Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mirror assembly”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Volume 1. Preliminary design study: AXAF x ray calibration spectrometers. Volume 2. Revised preliminary design study: AXAF x ray calibration spectrometers

The objective of this work was to provide a preliminary design concept for a Flux Monitor Spectrometer (FMS) for use at the X Ray Astrophysics Facility (XRAF) during High Resolution Mirror Assembly (HRMA) testing that met the requirements of SAO-AXAF-88-025 dated July 31, 1991. The calibration test team determined that the spectral resolution of the FMS had to be greater than or equal to twice that of all the AXAF spectrometers throughout the 0.1 to 10 KeV range of x-ray energies. Since this effectively doubled the resolution required by SAO-AXAF-88-025, a change order was approved by the Marshall Space Flight Center and given to Radiation Sciences to revise their study.

Source record↗

VETA-1 x ray detection system

The alignment and X-ray imaging performance of the Advanced X-ray Astrophysics Facility (AXAF) Verification Engineering Test Article-I (VETA-I) was measured by the VETA-I X-Ray Detection System (VXDS). The VXDS was based on the X-ray detection system utilized in the AXAF Technology Mirror Assembly (TMA) program, upgraded to meet the more stringent requirements of the VETA-I test program. The VXDS includes two types of X-ray detectors: (1) a High Resolution Imager (HRI) which provides X-ray imaging capabilities, and (2) sealed and flow proportional counters which, in conjunction with apertures of various types and precision translation stages, provide the most accurate measurement of VETA-I performance. Herein we give an overview of the VXDS hardware including X-ray detectors, translation stages, apertures, proportional counters and flow counter gas supply system and associated electronics. We also describe the installation of the VXDS into the Marshall Space Flight Center (MSFC) X-Ray Calibration Facility (XRCF). We discuss in detail the design and performance of those elements of the VXDS which have not been discussed elsewhere; translation systems, flow counter gas supply system, apertures and thermal monitoring system.

Podgorski, W. A.↗

Precision of the calibration of the AXAF engineering test article (VETA) mirrors

Measurements of the VETA encircled energies have been performed at 5 energies within 16 radii ranging from 0.05 to 200 arcseconds. We report here on the analysis of the accuracy of those measurements. A common 'error tree' structure applies, and we present representative numbers for the larger terms. At 0.277, 1.5, and 2.07 keV, and for radii of 3 arcsec and larger, our measurements have estimated 1 sigma errors of 0.6 to 1.5 percent. Effects of measurement statistics and of the VETA test mount limit the accuracy at smaller angles, and modulation by the counter window support structure together with the imperfect position repeatability limit the accuracy for the 0.93 and 2.3 keV energies. We expect to mitigate these limitations when calibrating the complete AXAF flight mirror assembly.

Schwartz, D. A.↗

Precision of the calibration of the AXAF Engineering Test Article (VETA) mirrors

Measurements of the VETA encircled energies have been performed at 5 energies within 16 radii ranging from 0.05 to 200 arcseconds. We report here on the analysis of the accuracy of those measurements. A common 'error tree' structure applies, and we present representative numbers for the larger terms. At 0.277, 1.5, and 2.07 keV, and for radii of 3 arcsec and larger, our measurements have estimated 1 sigma errors of 0.6 to 1.5 percent. Effects of measurement statistics and of the VETA test mount limit the accuracy at smaller angles, and modulation by the counter window support structure together with the imperfect position repeatability limit the accuracy for the 0.93 and 2.3 keV energies. We expect to mitigate these limitations when calibrating the complete AXAF flight mirror assembly.

Schwartz, D. A.↗

Ultra-high, resolution, modular optical angle encoder for space-based opto-mechanical applications

A 27-bit optical encoder using a novel patent pending technology has been developed by the MicroE Development Center of BEI Sensors & Systems Company and tested by the Sensor Systems Group (SSG) Inc., in a positioning and stabilization mirror assembly (PSMA) designed and constructed under a grant from the Marshall Space Flight Center. Test results verified performance within the specifications of the PSMA.

Luther, Holger↗

Uses of continuum radiation in the AXAF calibration

X-ray calibration of the Advanced X-ray Astrophysics Facility (AXAF) observatory at the MSFC X-Ray Calibration Facility (XRCF) made novel use of the x-ray continuum from a conventional electron-impact source. Taking advantage of the good spectral resolution of solid-state detectors, continuum measurements proved advantageous in calibrating the effective area of AXAF's High-Resolution Mirror Assembly (HRMA) and in verifying its alignment to the XRCF's optical axis.

Kolodziejczak, J. J.↗

Development of a mirror pointing mechanism for an atmospheric gas measurement instrument

Development of the Open Path Tunable Infrared Monitor of the Atmosphere (OPTIMA) instrument involved designing a pair of motion systems that could maintain a precise alignment and spatial distance between two mirrors installed on the NASA DC-8 research laboratory aircraft. This is the first airborne optical instrument that allows direct measurement of the gases in the freestream airflow on the exterior of the aircraft. One mirror is mounted within a specially constructed open port cavity in the cabin of the aircraft and the second is mounted 6 meters away on top of the inboard port side (number 2) engine pylon. Three co-aligned laser beams are reflected between the two mirrors 64 times in a Herriott pattern. The resulting sample path length of 384 meters is used to perform a spectral absorption analysis of the airflow between the mirrors. To compensate for normal wing movement and engine oscillations both mirrors were designed as continuously driven mechanisms to maintain alignment within allowable limits. The motion systems of the two mirror assemblies provide five degrees of freedom and are designed to maintain a pointing accuracy within seven arc-sec with a response frequency in excess of 10 Hz. The pylon motion system incorporates controlled pitch and yaw movement. The fuselage motion system compensates for pitch variation as well as linear translation for focal length and vertical aiming of the laser beam via a controlled beam guidance mechanism.

Graham, Michael↗

Telescope Scientist on the Advanced X-Ray Astrophysics Observatory

The most important activity during this reporting period was the calibration of the AXAF High Resolution Mirror Assembly (HRMA) and the analysis of the copious data which were obtained during that project. The calibration was highly successful, and will result in the AXAF being by far the best calibrated X-ray observatory ever flown, and more accurate results by all of its users. This period also included participation in the spacecraft alignment and assembly activities and final flight readiness reviews. The planning of the first year of Telescope Scientist AXAF observations also was accomplished. The Telescope Scientist team also served as a technical resource for various problems which were encountered during this period. Many of these contributions have been documented in memoranda sent to the project.

VanSpeybroeck, Leon↗

Uses of Continuum Radiation in the AXAF Calibration

X-ray calibration of the Advanced X-ray Astrophysics Facility (AXAF) observatory at the MSFC X-Ray Calibration Facility (XRCF) made novel use of the x-ray continuum from a conventional electron-impact source. Taking advantage of the good spectral resolution of solid-state detectors, continuum measurements proved advantageous in calibrating the effective area of AXAF's High-Resolution Mirror Assembly (HRMA) and in verifying its alignment to the XRCF's optical axis.

Kolodziejczak, J. J.↗

Significance of Landsat-7 Spacecraft Level Thermal Balance and Thermal Test for ETM+Instrument

The thermal design and the instrument thermal vacuum (T/V) test of the Landsat-7 Enhanced Thematic Mapper Plus (ETM+) instrument were based on the Landsat-4, 5 and 6 heritage. The ETM+ scanner thermal model was also inherited from Landsat-4, 5 and 6. The temperature predictions of many scanner components in the original thermal model had poor agreement with the spacecraft and instrument integrated sun-pointing safehold (SPSH) thermal balance (T/B) test results. The spacecraft and instrument integrated T/B test led to a change of the Full Aperture Calibrator (FAC) motor stack "solar shield" coating from MIL-C-5541 to multi-layer insulation (MLI) thermal blanket. The temperature predictions of the Auxiliary Electronics Module (AEM) in the thermal model also had poor agreement with the T/B test results. Modifications to the scanner and AEM thermal models were performed to give good agreement between the temperature predictions and the test results. The correlated ETM+ thermal model was used to obtain flight temperature predictions. The flight temperature predictions in the nominal 15-orbit mission profile, plus margins, were used as the yellow limits for most of the ETM+ components. The spacecraft and instrument integrated T/B and TN test also revealed that the standby heater capacity on the Scan Mirror Assembly (SMA) was insufficient when the Earth Background Simulator (EBS) was 1 50C or colder, and the baffle heater possibly caused the coherent noise in the narrow band data when it was on. Also, the cooler cool-down was significantly faster than that in the instrument T/V test, and the coldest Cold Focal Plane Array (CFPA) temperature achieved was colder.

Choi, Michael K.↗

Progress in Using Continuum radiation for AXAF Calibration

X-ray calibration of the AXAF observatory at MSFC's X-Ray Calibration Facility (XRCF) made novel use of the x-ray continuum from a conventional electron-impact source. Taking advantage of the good spectral resolution of solid-state detectors, continuum measurements proved advantageous in calibrating the effective area of AXAF's High-Resolution Mirror Assembly (HRMA) and in verifying its alignment to the XRCF's optical axis. Further verification of AXAF response models will be presented.

Kolodziejczak, J. J.↗

Calibration Results for the AXAF Flux Contamination Monitor

The Flux Contamination Monitor (FCM) on the Advanced X-ray Astrophysics Facility (AXAF) serves the purposes of transfering the absolute flux calibration from the ground calibration at the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center to operation on orbit and of detecting any changes in molecular contamination of the High Resolution Mirror Assembly (HRMA) between ground calibration and the post-launch activation phase. we describe the design, construction, and characterization of the FCM radioactive sources, and their placement on the Forward Contamination Cover (FCC). We present results from FCM measurements with the AXAF focal plane instruments, particularly the AXAF CCD Imaging Spectrometer (ACIS), during the ground calibration phase at XRCF in 1997. Finally, we describe the plans for FCM on-orbit measurements during observatory activation and the subsequent analysis.

Elsner, Ronald F.↗

Calibration Results for the AXAF Flux Contamination Monitor

The AXAF Flux Contamination Monitor (FCM) serves the purposes of transferring the absolute flux calibration from the ground calibration at the X-Ray Calibration Facility (XRCF) to operation on orbit and of detecting any changes in molecular contamination of the High-Resolution Mirror Assembly (HRMA) between ground calibration and the post-launch activation. We describe the design, construction, and characterization of the FCM radioactive sources, and their placement on the Forward Contamination Cover (FCC). We present results from FCM measurements with the AXAF focal-plane instruments, particularly the AXAF CCD Imaging Spectrometer (ACIS), during the ground calibration phase at the XRCF in 1997. Finally, we describe the plans for FCM on-orbit measurements during observatory activation and for the subsequent analysis.

Elsner, R. F.↗

Effective Area of the AXAF High Resolution Camera (HRC)

The AXAF High-Resolution Camera (HRC) was calibrated at NASA MSFC's X-Ray Calibration Facility (XRCF) during 1997 March and April. We have undertaken an analysis of the HRC effective area using all data presently available from the XRCF. We discuss our spectral fitting of the beam-normalization detectors (BNDs), our method of removing higher order contamination lines present in the spectra, and corrections for beam non-uniformities. We apply a model of photon absorption depth in order to fit a smooth curve to the quantum efficiency of the detector. This is then combined with the most recent model of the AXAF High-Resolution Mirror Assembly (HRMA) to determine the ensemble effective area versus energy for the HRC. We also address future goals and concerns.

Patnaude, Daniel↗

Metrology Plan for the Lightweight Technology Demonstration Mirror Program

The purpose of this document is to establish the requirements and procedures for in-process and acceptance testing of the Goddard Primary Mirror and Primary Mirror Assembly. In-process testing is an iterative cycle of testing and figuring until the PM optical surface meets the criteria with considerations for mount induced errors.

Krill, Daniel↗

Development of a Mirror Pointing Mechanism for an Atmospheric Gas Measurement Instrument

Development of the Open Path Tunable Infrared Monitor of the Atmosphere (OPTIMA) instrument involved designing a pair of motion systems that could maintain a precise alignment and spatial distance between two mirrors installed on the NASA DC-8 research laboratory aircraft. This is the first airborne optical instrument that allows direct measurement of the gases in the freestream airflow on the exterior of the aircraft. One mirror is mounted within a specially constructed open port cavity in the cabin of the aircraft and the second is mounted 6 meters away on top of the inboard port side (number 2) engine pylon. Three co-aligned laser beams are reflected between the two mirrors 64 times in a Herriott pattern. The resulting sample path length of 384 meters is used to perform a spectral absorption analysis of the airflow between the mirrors. To compensate for normal wing movement and engine oscillations both mirrors were designed as continuously driven mechanisms to maintain alignment within allowable limits. The motion systems of the two mirror assemblies provide five degrees of freedom and are designed to maintain a pointing accuracy within seven arc-sec with a response frequency in 6xcess of 10 Hz. The pylon motion system incorporates controlled pitch and yaw movement. The fuselage motion system compensates for pitch variation as well as linear translation for focal length and vertical aiming of the laser beam via a controlled beam guidance mechanism.

Graham, Michael↗

Radiation Environment of the Chandra X-Ray Observatory

The Chandra X-ray Observatory lies in a highly elliptical orbit which dips into the outer radiation belt. During the initial stages of orbital operations, Chandra's front-illuminated CCD's (but not the back-illuminated ones) experienced an unanticipated degradation of the charge-transfer efficiency. The subsequent anomaly investigation determined that moderately low-energy protons (or other ions) propagated through the mirror assembly, causing the observed damage. This paper summarizes the effort to determine the radiation environment at the Chandra focal plane and the steps taken to prevent further performance degradation by magnetospheric and solar-wind protons and other ions.

ODell, S. L.↗

Overview of MSFC AMSD Integrated Modeling and Analysis

Structural, thermal, dynamic, and optical models of the NGST AMSD mirror assemblies are being finalized and integrated for predicting cryogenic vacuum test performance of the developing designs. Analyzers in use by the MSFC Modeling and Analysis Team are identified, with overview of approach to integrate simulated effects. Guidelines to verify the individual models and calibration cases for comparison with the vendors' analyses are presented. In addition, baseline and proposed additional scenarios for the cryogenic vacuum testing are briefly described.

Cummings, Ramona↗