluators identify discrepant nuclear data. In the future, EUCLID plans to perform RAFIEKI analysis with additional benchmark and measurement sets.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

How can a diverse set of integral and semi-integral measurements inform identification of discrepant nuclear data?

Nuclear data are used for a variety of applications, including criticality safety, reactor performance, and material safeguards. Despite the breadth of use-cases, the effective neutron multiplication factor, keff, of ICSBEP critical assemblies are primarily used for nuclear data validation; these are sensitive to specific energy regions and nuclides and are unable to uniquely constrain nuclear data. As a consequence, general-purpose nuclear data libraries, such as ENDF/B-VIII.0, may have deficiencies that, while not apparent in criticality applications, negatively impact other applications, such as non-destructive analysis of special nuclear material and neutron diagnosed subcritical experiments. Recent work by the Experiments Underpinned by Computational Learning for Improvements in Nuclear Data (EUCLID) project developed a machine learning tool, RAFIEKI, which uses random forests and the SHAP metric to determine which nuclear data contribute most to predicted bias between measured and simulated responses (e.g. keff). This paper contrasts RAFIEKI analysis applied to keff only against RAFIEKI analysis with keff paired with either LLNL pulsed sphere measurements or subcritical benchmarks. Two examples show that a) including pulsed sphere measurements substantially increases 9Be nuclear data importance to bias between 2 and 15 MeV, and b) including subcritical benchmarks has the potential for disentangling compensating errors between 240Pu (n,el) and (n,il) cross-sections between 0.1 and 10 MeV. These results show that RAFIEKI analysis applied to response sets that include, but go beyond, keff can aid nuclear data evaluators in identifying issues in nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PHENIX Probing QCD Matter Through Heavy Flavor and Quarkonium at RHIC

Recent results from the PHENIX experiment on heavy flavors and quarkonia production in p + Al, p + Au, d + Au, and Au + Au collision systems at psNN = 200 GeV are summarized. The results are carried out by the measurements of the nuclear modification factors and elliptic flow. The nuclear modification factors measurements give insight into the energy loss of heavy quarks in the quark-gluon plasma medium along their path lengths. The elliptic flow measurements are a good tool to investigate the coupling of heavy quarks with the medium. The measurements are presented as a function of centrality, rapidity, and transverse momentum. The interpretations of the results in light of our current theoretical models, and comparison to LHCb and ALICE measurements are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Qualification and Re-Qualification of NDA Instruments

Non-Destructive Assay (NDA) instruments are a large component of nuclear material (NM) measurement at LANL. Nuclear Material Control and Accountability Group (SAFE-NMCA) personnel in the Safeguards Division are responsible for oversight of the instruments used for material accountability measurements. It is the responsibility of SAFE-NMCA to ensure that all instruments are operating as expected and can produce quality measurements to provide assurance that requirements of the DOE approved NMCA Plan are being met.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conversion kinetics during melting of simulated nuclear waste glass feeds measured by dissolution of silica

In this work, we experimentally investigated the batch-to-glass conversion kinetics of two low-activity and two high-level nuclear waste melter feeds that represent widely different behavior during melting; tests comprised thermogravimetric analysis, the feed expansion test, evolved gas analysis, and x-ray diffraction. Our study indicates that the conversion processes, which include gas-evolving reactions, dissolution of crystalline phases, and primary foam expansion and collapse, are interconnected and influenced by the feed’s thermal history. The fraction of dissolved silica was adopted as a measure of the extent of conversion inside the cold cap—the floating layer of feed material on the top surface of the melt in an electric melter. The interface between the cold cap and the free-flowing melt below was associated with a constant fraction of dissolved silica. The estimated viscosity of glass-forming melt at this interface lies within a narrow range for the feeds studied.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nuclear diagnostics for Inertial Confinement Fusion (ICF) plasmas

The field of nuclear diagnostics for Inertial Confinement Fusion (ICF) is broadly reviewed from its beginning in the seventies to present day. During this time, the sophistication of the ICF facilities and the suite of nuclear diagnostics have substantially evolved, generally a consequence of the efforts and experience gained on previous facilities. As the fusion yields have increased several orders of magnitude during these years, the quality of the nuclear-fusion-product measurements has improved significantly, facilitating an increased level of understanding about the physics governing the nuclear phase of an ICF implosion. The field of ICF has now entered an era where the fusion yields are high enough for nuclear measurements to provide spatial, temporal and spectral information, which have proven indispensable to understanding the performance of an ICF implosion. At the same time, the requirements on the nuclear diagnostics have also become more stringent. To put these measurements into context, this review starts by providing some historical remarks about the field of ICF and the role of nuclear diagnostics, followed by a brief overview of the basic physics that characterize the nuclear phase and performance of an ICF implosion. A technical discussion is subsequently presented of the neutron, gamma-ray, charged-particle and radiochemistry diagnostics that are, or have been, routinely used in the field of ICF. This discussion is followed by an elaboration of the current view of the next-generation nuclear diagnostics. Since the seventies, the overall progress made in the areas of nuclear diagnostics and scientific understanding of an ICF implosion has been enormous, and with the implementation of new high-fusion-yield facilities world-wide, the next-generation nuclear diagnostics will play an even more important role for decades to come.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Revisiting Bayesian constraints on the transport coefficients of QCD

Multistage models based on relativistic viscous hydrodynamics have proven successful in describing hadron measurements from relativistic nuclear collisions. These measurements are sensitive to the shear and the bulk viscosities of QCD and provide a unique opportunity to constrain these transport coefficients. Bayesian analyses can be used to obtain systematic constraints on the viscosities of QCD, through methodical model-to-data comparisons. In this manuscript, we discuss recent developments in Bayesian analyses of heavy ion collision data. Furthermore, we highlight the essential role of closure tests in validating a Bayesian analysis before comparison with measurements. We discuss the role of the emulator that is used as proxy for the multistage theoretical model. We use an ongoing Bayesian analysis of soft hadron measurements by the JETSCAPE Collaboration as context for the discussion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RPI LINAC refurbishment and upgrade project

The Electron Linear Accelerator at Rensselaer Polytechnic Institute (RPI) was constructed in the late 1950s and started operation in 1961 [1]. The facility was designed and used primarily for measurements of Nuclear Data (ND) with emphasis on the resonance energy region. As such it was designed to produce short pulses of neutrons (5-5000 ns) and equipped with detection stations at different neutron flight path distances from the source (15 m-250 m). When the LINAC started operation it was one of the most powerful accelerators in the world for high energy-resolution measurements in the resonance region. The original LINAC with some upgrades is still in operation but no longer provides world class capabilities for measurements with short pulses. In 2011 discussions between the RPI ND group, Naval Reactors, and the Nuclear Criticality Safety Program about the future of the LINAC concluded that maintaining the capability to perform world-class nuclear data measurements at RPI was desirable. To that end, it was decided to refurbish the facility and upgrade the accelerator capabilities to enable high accuracy measurement in the resonance region with narrow neutron pulse and high electron beam power. Located at a major US technical university, this project provides a needed US nuclear data capability for both research and education, and also includes external users and industrial applications.

43 PARTICLE ACCELERATORS↗

Bayesian inference of nuclear symmetry energy from measured and imagined neutron skin thickness in Sn 116 , 118 , 120 , 122 , 124 , 130 , 132 , Pb 208 , and Ca 48

The neutron skin thickness Δr np in heavy nuclei has been known as one of the most sensitive terrestrial probes of the nuclear symmetry energy E sym (ρ) around $\frac{2}{3}$ of the saturation density ρ 0 of nuclear matter. Existing neutron skin data mostly from hadronic observables suffer from large uncertainties and their extraction from experiments are often strongly model dependent. While waiting eagerly for the promised model-independent and high-precision neutron skin data for 208 Pb and 48 Ca from the parity-violating electron scattering experiments (PREX-II and CREX at JLab as well as MREX at MESA), within the Bayesian statistical framework using the Skyrme-Hartree-Fock model we infer the posterior probability distribution functions (PDFs) of the slope parameter L of the nuclear symmetry energy at ρ 0 from imagined Δr np ( 208 Pb)=0.15, 0.20, and 0.30 fm with a 1σ error bar of 0.02, 0.04, and 0.06 fm, respectively, as well as Δr np ( 48 Ca)=0.12, 0.15, and 0.25 fm, with different 1σ error bar of 0.01 and 0.02 fm, respectively. The results are compared with the PDFs of L inferred using the same approach from the available Δr np data for 116, 118, 120, 122, 124, 130, 132 Sn from hadronic probes. They are also compared with results from a recent Bayesian analysis of the radius and tidal deformability data of canonical neutron stars from GW170817 and NICER. The neutron skin data for Sn isotopes gives L = 45.5 $^{+ 26.5}_{-21.6}$ MeV surrounding its mean value or L = 53 . 4 $^{+ 18.6}_{ -29.5}$ MeV surrounding its maximum a posteriori value, respectively, with the latter smaller than but consistent with the L = 66 $^{+ 12}_{-20}$ MeV from the neutron star data within their 68% confidence intervals. We found that Δr np = 0.17 –0.18 fm in 208 Pb with an error bar of about 0.02 fm leads to a PDF of L compatible with that from analyzing the Sn data. To provide additionally useful information on L extracted from the Δr np of Sn isotopes, the experimental error bar of Δr np in 208 Pb should be at least smaller than 0.06 fm aimed by some current experiments. In addition, the Δr np ( 48 Ca) needs to be larger than 0.15 fm but smaller than 0.25 fm to be compatible with the Sn and/or neutron star results. To further improve our current knowledge about L and distinguish its PDFs in the examples considered, even higher precisions leading to significantly less than ±20 MeV error bars for L at 68% confidence level are necessary.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the Isolated Nuclear Two-Photon Decay in Ge 72

The nuclear two-photon or double-gamma (2 γ ) decay is a second-order electromagnetic process whereby a nucleus in an excited state emits two gamma rays simultaneously. To be able to directly measure the 2⁢ γ decay rate in the low-energy regime below the electron-positron pair-creation threshold, we combined the isochronous mode of a storage ring with Schottky resonant cavities. The newly developed technique can be applied to isomers with excitation energies down to ~100 keV and half-lives as short as ~10 ms. The half-life for the 2⁢ γ decay of the first-excited 0 + state in bare 72 Ge ions was determined to be 23.9(6) ms, which strongly deviates from expectations.

59 ≤ A ≤ 89↗

COHERENT Collaboration data release from the measurements of CsI[Na] response to nuclear recoils

The data release from the measurements of the CsI[Na] response to low energy nuclear recoils by the COHERENT collaboration. The release corresponds to the results published in 'D. Akimov et al 2022 JINST 17 P10034.' We share the data in the form of raw ADC waveforms, provide benchmark subselections and event reconstruction scripts to enhance the transparency and reproducibility of our results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of Pion and Muon Nuclear Capture at Rest on Argon in the LArIAT Experiment

We report the measurement of the final-state products of negative pion and muon nuclear capture at rest on argon by the LArIAT experiment at the Fermilab Test Beam Facility. We measure a population of isolated MeV-scale energy depositions, or blips, in 296 LArIAT events containing tracks from stopping low-momentum pions and muons. The average numbers of visible blips are measured to be 0.74 ± 0.19 and 1.86 ± 0.17 near muon and pion track endpoints, respectively. The 3.6⁢𝜎 statistically significant difference in blip content between muons and pions provides the first demonstration of a new method of pion-muon discrimination in neutrino liquid argon time projection chamber experiments. LArIAT Monte Carlo simulations predict substantially higher average blip counts for negative muon (1.22 ± 0.08) and pion (2.34 ± 0.09) nuclear captures. We attribute this difference to geant4’s inaccurate simulation of the nuclear capture process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗