Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “monochromators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The direct and scattered solar flux within the stratosphere

Solar ultraviolet flux data obtained within the atmosphere by using Fastie-Ebert double monochromators carried on a balloon-borne gondola and a rocket payload are analyzed. Both the direct and scattered components of the solar ultraviolet flux at wavelengths from 190 to 320 nm are measured at the balloon float altitude of 40 km. The nearly identical spectrometer carried on the rocket flight measures the direct solar flux from 60 to 38 km during a parachute descent. The ozone column content above 40 km and the temperature profile and ozone density below 40 km are deduced using the scattered and direct solar flux components. It is shown that the Nimbus 7 solar flux data are consistent with the present data and with the ozone absorption cross sections of Inn and Tanake (1959). The calculated and measured values of the scattered solar flux are found to agree fairly closely.

Herman, J. R.↗

Study of communications data compression methods

A simple monochrome conditional replenishment system was extended to higher compression and to higher motion levels, by incorporating spatially adaptive quantizers and field repeating. Conditional replenishment combines intraframe and interframe compression, and both areas are investigated. The gain of conditional replenishment depends on the fraction of the image changing, since only changed parts of the image need to be transmitted. If the transmission rate is set so that only one fourth of the image can be transmitted in each field, greater change fractions will overload the system. A computer simulation was prepared which incorporated (1) field repeat of changes, (2) a variable change threshold, (3) frame repeat for high change, and (4) two mode, variable rate Hadamard intraframe quantizers. The field repeat gives 2:1 compression in moving areas without noticeable degradation. Variable change threshold allows some flexibility in dealing with varying change rates, but the threshold variation must be limited for acceptable performance.

Jones, H. W.↗

Detection and recognition of simple spatial forms

A model of human visual sensitivity to spatial patterns is constructed. The model predicts the visibility and discriminability of arbitrary two-dimensional monochrome images. The image is analyzed by a large array of linear feature sensors, which differ in spatial frequency, phase, orientation, and position in the visual field. All sensors have one octave frequency bandwidths, and increase in size linearly with eccentricity. Sensor responses are processed by an ideal Bayesian classifier, subject to uncertainty. The performance of the model is compared to that of the human observer in detecting and discriminating some simple images.

Watson, A. B.↗

Quantum efficiency of opaque CsI photocathodes with channel electron multiplier arrays in the extreme and far ultraviolet

The arrays are overcoated with a CsI photocathode in the VUV. The measurements are part of the development program for the Extreme Ultraviolet Explorer. Monochromatic light from a hollow cathode discharge source passing through a McPherson grazing incidence monochromator is used to illuminate the CsI photocathode. The beam diameter is kept small (approximately 2 mm) to confine it within the individual thickness strips. A bias grid is used to produce a 50-V/mm electric field to guarantee collection of all photoelectrons emitted by the CEMA (channel electron multiplier array) webbing. The CEMAs are operated with a gain of 2-3 x 10 to the 6th and are moderately saturated. A channeltron secondary transfer standard is used to determine the absolute QE in the EUV, whereas an NBS calibrated windowed photodiode is used to measure the FUV absolute QE. It is noted that the CsI gives a factor of 3 increase in the QE in the EUV and a factor of 50-5000 in the FUV.

Martin, C.↗

Atomic photoionization

After a brief historical review, this work discusses in detail the experimental techniques available for the investigation of photoionization processes, presents results on typical atoms, and examines some of the problems yet unsolved; in general, the discussion is concerned primarily with the photoionization of atoms in the spectral range from ionization threshold to about 100 A. The examination of experimental techniques treats such topics as light sources, monochromators and spectrographs, absorption and photoionization cells, branching-ratio studies, and electron-impact 'photoionization'. Photoionization measurements are discussed with reference to total and partial photoionization cross sections.

Samson, J. A. R.↗

Separation of time-averaged turbulence components by laser-induced fluorescence

A resonant Doppler velocimeter technique is introduced for time averaged gas flow turbulence fluctuation measurements. A monochrome laser beam is shone through a flow seeded with an atomic or molecular species that has an absorption frequency to which the laser is tuned. The resulting fluorescence is recorded by a detector, and the Doppler shift of the absorption frequency yields the velocity component of the flow in the direction of the beam. Static temperature and pressure data are available from the spectroscopic absoption line broadening. An analytical formulation of the laser-induced fluorescence intensity is defined and related to the velocity, temperature, and pressure. Comparison with data from a Na-seeded laminar supersonic jet demonstrates the accuracy of both the technique and model. Varying the pump laser frequency allows determination of the mean square velocity, temperature, and pressure fluctuations.

Cheng, S.↗

Linewidth studies on the the NI(4S-4P) resonance multiplet

Doppler broadening of the 8691, 8212, and 1200-A multiplet lines of N I is investigated experimentally, and its implications for the interpretation of the earth's 1200-A UV dayglow are considered. A regulated 100-eV, 1-mA electron beam is passed through N2 at 300 K and about 0.0005 torr flowing through a collision chamber within a UHV system, and the radiation emitted is observed with a temperature-stabilized short-focal length monochromator with a bandpass of 0.2 A in the IR and an effective UV resolution (in second-order operation with a 3600-groove/mm plane grating) of about 0.04 A. Both the IR and VUV lines are found to be broadened to about 25 times the thermal Doppler linewidth, with the IR transitions accounting for more than half of the total N(4P) cross section at 100 eV. The kinetic energy of the N(4P) atoms produced by dissociative excitation is such that their 1200-A resonance radiation (2p2 3s4P - 2p3 4SO) would be optically thin in the upper atmosphere, contrary to what has been observed. A need to revise some aspects of current UV-dayglow models is identified.

Erdman, P. W.↗

X-ray spectrographs using radial groove gratings

A high efficiency spectrograph design for the EUV and soft X rays is presented. This grazing incidence system uses a plane surface reflection grating with rulings that are radial, like the spokes of a wheel. The grating is placed in a beam of light that is converging to a focus. The single reflection off the grating is in the conical diffraction mount ensuring maximum performance from the system. Aberrations and performance levels are discussed. The gratings can be manufactured with existing ruling engines. Sample applications to an X-ray monochromator and an EUV stellar spectrograph are discussed.

Cash, W. C., Jr.↗

Calibration of diode laser spectra using a confocal etalon

The dual-beam diode laser spectrometer described by Jennings (1980) is adapted to use a 50-cm confocal etalon for frequency calibration. The collimated radiation from the laser is split at a wedged ZnSe window, and the reference beam is then focused at the midpoint of the etalon length. After the etalon, the reference beam is recollimated and continues its regular path to the monochromator and detectors. An aperture is placed before the etalon in order to limit the entrance beam diameter to approximately 5 mm. Both ends of the etalon are furnished with two-axis adjustments. Initial alignment is achieved using an He-Ne laser, and final optimization involves adjustment of the cavity length as well as the etalon pitch and yaw. The 50-cm confocal etalon produces fringes separated by 150 MHz (0.005/cm). With the aid of a CO2 laser, it is found to have fringe widths (FWHM) of 2 MHz. The confocal etalon makes it possible to improve the accuracy of relative frequency measurements in diode laser spectra and to check the spectral purity and stability of the laser during the recording of spectra.

Jennings, D. E.↗

Electron escape depth variation in thin SiO2 films measured with variable photon energy

A double crystal monochromator at the Stanford Synchrotron Radiation Laboratory is used to study the Si/SiO2 interface, using photon energies of hv = 1950-3700 eV. This photon energy range allows interfaces to be observed through oxide layers 50 A thick or more. Variations in electron escape depth and/or oxide density as a function of distance from the interface are observed over the entire kinetic energy range (100-3600 eV). These differences are attributed to a strained oxide layer near the interface.

Hecht, M. H.↗

Video compression using conditional replenishment and motion prediction

A study of a low-rate monochrome video compression system is presentd in this paper. This system is a conditional-replenishment coder that uses two-dimensional Walsh-transform coding within each video frame. The conditional-replenishment algorithm works by transmitting only the portions of an image that are changing in time. This system is augmented with a motn-prediction algorithm that measures spatial dispalcement parameters from frame to frame, and codes the data using these parameters. A comparison is made between the conditional-replenishment system with, and without, the motion-predictinalgorthm. Subsampling in time is ued to maintain the data rate rate at a fixed value. Average bit rates of 1 bit/picture element (pel) to 1/16 bit/pel are considered. The resultant performance of the compression simulations is presented in terms of the average frame rates produced.

Hein, D. N.↗

Coding for Efficient Image Transmission

NASA publication second in series on data-coding techniques for noiseless channels. Techniques used even in noisy channels, provided data further processed with Reed-Solomon or other error-correcting code. Techniques discussed in context of transmission of monochrome imagery from Voyager II spacecraft but applicable to other streams of data. Objective of this type coding to "compress" data; that is, to transmit using as few bits as possible by omitting as much as possible of portion of information repeated in subsequent samples (or picture elements).

Rice, R. F.↗

The organic aerosols of Titan

The optical properties and chemical composition of thiolin, an organic solid synthesized by high-energy-electron irradiation in a plasma discharge (Sagan et al., 1984) to simulate the high-altitude aerosols of Titan, are investigated experimentally using monochromators, ellipsometers, and spectrometers (on thin films deposited by continuous dc discharge) and sequential and nonsequential pyrolytic gas chromatography/mass spectrometry (of the volatile component), respectively. The results are presented in tables and graphs and characterized. The real and imaginary elements of the complex refractive index in the visible are estimated as 1.65 and 0.004-0.08, respectively, in agreement with observations of Titan, and the IR absorption features include the nitrile band at 4.6 microns. The molecules identified in the volatile part of thiolin include complex species considered important in theoretical models of the origin of life on earth.

Khare, B. N.↗

Computer graphics applications to crew displays

Astronauts are provided much data and information via the monochrome CRT displays on the orbiter. For this project two areas were investigated for the possible introduction of computer graphics to enhance and extend the utility of these displays. One involved reviewing the current orbiter displays and identifying those which could be improved via computer graphics. As an example, the tabular data on electrical power distribution and control was enhanced by the addition of color and bar charts. The other dealt with the development of an aid to berthing a payload with the Remote Manipulator System (RMS). This aid consists of a graphics display of the top, front and side views of the payload and cargo bay and point of resolution (POR) position and attitude data for the current location of the payload. The initial implementation was on an IBM PC clone. The demonstration software installed in the Johnson Space Center Manipulator Development Facility (MD) was reviewed. Due to current hardware limitations, the MDF verision is slow, i.e., about a 40+ seond update rate and, hence, not real-time. Despite this fact, the evaluation of this additional visual cue as an RMS operator aid indicates that this display, with modifications for speed, etc., can assist the crew. Further development is appropriate.

Wyzkoski, J.↗

Improved memory loading techniques for the TSRV display system

A recent upgrade of the TSRV research flight system at NASA Langley Research Center retained the original monochrome display system. However, the display memory loading equipment was replaced requiring design and development of new methods of performing this task. This paper describes the new techniques developed to load memory in the display system. An outdated paper tape method for loading the BOOTSTRAP control program was replaced by EPROM storage of the characters contained on the tape. Rather than move a tape past an optical reader, a counter was implemented which steps sequentially through EPROM addresses and presents the same data to the loader circuitry. A cumbersome cassette tape method for loading the applications software was replaced with a floppy disk method using a microprocessor terminal installed as part of the upgrade. The cassette memory image was transferred to disk and a specific software loader was written for the terminal which duplicates the function of the cassette loader.

Easley, W. C.↗

Surface sensitive photoemission EXAFS: A new structural tool

A new technique for surface EXAFS has been developed. In this technique the absorption fine structure is observed by monitoring the photoelectrons emitted from core levels as a function of photon energy. The surface sensitivity is achieved by detecting elastic photoelectrons that escape to the vacuum from a few atomic layers near the surface. EXAFS from Mn 3p and F2s outer core levels in MnF2 were measured, the results were compared with transmission EXAFS from Mn ls core level and good agreement was found. This development is significant because: (1) almost all elements have suitable core levels of low binding energy; (2) since photopeaks from adjacent core levels do not cross as the photon energy is varied, the limitations imposed on other surface EXAFS techniques by this interference is removed. Auger electrons, which have fixed kinetic energies and so can cross photopeaks, will generally have low energies if they originate from outer core levels and be unlikely to appear in the EXAFS region of kinetic energies, i.e., in excess of about 50 eV; (3) VUV light is used, which greatly extends the usable range of photon energies; (4) more than one element in a solid may be studied with the same monochromator. The experiments were carried out on the VUV beam line U14A at NSLS.

Choudhary, K. M.↗

Set-up and demonstration of a Low Energy Electron Magnetometer (LEEM)

Described are the design, construction and test results of a Low Energy Electron Magnetometer (LEEM). The electron source is a commercial electron gun capable of providing several microamperes of electron beam. These electrons, after acceleration through a selected potential difference of 100-300 volts, are sent through two 30 degree second-order focussing parallel plate electrostatic analyzers. The first analyzer acts as a monochromator located in the field-free space. It is capable of providing energy resolution of better than 10 to the -3 power. The second analyzer, located in the test field region, acts as the detector for electrons deflected by the test field. The entire magnetometer system is expected to have a resolution of 1 part in 1000 or better.

Rayborn, G. H.↗

Limb-atmospheric infrared spectrum observed on the satellite Ohzora

The Institute of Space and Astronautical Science (ISAS) launched the 9th scientific satellite Ohzora at 17:00 JST on February 14, 1984. This satellite bears the spectrometer, which measures the infrared spectrum of the solar radiation passing the limb atmosphere in the wavelength region of 2 to 10 m. The spectrometer is based on multichannel spectroscopy by using image sensors. Since the wavelength is scanned electronically, it can measure the spectrum unaffected by the satellite motion. A definite axis, i.e., the Z-axis of the satellite, which coincides to the optical axis of the spectrometer, is controlled to the direction of the Sun, and the finer control to introduce the solar light into the spectrometer is made with a 2-axes-controlled mirror. This solar tracking equipment is derived fast enough to measure the spectra in a moment after sunrise. The solar light introduced into the spectrometer is focused on the slits of the monochromators (f=100mm). For better altitude resolution, the horizontal slit is also used with the vertical slit, which is used for the separation of the dispersion. The dispersion light is detected with the pyroelectric array sensors. To obtain maximum dynamic range and spectral resolution, the three-stage polychromator is used.

Matsuzaki, A.↗