Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multichannel analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Calibration of the Nimbus-7 SMMR. 2: Polarization mixing corrections

Averaged radiance data obtained over the oceans from the Nimbus-7 Scanning Multichannel Microwave Radiometer (SMMR) are used to produce an empirical correction algorithm for the polarization mixing which is inherent to the SMMR because of its fixed multichannel receiving horn and its scanning antenna dish. The algorithm, developed without the use of an ocean/atmosphere radiance model, also properly accounts for off center and scan independent polarization mixing, which were discovered after launch as a result of analyzing the aforementioned data. The radiance averaging consisted of collecting data for each beam position of each of the ten radiance channels of SMMR (nominal horizontal and vertical polarizations of the five SMMR wavelengths, 0.81, 1.4, 1.7, 2.8, and 4.6 cm) for about 300 orbits, subdividing the global ocean radiance data into 10 deg latitude bands and ascending (daytime) and descending (nighttime) orbits. This served to smooth out atmospheric and ocean surface variations in order to perform the polarization mixing analysis.

Gloersen, P.↗

NASA. Lewis Research Center Advanced Modulation and Coding Project: Introduction and overview

The Advanced Modulation and Coding Project at LeRC is sponsored by the Office of Space Science and Applications, Communications Division, Code EC, at NASA Headquarters and conducted by the Digital Systems Technology Branch of the Space Electronics Division. Advanced Modulation and Coding is one of three focused technology development projects within the branch's overall Processing and Switching Program. The program consists of industry contracts for developing proof-of-concept (POC) and demonstration model hardware, university grants for analyzing advanced techniques, and in-house integration and testing of performance verification and systems evaluation. The Advanced Modulation and Coding Project is broken into five elements: (1) bandwidth- and power-efficient modems; (2) high-speed codecs; (3) digital modems; (4) multichannel demodulators; and (5) very high-data-rate modems. At least one contract and one grant were awarded for each element.

Budinger, James M.↗

A high-sensitivity angle and energy dipersive multichannel electron momentum spectrometer with 2{pi} angle range

A high-sensitivity angle and energy dispersive multichannel electron momentum spectrometer with simultaneous detection in 2{pi} angle range is presented. A newly designed double half wedge and strip anode position-sensitive detector is employed to collect the ionized and scattered electrons passing through a 90 deg. sector, 2{pi} spherical electrostatic analyzer over azimuthal angle range of about 150 deg. for each. Experimental results on argon are presented to exhibit the performance of the spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the use of passive microwaves at 37 GHz

Recently a number of studies have been presented on the use of the 37 GHz channels of the Scanning Multichannel Microwave Radiometer (SMMR) on board the Nimbus 7 satellite, and on the synergisms between the SNMMR and the AVHRR (Advanced Very High Resolution Radiometer). The approaches are interesting but raise a number of questions on the validity of the interpretation of the results. A study to analyze the Microwave Polarization Difference Temperature (MPDT) in terms of sensitivity to surface and atmospheric parameters is presented. For this a radiative transfer model is used so as to depict the shortcomings of this index. Another approach, using lower frequencies is described and compared to the 37 GHz MPDT.

Kerr, Yann H.↗

Realtime Multichannel System for Beat to Beat QT Interval Variability

The measurement of beat-to-beat QT interval variability (QTV) shows clinical promise for identifying several types of cardiac pathology. However, until now, there has been no device capable of displaying, in real time on a beattobeat basis, changes in QTV in all 12 conventional leads in a continuously monitored patient. While several software programs have been designed to analyze QTV, heretofore, such programs have all involved only a few channels (at most) and/or have required laborious user interaction or offline calculations and postprocessing, limiting their clinical utility. This paper describes a PC-based ECG software program that in real time, acquires, analyzes and displays QTV and also PQ interval variability (PQV) in each of the eight independent channels that constitute the 12lead conventional ECG. The system also processes certain related signals that are derived from singular value decomposition and that help to reduce the overall effects of noise on the realtime QTV and PQV results.

Starc, Vito↗

Sea surface temperatures from the scanning multichannel microwave radiometer on Nimbus 7

Because of problems with the design and calibration of the scanning multichannel microwave radiometer (SMMR) on Nimbus 7, sea surface temperature (SST) algorithms had to be developed that corrected for instrument effects. Several stages of this development are reported here. The quality of the SST products from the final version is assessed. Thirty-four months of data have been analyzed; the average SST error is about 1.12 C over the whole globe. The error is smaller in the equatorial region and larger in the northern oceans. The main source of error is due to heating of the SMMR instrument. Specific problems in the design of the instrument are discussed. The details of the ST algorithms are given in an appendix.

Milman, A. S.↗

A multichannel fiber optic photometer present performance and future developments

A three channel photometer for simultaneous multicolor observations was designed with the aim of making possible highly efficient photometry of fast variable objects like cataclysmic variables. Experiences with this instrument over a period of three years are presented. Aspects of the special techniques applied are discussed with respect to high precision photometry. In particular, the use of fiber optics is critically analyzed. Finally, the development of a new photometer concept is discussed.

Barwig, H.↗

Rheoencephalographic and electroencephalographic measures of cognitive workload: analytical procedures

This investigation demonstrates the feasibility of mental workload assessment by rheoencephalographic (REG) and multichannel electroencephalographic (EEG) monitoring. During the performance of this research, unique testing, analytical and display procedures were developed for REG and EEG monitoring that extend the current state of the art and provide valuable tools for the study of cerebral circulatory and neural activity during cognition. REG records are analyzed to provide indices of the right and left hemisphere hemodynamic changes that take place during each test sequence. The EEG data are modeled using regression techniques and mathematically transformed to provide energy-density distributions of the scalp electrostatic field. These procedures permit concurrent REG/EEG cognitive testing not possible with current techniques. The introduction of a system for recording and analysis of cognitive REG/EEG test sequences facilitates the study of learning and memory disorders, dementia and other encephalopathies.

Arousal/physiology↗

Interannual variability of the spatial distribution of sea ice in the north polar region

The interannual variability of the monthly average spatial distributions of northern hemisphere sea ice was examined for the 1973-1987 period of the electrically scanning microwave radiometer on the Nimbus 5 satellite and the scanning multichannel microwave radiometer on the Nimbus 7 satellite passive microwave data record. Strong seasonal and spatial contrasts in the amount of interannual variability are mapped and identified. The maps and analyses provide a baseline against which future northern hemisphere sea ice distributions can be compared in the continuing attempt to analyze global climate and to determine whether or not significant climate change is occurring.

Parkinson, Claire L.↗

AIRS-Only Product in Giovanni for Exploring Up-to-Date AIRS Observation and Comparing with AIRS+AMSU Product

The NASA Goddard Earth Sciences Data and Information Services Center (GES DISC) has been the home of processing, archiving, and distribution services for the Atmospheric Infrared Sounder (AIRS) mission since its launch in 2002 for global observations of the atmospheric state. Giovanni, a Web-based application developed by the GES DISC, provides a simple and intuitive way to visualize, analyze, and access vast amounts of Earth science remote sensing data without having to download the data. Most important AIRS variables, including temperature and humidity profiles, outgoing longwave radiation, cloud properties, and trace gases, are available in Giovanni. AIRS is an instrument suite comprised of a hyperspectral infrared instrument (AIRS) and two multichannel microwave instruments, the Advanced Microwave Sounding Unit (AMSU) and the Humidity Sounder for Brazil (HSB). As HSB ceased operation in the very early stages of the AIRS mission, the AIRS project operates two parallel retrieval algorithms: one using both IR and MW measurements (AIRS+AMSU) and the other using only IR measurements (AIRS-only), which covers most of the mission duration. The AIRS+AMSU product is better quality, and the variables in Giovanni are from this product. However, generation of the AIRS+AMSU product has been suspended since the AMSU instrument anomaly occurred in late September 2016. To continue exploring up-to-date AIRS observations, the same set of variables from the AIRS-only product have been added to Giovanni by the GES DSIC. This will also support comparison of AIRS-only with AIRS+AMSU retrievals. In this presentation, we demonstrate the visualization of the AIRS-only product and plots/statistics of comparison with AIRS+AMSU product using Giovanni.

AIRS↗

Innovative Patient Room Lighting System with Integrated Spectrally Adaptive Control

In December of 2013, the U.S. Department of Energy’s SSL R&D Program released a Funding Opportunity Announcement (FOA), that for the first time, contained opportunities for comprehensive application-specific system development. The FOA included opportunities for two applications, one of which was a Patient Room. Philips Lighting Research North America, submitted a proposal for the Patient Room application, and was selected for the complete project award. The award amount was for $497,127, with a Philips Research co-funding commitment 165,709 dollars. The total project value was 662,836 dollars. This project sought to redefine lighting for the patient room application. The goal was to deliver an innovative LED patient suite (patient room and bathroom) lighting system solution that was 40% more energy-efficient than traditional fluorescent incumbent technologies, and would meet all the visual and non-visual needs of patients, caregivers and visitors, and improve the patient experience. State-of-the-art multichannel LED platforms and control technologies that would provide spectral tuning and become part of an intelligent, connected lighting system drove the solution. The project was scoped into four main task areas that included a) System Concept Creation, b) Identification of the Luminaire Portfolio, c) Development of the Connected Lighting Infrastructure, and d) System Performance Validation. Each of the four main tasks were completed and validated extensively over the course the 2 ½ year project. The system concept was created by first developing a lighting design that demonstrated best practices for patient room lighting – illuminance and uniformity for task performance, reduced glare, and convenient controls, in addition to giving patients control over the lighting in their environment. A framework was defined to deliver circadian support via software behaviors. Through that process luminaires were identified from the Philips portfolio that were adaptable – by their form, dimensions, and optical materials – to mix multicolor LED platforms uniformly and deliver target design lumen levels. The Blue Sky luminaire was selected for the patient bed area to give the illusion of skylight while providing white light on the patient bed. Luminaires used existing 2-channel tunable white LED boards, and newly developed 4-channel LED boards. Red-Orange, Blue, Green, and Blue-shifted Yellow LED chips were selected based on spectral characteristics and their ability to produce high quality white light. 4-channel Power over Ethernet (PoE) drivers were developed and firmware written so they would communicate with both 2- and 4-channel boards. These components formed the backbone of the connected lighting infrastructure. Software, flexible and nuanced in its complexity, was written to set behaviors for myriad lighting scenes in the room throughout the 24 hour day – and all could be overridden by manual controls. This included a dynamic tunable white program, three color changing automatic programs that simulated degrees of sunrise to sunset palettes, and an amber night lighting system that offered visual cues for postural stability to minimize the risk of falls. All programs were carefully designed to provide visual comfort for all occupants, support critical task performance for staff, and to support the patient’s 24hr rhythms. A full scale mockup room was constructed in the Philips Cambridge Lab. The lighting system was installed, tested and functionality demonstrated to ensure smooth operation of system components – luminaires, drivers, PoE switches, wall controls, patient remote, and daylight and occupancy sensors. How did the system perform? It met visual criteria, confirmed by calculations, simulations and measurements in the field. It met non-visual criteria, confirmed by setting circadian stimulus (CS) targets and performing calculations using the calculator developed by the Lighting Research Center. Finally, human factors validation studies were conducted to gain insight from real end users in the healthcare profession; surveys were administered, data analyzed, and audio comments captured. The general consensus was positive, with requests to pilot the system in their hospitals. The importance of the research completed under this grant is that it allowed the exploration and development of a unique lighting system, one that would deliver a blend of visual and non-visual criteria in patient room design for today’s healthcare environment. The research investigated the area of multichannel LED technology, multichannel Power over Ethernet (PoE) drivers and their integration with automatic and manual controls as a system – uncovering and meeting challenges along the way. It married visual needs of patients and staff with support for 24 hour rhythms, placing value on the wellbeing of the patient – while successfully saving energy over incumbent technologies. Indications are that the market is ready and willing to invest – multiple healthcare facilities are in line to pilot this system, recognizing its value beyond energy to patient and staff well-being. Its value to the public can best be expressed by a patient support coordinator who, after spending several hours in the room being immersed in the lighting, analyzing all its features, commented: “This re-writes lighting for healthcare”.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On the use of passive microwaves at 37 GHz in remote sensing of vegetation

Recently, a number of studies have investigated the use of the 37 GHz channels of the Nimbus-7 Scanning Multichannel Microwave Radiometer (SMMR) for vegetation monitoring and for studying synergisms between the SMMR and the NOAA Advanced Very High Resolution Radiometer (AVHRR). The approaches are promising but raise a number of issues concerning interpretation of the results, specifically on the relative effects of vegetation and other surface and atmospheric characteristics on the observed signal. This article analyzes the 37 GHz Microwave Polarization Difference Temperature (MPDT) in terms of its sensitivity to surface and atmospheric parameters. For this, a radiative transfer model is used which indicates some limitations of the MPDT index and suggests the importance of accounting for atmospheric effects in the data analysis. An alternative approach to the MPDT, including lower SMMR frequencies than 37 GHz, is discussed.

Kerr, Y. H.↗

A multichannel time-of-flight system for observation of energetic ions of multispecies generated from relativistic laser plasma

A multichannel time-of-flight (TOF) system was constructed to observe the ions generated from relativistic laser plasma, where the ions have polychromatic energies and multiple species. The TOF system is composed of a ten-channel scintillation detector array and an electromagnet that generates a magnetic field of 0-1.24 T. The magnet field enables us to analyze protons, deuterons, and full-stripped carbon ions to 50, 25, and 150 MeV, respectively. The system experimentally identified protons of 0.27-1.6 MeV energy and ions of a half specific charge (deuterons of 0.3-0.8 MeV and full-stripped carbons of 1.8-4.8 MeV). The measured TOF values agree well with the calculated values within the designed accuracy; {+-}2.5 ns for protons and {+-}5 ns for the others (d or C{sup 6+}) on each detector channel. Comparison of ion numbers detected by a track detector (CR-39) and the TOF system enabled us to obtain the number of ions detected on each scintillation counter with less than 16% error.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-126: Respiratory Gating Quality Assurance: A Simple Method to Achieve Millisecond Temporal Resolution

Purpose: Low temporal latency between a gating on/off signal and a linac beam on/off during respiratory gating is critical for patient safety. Although, a measurement of temporal lag is recommended by AAPM Task Group 142 for commissioning and annual quality assurance, there currently exists no published method. Here we describe a simple, inexpensive, and reliable method to precisely measure gating lag at millisecond resolutions. Methods: A Varian Real-time Position Management™ (RPM) gating simulator with rotating disk was modified with a resistive flex sensor (Spectra Symbol) attached to the gating box platform. A photon diode was placed at machine isocenter. Output signals of the flex sensor and diode were monitored with a multichannel oscilloscope (Tektronix™ DPO3014). Qualitative inspection of the gating window/beam on synchronicity were made by setting the linac to beam on/off at end-expiration, and the oscilloscope's temporal window to 100 ms to visually examine if the on/off timing was within the recommended 100-ms tolerance. Quantitative measurements were made by saving the signal traces and analyzing in MatLab™. The on and off of the beam signal were located and compared to the expected gating window (e.g. 40% to 60%). Four gating cycles were measured and compared. Results: On a Varian TrueBeam™ STx linac with RPM gating software, the average difference in synchronicity at beam on and off for four cycles was 14 ms (3 to 30 ms) and 11 ms (2 to 32 ms), respectively. For a Varian Clinac™ 21EX the average difference at beam on and off was 127 ms (122 to 133 ms) and 46 ms (42 to 49 ms), respectively. The uncertainty in the synchrony difference was estimated at ±6 ms. Conclusion: This new gating QA method is easy to implement and allows for fast qualitative inspection and quantitative measurements for commissioning and TG-142 annual QA measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultraviolet and Visible Emission Mechanisms in Astrophysics

The project involved the study of ultraviolet (UV) and visible emission mechanisms in astrophysical and atmospheric environments. In many situations, the emission is a direct consequence of a charge transferring collision of an ion with a neutral with capture of an electron to an excited state of the product ion. The process is also important in establishing the ionization and thermal balance of an astrophysical plasma. As little of the necessary collision data are available, the main thrust of the project was the calculation of total and state-selective charge transfer cross sections and rate coefficients for a very large number of collision systems. The data was computed using modern explicit techniques including the molecular-orbital close-coupling (MOCC), classical trajectory Monte Carlo (CTMC), and continuum distorted wave (CDW) methods. Estimates were also made in some instances using the multichannel Landau-Zener (MCLZ) and classical over-the-barrier (COB) models. Much of the data which has been computed has been formatted for inclusion in a charge transfer database on the World Wide Web (cfadc.phy.ornl.gov/astro/ps/data/). A considerable amount of data has been generated during the lifetime of the grant. Some of it has not been analyzed, but it will be as soon as possible, the data placed on our website, and papers ultimately written.

Stancil, Phillip C.↗

Collecting Real-Time Test Data

The TAXI Direct-to-Direct interface, in conjunction with the Disk Recording System (DRS) software developed by the SSC Boeing group, supplies a solution that provides higher integrity data that can be processed and made available to the customer with hours. The TAXI Direct-to-Direct interface is a special purpose interface solution developed by ISC for demultiplexing data from a Racal Storeplex (or equivalent) multichannel recorder onto one or more hard discs that reside in, and/or are controlled by, a personal computer (PC). (The name "TAXI" is the acronym for "transparent asynchronous transceiver interface"). The installation of the TAXI Direct-to Disk interface, in conjunction with other modifications, causes the transfer of data to be recorded directly to disk so it can be extracted and analyzed after the test.

Source record↗

Signature extraction of ocean pollutants by eigenvector transformation of remote spectra

Spectral signatures of suspended matter in the ocean are being extracted through characteristic vector analysis of remote ocean color data collected with MOCS (Multichannel Ocean Color Sensor). Spectral signatures appear to be obtainable through analyses of 'linear' clusters that appear on scatter diagrams associated with eigenvectors. Signatures associated with acid waste, sewage sludge, oil, and algae are presented. The application of vector analysis to two acid waste dumps overflown two years apart is examined in some detail. The relationships between eigenvectors and spectral signatures for these examples are analyzed. These cases demonstrate the value of characteristic vector analysis in remotely identifying pollutants in the ocean and in determining the consistency of their spectral signatures.

Grew, G. W.↗

Surface and atmosphere parameter maps from earth-orbiting radiometers

Earlier studies have shown that an earth-orbiting electrically scanned microwave radiometer (ESMR) is capable of inferring the extent, concentration, and age of sea ice; the extent, concentration, and thickness of lake ice; rainfall rates over oceans; surface wind speeds over open water; particle size distribution in the deep snow cover of continental ice sheets; and soil moisture content in unvegetated fields. Most other features of the surface of the earth and its atmosphere require multispectral imaging techniques to unscramble the combined contributions of the atmosphere and the surface. Multispectral extraction of surface parameters is analyzed on the basis of a pertinent equation in terms of the observed brightness temperature, the emissivity of the surface which depends on wavelength and various parameters, the sensible temperature of the surface, and the total atmospheric opacity which is also wavelength dependent. Implementation of the multispectral technique is examined. Properties of the surface of the earth and its atmosphere to be determined from a scanning multichannel microwave radiometer are tabulated.

Gloersen, P.↗