Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “motion planning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Limited range spatial load balancing in non-convex environments using sampling-based motion planners

This paper analyzes the limited range, spatial load balancing problem for agents deployed in non-convex environments and subject to differential constraints which restricts how the agents can move. First, the (unlimited range) spatial load balancing problem is introduced and the minimization problem with area constraints is defined. Then, to extend the problem for limited ranges, two cost functions and a sub-partition are defined. The problems are then analyzed and the results prove the existence of a partition that satisfies the area constraints. The non-convex environment makes the problem difficult to solve in continuous-space. Therefore, a probabilistic roadmap is used to approximate agents’ cells via a graph. A distributed algorithm is proven to converge to an approximate solution. Lastly, the convergence of the algorithm is shown in simulation.

42 ENGINEERING↗

Ultrasonic detection technology based on joint robot on composite component with complex surface

Some components have complex surface, such as the airplane wing and the shell of a pressure vessel etc. The quality of these components determines the reliability and safety of related equipment. Ultrasonic nondestructive detection is one of the main methods used for testing material defects at present. In order to improve the testing precision, the acoustic axis of the ultrasonic transducer should be consistent with the normal direction of the measured points. When we use joint robots, automatic ultrasonic scan along the component surface normal direction can be realized by motion trajectory planning and coordinate transformation etc. In order to express the defects accurately and truly, the robot position and the signal of the ultrasonic transducer should be synchronized.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WE-EF-210-08: BEST IN PHYSICS (IMAGING): 3D Prostate Segmentation in Ultrasound Images Using Patch-Based Anatomical Feature

Purpose: Transrectal ultrasound (TRUS) is the standard imaging modality for the image-guided prostate-cancer interventions (e.g., biopsy and brachytherapy) due to its versatility and real-time capability. Accurate segmentation of the prostate plays a key role in biopsy needle placement, treatment planning, and motion monitoring. As ultrasound images have a relatively low signal-to-noise ratio (SNR), automatic segmentation of the prostate is difficult. However, manual segmentation during biopsy or radiation therapy can be time consuming. We are developing an automated method to address this technical challenge. Methods: The proposed segmentation method consists of two major stages: the training stage and the segmentation stage. During the training stage, patch-based anatomical features are extracted from the registered training images with patient-specific information, because these training images have been mapped to the new patient’ images, and the more informative anatomical features are selected to train the kernel support vector machine (KSVM). During the segmentation stage, the selected anatomical features are extracted from newly acquired image as the input of the well-trained KSVM and the output of this trained KSVM is the segmented prostate of this patient. Results: This segmentation technique was validated with a clinical study of 10 patients. The accuracy of our approach was assessed using the manual segmentation. The mean volume Dice Overlap Coefficient was 89.7±2.3%, and the average surface distance was 1.52 ± 0.57 mm between our and manual segmentation, which indicate that the automatic segmentation method works well and could be used for 3D ultrasound-guided prostate intervention. Conclusion: We have developed a new prostate segmentation approach based on the optimal feature learning framework, demonstrated its clinical feasibility, and validated its accuracy with manual segmentation (gold standard). This segmentation technique could be a useful tool for image-guided interventions in prostate-cancer diagnosis and treatment. This research is supported in part by DOD PCRP Award W81XWH-13-1-0269, and National Cancer Institute (NCI) Grant CA114313.

60 APPLIED LIFE SCIENCES↗

WE-DE-BRA-10: Development of a Novel Scanning Beam Low-Energy Intraoperative Radiation Therapy (SBIORT) System for Pancreatic Cancer

Purpose: Developing a compact collimator system and validating a 3D surface imaging module for a scanning beam low-energy x-ray radiation therapy (SBIORT) system that enables delivery of non-uniform radiation dose to targets with irregular shapes intraoperatively. Methods: SBIORT consists of a low energy x-ray source, a custom compact collimator module, a robotic arm, and a 3D surface imaging module. The 3D surface imaging system (structure sensor) is utilized for treatment planning and motion monitoring of the surgical cavity. SBIORT can deliver non-uniform dose distributions by dynamically moving the x-ray source assembly along optimal paths with various collimator apertures. The compact collimator utilizes a dynamic shutter mechanism to form a variable square aperture. The accuracy and reproducibility of the collimator were evaluated using a high accuracy encoder and a high resolution camera platform. The dosimetrical characteristics of the collimator prototype were evaluated using EBT3 films with a Pantak Therapax unit. The accuracy and clinical feasibility of the 3D imaging system were evaluated using a phantom and a cadaver cavity. Results: The SBIORT collimator has a compact size: 66 mm diameter and 10 mm thickness with the maximum aperture of 20 mm. The mechanical experiment indicated the average accuracy of leaf position was 0.08 mm with a reproducibility of 0.25 mm at 95% confidence level. The dosimetry study indicated the collimator had a penumbra of 0.35 mm with a leaf transmission of 0.5%. 3D surface scans can be acquired in 5 seconds. The average difference between the acquired 3D surface and the ground truth is 1 mm with a standard deviation of 0.6 mm. Conclusion: This work demonstrates the feasibility of the compact collimator and 3D scanning system for the SBIORT. SBIORT is a way of delivering IORT with a compact system that requires minimum shielding of the procedure room. This research is supported by the University of Iowa Internal Funding Initiatives.

60 APPLIED LIFE SCIENCES↗

The control of space manipulators subject to spacecraft attitude control saturation limits

The motions of robotic manipulators mounted on spacecraft can disturb the spacecraft's positions and attitude. These disturbances can surpass the ability of the system's attitude control reaction jets to control them, for the disturbances increase as manipulator speeds increase. If the manipulator moves too quickly the resulting disturbances can exceed the saturation levels of the reaction jets, causing excessive spacecraft motions. A method for planning space manipulator's motions is presented, so that tasks can be performed as quickly as possible without saturating the system's attitude control jets.

Dubowsky, S.↗

Task decomposition for multilimbed robots to work in the reachable-but-unorientable space

Multilimbed industrial robots that have at least one arm and two or more legs are suggested for enlarging robot workspace in industrial automation. To plan the motion of a multilimbed robot, the arm-leg motion-coordination problem is raised and task decomposition is proposed to solve the problem; that is, a given task described by the destination position and orientation of the end-effector is decomposed into subtasks for arm manipulation and for leg locomotion, respectively. The former is defined as the end-effector position and orientation with respect to the legged main body, and the latter as the main-body position and orientation in the world coordinates. Three approaches are proposed for the task decomposition. The approaches are further evaluated in terms of energy consumption, from which an optimal approach can be selected.

Su, Chao↗

A Petri-net coordination model for an intelligent mobile robot

The authors present a Petri net model of the coordination level of an intelligent mobile robot system (IMRS). The purpose of this model is to specify the integration of the individual efforts on path planning, supervisory motion control, and vision systems that are necessary for the autonomous operation of the mobile robot in a structured dynamic environment. This is achieved by analytically modeling the various units of the system as Petri net transducers and explicitly representing the task precedence and information dependence among them. The model can also be used to simulate the task processing and to evaluate the efficiency of operations and the responsibility of decisions in the coordination level of the IMRS. Some simulation results on the task processing and learning are presented.

Wang, F.-Y.↗

Task decomposition for a multilimbed robot to work in reachable but unorientable space

Robot manipulators installed on legged mobile platforms are suggested for enlarging robot workspace. To plan the motion of such a system, the arm-platform motion coordination problem is raised, and a task decomposition is proposed to solve the problem. A given task described by the destination position and orientation of the end effector is decomposed into subtasks for arm manipulation and for platform configuration, respectively. The former is defined as the end-effector position and orientation with respect to the platform, and the latter as the platform position and orientation in the base coordinates. Three approaches are proposed for the task decomposition. The approaches are also evaluated in terms of the displacements, from which an optimal approach can be selected.

Su, Chau↗

Simulation of the coupled multi-spacecraft control testbed at the Marshall Space Flight Center

The capture and berthing of a controlled spacecraft using a robotic manipulator is an important technology for future space missions and is presently being considered as a backup option for direct docking of the Space Shuttle to the Space Station during assembly missions. The dynamics and control of spacecraft configurations that are manipulator-coupled with each spacecraft having independent attitude control systems is not well understood and NASA is actively involved in both analytic research on this three dimensional control problem for manipulator coupled active spacecraft and experimental research using a two dimensional ground based facility at the Marshall Space Flight Center (MSFC). This paper first describes the MSFC testbed and then describes a two link arm simulator that has been developed to facilitate control theory development and test planning. The motion of the arms and the payload is controlled by motors located at the shoulder, elbow, and wrist.

Ghosh, Dave↗

Time Optimal Trajectory Planning in Dynamic Environments

A method is presented for planning the motion of a robot in a dynamic environment by computing a trajectory that avoids all obstacles and that satisfies the robot dynamics and its actuator constraints. This method consists of two steps -- the computation of the trajectory and its refinement with a dynamic optimization.

Robotics Velocity Obstacle↗

High gain antenna pointing on the Mars Exploration Rovers

This paper describes the algorithm used to point the high gain antennae on NASA/JPL's Mars Exploration Rovers. The gimballed antennae must track the Earth as it moves across the Martian sky during communication sessions. The algorithm accounts for (1) gimbal range limitations, (2) obstructions both on the rover and in the surrounding environment, (3) kinematic singularities in the gimbal design, and (4) up to two joint-space solutions for a given pointing direction. The algorithm computes the intercept-times for each of the occlusions and chooses the jointspace solution that provides the longest track time before encountering an occlusion. Upon encountering an occlusion, the pointing algorithm automatically switches to the other joint-space solution if it is not also occluded. The algorithm has successfully provided flop-free pointing for both rovers throughout the mission.

motion planning↗

High Gain Antenna Pointing on the Mars Exploration Rovers

This paper describes the algorithm used to point the high gain antennae on NASA/JPL's Mars exploration rovers. Each rover's gimballed antenna must track the Earth as it moves across the Martian sky during communication sessions. The pointing algorithm accounts for obstacles to the line-of-sight posed by (1) features on the rover and in the surrounding environment (2) gimbal range limitations, and (3) kinematic singularities in the gimbal mechanism. The algorithm treats all obstacles with a generalized approach that computes the intercept-times to each obstacle. Where possible, the algorithm takes advantage of pairs of joint-space solutions arising from the mechanism design. The algorithm chooses the solution that provides the longest obstruction-free tracking time. Upon encountering an obstacle, the algorithm automatically switches to the other solution if it is not also obstructed. This algorithm has successfully provided obstruction-free pointing for both rovers throughout the mission.

inverse kinematics↗

Motion Analysis of 100 Mediastinal Lymph Nodes: Potential Pitfalls in Treatment Planning and Adaptive Strategies

Purpose: The motion of mediastinal lymph nodes may undermine local control with involved-field radiotherapy. We studied patterns of nodal and tumor motion in 41 patients with lung cancer. Methods and Materials: Four-dimensional (4D) computed tomography planning scans were retrospectively evaluated to identify patients with clearly visible mediastinal lymph nodes. One hundred nodes from 14 patients with Stage I and 27 patients with Stage III were manually contoured in all 4D computed tomography respiratory phases. Motion was derived from changes in the nodal center-of-mass position. Primary tumors were also delineated in all phases for 16 patients with Stage III disease. Statistical analysis included a multivariate mixed-effects model of grouped data. Results: Average 3D nodal motion during quiet breathing was 0.68 cm (range, 0.17-1.64 cm); 77% moved greater than 0.5 cm, and 10% moved greater than 1.0 cm. Motion was greatest in the lower mediastinum (p = 0.002), and nodes measuring 2 cm or greater in diameter showed motion similar to that in smaller nodes. In 11 of 16 patients studied, at least one node moved more than the corresponding primary tumor. No association between 3D primary tumor motion and nodal motion was observed. For mobile primary tumors, phase offsets between the primary tumor and nodes of two or more and three or more phases were observed for 33% and 12% of nodes, respectively. Conclusions: Mediastinal nodal motion is common, with phase offsets seen between the primary tumor and different nodes in the same patient. Patient-specific information is needed to ensure geometric coverage, and adaptive strategies based solely on the primary tumor may be misleading.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-C-17A-06: Evaluating IMRT Plan Deliverability Via PTV Shape and MLC Motion

Purpose: For step-and-shoot intensity-modulated radiation therapy (IMRT) plans, the dosimetry and deliverability can be affected by the number and shape of the segments used. Thus, plan deliverability is likely related to target volume and shape. We investigated whether the sphericity of target volumes and the previously proposed Modulation Complexity Score (MCS) could be used together to improve the detection of IMRT fields that failed quality assurance (QA). Methods: 526 and 353 IMRT fields from 32 prostate and 28 head-and-neck (H'N) patients, respectively, were analyzed. MCS was used to quantify the complexity of multi-leaf collimator shapes and motion patterns for each field. Sphericity was calculated using the surface area and volume of each patient’s planning target volume (PTV). Logistic regression models with MCS-alone or MCS and sphericity terms were fit to PlanUNC IMRT pass/fail results (5% dose difference, 4mm distance-to-agreement criteria) using SAS 9.3 (Cary, NC). Model concordance, discordance and area under the curve (AUC) were used to quantify model accuracy. Results: Mean (±1 standard deviation) MCS for prostate and H'N were 0.58(±0.15) and 0.40 (±0.14), respectively. Mean sphericity scores were 0.75(±0.05) for prostate and 0.63 (±0.12) for H'N. Both metrics were significantly different between treatment locations (p<0.01, Wilcoxon Rank Sum Test) indicating greater complexity in shape and variations for H'N PTVs. For prostate, concordance, discordance and AUC using MCS alone were 80.8%, 18.7% and 0.811. Including sphericity in the model improved these to 81.7%, 17.7% and 0.820. For H'N, the original concordance, discordance and AUC were of 72.9%, 26.9% and 0.729. Including sphericity into the model improved these metrics to 76.5%, 23.2% and 0.729. Conclusion: Sphericity provides a quantitative measure of PTV shape. While improvement in IMRT QA failure detection was modest for both prostate and H'N plans, including sphericity in the model does improve IMRT field failure prediction.

60 APPLIED LIFE SCIENCES↗

3-D advanced gas-cooled nuclear reactor fuel channel reconstruction using structure-from-motion - 110

During planned, periodic outages, a selection of fuel channels within the UK fleet of Advanced Gas-cooled Reactor (AGR) cores are inspected using specialist tools which record video footage and other sensory data for each channel which undergoes inspection. Current visualization techniques comprise of manually produced montages by inspection engineers of points of interest (i.e. structural defects) and 2-D panoramic images of the fuel channels automatically produced using bespoke image stitching software. Both techniques however provide limited structural information due to the loss of depth data as a result of the image formation process. By recovering the depth information from the footage, a 3D model could be constructed and subsequently, allow for more accurate profiling of specific defects observed during inspection in addition to obtaining the fuel channels structure using existing footage. This work explores the preliminary application of a 3-D visualization technique known as Structure-from-Motion (SfM) which aims to obtain 3-D information by exploiting image correspondences across multiple viewpoints of the same scene in the RVI footage. This paper investigates the difficulties of applying state-of-the-art SfM to RVI footage and we present new techniques to improve feature correspondence searching in repetitive, nondescript environments. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The motional Stark effect diagnostic for ITER

An overview of the plans for the motional Stark effect (MSE) diagnostic installation on the International Thermonuclear Experimental Reactor (ITER) is presented. The MSE diagnostic uniquely provides spatially localized magnetic field measurements inside the plasma. These are used to constrain equilibrium reconstructions to determine q(r), the safety factor as a function of minor radius. Meeting the system requirements to deliver q-profiles and related quantities with the specified radial resolution of 20 points over the minor radius, 10 ms time resolution, and better than 10% accuracy is challenging. MSE systems observe the D/H-α emission near 656.3 nm from neutral beams. As the beam atoms traverse the magnetic field, B⃗, at high velocity, v⃗, they experience a Lorentz electric field, v⃗×B⃗, which causes the spectral emission to be split and polarized due to the Stark effect. Traditional MSE-LP (line polarization) measurements determine the direction of the magnetic field in the observation volume using polarimetric analysis of the detected light. The harsh conditions of ITER are expected to deposit thin films of contaminants on the first mirror, which would alter the polarization state of reflected light significantly. On ITER, the combination of high magnetic field strength and high energy beams makes the Stark spectrum resolution suitable for the determination of the magnetic field magnitude from the line shift, so this approach has been selected. Every aspect of the measurement system must be planned for the burning plasma environment and carefully analyzed ahead of time. Current status and plans for the system are presented.

Instruments & Instrumentation↗