Erratum to: Data Fusion to Support Integrated Nuclear Detonation Detection [Slides]
The original document (LA-UR-22-29547) contained minor equation errors that approximate correct equations that couple the multi-sensor, serial system detector thresholds for a seismic Rayleigh wave detector and an acoustic energy detector. Those errors appeared on slides 62-67. This erratum associates the following slides with the erroneous slides. The numbers of the erroneous slides are marked at the upper right in small text in orange. A result of those errors over-predict the performance of the two-sensor serial network, that is, the former document provides an optimistic estimate of system performance.
Special Nuclear Material Detection and Monitoring by Environmental Activation Products Detection
Through a series of measurements with a high purity germanium detector, we have established that the past presence of neutron emitting material can be detected by the decay of activation products in aluminum containers, tungsten shielding, and concrete floors even several days after last exposure. The time since last exposure can also be estimated by the gamma-ray detection rate. These findings may lead to interesting new CONOPS in the detection of illicit SNM or the verification of the absence (or presence) of SNM containing objects in facilities and/or transit even after the material has been removed.
System for detecting special nuclear materials
The present disclosure includes a radiological material detector having a convertor material that emits one or more photons in response to a capture of a neutron emitted by a radiological material; a photon detector arranged around the convertor material and that produces an electrical signal in response to a receipt of a photon; and a processor connected to the photon detector, the processor configured to determine the presence of a radiological material in response to a predetermined signature of the electrical signal produced at the photon detector. One or more detectors described herein can be integrated into a detection system that is suited for use in port monitoring, treaty compliance, and radiological material management activities.
Detection of nuclear gamma rays from Centaurus A
Results are reported for an observation of nuclear gamma rays in the energy range between 0.033 and 12.25 MeV from Centaurus A using a balloon-borne actively collimated NaI(Tl) crystal scintillation counter. The observing procedure is outlined, no systematic errors are found in the data, and power-law fits to the source's energy spectrum are attempted. A power law of approximately 0.86E to the -1.9 power photon/sq cm/sec per keV is shown to give an acceptable fit to the continuum, and the detection of two gamma-ray lines at 1.6 and 4.5 MeV, respectively, is discussed. It is found that the low-energy gamma-ray luminosity of Cen A is 9.4 by 10 to the 43rd power erg/sec for a distance of 5 Mpc and that Cen A is apparently variable in low-energy gamma radiation. It is suggested that the broad feature detected at 1.6 MeV may be due to three blended lines (possibly excited Ne-20, Mg-24, and Si-28), the 4.5-MeV line is most likely due to deexcitation of excited C-12, and the nuclear excitation results from either cosmic-ray bombardment of Cen A's interstellar medium or nucleosynthesis within the source.
Above-ground Antineutrino Detection for Nuclear Reactor Monitoring
Antineutrino monitoring of nuclear reactors has been demonstrated many times, however the technique has not as of yet been developed into a useful capability for treaty verification purposes. The most notable drawback is the current requirement that detectors be deployed underground, with at least several meters-water-equivalent of shielding from cosmic radiation. In addition, the deployment of liquid-based detector media presents a challenge in reactor facilities. We are currently developing a detector system that has the potential to operate above ground and circumvent deployment problems associated with a liquid detection media: the system is composed of segments of plastic scintillator surrounded by 6 LiF/ZnS:Ag. ZnS:Ag is a radio-luminescent phosphor used to detect the neutron capture products of lithium-6. Because of its long decay time compared to standard plastic scintillators, pulse-shape discrimination can be used to distinguish positron and neutron interactions resulting from the inverse beta decay (IBD) of antineutrinos within the detector volume, reducing both accidental and correlated backgrounds. Segmentation further reduces backgrounds by identifying the positron’s annihilation gammas, which are absent for most correlated and uncorrelated backgrounds. This work explores different configurations in order to maximize the size of the detector segments without reducing the intrinsic neutron detection efficiency. We believe this technology will ultimately be applicable to potential safeguards scenarios such as those recently described.
Compact endocavity diagnostic probes for nuclear radiation detection
This invention relates to the field of radiation imaging. In particular, the invention relates to an apparatus and a method for imaging tissue or an inanimate object using a novel probe that has an integrated solid-state semiconductor detector and complete readout electronics circuitry.
Characterization and Monte Carlo Simulations of a 4-Liter NaI Detection System for Use During Nuclear and Radiological Emergencies and for the Detection of Nuclear Materials
SCKCEN is engaged in research related to the use of a large volume NaI detection system for use during nuclear and radiological emergencies and for the detection of nuclear materials. As part of this effort a research activity is being carried out to determine the characteristics and build a Monte Carlo model of the available 4-liter NaI detector. These activities consist of (i) determination of energy resolution efficiency lower threshold background in laboratory conditions using well-characterized point sources; (ii) modeling of the detector by Monte Carlo methods and validation; (iii) determination of the response function by combining measurement and simulation results; (iv) characterization of the detector for contaminated surfaces by measurements and modeling; and (v) calibration of detector for dose rate measurements. This paper will focus on the results obtained so far concerning the Monte Carlo model and its validation with experimental data.
FPGA-based trigger system for the LUX dark matter experiment
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils resulting from interactions with dark matter particles. Signals from the detector are processed with an FPGA-based digital trigger system that analyzes the incoming data in real-time, with just a few microsecond latency. The system enables first pass selection of events of interest based on their pulse shape characteristics and 3D localization of the interactions. It has been shown to be >99% efficient in triggering on S2 signals induced by only few extracted liquid electrons. It is continuously and reliably operating since its full underground deployment in early 2013. This document is an overview of the systems capabilities, its inner workings, and its performance.
Ubiquitous Nuclear Threat Detection Final Report, Harvey Mudd College Engineering Clinic
The Lawrence Livermore National Labs clinic team was asked to design a repeatable, portable procedure that would incentivize participants to carry detectors that form a radiation sensor network along repeated paths, to precisely known locations and past known radioactive sources. To achieve these goals, the team designed day-long and week-long data collection procedures in the form of puzzle hunt events. The team also created an Android app in order to support this measurement campaign and foster engagement. A ground truth collection method was constructed and validated through repeated use. Information concerning effective deployment of the data-collection procedure was gathered for future iterations. Over the course of procedural testing, 6 de 17 HMC students participated and collected 250 hours of data. 3 deployments of the procedure were conducted in each semester. A total of 63 students participated and collected 300 hours of data over the year. Deployment 1: 16 students, Deployment 2: 17 students, Deployment 3: 8 users, ~18 active hours, Deployment 4: 4 students, ~10 active hours, and Deployment 5: 18 students, ~40 active hours.
Cavity-melt partitioning of refractory radionuclides and implications for detecting underground nuclear explosions
Not Available
Investigation of Active Interrogation Techniques to Detect Special Nuclear Material in Maritime Environments: Boarded Search of a Cargo Container Ship
Explore the source record for details and available documents.
Investigations of Active Interrogation Techniques to Detect Special Nuclear Material in Maritime Environments: Standoff Interrogation of Small and Medium Sized Cargo Ships
Explore the source record for details and available documents.
Purification and Improved Nuclear Radiation Detection of Tl 6 SI 4 Semiconductor
The wide-band-gap semiconductor Tl 6 SI 4 (2.14 eV) has high photon stopping power and is a promising material for detecting X-rays. To improve its photoresponse to low-flux γ-rays, material purification prior to crystal growth is crucial. In this contribution, we report effective purification protocols, impurity analysis, followed by synthesis and crystal growth, charge transport, and detector performance of large-sized Tl 6 SI 4 crystals. Purification methods of evaporation and zone refining were developed, and their high effectiveness was confirmed by impurity analysis via glow discharge mass spectrometry. Centimeter-sized single crystals were grown using the Bridgman method. The improved properties after material purification were confirmed by photoluminescence measurements. The energy of the valence band maximum of a Tl 6 SI 4 , measured with photoemission spectroscopy in air (PESA), is ~5.34 ± 0.05 eV. Detector devices fabricated from the single crystal exhibit a high resistivity of 5 × 10 12 Ω·cm. The detector shows potential photoresponse under 22.4 keV Ag Kα X-rays and 122 keV γ-rays from 57 Co. Spectroscopic energy resolution was achieved for 5.5 MeV α-particles from a 241 Am radiation source with a full width at half-maximum of 27% at an electric field intensity of 2500 V·cm -1 . On the foundation of its spectral response to 57 Co γ-rays, the electron mobility-lifetime product μeτe was estimated as 1.4 × 10 -5 cm 2 ·V -1 . Drift mobility measurements via a time-of-flight technique using spectral photoresponse induced by α-particles reveal a high electron mobility of 35 ± 7 cm 2 ·V -1 ·s -1 .
Frequency Resolved Detection of Nuclear Spin Optical Rotation at Low Field
Explore the source record for details and available documents.
Dark matter detection using nuclear magnetization in magnet with hyperfine interaction
Not Available
Direct detection of nuclear scattering of sub-Gev dark matter using molecular excitations
Not Available
False Data Injection Detection in Nuclear Systems Using Dynamic Noise Analysis
Not Available